{"lab":{"_id":"69ad52a3de79e566650fb99d","accr_number":"AB 1800","country":"PL","accr_body":"PCA","address":"ul. Na Grobli 19, 50-421 Wrocław, CENTRUM NOWYCH TECHNOLOGII, LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. Starodworska 100, 50-458 Mokry Dwór","categories":["water","microbiology"],"city":"Wrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":62,"name":"MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1800.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo wodociągów i kanalizacji s.a. ul. na grobli 19, 50-421 wrocław, centrum nowych technologii, laboratorium badania wody i ścieków, ul. starodworska 100, 50-458 mokry dwór water other pharma electronics materials food microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:56.255Z","valid_from":"","valid_until":"27.09.2029","website":"","parsed_at":"2026-08-17T15:12:44.869Z","location":{"type":"Point","coordinates":[17.0385,51.1079]},"email_confidence":"high","email_mx":true,"email_source":"https://www.mpwik.wroc.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P, C/29/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"},{"codes":"N/28/P, N/29/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"7","date":"23.07.2026"},"parse_date":"2026-08-17T15:12:44.869Z","parse_source":"agent-claude-code","map_coord":[51.103799,17.057317],"map_geo":"nominatim-street","lab_locations":[{"name":"CENTRUM NOWYCH TECHNOLOGII LABORATORIUM BADANIA WODY I ŚCIEKÓW","address":"ul. Starodworska 100, 50-458 Mokry Dwór","city":"Mokry Dwór","postal":"50-458"},{"name":"Pracownia Fizyko-Chemiczna Wody","address":"ul. Starodworska 100, 50-458 Mokry Dwór","city":"Mokry Dwór","postal":"50-458"},{"name":"Pracownia Mikrobiologiczna","address":"ul. Starodworska 100, 50-458 Mokry Dwór","city":"Mokry Dwór","postal":"50-458"},{"name":"Pracownia Fizyko-Chemiczna Ścieków","address":"ul. Janowska 47, 54-067 Wrocław","city":"Wrocław","postal":"54-067"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/0ff40e0ea5838d1b10950fa43d063389/AB%201800.pdf","has_en":true,"category_counts":{"water":62,"microbiology":11,"materials":2,"petro":1},"category_scores":{"water":50.58,"microbiology":1.59,"materials":0.05,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a8324ec884ede9a1b2c4faa","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a8324ec884ede9a1b2c4fab","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 80,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 80,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (0,0 – 80,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura\nZakres (0,0 – 80,0) °C PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 80,0) °C"}],"search_en":"Water intended for human consumption Temperature Range PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,0 – 80,0) °C"}],"search_zh":"生活饮用水 温度 范围 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a8324ec884ede9a1b2c4fac","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fad","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego smaku Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"1 – 2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Obecność obcego smaku Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego smaku Liczba progowa smaku (TFN)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of foreign taste Threshold flavour number (TFN)","parameters_en":[{"name":"Range","range":"1 – 2"}],"search_en":"Water intended for human consumption Presence of foreign taste Threshold flavour number (TFN) Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"生活饮用水 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择"},{"_id":"6a8324ec884ede9a1b2c4fae","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego zapachu Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"1 – 2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Obecność obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of foreign odour Threshold odour number (TON)","parameters_en":[{"name":"Range","range":"1 – 2"}],"search_en":"Water intended for human consumption Presence of foreign odour Threshold odour number (TON) Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"生活饮用水 异味的检出 嗅阈值（TON） 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"异味的检出 嗅阈值（TON）"},{"_id":"6a8324ec884ede9a1b2c4faf","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Obecność obcego zapachu Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"1 – 32"}],"technique":"Metoda pełna parzysta, wybór niewymuszony","techniques":["Metoda pełna parzysta, wybór niewymuszony"],"computed":[],"activity":"Obecność obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 32\nMetoda pełna parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Obecność obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 