🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 176 • Warszawa, Poland • 120 methods

Water & wastewaterEnvironmentElectronics & EMC

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 176 (Warszawa, Poland). Its accreditation scope covers 120 test methods in the following areas: Water & wastewater, Environment, Electronics & EMC. Test objects include: Water, wastewater, Water and wastewater, O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie ka…, Soil, ground. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 176
  • Methods in scope: 120
  • Types of test objects: 35
  • Techniques used: 20
  • City: Warszawa, Poland
Accreditation number
AB 176
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KRAKOWIE
City
Warszawa, Poland

What this laboratory tests (35)

Analytical techniques used (20)

Laboratory sections (4)

Laboratory locations

Accreditation scope — test methods (120)

No. Test object Methodology / Parameters Technique Reference document
Pracownia w Krakowie
1 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,50 - 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025
2 Water, wastewater Biochemical oxygen demand - BOD5
Range (3 – 1000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
3 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
4 Water, wastewater Nitrite nitrogen concentration
Range (0,0010 – 2,5) mg/l
Spectrophotometric method PN-EN 26777:1999
5 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 500) mg/l
Potentiometric titration method PN-EN 25663:2001
6 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
7 Water, wastewater Chemical oxygen demand – COD-Cr
Range (5,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
8 Water, wastewater Total phosphorus concentration
Range (0,015 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
9 Water Element concentrations:
silver (0,5 – 50) µg/l aluminium (1 – 1000) µg/l arsenic (0,5 – 50) µg/l boron (1 – 1000) µg/l barium (1 – 1000) µg/l beryllium (0,2 – 50) µg/l cadmium (0,02 – 10) µg/l cobalt (0,5 – 50) µg/l chromium (0,1 – 50) µg/l copper (0,5 – 50) µg/l iron (1 – 1000) µg/l manganese (1 – 1000) µg/l molybdenum (0,5 – 50) µg/l nickel (0,5 – 50) µg/l lead (0,2 – 50) µg/l antimony (0,5 – 50) µg/l selenium (1 – 50) µg/l tin (0,5 – 50) µg/l titanium (0,5 – 50) µg/l thallium (0,5 – 50) µg/l vanadium (0,5 – 50) µg/l zinc (1 – 1000) µg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2:2024-04
10 Water Mercury concentration
Range (0,010 – 0,10) µg/l
Atomic fluorescence spectrometry PN-EN ISO 17852:2009
11 Wastewater Nitrate nitrogen concentration
Range (0,10 – 150) mg/l
Spectrophotometric method PN-82/C-04576.08
12 Wastewater Chromium(VI) concentration
Range (0,010 – 10) mg/l
Spectrophotometric method PN-77/C-04604.08
13 Wastewater Mercury concentration
Range (0,010 – 0,50) µg/l
Atomic fluorescence spectrometry PN-EN ISO 17852:2009
Pracownia Terenowa
14 General environment
- hałas pochodzący od instalacji, urządzeń i zakładów
przemysłowych
A-weighted equivalent sound pressure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
15 General environment
- hałas pochodzący od instalacji, urządzeń i zakładów
przemysłowych
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
16 General environment
- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów
przemysłowych
A-weighted equivalent sound pressure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
17 General environment
- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów
przemysłowych
A-weighted sound exposure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
18 General environment
- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów
przemysłowych
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
19 General environment
- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych
A-weighted equivalent sound pressure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H
20 General environment
- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych
A-weighted sound exposure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H
21 General environment
- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H
22 General environment
- hałas pochodzący od lotnisk
A-weighted equivalent sound pressure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H
23 General environment
- hałas pochodzący od lotnisk
A-weighted sound exposure level
Range (22,0 – 130,0) dB
Direct measurement method Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H
24 General environment
- hałas pochodzący od lotnisk
A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H
25 Środowisko
– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych
Electric field strength at 50 Hz frequency
Range (1,0 – 30000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
26 Środowisko
– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych
Magnetic flux density at 50 Hz frequency
Range od 1 µT do 10 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
27 Środowisko
– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych
Magnetic field strength at 50 Hz frequency (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
28 Środowisko
– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe
Electric field strength: - w zakresie częstotliwości od 80 MHz do 60 GHz
Range (0,5 – 300) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
29 Środowisko
– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe
Electric field strength: - w zakresie częstotliwości od 420 MHz do 6 GHz
Range (0,05 – 200) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
30 Środowisko
– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe
Magnetic field strength: - w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
31 Środowisko
– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne
Electric field strength: - w zakresie częstotliwości od 420 MHz do 6 GHz
Range (0,05 – 200) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
32 Środowisko
– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne
Magnetic field strength: - w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
33 Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3
34 Water Temperature
Range (1,0 – 50,0) oC
PN-77/C-04584
35 Water Dissolved oxygen concentration
Range (0,5 – 16,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
