🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A. PL

PCA AB 1800 • Wrocław, Poland • 62 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A. is a laboratory accredited by PCA under number AB 1800 (Wrocław, Poland). Its accreditation scope covers 62 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD).

At a glance

  • Accreditation number: PCA AB 1800
  • Methods in scope: 62
  • Types of test objects: 8
  • Techniques used: 20
  • City: Wrocław, Poland
  • Valid until: 27.09.2029
Accreditation number
AB 1800
Accreditation body
PCA
Address
ul. Na Grobli 19, 50-421 Wrocław, CENTRUM NOWYCH TECHNOLOGII, LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Starodworska 100, 50-458 Mokry Dwór
City
Wrocław, Poland
Valid until
27.09.2029

What this laboratory tests (8)

Analytical techniques used (20)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (62)

No. Test object Methodology / Parameters Technique Reference document
Pracownia Fizyko-Chemiczna Wody
1 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
2 Water intended for human consumption Temperature
Range (0,0 – 80,0) °C
PN-77/C-04584
3 Water intended for human consumption Free chlorine concentration
Range (0,05 – 2,0) mg/l
Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium
Spectrophotometric method PN-EN ISO 7393-2:2018-04
4 Water intended for human consumption Presence of foreign taste Threshold flavour number (TFN)
Range 1 – 2
Simplified method, paired, non-forced choice PN-EN 1622:2006
5 Water intended for human consumption Presence of foreign odour Threshold odour number (TON)
Range 1 – 2
Simplified method, paired, non-forced choice PN-EN 1622:2006
6 Water Presence of foreign odour Threshold odour number (TON)
Range 1 – 32
Full paired method, non-forced choice PN-EN 1622:2006
7 Water Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2
8 Water Temperature
Range (0,0 – 50,0) °C
PN-77/C-04584
9 Water Dissolved oxygen concentration
Range (0,5 – 20,0) mg/l O2
Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium
Optical method ISO 17289:2014
10 Water Chemical oxygen demand – COD-Cr
Range (4,0 – 300) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
11 Water Biochemical oxygen demand – BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
12 Water intended for human consumption, Water pH
Range 2,0 – 10,0
Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium
Potentiometric method PN-EN ISO 10523:2012
13 Water intended for human consumption, Water Electrical conductivity
Range (10,0 − 5000) µS/cm
Regulated area: badania wykonywanie w siedzibie i poza siedzibą Laboratorium
Conductometric method PN-EN 27888:1999
14 Water intended for human consumption, Water Turbidity
Range (0,30 – 50) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
15 Water intended for human consumption, Water Colour
Range (2 – 50) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
16 Water intended for human consumption, Water Nitrite concentration
Range (0,010 – 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
17 Water intended for human consumption, Water Nitrite nitrogen concentration (calculated) PN-EN 26777:1999
18 Water intended for human consumption, Water Ammonium ion concentration
Range (0,050 – 1,00) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
19 Water intended for human consumption, Water Ammonium nitrogen concentration (calculated) PN-ISO 7150-1:2002
20 Water intended for human consumption, Water Total organic carbon concentration (TOC)
Range (1,0 – 20) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999
21 Water intended for human consumption, Water Anion concentrations:
chlorides (5,0 − 300) mg/l sulfates (5,0 − 300) mg/l fluorides (0,10 – 1,50) mg/l nitrates (2,0 – 50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
22 Water intended for human consumption, Water Chlorite and chlorate concentration
chlorites (0,05 – 1,00) mg/l chlorates (0,05 – 1,00) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO10304-4:2022-08
23 Water intended for human consumption, Water Sum of chlorites and chlorates (calculated) PN-EN ISO10304-4:2022-08
24 Water intended for human consumption, Water Metal concentrations
antimony (0,50 – 500) µg/l arsenic (0,50 – 500) µg/l barium (10,0 – 1000) µg/l boron (10,0 – 5000) µg/l chromium (0,50 – 500) µg/l zinc (10,0 – 5000) µg/l aluminium (10,0 – 1000) µg/l cadmium (0,50 – 500) µg/l magnesium (0,50 – 200) mg/l manganese (5,0 – 1000) µg/l copper (10,0 – 5000) µg/l nickel (0,50 – 500) µg/l lead (0,50 – 500) µg/l potassium (0,50 – 200) mg/l mercury (0,10 – 2,0) µg/l selenium (0,50 – 500) µg/l sodium (0,50 – 200) mg/l silver (0,50 – 500) µg/l uranium (0,50 – 100) µg/l vanadium (10,0 – 1000) µg/l calcium (0,50 – 200) mg/l iron (10,0 – 10000) µg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
