🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL
Water & wastewaterEnvironmentElectronics & EMC
GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 176 (Warszawa, Poland). Its accreditation scope covers 120 test methods in the following areas: Water & wastewater, Environment, Electronics & EMC. Test objects include: Water, wastewater, Water and wastewater, O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie ka…, Soil, ground. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Direct measurement method.
At a glance
- Accreditation number: PCA AB 176
- Methods in scope: 120
- Types of test objects: 35
- Techniques used: 20
- City: Warszawa, Poland
- Accreditation number
- AB 176
- Accreditation body
- PCA
- Address
- ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KRAKOWIE
- City
- Warszawa, Poland
What this laboratory tests (35)
- Water, wastewater — 32 methods
- Water and wastewater — 16 methods
- O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów — 12 methods
- Soil, ground — 12 methods
- Water — 12 methods
- General environment — 11 methods
- Sewage sludge — 10 methods
- Wastewater — 9 methods
- Środowisko — 8 methods
- przemysłowych — 5 methods
- kod 19 08 05 — 4 methods
- Odpady O): — 4 methods
- Odpady O): kod 17 05 04 — 4 methods
- - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów — 3 methods
- - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych — 3 methods
- and 20 more
Analytical techniques used (20)
- Spectrophotometric method — 21 methods
- Gravimetric method — 13 methods
- Direct measurement method — 12 methods
- Continuous flow analysis (CFA) with spectrophotometric detection — 10 methods
- Electrochemical method — 6 methods
- Titrimetric method — 6 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 5 methods
- Potentiometric method — 5 methods
- Optical method — 4 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 3 methods
- Ion chromatography with conductometric detection (IC-CD) — 3 methods
- Atomic absorption spectrometry with amalgamation technique — 2 methods
- Atomic fluorescence spectrometry — 2 methods
- Infrared spectrometry method (IR) — 2 methods
- Conductometric method — 1 method
- and 5 more
Laboratory sections (4)
- Pracownia w Tarnowie — 42 methods
- Pracownia Terenowa — 33 methods
- Pracownia w Nowym Sączu — 32 methods
- Pracownia w Krakowie — 13 methods
Laboratory locations
- CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W KRAKOWIE — ul. Półłanki 76E
- Pracownia w Krakowie — ul. Półłanki 76E, 30-740 Kraków
- Pracownia Terenowa — ul. Półłanki 76E, 30-740 Kraków
- Pracownia w Tarnowie — ul. Krasińskiego 7a, 33-100 Tarnów
- Pracownia w Nowym Sączu — ul. Fabryczna 11, 33-300 Nowy Sącz
Accreditation scope — test methods (120)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Pracownia w Krakowie | |||||
| 1 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (0,50 - 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025 | |
| 2 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (3 – 1000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 3 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 4 | Water, wastewater | Nitrite nitrogen concentration Range (0,0010 – 2,5) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 5 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,50 – 500) mg/l |
Potentiometric titration method | PN-EN 25663:2001 | |
| 6 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wydanie 1 z dnia 16.01.2026 r. | ||
| 7 | Water, wastewater | Chemical oxygen demand – COD-Cr Range (5,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 8 | Water, wastewater | Total phosphorus concentration Range (0,015 – 50) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | |
| 9 | Water | Element concentrations: silver (0,5 – 50) µg/l aluminium (1 – 1000) µg/l arsenic (0,5 – 50) µg/l boron (1 – 1000) µg/l barium (1 – 1000) µg/l beryllium (0,2 – 50) µg/l cadmium (0,02 – 10) µg/l cobalt (0,5 – 50) µg/l chromium (0,1 – 50) µg/l copper (0,5 – 50) µg/l iron (1 – 1000) µg/l manganese (1 – 1000) µg/l molybdenum (0,5 – 50) µg/l nickel (0,5 – 50) µg/l lead (0,2 – 50) µg/l antimony (0,5 – 50) µg/l selenium (1 – 50) µg/l tin (0,5 – 50) µg/l titanium (0,5 – 50) µg/l thallium (0,5 – 50) µg/l vanadium (0,5 – 50) µg/l zinc (1 – 1000) µg/l |
Inductively coupled plasma mass spectrometry (ICP-MS) | PN-EN ISO 17294-2:2024-04 | |
| 10 | Water | Mercury concentration Range (0,010 – 0,10) µg/l |
Atomic fluorescence spectrometry | PN-EN ISO 17852:2009 | |
| 11 | Wastewater | Nitrate nitrogen concentration Range (0,10 – 150) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 12 | Wastewater | Chromium(VI) concentration Range (0,010 – 10) mg/l |