36 Water Oxygen saturation
Range (5 – 180) %
Electrochemical method PN-EN ISO 5814:2013-04
37 Water Dissolved oxygen concentration
Range (0,5 – 16,0) mg/l O2
Optical method ISO 17289:2014
38 Water Oxygen saturation
Range (5 – 180) %
Optical method ISO 17289:2014
39 Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
40 Wastewater, rainwater, snowmelt water Temperature
Range (1,0 – 50,0) oC
PN-77/C-04584
41 Sewage sludge Sampling for chemical, physical and biological testing PN-EN ISO 5667-13:2011
42 Bottom sediment Sampling for chemical and physical testing PN-ISO 4364:2005
43 Soil, ground Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009
44 Water, wastewater pH
Range (2,0 – 12,0)
Potentiometric method PN-EN ISO 10523:2012
45 Water, wastewater Electrical conductivity
Range (84,0 – 12800) µS/cm
Conductometric method PN-EN 27888:1999
46 Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.
Pracownia w Tarnowie
47 Sewage sludge pH – in H2O
Range (4,0 – 12,0)
Potentiometric method PN-EN ISO 10390:2022-09
48 Soil, ground pH – in H2O, pH – in KCl
Range (4,0 – 12,0)
Potentiometric method PN-EN ISO 10390:2022-09
49 Water, wastewater Dissolved solids
Range (50 – 2000) mg/l
Gravimetric method PN-EN 15216:2022-03
50 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
51 Water, wastewater Biochemical oxygen demand - BOD5,
Range (1,0 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
52 Water, wastewater Ammonium nitrogen concentration
Range (0,04 – 250) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 11732:2007
53 Water, wastewater Ammonium ion (ammonia) concentration (calculated) PN-EN ISO 11732:2007
54 Water, wastewater Nitrite nitrogen concentration
Range (0,0020 – 2,5) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
55 Water, wastewater Nitrite concentration
Range (0,0070 – 8,2) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
56 Water, wastewater Nitrate nitrogen concentration
Range (0,20 – 250) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
57 Water, wastewater Nitrate concentration
Range (0,90 – 1100) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 13395:2001
58 Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
59 Water, wastewater Free cyanide concentration
Range (0,01 – 1,0) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14403-2:2012
60 Water, wastewater Total cyanide concentration
Range (0,01 – 1,0) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14403-2:2012
61 Water, wastewater Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012
62 Water, wastewater Total phosphorus concentration
Range (0,010 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010
63 Water, wastewater Phosphate concentration
Range (0,030 – 300) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 15681-2:2019-02
64 Water, wastewater Chemical oxygen demand – COD-Cr
Range (7,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
65 Water, wastewater Phenol index
Range (0,0010 – 5,0) mg/l
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14402:2004
66 Water, wastewater Formaldehyde concentration
Range (0,010 – 2,0) mg/l
Spectrophotometric method PN-71/C-04593
67 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
68 Water, wastewater Concentration: - ogólnego węgla organicznego - rozpuszczonego węgla organicznego
Range (1,0 –1000) mg/l
Infrared spectrometry method (IR) PN-EN 1484:1999
69 Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH)
Anthracene (0,005 – 0,10) µg/l fluoranthene (0,005 – 0,10) µg/l naphthalene (0,005 – 0,10) µg/l benzo(b)fluoranthene (0,005 – 0,10) µg/l benzo(k)fluoranthene (0,005 – 0,10) µg/l benzo(g, h, i)perylene (0,001 – 0,010) µg/l indeno(1, 2, 3-cd)piren (0,001 – 0,010) µg/l dibenzo(a,h)anthracene (0,001 – 0,010) µg/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
70 Water, wastewater Stężenie fosforu ogólnego:
Range (0,010 – 50) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
71 Water, wastewater,
wody opadowe, wody roztopowe
Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
72 Water, wastewater,
wody opadowe, wody roztopowe
Mineral oil index
Range (0,05 – 50,0) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
73 Water Concentration of polycyclic aromatic hydrocarbons (PAH)
benzo(a)pyrene (0,00011 – 0,10) µg/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
74 Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH)
benzo(a)pyrene (0,005 – 0,10) µg/l
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
75 Wastewater Element concentration
antimony (0,050 – 100) mg/l arsenic (0,010 – 100) mg/l barium (0,050 – 100) mg/l beryllium (0,050 – 100) mg/l boron (0,050 – 100) mg/l total chromium (0,050 – 100) mg/l tin (0,050 – 100) mg/l zinc (0,050 – 100) mg/l aluminium (0,050 – 100) mg/l cadmium (0,010 – 100) mg/l cobalt (0,010 – 100) mg/l manganese (0,050 – 100) mg/l copper (0,010 – 100) mg/l molybdenum (0,050 – 100) mg/l nickel (0,010 – 100) mg/l lead (0,010 – 100) mg/l potassium (1,0 – 1000) mg/l selenium (0,050 – 100) mg/l sodium (1,0 – 1000) mg/l silver (0,025 – 100) mg/l thallium (0,050 – 100) mg/l titanium (0,050 – 100) mg/l vanadium (0,050 – 100) mg/l iron (0,050 – 100) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
76 Sewage sludge Dry residue (dry matter)
Range (5,0 – 99,9) %
Gravimetric method PN-EN ISO 11465:2026-03 metoda A
77 Sewage sludge Loss on ignition of dry matter (organic matter content)
Range (2,0 – 95,0) %
Gravimetric method PN-EN 15935:2022-01
78 Soil, ground Dry matter
Range (30,0 – 99,9) %
Gravimetric method PN-EN ISO 11465:2026-03 metoda A
79 Soil, ground Water content (calculated) PN-EN ISO 11465:2026-03 metoda A
80 Soil, ground Element content
arsenic (0,50 – 1000) mg/kg barium (2,50 – 1000) mg/kg total chromium (2,50 – 1000) mg/kg tin (0,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg cobalt (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg molybdenum (0,50 – 1000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B
81 Sewage sludge Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp.
Range od 1 szt./50 g
Flotation method, microscopic PB-09/CLB wydanie 1 z dnia 30.05.2022
82 Soil, ground
Odpady O): kod 17 05 04
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Total dissolved solids content (TDS)
Range (500 – 20000) mg/kg
