{"lab":{"_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","address":"ul. Krakowska 64, 25-701 Kielce, CENTRALNE LABORATORIUM WODNO-ŚCIEKOWE, ul. Przemysłowa 93, 26-052 Nowiny","categories":["water","microbiology"],"city":"Kielce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"„WODOCIĄGI KIELECKIE” Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1779.pdf"],"scope_summary":"","search_text":"„wodociągi kieleckie” sp. z o.o. ul. krakowska 64, 25-701 kielce, centralne laboratorium wodno-ściekowe, ul. przemysłowa 93, 26-052 nowiny water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:54.748Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:54.748Z","location":{"type":"Point","coordinates":[20.6286,50.8661]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201779,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Physical properties and sampling of water, drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"}],"issue":{"no":"5","date":"26.02.2025"},"parse_date":"2026-07-20T07:09:29.354Z","parse_source":"script-pdfplumber","map_coord":[50.862073,20.602784],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":29,"microbiology":2},"category_scores":{"water":27.13,"microbiology":0.13},"has_zh":true},"methods":[{"_id":"6a5dc9a9f1c10c8ce8259f0f","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(0 – 40,0)°C"}],"parameters_en":[{"name":"Range","range":"(0 – 40,0)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0 – 40,0)°C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (0 – 40,0)°C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura wody/pobranej probki wody\nZakres (0 – 40,0)°C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of water/of the water sample taken Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(0 – 40,0)°C"}],"search_zh":"生活饮用水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5dc9a9f1c10c8ce8259f10","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.3; 4.4.4; 4.4.5; 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f11","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 metoda D","norm_bases":["PN-EN ISO 7887:2012 metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 metoda D","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 metoda D","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f12","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f13","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(148 – 2760) μS/cm"}],"parameters_en":[{"name":"Range","range":"(148 – 2760) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 2760) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 2760) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 2760) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148 – 2760) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f14","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(5 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f15","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(5 – 140) μg/l"}],"parameters_en":[{"name":"Range","range":"(5 – 140) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (5 – 140) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (5 – 140) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda do spozycia przez ludzi Stezenie manganu\nZakres (5 – 140) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Manganese concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) Range PN-EN ISO 15586:2005","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(5 – 140) μg/l"}],"search_zh":"生活饮用水 锰浓度 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f16","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie cynku","methodology_en":"Zinc concentration","parameters":[{"name":"Zakres","range":"(0,05 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie cynku\nZakres (0,05 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie cynku\nZakres (0,05 – 1,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda do spozycia przez ludzi Stezenie cynku\nZakres (0,05 – 1,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Zinc concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 metoda A","parameters_zh":[{"name":"范围","range":"(0,05 – 1,0) mg/l"}],"search_zh":"生活饮用水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水","methodology_zh":"锌浓度"},{"_id":"6a5dc9a9f1c10c8ce8259f17","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5 − 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(5 − 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5 − 250) mg/l\nMetoda miareczkowa","reference":"PN ISO 9297:1994","norm_bases":["PN ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 − 250) mg/l\nMetoda miareczkowa PN ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 − 250) mg/l\nMetoda miareczkowa PN ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 − 250) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f18","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,44 − 70) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,44 − 70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,44 − 70) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,44 − 70) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,44 − 70) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 − 70) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f19","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,04 – 0,82) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 – 0,82) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,04 – 0,82) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,04 – 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,04 – 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 0,82) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f1a","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22°C i 36°C","methodology_en":"Total count of microorganisms at 22°C and 36°C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C i 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C i 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C i 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Total count of microorganisms at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f1b","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli i liczba, Escherichia coli","methodology_en":"Coliform bacteria count and count of, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli i liczba, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli i liczba, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli i liczba, Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["microbiology","water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coliform bacteria count and count of, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f1c","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f1d","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a5dc9a9f1c10c8ce8259f1e","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, ścieki","test_object_en":"Water intended for human consumption, wastewater","methodology":"Stężenie żelaza","methodology_en":"Iron concentration","parameters":[{"name":"Zakres","range":"(50 – 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(50 – 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza\nZakres (50 – 10000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi, ścieki Stężenie żelaza\nZakres (50 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06 Woda do spozycia przez ludzi, scieki Stezenie zelaza\nZakres (50 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption, wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(50 – 10000) μg/l"}],"search_zh":"铁浓度 分光光度法 范围 PN-ISO 6332:2001 p. 7.1.1 + Ap1:2016-06","technique_zh":"分光光度法"},{"_id":"6a5dc9a9f1c10c8ce8259f1f","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9a9f1c10c8ce8259f20","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, w tym wody opadowe i roztopowe","test_object_en":"Wastewater, including rainwater and snowmelt water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieków/pobranej próbki ścieków"},{"name":"Zakres","range":"(0 – 40,0)°C"}],"parameters_en":[{"name":"Temperature of wastewater/collected wastewater sample"},{"name":"Range","range":"(0 – 40,0)°C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (0 – 40,0)°C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, w tym wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/pobranej próbki ścieków\nZakres (0 – 40,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki, w tym wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow/pobranej probki sciekow\nZakres (0 – 40,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, including rainwater and snowmelt water Sampling for chemical and physical testing Manual method; Automatic method Temperature of wastewater/collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(0 – 40,0)°C"}],"search_zh":"化学与物理检测用样品采集 手动法；自动法 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法"},{"_id":"6a5dc9a9f1c10c8ce8259f21","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, w tym wody opadowe i roztopowe","test_object_en":"Wastewater, including rainwater and snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, w tym wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, w tym wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, including rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a5dc9a9f1c10c8ce8259f22","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2","norm_bases":["PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wylaczeniem punktu 7.5, 7.6, 8.2","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 +Ap11:2020-10 z wyłączeniem punktu 7.5, 7.6, 8.2","test_object_zh":"水"},{"_id":"6a5dc9a9f1c10c8ce8259f23","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 12000) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 12000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 12000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 12000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 12000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 12000) mg/l O2"}],"search_zh":"废水、水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9a9f1c10c8ce8259f24","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,10 – 60,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 60,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 60,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie fosforu ogólnego\nZakres (0,10 – 60,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010 Scieki, woda Stezenie fosforu ogolnego\nZakres (0,10 – 60,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 60,0) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 8 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f25","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,050 – 30,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu azotanowego\nZakres (0,050 – 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, woda Stezenie azotu azotanowego\nZakres (0,050 – 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 30,0) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f26","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,0020 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,0020 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, woda Stezenie azotu azotynowego\nZakres (0,0020 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 2,0) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f27","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, woda Stezenie azotu Kjeldahla\nZakres (1,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f28","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki, woda Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"废水、水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f29","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki, woda","test_object_en":"Wastewater, water","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater, water Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"废水、水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水"},{"_id":"6a5dc9a9f1c10c8ce8259f2a","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9a9f1c10c8ce8259f2b","lab_id":"69ad52a3de79e566650fb973","country":"PL","accr_number":"AB 1779","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(20 – 5000) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (20 – 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków\nZakres (20 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (20 – 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(20 – 5000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"}],"has_pdf":true}