Spectrophotometric method | PN-77/C-04604.08 | |
| 13 | Wastewater | Mercury concentration Range (0,010 – 0,50) µg/l |
Atomic fluorescence spectrometry | PN-EN ISO 17852:2009 | |
| Pracownia Terenowa | |||||
| 14 | General environment - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych |
A-weighted equivalent sound pressure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | |
| 15 | General environment - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych |
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F | ||
| 16 | General environment - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych |
A-weighted equivalent sound pressure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | |
| 17 | General environment - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych |
A-weighted sound exposure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | |
| 18 | General environment - hałas impulsowy pochodzący od instalacji, urządzeń i zakładów przemysłowych |
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) | ||
| 19 | General environment - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych |
A-weighted equivalent sound pressure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H | |
| 20 | General environment - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych |
A-weighted sound exposure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H | |
| 21 | General environment - hałas pochodzący od dróg, linii kolejowych, linii tramwajowych |
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H | ||
| 22 | General environment - hałas pochodzący od lotnisk |
A-weighted equivalent sound pressure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H | |
| 23 | General environment - hałas pochodzący od lotnisk |
A-weighted sound exposure level Range (22,0 – 130,0) dB |
Direct measurement method | Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H | |
| 24 | General environment - hałas pochodzący od lotnisk |
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H | ||
| 25 | Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych |
Electric field strength at 50 Hz frequency Range (1,0 – 30000) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 26 | Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych |
Magnetic flux density at 50 Hz frequency Range od 1 µT do 10 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 27 | Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych |
Magnetic field strength at 50 Hz frequency (calculated) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 28 | Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe |
Electric field strength:
- w zakresie częstotliwości od 80 MHz do 60 GHz Range (0,5 – 300) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 29 | Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe |
Electric field strength:
- w zakresie częstotliwości od 420 MHz do 6 GHz Range (0,05 – 200) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 30 | Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe |
Magnetic field strength:
- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 31 | Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne |
Electric field strength:
- w zakresie częstotliwości od 420 MHz do 6 GHz Range (0,05 – 200) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | |
| 32 | Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne |
Magnetic field strength:
- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń) Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska. |
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) | ||
| 33 | Water | Sampling for chemical and physical testing | PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3 | ||
| 34 | Water | Temperature Range (1,0 – 50,0) oC |
PN-77/C-04584 | ||
| 35 | Water | Dissolved oxygen concentration Range (0,5 – 16,0) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 36 | Water | Oxygen saturation Range (5 – 180) % |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 37 | Water | Dissolved oxygen concentration Range (0,5 – 16,0) mg/l O2 |
Optical method | ISO 17289:2014 | |
| 38 | Water | Oxygen saturation Range (5 – 180) % |
Optical method | ISO 17289:2014 | |
| 39 | Wastewater, rainwater, snowmelt water | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 40 | Wastewater, rainwater, snowmelt water | Temperature Range (1,0 – 50,0) oC |
PN-77/C-04584 | ||
| 41 | Sewage sludge | Sampling for chemical, physical and biological testing | PN-EN ISO 5667-13:2011 | ||
| 42 | Bottom sediment | Sampling for chemical and physical testing | PN-ISO 4364:2005 | ||
| 43 | Soil, ground | Sampling for chemical and physical testing | PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 | ||