32\nMetoda pełna parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Obecnosc obcego zapachu Liczba progowa zapachu (TON)\nZakres 1 – 32\nMetoda pelna parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of foreign odour Threshold odour number (TON)","parameters_en":[{"name":"Range","range":"1 – 32"}],"search_en":"Water Presence of foreign odour Threshold odour number (TON) Full paired method, non-forced choice Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"1 – 32"}],"search_zh":"水 异味的检出 嗅阈值（TON） 完全法、成对法、非强制选择 范围 PN-EN 1622:2006","test_object_zh":"水","technique_zh":"完全法、成对法、非强制选择","methodology_zh":"异味的检出 嗅阈值（TON）"},{"_id":"6a8324ec884ede9a1b2c4fb0","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2","norm_bases":["PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2 Woda Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-6:2016-12 z wylaczeniem pkt 7.5, 7.6, 8.2","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2","test_object_en":"Water","search_zh":"水 化学和物理检测采样（含感官检测） PN-ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6, 8.2","test_object_zh":"水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a8324ec884ede9a1b2c4fb1","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0,0 – 50,0) °C PN-77/C-04584 Woda Temperatura\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a8324ec884ede9a1b2c4fb2","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 20,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a8324ec884ede9a1b2c4fb3","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(4,0 – 300) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (4,0 – 300) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (4,0 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (4,0 – 300) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(4,0 – 300) mg/l O2"}],"search_en":"Water Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(4,0 – 300) mg/l O2"}],"search_zh":"水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a8324ec884ede9a1b2c4fb4","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water Biochemical oxygen demand – BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8324ec884ede9a1b2c4fb5","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, Woda pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water intended for human consumption, Water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fb6","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 − 5000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 − 5000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":"badania wykonywanie w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Przewodność elektryczna właściwa\nZakres (10,0 − 5000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi, Woda Przewodnosc elektryczna wlasciwa\nZakres (10,0 − 5000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 − 5000) µS/cm"}],"search_en":"Water intended for human consumption, Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 − 5000) µS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fb7","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Mętność\nZakres (0,30 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi, Woda Metnosc\nZakres (0,30 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 50) NTU"}],"search_en":"Water intended for human consumption, Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 50) NTU"}],"search_zh":"生活饮用水、水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fb8","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 50) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 50) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Barwa\nZakres (2 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda do spozycia przez ludzi, Woda Barwa\nZakres (2 – 50) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 50) mg/l Pt"}],"search_en":"Water intended for human consumption, Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 50) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fb9","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotynów\nZakres (0,010 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, Woda Stezenie azotynow\nZakres (0,010 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,80) mg/l"}],"search_en":"Water intended for human consumption, Water Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,80) mg/l"}],"search_zh":"生活饮用水、水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fba","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotu azotynowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu azotynowego (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotu azotynowego (z obliczeń) PN-EN 26777:1999 Woda do spozycia przez ludzi, Woda Stezenie azotu azotynowego (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration (calculated)","search_en":"Water intended for human consumption, Water Nitrite nitrogen concentration (calculated) PN-EN 26777:1999","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 亚硝酸盐氮浓度（由计算得出） PN-EN 26777:1999","test_object_zh":"生活饮用水、水","methodology_zh":"亚硝酸盐氮浓度（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fbb","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie jonu amonowego\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, Woda Stezenie jonu amonowego\nZakres (0,050 – 1,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,050 – 1,00) mg/l"}],"search_en":"Water intended for human consumption, Water Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 1,00) mg/l"}],"search_zh":"生活饮用水、水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fbc","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, Woda Stezenie azotu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration (calculated)","search_en":"Water intended for human consumption, Water Ammonium nitrogen concentration (calculated) PN-ISO 7150-1:2002","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 铵态氮浓度（由计算得出） PN-ISO 7150-1:2002","test_object_zh":"生活饮用水、水","methodology_zh":"铵态氮浓度（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fbd","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,0 – 20) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda do spozycia przez ludzi, Woda Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 20) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,0 – 20) mg/l"}],"search_en":"Water intended for human consumption, Water Total organic carbon concentration (TOC) High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water intended for human consumption, Water","parameters_zh":[{"name":"范围","range":"(1,0 – 20) mg/l"}],"search_zh":"生活饮用水、水 总有机碳浓度（TOC） 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"生活饮用水、水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a8324ec884ede9a1b2c4fbe","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie anionów:","parameters":[{"name":"chlorki","range":"(5,0 − 300) mg/l"},{"name":"siarczany","range":"(5,0 − 300) mg/l"},{"name":"fluorki","range":"(0,10 – 1,50) mg/l"},{"name":"azotany","range":"(2,0 – 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nchlorki (5,0 − 300) mg/l\nsiarczany (5,0 − 300) mg/l\nfluorki (0,10 – 1,50) mg/l\nazotany (2,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie anionów:\nZakres:\nchlorki (5,0 − 300) mg/l\nsiarczany (5,0 − 300) mg/l\nfluorki (0,10 – 1,50) mg/l\nazotany (2,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi, Woda Stezenie anionow:\nZakres:\nchlorki (5,0 − 300) mg/l\nsiarczany (5,0 − 300) mg/l\nfluorki (0,10 – 1,50) mg/l\nazotany (2,0 – 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"chlorides","range":"(5,0 − 300) mg/l"},{"name":"sulfates","range":"(5,0 − 300) mg/l"},{"name":"fluorides","range":"(0,10 – 1,50) mg/l"},{"name":"nitrates","range":"(2,0 – 50) mg/l"}],"search_en":"Water intended for human consumption, Water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) chlorides sulfates fluorides nitrates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption, Water","methodology_zh":"阴离子浓度：","search_zh":"生活饮用水、水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 氟化物 硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","parameters_zh":[{"name":"氯化物","range":"(5,0 − 300) mg/l"},{"name":"硫酸盐","range":"(5,0 − 300) mg/l"},{"name":"氟化物","range":"(0,10 – 1,50) mg/l"},{"name":"硝酸盐","range":"(2,0 – 50) mg/l"}],"test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fbf","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie chlorynów i chloranów","parameters":[{"name":"chloryny","range":"(0,05 – 1,00) mg/l"},{"name":"chlorany","range":"(0,05 – 1,00) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorynów i chloranów\nZakres:\nchloryny (0,05 – 1,00) mg/l\nchlorany (0,05 – 1,00) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO10304-4:2022-08","norm_bases":["PN-EN ISO10304-4:2022-08"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie chlorynów i chloranów\nZakres:\nchloryny (0,05 – 1,00) mg/l\nchlorany (0,05 – 1,00) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO10304-4:2022-08 Woda do spozycia przez ludzi, Woda Stezenie chlorynow i chloranow\nZakres:\nchloryny (0,05 – 1,00) mg/l\nchlorany (0,05 – 1,00) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO10304-4:2022-08","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorite and chlorate concentration","parameters_en":[{"name":"chlorites","range":"(0,05 – 1,00) mg/l"},{"name":"chlorates","range":"(0,05 – 1,00) mg/l"}],"search_en":"Water intended for human consumption, Water Chlorite and chlorate concentration Ion chromatography with conductometric