{"lab":{"_id":"69ad52a3de79e566650fb157","accr_number":"AB 176","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KRAKOWIE","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":120,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_176.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w krakowie water other materials environment metrology pharma electronics petro food","status":"active","updated_at":"2026-03-08T14:50:52.985Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T15:05:57.431Z","location":{"type":"Point","coordinates":[21.0122,52.2297]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20176,podmiot.html","fields_of_testing":[{"codes":"B/32/P","pl":"Badania biologiczne i pobieranie próbek osadów","en":"Biological tests and sampling of sediments"},{"codes":"C/28/P, C/30/P, C/31/P, C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, osadów, gleby","en":"Chemical tests and sampling of water, sewage, sediments, soil"},{"codes":"C/32","pl":"Badania chemiczne odpadów","en":"Chemical tests of waste"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors - noise, electromagnetic field)"},{"codes":"N/28/P, N/30/P, N/31/P, N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, osadów, gleby","en":"Tests of physical properties and sampling of water, sewage, sediments, soil"},{"codes":"N/32","pl":"Badania właściwości fizycznych odpadów","en":"Tests of physical properties of waste"}],"issue":{"no":"39","date":"08.05.2026"},"parse_date":"2026-08-17T15:05:57.431Z","parse_source":"agent-claude-code","map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"CENTRALNE LABORATORIUM BADAWCZE ODDZIAŁ W KRAKOWIE","address":"ul. Półłanki 76E","city":"Kraków","postal":"30-740"},{"name":"Pracownia w Krakowie","address":"ul. Półłanki 76E, 30-740 Kraków","city":"Kraków","postal":"30-740"},{"name":"Pracownia Terenowa","address":"ul. Półłanki 76E, 30-740 Kraków","city":"Kraków","postal":"30-740"},{"name":"Pracownia w Tarnowie","address":"ul. Krasińskiego 7a, 33-100 Tarnów","city":"Tarnów","postal":"33-100"},{"name":"Pracownia w Nowym Sączu","address":"ul. Fabryczna 11, 33-300 Nowy Sącz","city":"Nowy Sącz","postal":"33-300"}],"scope_format":"PCA::pracownie+siatka7","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/2a5efef60230169ee923647ece554464/AB%20176.pdf","has_en":true,"category_counts":{"water":88,"environment":41,"materials":5,"petro":1},"category_scores":{"water":57.36,"environment":12.45,"materials":0.19,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a832355884ede9a1b2c4e7b","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,50 - 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025","norm_bases":["PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2","IB-KR-01 wydanie 1 z dnia 15.12.2025"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 - 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyl. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,50 - 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025","technique_en":"Optical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 - 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN 1899-2:2002 z wył. p. 7.2.1, 7.2.2 | IB-KR-01 wydanie 1 z dnia 15.12.2025","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a832355884ede9a1b2c4e7c","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3 – 1000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 1000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3 – 1000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(3 – 1000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a832355884ede9a1b2c4e7d","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4e7e","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0010 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0010 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0010 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0010 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0010 – 2,5) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0010 – 2,5) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4e7f","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 500) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 500) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 500) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Potentiometric titration method Range PN-EN 25663:2001","technique_en":"Potentiometric titration method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 500) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 电位滴定法 范围 PN-EN 25663:2001","technique_zh":"电位滴定法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4e80","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026 