🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A. PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A. is a laboratory accredited by PCA under number AB 1800 (Wrocław, Poland). Its accreditation scope covers 62 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD).
At a glance
- Accreditation number: PCA AB 1800
- Methods in scope: 62
- Types of test objects: 8
- Techniques used: 20
- City: Wrocław, Poland
- Valid until: 27.09.2029
- Accreditation number
- AB 1800
- Accreditation body
- PCA
- Address
- ul. Na Grobli 19, 50-421 Wrocław, CENTRUM NOWYCH TECHNOLOGII, LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Starodworska 100, 50-458 Mokry Dwór
- City
- Wrocław, Poland
- Valid until
- 27.09.2029
What this laboratory tests (8)
- Water intended for human consumption, Water — 17 methods
- Water — 15 methods
- Water intended for human consumption — 15 methods
- Wastewater — 10 methods
- Wastewater, Water — 2 methods
- Rainwater and snowmelt water — 1 method
- Water, Rainwater, snowmelt water — 1 method
- Water, Rainwater, snowmelt water, Wastewater — 1 method
Analytical techniques used (20)
- Membrane filtration method — 10 methods
- Spectrophotometric method — 7 methods
- Ion chromatography with conductometric detection (IC-CD) — 4 methods
- MPN method — 4 methods
- Plate method (pour plate) — 4 methods
- Electrochemical method — 3 methods
- Gravimetric method — 2 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 2 methods
- Potentiometric method — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Conductometric method — 1 method
- Full paired method, non-forced choice — 1 method
- Gas chromatography with flame ionization detection (GC-FID) — 1 method
- Headspace gas chromatography with electron capture detection (HS-GC-ECD) — 1 method
- High-temperature combustion with IR detection — 1 method
- and 5 more
Laboratory sections (3)
- Pracownia Fizyko-Chemiczna Wody — 30 methods
- Pracownia Mikrobiologiczna — 19 methods
- Pracownia Fizyko-Chemiczna Ścieków — 13 methods
Laboratory locations
- CENTRUM NOWYCH TECHNOLOGII LABORATORIUM BADANIA WODY I ŚCIEKÓW — ul. Starodworska 100, 50-458 Mokry Dwór
- Pracownia Fizyko-Chemiczna Wody — ul. Starodworska 100, 50-458 Mokry Dwór
- Pracownia Mikrobiologiczna — ul. Starodworska 100, 50-458 Mokry Dwór
- Pracownia Fizyko-Chemiczna Ścieków — ul. Janowska 47, 54-067 Wrocław
Accreditation scope — test methods (62)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Pracownia Fizyko-Chemiczna Wody | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Temperature Range (0,0 – 80,0) °C |
PN-77/C-04584 | ||
| 3 | Water intended for human consumption | Free chlorine concentration Range (0,05 – 2,0) mg/l Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 4 | Water intended for human consumption | Presence of foreign taste Threshold flavour number (TFN) Range 1 – 2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 5 | Water intended for human consumption | Presence of foreign odour Threshold odour number (TON) Range 1 – 2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 6 | Water | Presence of foreign odour Threshold odour number (TON) Range 1 – 32 |
Full paired method, non-forced choice | PN-EN 1622:2006 | |
| 7 | Water | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2 | ||
| 8 | Water | Temperature Range (0,0 – 50,0) °C |
PN-77/C-04584 | ||
| 9 | Water | Dissolved oxygen concentration Range (0,5 – 20,0) mg/l O2 Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium |
Optical method | ISO 17289:2014 | |
| 10 | Water | Chemical oxygen demand – COD-Cr Range (4,0 – 300) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 11 | Water | Biochemical oxygen demand – BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 12 | Water intended for human consumption, Water | pH Range 2,0 – 10,0 Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 13 | Water intended for human consumption, Water | Electrical conductivity Range (10,0 − 5000) µS/cm Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium |
Conductometric method | PN-EN 27888:1999 | |
| 14 | Water intended for human consumption, Water | Turbidity Range (0,30 – 50) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 15 | Water intended for human consumption, Water | Colour Range (2 – 50) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 | |
| 16 | Water intended for human consumption, Water | Nitrite concentration Range (0,010 – 0,80) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 17 | Water intended for human consumption, Water | Nitrite nitrogen concentration (calculated) | PN-EN 26777:1999 | ||
| 18 | Water intended for human consumption, Water | Ammonium ion concentration Range (0,050 – 1,00) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 19 | Water intended for human consumption, Water | Ammonium nitrogen concentration (calculated) | PN-ISO 7150-1:2002 | ||
| 20 | Water intended for human consumption, Water | Total organic carbon concentration (TOC) Range (1,0 – 20) mg/l |
High-temperature combustion with IR detection | PN-EN 1484:1999 | |
| 21 | Water intended for human consumption, Water | Anion concentrations: chlorides (5,0 − 300) mg/l sulfates (5,0 − 300) mg/l fluorides (0,10 – 1,50) mg/l nitrates (2,0 – 50) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 22 | Water intended for human consumption, Water | Chlorite and chlorate concentration chlorites (0,05 – 1,00) mg/l chlorates (0,05 – 1,00) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO10304-4:2022-08 | |