detection (IC-CD) chlorites chlorates PN-EN ISO10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 离子色谱-电导检测法（IC-CD） 亚氯酸盐 氯酸盐 PN-EN ISO10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水、水","parameters_zh":[{"name":"亚氯酸盐","range":"(0,05 – 1,00) mg/l"},{"name":"氯酸盐","range":"(0,05 – 1,00) mg/l"}]},{"_id":"6a8324ec884ede9a1b2c4fc0","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Suma chlorynów i chloranów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chlorynów i chloranów (z obliczeń)","reference":"PN-EN ISO10304-4:2022-08","norm_bases":["PN-EN ISO10304-4:2022-08"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Suma chlorynów i chloranów (z obliczeń) PN-EN ISO10304-4:2022-08 Woda do spozycia przez ludzi, Woda Suma chlorynow i chloranow (z obliczen) PN-EN ISO10304-4:2022-08","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorites and chlorates (calculated)","search_en":"Water intended for human consumption, Water Sum of chlorites and chlorates (calculated) PN-EN ISO10304-4:2022-08","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 亚氯酸盐与氯酸盐总量（由计算得出） PN-EN ISO10304-4:2022-08","test_object_zh":"生活饮用水、水","methodology_zh":"亚氯酸盐与氯酸盐总量（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fc1","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie metali","parameters":[{"name":"antymon","range":"(0,50 – 500) µg/l"},{"name":"arsen","range":"(0,50 – 500) µg/l"},{"name":"bar","range":"(10,0 – 1000) µg/l"},{"name":"bor","range":"(10,0 – 5000) µg/l"},{"name":"chrom","range":"(0,50 – 500) µg/l"},{"name":"cynk","range":"(10,0 – 5000) µg/l"},{"name":"glin","range":"(10,0 – 1000) µg/l"},{"name":"kadm","range":"(0,50 – 500) µg/l"},{"name":"magnez","range":"(0,50 – 200) mg/l"},{"name":"mangan","range":"(5,0 – 1000) µg/l"},{"name":"miedź","range":"(10,0 – 5000) µg/l"},{"name":"nikiel","range":"(0,50 – 500) µg/l"},{"name":"ołów","range":"(0,50 – 500) µg/l"},{"name":"potas","range":"(0,50 – 200) mg/l"},{"name":"rtęć","range":"(0,10 – 2,0) µg/l"},{"name":"selen","range":"(0,50 – 500) µg/l"},{"name":"sód","range":"(0,50 – 200) mg/l"},{"name":"srebro","range":"(0,50 – 500) µg/l"},{"name":"uran","range":"(0,50 – 100) µg/l"},{"name":"wanad","range":"(10,0 – 1000) µg/l"},{"name":"wapń","range":"(0,50 – 200) mg/l"},{"name":"żelazo","range":"(10,0 – 10000) µg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nantymon (0,50 – 500) µg/l\narsen (0,50 – 500) µg/l\nbar (10,0 – 1000) µg/l\nbor (10,0 – 5000) µg/l\nchrom (0,50 – 500) µg/l\ncynk (10,0 – 5000) µg/l\nglin (10,0 – 1000) µg/l\nkadm (0,50 – 500) µg/l\nmagnez (0,50 – 200) mg/l\nmangan (5,0 – 1000) µg/l\nmiedź (10,0 – 5000) µg/l\nnikiel (0,50 – 500) µg/l\nołów (0,50 – 500) µg/l\npotas (0,50 – 200) mg/l\nrtęć (0,10 – 2,0) µg/l\nselen (0,50 – 500) µg/l\nsód (0,50 – 200) mg/l\nsrebro (0,50 – 500) µg/l\nuran (0,50 – 100) µg/l\nwanad (10,0 – 1000) µg/l\nwapń (0,50 – 200) mg/l\nżelazo (10,0 – 10000) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie metali\nZakres:\nantymon (0,50 – 500) µg/l\narsen (0,50 – 500) µg/l\nbar (10,0 – 1000) µg/l\nbor (10,0 – 5000) µg/l\nchrom (0,50 – 500) µg/l\ncynk (10,0 – 5000) µg/l\nglin (10,0 – 1000) µg/l\nkadm (0,50 – 500) µg/l\nmagnez (0,50 – 200) mg/l\nmangan (5,0 – 1000) µg/l\nmiedź (10,0 – 5000) µg/l\nnikiel (0,50 – 500) µg/l\nołów (0,50 – 500) µg/l\npotas (0,50 – 200) mg/l\nrtęć (0,10 – 2,0) µg/l\nselen (0,50 – 500) µg/l\nsód (0,50 – 200) mg/l\nsrebro (0,50 – 500) µg/l\nuran (0,50 – 100) µg/l\nwanad (10,0 – 1000) µg/l\nwapń (0,50 – 200) mg/l\nżelazo (10,0 – 10000) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi, Woda Stezenie metali\nZakres:\nantymon (0,50 – 500) µg/l\narsen (0,50 – 500) µg/l\nbar (10,0 – 1000) µg/l\nbor (10,0 – 5000) µg/l\nchrom (0,50 – 500) µg/l\ncynk (10,0 – 5000) µg/l\nglin (10,0 – 1000) µg/l\nkadm (0,50 – 500) µg/l\nmagnez (0,50 – 200) mg/l\nmangan (5,0 – 1000) µg/l\nmiedz (10,0 – 5000) µg/l\nnikiel (0,50 – 500) µg/l\nolow (0,50 – 500) µg/l\npotas (0,50 – 200) mg/l\nrtec (0,10 – 2,0) µg/l\nselen (0,50 – 500) µg/l\nsod (0,50 – 200) mg/l\nsrebro (0,50 – 500) µg/l\nuran (0,50 – 100) µg/l\nwanad (10,0 – 1000) µg/l\nwapn (0,50 – 200) mg/l\nzelazo (10,0 – 10000) µg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["materials","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"antimony","range":"(0,50 – 500) µg/l"},{"name":"arsenic","range":"(0,50 – 500) µg/l"},{"name":"barium","range":"(10,0 – 1000) µg/l"},{"name":"boron","range":"(10,0 – 5000) µg/l"},{"name":"chromium","range":"(0,50 – 500) µg/l"},{"name":"zinc","range":"(10,0 – 5000) µg/l"},{"name":"aluminium","range":"(10,0 – 1000) µg/l"},{"name":"cadmium","range":"(0,50 – 500) µg/l"},{"name":"magnesium","range":"(0,50 – 200) mg/l"},{"name":"manganese","range":"(5,0 – 1000) µg/l"},{"name":"copper","range":"(10,0 – 5000) µg/l"},{"name":"nickel","range":"(0,50 – 500) µg/l"},{"name":"lead","range":"(0,50 – 500) µg/l"},{"name":"potassium","range":"(0,50 – 200) mg/l"},{"name":"mercury","range":"(0,10 – 2,0) µg/l"},{"name":"selenium","range":"(0,50 – 500) µg/l"},{"name":"sodium","range":"(0,50 – 200) mg/l"},{"name":"silver","range":"(0,50 – 500) µg/l"},{"name":"uranium","range":"(0,50 – 100) µg/l"},{"name":"vanadium","range":"(10,0 – 1000) µg/l"},{"name":"calcium","range":"(0,50 – 200) mg/l"},{"name":"iron","range":"(10,0 – 10000) µg/l"}],"search_en":"Water intended for human consumption, Water Metal concentrations Inductively coupled plasma mass spectrometry (ICP-MS) antimony arsenic barium boron chromium zinc aluminium cadmium magnesium manganese copper nickel lead potassium mercury selenium sodium silver uranium vanadium calcium iron PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water intended for human consumption, Water","methodology_zh":"金属浓度","parameters_zh":[{"name":"锑","range":"(0,50 – 500) µg/l"},{"name":"砷","range":"(0,50 – 500) µg/l"},{"name":"钡","range":"(10,0 – 1000) µg/l"},{"name":"硼","range":"(10,0 – 5000) µg/l"},{"name":"铬","range":"(0,50 – 500) µg/l"},{"name":"锌","range":"(10,0 – 5000) µg/l"},{"name":"铝","range":"(10,0 – 1000) µg/l"},{"name":"镉","range":"(0,50 – 500) µg/l"},{"name":"镁","range":"(0,50 – 200) mg/l"},{"name":"锰","range":"(5,0 – 1000) µg/l"},{"name":"铜","range":"(10,0 – 5000) µg/l"},{"name":"镍","range":"(0,50 – 500) µg/l"},{"name":"铅","range":"(0,50 – 500) µg/l"},{"name":"钾","range":"(0,50 – 200) mg/l"},{"name":"汞","range":"(0,10 – 2,0) µg/l"},{"name":"硒","range":"(0,50 – 500) µg/l"},{"name":"钠","range":"(0,50 – 200) mg/l"},{"name":"银","range":"(0,50 – 500) µg/l"},{"name":"铀","range":"(0,50 – 100) µg/l"},{"name":"钒","range":"(10,0 – 1000) µg/l"},{"name":"钙","range":"(0,50 – 200) mg/l"},{"name":"铁","range":"(10,0 – 10000) µg/l"}],"search_zh":"生活饮用水、水 金属浓度 电感耦合等离子体质谱法（ICP-MS） 锑 砷 钡 硼 铬 锌 铝 镉 镁 锰 铜 镍 铅 钾 汞 硒 钠 银 铀 钒 钙 铁 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"生活饮用水、水"},{"_id":"6a8324ec884ede9a1b2c4fc2","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Twardość ogólna (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość ogólna (z obliczeń)","reference":"PB01 wyd. 1.1 z dnia 17.12.2019 r.","norm_bases":["PB01 wyd. 1.1 z dnia 17.12.2019 r."],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Twardość ogólna (z obliczeń) PB01 wyd. 1.1 z dnia 17.12.2019 r. Woda do spozycia przez ludzi, Woda Twardosc ogolna (z obliczen) PB01 wyd. 1.1 z dnia 17.12.2019 r.","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (calculated)","search_en":"Water intended for human consumption, Water Total hardness (calculated) PB01 wyd. 1.1 z dnia 17.12.2019 r.","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 总硬度（由计算得出） PB01 wyd. 1.1 z dnia 17.12.2019 r.","test_object_zh":"生活饮用水、水","methodology_zh":"总硬度（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fc3","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie lotnych chlorowcopochodnych węglowodorów","parameters":[{"name":"Chloroform","range":"(2,0 – 100) µg/l"},{"name":"Bromodichlorometan","range":"(2,0 – 100) µg/l"},{"name":"Dibromochlorometan","range":"(2,0 – 100) µg/l"},{"name":"Bromoform","range":"(2,0 – 100) µg/l"},{"name":"Trichloroeten","range":"(0,2 – 10) µg/l"},{"name":"Tetrachloroeten","range":"(0,2 – 10) µg/l"},{"name":"1,2-dichloroetan","range":"(0,2 – 10) µg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)"],"computed":[],"activity":"Stężenie lotnych chlorowcopochodnych węglowodorów\nZakres:\nChloroform (2,0 – 100) µg/l\nBromodichlorometan (2,0 – 100) µg/l\nDibromochlorometan (2,0 – 100) µg/l\nBromoform (2,0 – 100) µg/l\nTrichloroeten (0,2 – 10) µg/l\nTetrachloroeten (0,2 – 10) µg/l\n1,2-dichloroetan (0,2 – 10) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 3","norm_bases":["PN-EN ISO 10301:2002 Rozdział 3"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie lotnych chlorowcopochodnych węglowodorów\nZakres:\nChloroform (2,0 – 100) µg/l\nBromodichlorometan (2,0 – 100) µg/l\nDibromochlorometan (2,0 – 100) µg/l\nBromoform (2,0 – 100) µg/l\nTrichloroeten (0,2 – 10) µg/l\nTetrachloroeten (0,2 – 10) µg/l\n1,2-dichloroetan (0,2 – 10) µg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją wychwytu elektronów (HS-GC-ECD) PN-EN ISO 10301:2002 Rozdział 3 Woda do spozycia przez ludzi, Woda Stezenie lotnych chlorowcopochodnych weglowodorow\nZakres:\nChloroform (2,0 – 100) µg/l\nBromodichlorometan (2,0 – 100) µg/l\nDibromochlorometan (2,0 – 100) µg/l\nBromoform (2,0 – 100) µg/l\nTrichloroeten (0,2 – 10) µg/l\nTetrachloroeten (0,2 – 10) µg/l\n1,2-dichloroetan (0,2 – 10) µg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja wychwytu elektronow (HS-GC-ECD) PN-EN ISO 