r."],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4e81","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832355884ede9a1b2c4e82","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,015 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,015 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,015 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,015 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,015 – 50) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4e83","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków:","parameters":[{"name":"srebro","range":"(0,5 – 50) µg/l"},{"name":"glin","range":"(1 – 1000) µg/l"},{"name":"arsen","range":"(0,5 – 50) µg/l"},{"name":"bor","range":"(1 – 1000) µg/l"},{"name":"bar","range":"(1 – 1000) µg/l"},{"name":"beryl","range":"(0,2 – 50) µg/l"},{"name":"kadm","range":"(0,02 – 10) µg/l"},{"name":"kobalt","range":"(0,5 – 50) µg/l"},{"name":"chrom","range":"(0,1 – 50) µg/l"},{"name":"miedź","range":"(0,5 – 50) µg/l"},{"name":"żelazo","range":"(1 – 1000) µg/l"},{"name":"mangan","range":"(1 – 1000) µg/l"},{"name":"molibden","range":"(0,5 – 50) µg/l"},{"name":"nikiel","range":"(0,5 – 50) µg/l"},{"name":"ołów","range":"(0,2 – 50) µg/l"},{"name":"antymon","range":"(0,5 – 50) µg/l"},{"name":"selen","range":"(1 – 50) µg/l"},{"name":"cyna","range":"(0,5 – 50) µg/l"},{"name":"tytan","range":"(0,5 – 50) µg/l"},{"name":"tal","range":"(0,5 – 50) µg/l"},{"name":"wanad","range":"(0,5 – 50) µg/l"},{"name":"cynk","range":"(1 – 1000) µg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków:\nZakres:\nsrebro (0,5 – 50) µg/l\nglin (1 – 1000) µg/l\narsen (0,5 – 50) µg/l\nbor (1 – 1000) µg/l\nbar (1 – 1000) µg/l\nberyl (0,2 – 50) µg/l\nkadm (0,02 – 10) µg/l\nkobalt (0,5 – 50) µg/l\nchrom (0,1 – 50) µg/l\nmiedź (0,5 – 50) µg/l\nżelazo (1 – 1000) µg/l\nmangan (1 – 1000) µg/l\nmolibden (0,5 – 50) µg/l\nnikiel (0,5 – 50) µg/l\nołów (0,2 – 50) µg/l\nantymon (0,5 – 50) µg/l\nselen (1 – 50) µg/l\ncyna (0,5 – 50) µg/l\ntytan (0,5 – 50) µg/l\ntal (0,5 – 50) µg/l\nwanad (0,5 – 50) µg/l\ncynk (1 – 1000) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków:\nZakres:\nsrebro (0,5 – 50) µg/l\nglin (1 – 1000) µg/l\narsen (0,5 – 50) µg/l\nbor (1 – 1000) µg/l\nbar (1 – 1000) µg/l\nberyl (0,2 – 50) µg/l\nkadm (0,02 – 10) µg/l\nkobalt (0,5 – 50) µg/l\nchrom (0,1 – 50) µg/l\nmiedź (0,5 – 50) µg/l\nżelazo (1 – 1000) µg/l\nmangan (1 – 1000) µg/l\nmolibden (0,5 – 50) µg/l\nnikiel (0,5 – 50) µg/l\nołów (0,2 – 50) µg/l\nantymon (0,5 – 50) µg/l\nselen (1 – 50) µg/l\ncyna (0,5 – 50) µg/l\ntytan (0,5 – 50) µg/l\ntal (0,5 – 50) µg/l\nwanad (0,5 – 50) µg/l\ncynk (1 – 1000) µg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PN-EN ISO 17294-2:2024-04 Woda Stezenie pierwiastkow:\nZakres:\nsrebro (0,5 – 50) µg/l\nglin (1 – 1000) µg/l\narsen (0,5 – 50) µg/l\nbor (1 – 1000) µg/l\nbar (1 – 1000) µg/l\nberyl (0,2 – 50) µg/l\nkadm (0,02 – 10) µg/l\nkobalt (0,5 – 50) µg/l\nchrom (0,1 – 50) µg/l\nmiedz (0,5 – 50) µg/l\nzelazo (1 – 1000) µg/l\nmangan (1 – 1000) µg/l\nmolibden (0,5 – 50) µg/l\nnikiel (0,5 – 50) µg/l\nolow (0,2 – 50) µg/l\nantymon (0,5 – 50) µg/l\nselen (1 – 50) µg/l\ncyna (0,5 – 50) µg/l\ntytan (0,5 – 50) µg/l\ntal (0,5 – 50) µg/l\nwanad (0,5 – 50) µg/l\ncynk (1 – 1000) µg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentrations:","parameters_en":[{"name":"silver","range":"(0,5 – 50) µg/l"},{"name":"aluminium","range":"(1 – 1000) µg/l"},{"name":"arsenic","range":"(0,5 – 50) µg/l"},{"name":"boron","range":"(1 – 1000) µg/l"},{"name":"barium","range":"(1 – 1000) µg/l"},{"name":"beryllium","range":"(0,2 – 50) µg/l"},{"name":"cadmium","range":"(0,02 – 10) µg/l"},{"name":"cobalt","range":"(0,5 – 50) µg/l"},{"name":"chromium","range":"(0,1 – 50) µg/l"},{"name":"copper","range":"(0,5 – 50) µg/l"},{"name":"iron","range":"(1 – 1000) µg/l"},{"name":"manganese","range":"(1 – 1000) µg/l"},{"name":"molybdenum","range":"(0,5 – 50) µg/l"},{"name":"nickel","range":"(0,5 – 50) µg/l"},{"name":"lead","range":"(0,2 – 50) µg/l"},{"name":"antimony","range":"(0,5 – 50) µg/l"},{"name":"selenium","range":"(1 – 50) µg/l"},{"name":"tin","range":"(0,5 – 50) µg/l"},{"name":"titanium","range":"(0,5 – 50) µg/l"},{"name":"thallium","range":"(0,5 – 50) µg/l"},{"name":"vanadium","range":"(0,5 – 50) µg/l"},{"name":"zinc","range":"(1 – 1000) µg/l"}],"search_en":"Water Element concentrations: Inductively coupled plasma mass spectrometry (ICP-MS) silver aluminium arsenic boron barium beryllium cadmium cobalt chromium copper iron manganese molybdenum nickel lead antimony selenium tin titanium thallium vanadium zinc PN-EN ISO 17294-2:2024-04","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Water","methodology_zh":"元素浓度：","parameters_zh":[{"name":"银","range":"(0,5 – 50) µg/l"},{"name":"铝","range":"(1 – 