| 23 | Water intended for human consumption, Water | Sum of chlorites and chlorates (calculated) | PN-EN ISO10304-4:2022-08 | ||
| 24 | Water intended for human consumption, Water | Metal concentrations antimony (0,50 – 500) µg/l arsenic (0,50 – 500) µg/l barium (10,0 – 1000) µg/l boron (10,0 – 5000) µg/l chromium (0,50 – 500) µg/l zinc (10,0 – 5000) µg/l aluminium (10,0 – 1000) µg/l cadmium (0,50 – 500) µg/l magnesium (0,50 – 200) mg/l manganese (5,0 – 1000) µg/l copper (10,0 – 5000) µg/l nickel (0,50 – 500) µg/l lead (0,50 – 500) µg/l potassium (0,50 – 200) mg/l mercury (0,10 – 2,0) µg/l selenium (0,50 – 500) µg/l sodium (0,50 – 200) mg/l silver (0,50 – 500) µg/l uranium (0,50 – 100) µg/l vanadium (10,0 – 1000) µg/l calcium (0,50 – 200) mg/l iron (10,0 – 10000) µg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 25 | Water intended for human consumption, Water | Total hardness (calculated) | PB01 wyd. 1.1 z dnia 17.12.2019 r. | ||
| 26 | Water intended for human consumption, Water | Concentration of volatile halogenated hydrocarbons Chloroform (2,0 – 100) µg/l Bromodichloromethane (2,0 – 100) µg/l Dibromochloromethane (2,0 – 100) µg/l Bromoform (2,0 – 100) µg/l Trichloroethene (0,2 – 10) µg/l Tetrachloroethene (0,2 – 10) µg/l 1,2-dichloroethane (0,2 – 10) µg/l |
Headspace gas chromatography with electron capture detection (HS-GC-ECD) | PN-EN ISO 10301:2002 Rozdział 3 | |
| 27 | Water intended for human consumption, Water | Sum of THM (calculated) | PN-EN ISO 10301:2002 Rozdział 3 | ||
| 28 | Water intended for human consumption, Water | Sum of trichloroethene and tetrachloroethene (calculated) | PN-EN ISO 10301:2002 Rozdział 3 | ||
| 29 | Water, Rainwater, snowmelt water | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 30 | Water, Rainwater, snowmelt water, Wastewater | Mineral oil index Range (0,50 – 50,0) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| Pracownia Mikrobiologiczna | |||||
| 31 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 32 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 33 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 34 | Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 35 | Water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 36 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 37 | Water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 38 | Water intended for human consumption | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 39 | Water intended for human consumption | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 40 | Water intended for human consumption | Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC | Membrane filtration method | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | |
| 41 | Water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 42 | Water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 43 | Water | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 44 | Water | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 45 | Water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 46 | Water | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 47 | Water | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 48 | Water | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 49 | Water | Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC | Membrane filtration method | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | |
| Pracownia Fizyko-Chemiczna Ścieków | |||||
| 50 | Rainwater and snowmelt water | Sampling for physicochemical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 51 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 52 | Wastewater | Temperature Range (0,0 – 50,0) °C |
PN-77/C-04584 | ||
| 53 | Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 54 | Wastewater | Total suspended solids (TSS) Range (10 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 55 | Wastewater | Chemical oxygen demand − COD-Cr Range (25 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 56 | Wastewater | Anion concentrations: chlorides (10 − 2000) mg/l sulfates (10 − 2000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 57 | Wastewater | Biochemical oxygen demand − BOD5 Range (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 58 | Wastewater | Biochemical oxygen demand − BOD5 Range (6 – 1000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 59 | Wastewater | Element concentration total chromium (0,050 – 10,0) mg/l zinc (0,050 – 10,0) mg/l cadmium (0,050 – 10,0) mg/l aluminium (0,050 – 20,0) mg/l manganese (0,050 – 20,0) mg/l copper (0,050 – 10,0) mg/l nickel (0,050 – 10,0) mg/l lead (0,050 – 10,0) mg/l iron (0,050 – 20,0) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 60 | Wastewater | Ammonium nitrogen concentration Range (0,20 – 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | |
| 61 | Wastewater, Water | Total phosphorus concentration Range (0,050 – 100) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 62 | Wastewater, Water | Total nitrogen concentration Range (1,0 – 150) mg/l |
Spectrophotometric method | PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001 | |
Reference standards (34)
ISO 17289:2014
PB01 wyd. 1.1 z dnia 17.12.2019 r.
PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001
PN-77/C-04584
PN-EN 1484:1999
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002 Rozdział 3
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 17294-2:2024-04
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9377-2:2003
PN-EN ISO10304-4:2022-08
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2
PN-ISO 7150-1:2002