| 44 | Water, wastewater | pH Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 45 | Water, wastewater | Electrical conductivity Range (84,0 – 12800) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 46 | Waste | Intervention testing (according to Programme DAB-11) | PB-11/CLB wydanie 1 z dnia 25.09.2023 r. | ||
| Pracownia w Tarnowie | |||||
| 47 | Sewage sludge | pH – in H2O Range (4,0 – 12,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 48 | Soil, ground | pH – in H2O, pH – in KCl Range (4,0 – 12,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 49 | Water, wastewater | Dissolved solids Range (50 – 2000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 50 | Water, wastewater | Biochemical oxygen demand - BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 51 | Water, wastewater | Biochemical oxygen demand - BOD5, Range (1,0 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 52 | Water, wastewater | Ammonium nitrogen concentration Range (0,04 – 250) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 11732:2007 | |
| 53 | Water, wastewater | Ammonium ion (ammonia) concentration (calculated) | PN-EN ISO 11732:2007 | ||
| 54 | Water, wastewater | Nitrite nitrogen concentration Range (0,0020 – 2,5) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 13395:2001 | |
| 55 | Water, wastewater | Nitrite concentration Range (0,0070 – 8,2) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 13395:2001 | |
| 56 | Water, wastewater | Nitrate nitrogen concentration Range (0,20 – 250) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 13395:2001 | |
| 57 | Water, wastewater | Nitrate concentration Range (0,90 – 1100) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 13395:2001 | |
| 58 | Water, wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wydanie 1 z dnia 16.01.2026 r. | ||
| 59 | Water, wastewater | Free cyanide concentration Range (0,01 – 1,0) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 14403-2:2012 | |
| 60 | Water, wastewater | Total cyanide concentration Range (0,01 – 1,0) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 14403-2:2012 | |
| 61 | Water, wastewater | Combined cyanide concentration (calculated) | PN-EN ISO 14403-2:2012 | ||
| 62 | Water, wastewater | Total phosphorus concentration Range (0,010 – 50) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010 | |
| 63 | Water, wastewater | Phosphate concentration Range (0,030 – 300) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 15681-2:2019-02 | |
| 64 | Water, wastewater | Chemical oxygen demand – COD-Cr Range (7,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 65 | Water, wastewater | Phenol index Range (0,0010 – 5,0) mg/l |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 14402:2004 | |
| 66 | Water, wastewater | Formaldehyde concentration Range (0,010 – 2,0) mg/l |
Spectrophotometric method | PN-71/C-04593 | |
| 67 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,50 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 68 | Water, wastewater | Concentration:
- ogólnego węgla organicznego
- rozpuszczonego węgla organicznego Range (1,0 –1000) mg/l |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | |
| 69 | Water, wastewater | Concentration of polycyclic aromatic hydrocarbons (PAH) Anthracene (0,005 – 0,10) µg/l fluoranthene (0,005 – 0,10) µg/l naphthalene (0,005 – 0,10) µg/l benzo(b)fluoranthene (0,005 – 0,10) µg/l benzo(k)fluoranthene (0,005 – 0,10) µg/l benzo(g, h, i)perylene (0,001 – 0,010) µg/l indeno(1, 2, 3-cd)piren (0,001 – 0,010) µg/l dibenzo(a,h)anthracene (0,001 – 0,010) µg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-EN ISO 17993:2005 | |
| 70 | Water, wastewater | Stężenie fosforu ogólnego: Range (0,010 – 50) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 71 | Water, wastewater, wody opadowe, wody roztopowe |
Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 72 | Water, wastewater, wody opadowe, wody roztopowe |
Mineral oil index Range (0,05 – 50,0) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 73 | Water | Concentration of polycyclic aromatic hydrocarbons (PAH) benzo(a)pyrene (0,00011 – 0,10) µg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-EN ISO 17993:2005 | |
| 74 | Wastewater | Concentration of polycyclic aromatic hydrocarbons (PAH) benzo(a)pyrene (0,005 – 0,10) µg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PN-EN ISO 17993:2005 | |