25 Water intended for human consumption, Water Total hardness (calculated) PB01 wyd. 1.1 z dnia 17.12.2019 r.
26 Water intended for human consumption, Water Concentration of volatile halogenated hydrocarbons
Chloroform (2,0 – 100) µg/l Bromodichloromethane (2,0 – 100) µg/l Dibromochloromethane (2,0 – 100) µg/l Bromoform (2,0 – 100) µg/l Trichloroethene (0,2 – 10) µg/l Tetrachloroethene (0,2 – 10) µg/l 1,2-dichloroethane (0,2 – 10) µg/l
Headspace gas chromatography with electron capture detection (HS-GC-ECD) PN-EN ISO 10301:2002 Rozdział 3
27 Water intended for human consumption, Water Sum of THM (calculated) PN-EN ISO 10301:2002 Rozdział 3
28 Water intended for human consumption, Water Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 10301:2002 Rozdział 3
29 Water, Rainwater, snowmelt water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
30 Water, Rainwater, snowmelt water, Wastewater Mineral oil index
Range (0,50 – 50,0) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
Pracownia Mikrobiologiczna
31 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
32 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
33 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
34 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
35 Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
36 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
37 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
38 Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
39 Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
40 Water intended for human consumption Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
41 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
42 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
43 Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
44 Water Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
45 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
46 Water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
47 Water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
48 Water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
49 Water Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
Pracownia Fizyko-Chemiczna Ścieków
50 Rainwater and snowmelt water Sampling for physicochemical testing Manual method PN-ISO 5667-10:2021-11
51 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
52 Wastewater Temperature
Range (0,0 – 50,0) °C
PN-77/C-04584
53 Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
54 Wastewater Total suspended solids (TSS)
Range (10 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
55 Wastewater Chemical oxygen demand − COD-Cr
Range (25 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
56 Wastewater Anion concentrations:
chlorides (10 − 2000) mg/l sulfates (10 − 2000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
57 Wastewater Biochemical oxygen demand − BOD5
Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
58 Wastewater Biochemical oxygen demand − BOD5
Range (6 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
59 Wastewater Element concentration
total chromium (0,050 – 10,0) mg/l zinc (0,050 – 10,0) mg/l cadmium (0,050 – 10,0) mg/l aluminium (0,050 – 20,0) mg/l manganese (0,050 – 20,0) mg/l copper (0,050 – 10,0) mg/l nickel (0,050 – 10,0) mg/l lead (0,050 – 10,0) mg/l iron (0,050 – 20,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
60 Wastewater Ammonium nitrogen concentration
Range (0,20 – 1000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
61 Wastewater, Water Total phosphorus concentration
Range (0,050 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
62 Wastewater, Water Total nitrogen concentration
Range (1,0 – 150) mg/l
Spectrophotometric method PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001

Reference standards (34)

ISO 17289:2014
PB01 wyd. 1.1 z dnia 17.12.2019 r.
PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001
PN-77/C-04584
PN-EN 1484:1999
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002 Rozdział 3
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 17294-2:2024-04
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9377-2:2003
PN-EN ISO10304-4:2022-08
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2
PN-ISO 7150-1:2002