Gravimetric method PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006
83 Soil, ground
Odpady O): kod 17 05 04
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Dissolved organic carbon (DOC) content
Range (10 – 10000) mg/kg
Infrared spectrometry method (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006
84 Soil, ground
Odpady O): kod 17 05 04
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Phenol index
Range (0,01 – 50) mg/kg
Continuous flow analysis (CFA) with spectrophotometric detection PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006
85 Odpady O): kod 17 05 04
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Element content
arsenic (0,50 – 1000) mg/kg barium (2,50 – 1000) mg/kg total chromium (2,50 – 1000) mg/kg tin (0,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg cobalt (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg molybdenum (0,50 – 1000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B
86 Sewage sludge
Waste O): code 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Element content
chromium (2,50 – 1000) mg/kg zinc (2,50 – 4000) mg/kg cadmium (0,50 – 1000) mg/kg copper (2,50 – 2000) mg/kg nickel (2,50 – 1000) mg/kg lead (2,50 – 1000) mg/kg total phosphorus (0,025 – 4,0) % magnesium (0,010 – 1,0) % calcium (0,025 – 10,0) %
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B
87 Soil, ground
Odpady O): kod 17 05 04*)
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.
Mercury content
Range (0,001 – 5,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006
88 Soil, ground, sewage sludge*)
*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.
Mercury content
Range (0,010 – 5,0) mg/kg
Atomic absorption spectrometry with amalgamation technique PB-04/KR wydanie 1 z dnia 02.03.2020 r.
Pracownia w Nowym Sączu
89 Water Anion concentrations:
fluorides (0,050 – 0,60) mg/l chlorides (0,20 – 3000) mg/l nitrates (0,20 – 100) mg/l nitrate nitrogen (0,050 – 23,0) mg/l sulfates (0,20 – 1000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
90 Water Chemical oxygen demand - COD-Cr
Range (7,0 – 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
91 Water Dissolved solids
Range (30 – 500) mg/l
Gravimetric method PN-EN 15216:2022-03
92 Wastewater Ammonium nitrogen concentration
Range (3,0 – 100) mg/l
Titrimetric method PN-ISO 5664:2002
93 Wastewater Ammonium ion concentration
Range (4,0 – 130) mg/l
Titrimetric method PN-ISO 5664:2002
94 Wastewater Anion concentrations
chlorides (0,20 – 1000) mg/l nitrates (0,20 – 100) mg/l nitrate nitrogen (0,050 – 23,0) mg/l sulfates (0,20 – 1000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
95 Wastewater Chemical oxygen demand – COD-Cr
Range (10,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
96 Water and wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
97 Water and wastewater Substances extractable with petroleum ether
Range (1,0 – 50) mg/l
Gravimetric method PB-10/KR wydanie 1 z dnia 02.03.2020 r.
98 Water and wastewater Orthophosphate concentration
Range (0,015 – 60) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
99 Water and wastewater Orthophosphate concentration (calculated as P)
Range (0,0050 – 20) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
100 Water and wastewater Total phosphorus concentration
Range (0,020 – 20) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
101 Water and wastewater Nitrite nitrogen concentration
Range (0,0020 – 10,0) mg/l
Spectrophotometric method PN-EN 26777:1999
102 Water and wastewater Nitrite concentration
Range (0,0066 – 33,0) mg/l
Spectrophotometric method PN-EN 26777:1999
103 Water and wastewater Nitrate nitrogen concentration
Range (0,10 – 40,0) mg/l
Spectrophotometric method PN-82/C-04576.08
104 Water and wastewater Nitrate concentration
Range (0,44 – 180) mg/l
Spectrophotometric method PN-82/C-04576.08
105 Water and wastewater Kjeldahl nitrogen concentration
Range (0,20 – 3,0) mg/l
Spectrophotometric method PN-EN 25663:2001
106 Water and wastewater Kjeldahl nitrogen concentration
Range (3,0 – 750) mg/l
Titrimetric method PN-EN 25663:2001
107 Water and wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026
108 Water and wastewater Ammonium nitrogen concentration
Range (0,040 – 3,0) mg/l
Spectrophotometric method PN ISO 7150-1:2002
109 Water and wastewater Ammonium ion (ammonia) concentration
Range (0,050 – 3,9) mg/l
Spectrophotometric method PN ISO 7150-1:2002
110 Water and wastewater Biochemical oxygen demand - BOD5, BOD2+5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
111 Water and wastewater Biochemical oxygen demand - BOD5, BOD2+5
Range (1,0 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
112 Soil, ground pH - in H2O, pH - in KCl
Range (2,0 – 12,0)
Potentiometric method PN-EN ISO 10390:2022-09
113 Sewage sludge
Odpady O):
kod 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
pH - in H2O
Range (2,0 – 12,0)
Potentiometric method PN-EN ISO 10390:2022-09
114 Sewage sludge
Odpady O):
kod 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Ammonium nitrogen content
Range (0,15 – 5,0) %
Titrimetric method PN-75/C-04576.15
115 Sewage sludge
Odpady O):
kod 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Loss on ignition of dry matter (organic matter content)
Range (1,0 – 95,0) %
Gravimetric method PN-EN 15935:2022-01
116 Sewage sludge
Odpady O):
kod 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Total phosphorus concentration
Range (0,10 – 4,50)%
Spectrophotometric method PN-EN 14672:2006
117 Gleba, grunty,
osady ściekowe,
osad denny
Dry matter and water content
Range (0,10 – 99,9) %
Gravimetric method PN-ISO 11465:1999
118 Gleba, grunty,
osady ściekowe,
osad denny
Total nitrogen content
Range (50 – 80000) mg/kg
Titrimetric method PN-ISO 11261:2002
119 Soil, ground
Odpady O): kod
17 05 03, 17 05 04,
19 08 02, 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Total dissolved solids content (TDS)
Range (1000 – 250000) mg/kg
Gravimetric method PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006
120 Soil, ground
Odpady O): kod
17 05 03, 17 05 04,
19 08 02, 19 08 05
O) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
Anion content:
chlorides (10 – 40000) mg/kg fluorides (0,5 – 20) mg/kg sulfates (10 – 80000) mg/kg
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006

