🇵🇱 „WODOCIĄGI KIELECKIE” Sp. z o.o. PL
Water & wastewaterMicrobiology
„WODOCIĄGI KIELECKIE” Sp. z o.o. is a laboratory accredited by PCA under number AB 1779 (Kielce, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, water, Wastewater, Wastewater, including rainwater and snowmelt water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1779
- Methods in scope: 29
- Types of test objects: 7
- Techniques used: 13
- City: Kielce, Poland
- Accreditation number
- AB 1779
- Accreditation body
- PCA
- Address
- ul. Krakowska 64, 25-701 Kielce, CENTRALNE LABORATORIUM WODNO-ŚCIEKOWE, ul. Przemysłowa 93, 26-052 Nowiny
- City
- Kielce, Poland
What this laboratory tests (7)
- Water intended for human consumption — 15 methods
- Wastewater, water — 7 methods
- Wastewater — 2 methods
- Wastewater, including rainwater and snowmelt water — 2 methods
- Water — 1 method
- Water intended for human consumption, wastewater — 1 method
- Water, water intended for human consumption, wastewater — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 7 methods
- Titrimetric method — 4 methods
- Membrane filtration method — 3 methods
- Gravimetric method — 2 methods
- Conductometric method — 1 method
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 1 method
- Flame atomic absorption spectrometry (FAAS) — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Optical method — 1 method
- Plate method (pour plate) — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of water/of the water sample taken Range (0 – 40,0)°C |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6 | ||
| 3 | Water intended for human consumption | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 metoda D | |
| 4 | Water intended for human consumption | Turbidity Range (0,20 – 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 5 | Water intended for human consumption | Electrical conductivity Range (148 – 2760) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 6 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (5 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 7 | Water intended for human consumption | Manganese concentration Range (5 – 140) μg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 8 | Water intended for human consumption | Zinc concentration Range (0,05 – 1,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 metoda A | |
| 9 | Water intended for human consumption | Chloride concentration Range (5 − 250) mg/l |
Titrimetric method | PN ISO 9297:1994 | |
| 10 | Water intended for human consumption | Nitrate concentration Range (0,44 − 70) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 11 | Water intended for human consumption | Nitrite concentration Range (0,04 – 0,82) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 12 | Water intended for human consumption | Total count of microorganisms at 22°C and 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 13 | Water intended for human consumption | Coliform bacteria count and count of, Escherichia coli | Membrane filtration method | PN-EN ISO 9308-1:2014-12 + A1:2017-04 | |
| 14 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 15 | Water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 16 | Water intended for human consumption, wastewater | Iron concentration Range (50 – 10000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06 | |
| 17 | Water, water intended for human consumption, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 18 | Wastewater, including rainwater and snowmelt water | Sampling for chemical and physical testing Temperature of wastewater/collected wastewater sample Range (0 – 40,0)°C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 19 | Wastewater, including rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 20 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2 | ||
| 21 | Wastewater, water | Chemical oxygen demand COD-Cr Range (10,0 – 12000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 22 | Wastewater, water | Total phosphorus concentration Range (0,10 – 60,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010 | |
| 23 | Wastewater, water | Nitrate nitrogen concentration Range (0,050 – 30,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 24 | Wastewater, water | Nitrite nitrogen concentration Range (0,0020 – 2,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 25 | Wastewater, water | Kjeldahl nitrogen concentration Range (1,0 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 26 | Wastewater, water | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 27 | Wastewater, water | Biochemical oxygen demand BOD5 Range (1 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 28 | Wastewater | Sulfate concentration Range (10 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 29 | Wastewater | Chloride concentration Range (20 – 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
Reference standards (28)
PN ISO 9297:1994
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06
PN-ISO 8288:2002 metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994