| 75 | Wastewater | Element concentration antimony (0,050 – 100) mg/l arsenic (0,010 – 100) mg/l barium (0,050 – 100) mg/l beryllium (0,050 – 100) mg/l boron (0,050 – 100) mg/l total chromium (0,050 – 100) mg/l tin (0,050 – 100) mg/l zinc (0,050 – 100) mg/l aluminium (0,050 – 100) mg/l cadmium (0,010 – 100) mg/l cobalt (0,010 – 100) mg/l manganese (0,050 – 100) mg/l copper (0,010 – 100) mg/l molybdenum (0,050 – 100) mg/l nickel (0,010 – 100) mg/l lead (0,010 – 100) mg/l potassium (1,0 – 1000) mg/l selenium (0,050 – 100) mg/l sodium (1,0 – 1000) mg/l silver (0,025 – 100) mg/l thallium (0,050 – 100) mg/l titanium (0,050 – 100) mg/l vanadium (0,050 – 100) mg/l iron (0,050 – 100) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 76 | Sewage sludge | Dry residue (dry matter) Range (5,0 – 99,9) % |
Gravimetric method | PN-EN ISO 11465:2026-03 metoda A | |
| 77 | Sewage sludge | Loss on ignition of dry matter (organic matter content) Range (2,0 – 95,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 78 | Soil, ground | Dry matter Range (30,0 – 99,9) % |
Gravimetric method | PN-EN ISO 11465:2026-03 metoda A | |
| 79 | Soil, ground | Water content (calculated) | PN-EN ISO 11465:2026-03 metoda A | ||
| 80 | Soil, ground | Element content arsenic (0,50 – 1000) mg/kg barium (2,50 – 1000) mg/kg total chromium (2,50 – 1000) mg/kg tin (0,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg cobalt (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg molybdenum (0,50 – 1000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B | |
| 81 | Sewage sludge | Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp. Range od 1 szt./50 g |
Flotation method, microscopic | PB-09/CLB wydanie 1 z dnia 30.05.2022 | |
| 82 | Soil, ground Odpady O): kod 17 05 04 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Total dissolved solids content (TDS) Range (500 – 20000) mg/kg |
Gravimetric method | PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
| 83 | Soil, ground Odpady O): kod 17 05 04 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Dissolved organic carbon (DOC) content Range (10 – 10000) mg/kg |
Infrared spectrometry method (IR) | PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
| 84 | Soil, ground Odpady O): kod 17 05 04 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Phenol index Range (0,01 – 50) mg/kg |
Continuous flow analysis (CFA) with spectrophotometric detection | PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
| 85 | Odpady O): kod 17 05 04 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Element content arsenic (0,50 – 1000) mg/kg barium (2,50 – 1000) mg/kg total chromium (2,50 – 1000) mg/kg tin (0,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg cobalt (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg molybdenum (0,50 – 1000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B | |
| 86 | Sewage sludge Waste O): code 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Element content chromium (2,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg total phosphorus (0,025 – 4,0) % magnesium (0,010 – 1,0) % calcium (0,025 – 10,0) % |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B | |
| 87 | Soil, ground Odpady O): kod 17 05 04*) O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów *) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. |
Mercury content Range (0,001 – 5,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
| 88 | Soil, ground, sewage sludge*) *) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. |
Mercury content Range (0,010 – 5,0) mg/kg |
Atomic absorption spectrometry with amalgamation technique | PB-04/KR wydanie 1 z dnia 02.03.2020 r. | |
| Pracownia w Nowym Sączu | |||||
| 89 | Water | Anion concentrations: fluorides (0,050 – 0,60) mg/l chlorides (0,20 – 3000) mg/l nitrates (0,20 – 100) mg/l nitrate nitrogen (0,050 – 23,0) mg/l sulfates (0,20 – 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 90 | Water | Chemical oxygen demand - COD-Cr Range (7,0 – 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 91 | Water | Dissolved solids Range (30 – 500) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 92 | Wastewater | Ammonium nitrogen concentration Range (3,0 – 100) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 93 | Wastewater | Ammonium ion concentration Range (4,0 – 130) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 94 | Wastewater | Anion concentrations chlorides (0,20 – 1000) mg/l nitrates (0,20 – 100) mg/l nitrate nitrogen (0,050 – 23,0) mg/l sulfates (0,20 – 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 95 | Wastewater | Chemical oxygen demand – COD-Cr Range (10,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 96 | Water and wastewater | Total suspended solids (TSS) Range (2,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 97 | Water and wastewater | Substances extractable with petroleum ether Range (1,0 – 50) mg/l |