Reference standards (66)

IB-KR-01 wydanie 1 z dnia 15.12.2025
ISO 17289:2014
PB-04/KR wydanie 1 z dnia 02.03.2020 r.
PB-09/CLB wydanie 1 z dnia 30.05.2022
PB-10/KR wydanie 1 z dnia 02.03.2020 r.
PB-11/CLB wydanie 1 z dnia 25.09.2023 r.
PB-26/CLB wydanie 1 z dnia 16.01.2026
PB-26/CLB wydanie 1 z dnia 16.01.2026 r.
PN ISO 7150-1:2002
PN-71/C-04593
PN-75/C-04576.15
PN-77/C-04584
PN-77/C-04604.08
PN-82/C-04576.08
PN-EN 12457-2:2006
PN-EN 12457-4:2006
PN-EN 14672:2006
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11465:2026-03 metoda A
PN-EN ISO 11732:2007
PN-EN ISO 11885:2009
PN-EN ISO 13395:2001
PN-EN ISO 14402:2004
PN-EN ISO 14403-2:2012
PN-EN ISO 15681-2:2019-02
PN-EN ISO 17294-2:2024-04
PN-EN ISO 17852:2009
PN-EN ISO 17993:2005
PN-EN ISO 22036:2024-07
PN-EN ISO 54321:2021-07 metoda B
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 10381-4:2007
PN-ISO 10381-5:2009
PN-ISO 11261:2002
PN-ISO 11465:1999
PN-ISO 15705:2005
PN-ISO 4364:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3
PN-ISO 5667-4:2017-10
Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F
Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H
Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H