10301:2002 Rozdzial 3","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile halogenated hydrocarbons","parameters_en":[{"name":"Chloroform","range":"(2,0 – 100) µg/l"},{"name":"Bromodichloromethane","range":"(2,0 – 100) µg/l"},{"name":"Dibromochloromethane","range":"(2,0 – 100) µg/l"},{"name":"Bromoform","range":"(2,0 – 100) µg/l"},{"name":"Trichloroethene","range":"(0,2 – 10) µg/l"},{"name":"Tetrachloroethene","range":"(0,2 – 10) µg/l"},{"name":"1,2-dichloroethane","range":"(0,2 – 10) µg/l"}],"search_en":"Water intended for human consumption, Water Concentration of volatile halogenated hydrocarbons Headspace gas chromatography with electron capture detection (HS-GC-ECD) Chloroform Bromodichloromethane Dibromochloromethane Bromoform Trichloroethene Tetrachloroethene 1,2-dichloroethane PN-EN ISO 10301:2002 Rozdział 3","technique_en":"Headspace gas chromatography with electron capture detection (HS-GC-ECD)","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 顶空气相色谱-电子捕获检测法（HS-GC-ECD） 三氯甲烷 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 三氯乙烯 四氯乙烯 1,2-二氯乙烷 PN-EN ISO 10301:2002 Rozdział 3","test_object_zh":"生活饮用水、水","parameters_zh":[{"name":"三氯甲烷","range":"(2,0 – 100) µg/l"},{"name":"一溴二氯甲烷","range":"(2,0 – 100) µg/l"},{"name":"二溴一氯甲烷","range":"(2,0 – 100) µg/l"},{"name":"三溴甲烷","range":"(2,0 – 100) µg/l"},{"name":"三氯乙烯","range":"(0,2 – 10) µg/l"},{"name":"四氯乙烯","range":"(0,2 – 10) µg/l"},{"name":"1,2-二氯乙烷","range":"(0,2 – 10) µg/l"}],"technique_zh":"顶空气相色谱-电子捕获检测法（HS-GC-ECD）"},{"_id":"6a8324ec884ede9a1b2c4fc4","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Suma THM (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma THM (z obliczeń)","reference":"PN-EN ISO 10301:2002 Rozdział 3","norm_bases":["PN-EN ISO 10301:2002 Rozdział 3"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Suma THM (z obliczeń) PN-EN ISO 10301:2002 Rozdział 3 Woda do spozycia przez ludzi, Woda Suma THM (z obliczen) PN-EN ISO 10301:2002 Rozdzial 3","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of THM (calculated)","search_en":"Water intended for human consumption, Water Sum of THM (calculated) PN-EN ISO 10301:2002 Rozdział 3","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 三卤甲烷总量（由计算得出） PN-EN ISO 10301:2002 Rozdział 3","test_object_zh":"生活饮用水、水","methodology_zh":"三卤甲烷总量（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fc5","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)","reference":"PN-EN ISO 10301:2002 Rozdział 3","norm_bases":["PN-EN ISO 10301:2002 Rozdział 3"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Suma trichloroetenu i tetrachloroetenu (z obliczeń) PN-EN ISO 10301:2002 Rozdział 3 Woda do spozycia przez ludzi, Woda Suma trichloroetenu i tetrachloroetenu (z obliczen) PN-EN ISO 10301:2002 Rozdzial 3","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of trichloroethene and tetrachloroethene (calculated)","search_en":"Water intended for human consumption, Water Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 10301:2002 Rozdział 3","test_object_en":"Water intended for human consumption, Water","search_zh":"生活饮用水、水 三氯乙烯与四氯乙烯总量（由计算得出） PN-EN ISO 10301:2002 Rozdział 3","test_object_zh":"生活饮用水、水","methodology_zh":"三氯乙烯与四氯乙烯总量（由计算得出）"},{"_id":"6a8324ec884ede9a1b2c4fc6","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda, Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a8324ec884ede9a1b2c4fc7","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda, Wody opadowe, wody roztopowe, Ścieki","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,50 – 50,0) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,50 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia Fizyko-Chemiczna Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Wody opadowe, wody roztopowe, Ścieki Indeks oleju mineralnego\nZakres (0,50 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Wody opadowe, wody roztopowe, Scieki Indeks oleju mineralnego\nZakres (0,50 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,50 – 50,0) mg/l"}],"search_en":"Water, Rainwater, snowmelt water, Wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, Rainwater, snowmelt water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 50,0) mg/l"}],"search_zh":"矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数"},{"_id":"6a8324ec884ede9a1b2c4fc8","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fc9","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fca","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["microbiology","water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fcb","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fcc","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a8324ec884ede9a1b2c4fcd","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 