Gravimetric method | PB-10/KR wydanie 1 z dnia 02.03.2020 r. | |
| 98 | Water and wastewater | Orthophosphate concentration Range (0,015 – 60) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 | |
| 99 | Water and wastewater | Orthophosphate concentration (calculated as P) Range (0,0050 – 20) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 | |
| 100 | Water and wastewater | Total phosphorus concentration Range (0,020 – 20) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010 | |
| 101 | Water and wastewater | Nitrite nitrogen concentration Range (0,0020 – 10,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 102 | Water and wastewater | Nitrite concentration Range (0,0066 – 33,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 103 | Water and wastewater | Nitrate nitrogen concentration Range (0,10 – 40,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 104 | Water and wastewater | Nitrate concentration Range (0,44 – 180) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 105 | Water and wastewater | Kjeldahl nitrogen concentration Range (0,20 – 3,0) mg/l |
Spectrophotometric method | PN-EN 25663:2001 | |
| 106 | Water and wastewater | Kjeldahl nitrogen concentration Range (3,0 – 750) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 107 | Water and wastewater | Total nitrogen concentration (calculated) | PB-26/CLB wydanie 1 z dnia 16.01.2026 | ||
| 108 | Water and wastewater | Ammonium nitrogen concentration Range (0,040 – 3,0) mg/l |
Spectrophotometric method | PN ISO 7150-1:2002 | |
| 109 | Water and wastewater | Ammonium ion (ammonia) concentration Range (0,050 – 3,9) mg/l |
Spectrophotometric method | PN ISO 7150-1:2002 | |
| 110 | Water and wastewater | Biochemical oxygen demand - BOD5, BOD2+5 Range (0,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 111 | Water and wastewater | Biochemical oxygen demand - BOD5, BOD2+5 Range (1,0 – 1000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 112 | Soil, ground | pH - in H2O, pH - in KCl Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 113 | Sewage sludge Odpady O): kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
pH - in H2O Range (2,0 – 12,0) |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 114 | Sewage sludge Odpady O): kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Ammonium nitrogen content Range (0,15 – 5,0) % |
Titrimetric method | PN-75/C-04576.15 | |
| 115 | Sewage sludge Odpady O): kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Loss on ignition of dry matter (organic matter content) Range (1,0 – 95,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 116 | Sewage sludge Odpady O): kod 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Total phosphorus concentration Range (0,10 – 4,50)% |
Spectrophotometric method | PN-EN 14672:2006 | |
| 117 | Gleba, grunty, osady ściekowe, osad denny |
Dry matter and water content Range (0,10 – 99,9) % |
Gravimetric method | PN-ISO 11465:1999 | |
| 118 | Gleba, grunty, osady ściekowe, osad denny |
Total nitrogen content Range (50 – 80000) mg/kg |
Titrimetric method | PN-ISO 11261:2002 | |
| 119 | Soil, ground Odpady O): kod 17 05 03, 17 05 04, 19 08 02, 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Total dissolved solids content (TDS) Range (1000 – 250000) mg/kg |
Gravimetric method | PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
| 120 | Soil, ground Odpady O): kod 17 05 03, 17 05 04, 19 08 02, 19 08 05 O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów |
Anion content: chlorides (10 – 40000) mg/kg fluorides (0,5 – 20) mg/kg sulfates (10 – 80000) mg/kg |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 | |
Reference standards (66)
IB-KR-01 wydanie 1 z dnia 15.12.2025
ISO 17289:2014
PB-04/KR wydanie 1 z dnia 02.03.2020 r.
PB-09/CLB wydanie 1 z dnia 30.05.2022
PB-10/KR wydanie 1 z dnia 02.03.2020 r.
PB-11/CLB wydanie 1 z dnia 25.09.2023 r.
PB-26/CLB wydanie 1 z dnia 16.01.2026
PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
PN ISO 7150-1:2002
PN-71/C-04593
PN-75/C-04576.15
PN-77/C-04584
PN-77/C-04604.08
PN-82/C-04576.08
PN-EN 12457-2:2006
PN-EN 12457-4:2006
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 metoda A
PN-EN ISO 11732:2007
PN-EN ISO 11885:2009
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004
PN-EN ISO 14403-2:2012
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 22036:2024-07
PN-EN ISO 54321:2021-07 metoda B
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 11261:2002
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 4364:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3
PN-ISO 5667-4:2017-10
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H