🇵🇱 „WODOCIĄGI KIELECKIE” Sp. z o.o. PL

PCA AB 1779 • Kielce, Poland • 29 methods

Water & wastewaterMicrobiology

„WODOCIĄGI KIELECKIE” Sp. z o.o. is a laboratory accredited by PCA under number AB 1779 (Kielce, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, water, Wastewater, Wastewater, including rainwater and snowmelt water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 1779
  • Methods in scope: 29
  • Types of test objects: 7
  • Techniques used: 13
  • City: Kielce, Poland
Accreditation number
AB 1779
Accreditation body
PCA
Address
ul. Krakowska 64, 25-701 Kielce, CENTRALNE LABORATORIUM WODNO-ŚCIEKOWE, ul. Przemysłowa 93, 26-052 Nowiny
City
Kielce, Poland

What this laboratory tests (7)

Analytical techniques used (13)

Accreditation scope — test methods (29)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing Temperature of water/of the water sample taken
Range (0 – 40,0)°C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
2 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6
3 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 metoda D
4 Water intended for human consumption Turbidity
Range (0,20 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
5 Water intended for human consumption Electrical conductivity
Range (148 – 2760) μS/cm
Conductometric method PN-EN 27888:1999
6 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
7 Water intended for human consumption Manganese concentration
Range (5 – 140) μg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
8 Water intended for human consumption Zinc concentration
Range (0,05 – 1,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 metoda A
9 Water intended for human consumption Chloride concentration
Range (5 − 250) mg/l
Titrimetric method PN ISO 9297:1994
10 Water intended for human consumption Nitrate concentration
Range (0,44 − 70) mg/l
Spectrophotometric method PN-82/C-04576.08
11 Water intended for human consumption Nitrite concentration
Range (0,04 – 0,82) mg/l
Spectrophotometric method PN-EN 26777:1999
12 Water intended for human consumption Total count of microorganisms at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004
13 Water intended for human consumption Coliform bacteria count and count of, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
14 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
15 Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
16 Water intended for human consumption, wastewater Iron concentration
Range (50 – 10000) μg/l
Spectrophotometric method PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06
17 Water, water intended for human consumption, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
18 Wastewater, including rainwater and snowmelt water Sampling for chemical and physical testing
Temperature of wastewater/collected wastewater sample Range (0 – 40,0)°C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
19 Wastewater, including rainwater and snowmelt water Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2
21 Wastewater, water Chemical oxygen demand
COD-Cr Range (10,0 – 12000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
22 Wastewater, water Total phosphorus concentration
Range (0,10 – 60,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010
23 Wastewater, water Nitrate nitrogen concentration
Range (0,050 – 30,0) mg/l
Spectrophotometric method PN-82/C-04576.08
24 Wastewater, water Nitrite nitrogen concentration
Range (0,0020 – 2,0) mg/l
Spectrophotometric method PN-EN 26777:1999
25 Wastewater, water Kjeldahl nitrogen concentration
Range (1,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
26 Wastewater, water Total nitrogen concentration (calculated) PN-73/C-04576/14
27 Wastewater, water Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
28 Wastewater Sulfate concentration
Range (10 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
29 Wastewater Chloride concentration
Range (20 – 5000) mg/l
Titrimetric method PN-ISO 9297:1994

Reference standards (28)

PN ISO 9297:1994
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06
PN-ISO 8288:2002 metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994