肠道肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"肠道肠球菌数"},{"_id":"6a8324ec884ede9a1b2c4fce","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fcf","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fd0","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a8324ec884ede9a1b2c4fd1","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pozywka A-BCYE Matryca A, Procedura 7, Pozywka C-GVPC Matryca B, Procedura 7, Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8324ec884ede9a1b2c4fd2","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd3","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["microbiology","water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd4","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd5","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water","search_zh":"水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a8324ec884ede9a1b2c4fd6","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd7","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22 °C","search_en":"Water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","methodology_zh":"22 °C 微生物总数","search_zh":"水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd8","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36 °C","search_en":"Water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","methodology_zh":"36 °C 微生物总数","search_zh":"水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fd9","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a8324ec884ede9a1b2c4fda","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pożywka A-BCYE Matryca A, Procedura 7, Pożywka C-GVPC Matryca B, Procedura 7, Pożywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella sp. Matryca A, Procedura 5, Pozywka A-BCYE Matryca A, Procedura 7, Pozywka C-GVPC Matryca B, Procedura 7, Pozywka C-GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a8324ec884ede9a1b2c4fdb","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań fizykochemicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizykochemicznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań fizykochemicznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan fizykochemicznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for physicochemical testing","search_en":"Rainwater and snowmelt water Sampling for physicochemical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater and snowmelt water","search_zh":"雨水与融雪水 用于理化检验的采样 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法","test_object_zh":"雨水与融雪水","methodology_zh":"用于理化检验的采样"},{"_id":"6a8324ec884ede9a1b2c4fdc","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a8324ec884ede9a1b2c4fdd","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 – 50,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0,0 – 50,0) °C PN-77/C-04584 Scieki Temperatura\nZakres (0,0 – 50,0) °C PN-77/C-04584","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 – 50,0) °C"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 – 50,0) °C"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a8324ec884ede9a1b2c4fde","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a8324ec884ede9a1b2c4fdf","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(10 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (10 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (10 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (10 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(10 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(10 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a8324ec884ede9a1b2c4fe0","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(25 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (25 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (25 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (25 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(25 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(25 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a8324ec884ede9a1b2c4fe1","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"chlorki","range":"(10 − 2000) mg/l"},{"name":"siarczany","range":"(10 − 2000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nchlorki (10 − 2000) mg/l\nsiarczany (10 − 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów:\nZakres:\nchlorki (10 − 2000) mg/l\nsiarczany (10 − 2000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow:\nZakres:\nchlorki (10 − 2000) mg/l\nsiarczany (10 − 2000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"chlorides","range":"(10 − 2000) mg/l"},{"name":"sulfates","range":"(10 − 2000) mg/l"}],"search_en":"Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度：","search_zh":"污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"氯化物","range":"(10 − 2000) mg/l"},{"name":"硫酸盐","range":"(10 − 2000) mg/l"}]},{"_id":"6a8324ec884ede9a1b2c4fe2","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8324ec884ede9a1b2c4fe3","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(6 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (6 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(6 – 1000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(6 – 1000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a8324ec884ede9a1b2c4fe4","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"chrom ogólny","range":"(0,050 – 10,0) mg/l"},{"name":"cynk","range":"(0,050 – 10,0) mg/l"},{"name":"kadm","range":"(0,050 – 10,0) mg/l"},{"name":"glin","range":"(0,050 – 20,0) mg/l"},{"name":"mangan","range":"(0,050 – 20,0) mg/l"},{"name":"miedź","range":"(0,050 – 10,0) mg/l"},{"name":"nikiel","range":"(0,050 – 10,0) mg/l"},{"name":"ołów","range":"(0,050 – 10,0) mg/l"},{"name":"żelazo","range":"(0,050 – 20,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nchrom ogólny (0,050 – 10,0) mg/l\ncynk (0,050 – 10,0) mg/l\nkadm (0,050 – 10,0) mg/l\nglin (0,050 – 20,0) mg/l\nmangan (0,050 – 20,0) mg/l\nmiedź (0,050 – 10,0) mg/l\nnikiel (0,050 – 10,0) mg/l\nołów (0,050 – 10,0) mg/l\nżelazo (0,050 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nchrom ogólny (0,050 – 10,0) mg/l\ncynk (0,050 – 10,0) mg/l\nkadm (0,050 – 10,0) mg/l\nglin (0,050 – 20,0) mg/l\nmangan (0,050 – 20,0) mg/l\nmiedź (0,050 – 10,0) mg/l\nnikiel (0,050 – 10,0) mg/l\nołów (0,050 – 10,0) mg/l\nżelazo (0,050 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nchrom ogolny (0,050 – 10,0) mg/l\ncynk (0,050 – 10,0) mg/l\nkadm (0,050 – 10,0) mg/l\nglin (0,050 – 20,0) mg/l\nmangan (0,050 – 20,0) mg/l\nmiedz (0,050 – 10,0) mg/l\nnikiel (0,050 – 10,0) mg/l\nolow (0,050 – 10,0) mg/l\nzelazo (0,050 – 20,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"total chromium","range":"(0,050 – 10,0) mg/l"},{"name":"zinc","range":"(0,050 – 10,0) mg/l"},{"name":"cadmium","range":"(0,050 – 10,0) mg/l"},{"name":"aluminium","range":"(0,050 – 20,0) mg/l"},{"name":"manganese","range":"(0,050 – 20,0) mg/l"},{"name":"copper","range":"(0,050 – 10,0) mg/l"},{"name":"nickel","range":"(0,050 – 10,0) mg/l"},{"name":"lead","range":"(0,050 – 10,0) mg/l"},{"name":"iron","range":"(0,050 – 20,0) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) total chromium zinc cadmium aluminium manganese copper nickel lead iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"总铬","range":"(0,050 – 10,0) mg/l"},{"name":"锌","range":"(0,050 – 10,0) mg/l"},{"name":"镉","range":"(0,050 – 10,0) mg/l"},{"name":"铝","range":"(0,050 – 20,0) mg/l"},{"name":"锰","range":"(0,050 – 20,0) mg/l"},{"name":"铜","range":"(0,050 – 10,0) mg/l"},{"name":"镍","range":"(0,050 – 10,0) mg/l"},{"name":"铅","range":"(0,050 – 10,0) mg/l"},{"name":"铁","range":"(0,050 – 20,0) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 总铬 锌 镉 铝 锰 铜 镍 铅 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a8324ec884ede9a1b2c4fe5","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,20 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Scieki Stezenie azotu amonowego\nZakres (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 1000) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Ion chromatography with conductometric detection (IC-CD) Range PN-EN ISO 14911:2002","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 1000) mg/l"}],"search_zh":"污水 氨氮浓度 离子色谱-电导检测法（IC-CD） 范围 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水"},{"_id":"6a8324ec884ede9a1b2c4fe6","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Wastewater, Water Total phosphorus concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater, Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"废水、水 总磷浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"废水、水"},{"_id":"6a8324ec884ede9a1b2c4fe7","lab_id":"69ad52a3de79e566650fb99d","country":"PL","accr_number":"AB 1800","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001","norm_bases":["PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001"],"lab_section":"Pracownia Fizyko-Chemiczna Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu ogólnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001 Scieki, Woda Stezenie azotu ogolnego\nZakres (1,0 – 150) mg/l\nMetoda spektrofotometryczna PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testow Merck nr 1.14763.0001 i 1.114537.0001","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"search_en":"Wastewater, Water Total nitrogen concentration Spectrophotometric method Range PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"废水、水 总氮浓度 分光光度法 范围 PB20 wyd. 2.1 z dnia 20.01.2023 r. na podstawie testów Merck nr 1.14763.0001 i 1.114537.0001","technique_zh":"分光光度法","test_object_zh":"废水、水"}],"has_pdf":true}