1000) µg/l"},{"name":"砷","range":"(0,5 – 50) µg/l"},{"name":"硼","range":"(1 – 1000) µg/l"},{"name":"钡","range":"(1 – 1000) µg/l"},{"name":"铍","range":"(0,2 – 50) µg/l"},{"name":"镉","range":"(0,02 – 10) µg/l"},{"name":"钴","range":"(0,5 – 50) µg/l"},{"name":"铬","range":"(0,1 – 50) µg/l"},{"name":"铜","range":"(0,5 – 50) µg/l"},{"name":"铁","range":"(1 – 1000) µg/l"},{"name":"锰","range":"(1 – 1000) µg/l"},{"name":"钼","range":"(0,5 – 50) µg/l"},{"name":"镍","range":"(0,5 – 50) µg/l"},{"name":"铅","range":"(0,2 – 50) µg/l"},{"name":"锑","range":"(0,5 – 50) µg/l"},{"name":"硒","range":"(1 – 50) µg/l"},{"name":"锡","range":"(0,5 – 50) µg/l"},{"name":"钛","range":"(0,5 – 50) µg/l"},{"name":"铊","range":"(0,5 – 50) µg/l"},{"name":"钒","range":"(0,5 – 50) µg/l"},{"name":"锌","range":"(1 – 1000) µg/l"}],"search_zh":"水 元素浓度： 电感耦合等离子体质谱法（ICP-MS） 银 铝 砷 硼 钡 铍 镉 钴 铬 铜 铁 锰 钼 镍 铅 锑 硒 锡 钛 铊 钒 锌 PN-EN ISO 17294-2:2024-04","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","test_object_zh":"水"},{"_id":"6a832355884ede9a1b2c4e84","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 0,10) µg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej","techniques":["Metoda atomowej spektrometrii fluorescencyjnej"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,010 – 0,10) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie rtęci\nZakres (0,010 – 0,10) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009 Woda Stezenie rteci\nZakres (0,010 – 0,10) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,10) µg/l"}],"search_en":"Water Mercury concentration Atomic fluorescence spectrometry Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry","test_object_en":"Water","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,10) µg/l"}],"search_zh":"水 汞浓度 原子荧光光谱法 范围 PN-EN ISO 17852:2009","test_object_zh":"水","technique_zh":"原子荧光光谱法"},{"_id":"6a832355884ede9a1b2c4e85","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,10 – 150) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 150) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 150) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a832355884ede9a1b2c4e86","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604.08","norm_bases":["PN-77/C-04604.08"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-77/C-04604.08","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604.08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a832355884ede9a1b2c4e87","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 0,50) µg/l"}],"technique":"Metoda atomowej spektrometrii fluorescencyjnej","techniques":["Metoda atomowej spektrometrii fluorescencyjnej"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,010 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":"Pracownia w Krakowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,010 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009 Scieki Stezenie rteci\nZakres (0,010 – 0,50) µg/l\nMetoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,50) µg/l"}],"search_en":"Wastewater Mercury concentration Atomic fluorescence spectrometry Range PN-EN ISO 17852:2009","technique_en":"Atomic fluorescence spectrometry","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,50) µg/l"}],"search_zh":"污水 汞浓度 原子荧光光谱法 范围 PN-EN ISO 17852:2009","test_object_zh":"污水","technique_zh":"原子荧光光谱法"},{"_id":"6a832355884ede9a1b2c4e88","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne\n- halas pochodzacy od instalacji, urzadzen i zakladow\nprzemyslowych Rownowazny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas pochodzący od instalacji, urządzeń i zakładów\n工业的 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas pochodzący od instalacji, urządzeń i zakładów\n工业的"},{"_id":"6a832355884ede9a1b2c4e89","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F Srodowisko ogolne\n- halas pochodzacy od instalacji, urzadzen i zakladow\nprzemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment\n- hałas pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境\n- hałas pochodzący od instalacji, urządzeń i zakładów\n工业的 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境\n- hałas pochodzący od instalacji, urządzeń i zakładów\n工业的"},{"_id":"6a832355884ede9a1b2c4e8a","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne\n- halas impulsowy pochodzacy od instalacji, urzadzen i zakladow\nprzemyslowych Rownowazny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的 A 计权等效声级 直接测量法 范围 Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的"},{"_id":"6a832355884ede9a1b2c4e8b","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology":"Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne\n- halas impulsowy pochodzacy od instalacji, urzadzen i zakladow\nprzemyslowych Ekspozycyjny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych A-weighted sound exposure level Direct measurement method Range Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的 A 计权声暴露级 直接测量法 范围 Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的","methodology_zh":"A 计权声暴露级"},{"_id":"6a832355884ede9a1b2c4e8c","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","norm_bases":["Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) Srodowisko ogolne\n- halas impulsowy pochodzacy od instalacji, urzadzen i zakladow\nprzemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 8 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_en":"General environment\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\nprzemysłowych","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 8 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706)","test_object_zh":"一般环境\n- hałas impulsowy pochodzący od instalacji, urządzeń i zakładów\n工业的"},{"_id":"6a832355884ede9a1b2c4e8d","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych A 计权等效声级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych"},{"_id":"6a832355884ede9a1b2c4e8e","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od drog, linii kolejowych, linii tramwajowych Ekspozycyjny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych A-weighted sound exposure level Direct measurement method Range Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych A 计权声暴露级 直接测量法 范围 Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology_zh":"A 计权声暴露级"},{"_id":"6a832355884ede9a1b2c4e8f","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","norm_bases":["Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od drog, linii kolejowych, linii tramwajowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 3 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wylaczeniem punktu H","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","test_object_en":"General environment\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 3 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824 i Nr 288 poz. 1697) z wyłączeniem punktu H","test_object_zh":"一般环境\n- hałas pochodzący od dróg, linii kolejowych, linii tramwajowych"},{"_id":"6a832355884ede9a1b2c4e90","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od lotnisk Równoważny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od lotnisk Rownowazny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas pochodzący od lotnisk A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas pochodzący od lotnisk","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas pochodzący od lotnisk A 计权等效声级 直接测量法 范围 Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas pochodzący od lotnisk"},{"_id":"6a832355884ede9a1b2c4e91","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od lotnisk","methodology":"Ekspozycyjny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22,0 – 130,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od lotnisk Ekspozycyjny poziom dźwięku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od lotnisk Ekspozycyjny poziom dzwieku A\nZakres (22,0 – 130,0) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted sound exposure level","parameters_en":[{"name":"Range","range":"(22,0 – 130,0) dB"}],"search_en":"General environment\n- hałas pochodzący od lotnisk A-weighted sound exposure level Direct measurement method Range Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","technique_en":"Direct measurement method","test_object_en":"General environment\n- hałas pochodzący od lotnisk","parameters_zh":[{"name":"范围","range":"(22,0 – 130,0) dB"}],"search_zh":"一般环境\n- hałas pochodzący od lotnisk A 计权声暴露级 直接测量法 范围 Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","technique_zh":"直接测量法","test_object_zh":"一般环境\n- hałas pochodzący od lotnisk","methodology_zh":"A 计权声暴露级"},{"_id":"6a832355884ede9a1b2c4e92","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko ogólne\n- hałas pochodzący od lotnisk","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne\n- hałas pochodzący od lotnisk Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H Srodowisko ogolne\n- halas pochodzacy od lotnisk Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 2 do Rozporzadzenia Ministra Srodowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wylaczeniem punktu H","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment\n- hałas pochodzący od lotnisk A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","test_object_en":"General environment\n- hałas pochodzący od lotnisk","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境\n- hałas pochodzący od lotnisk 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 2 do Rozporządzenia Ministra Środowiska z dnia 16.06.2011 r. (Dz.U. Nr 140 poz. 824) z wyłączeniem punktu H","test_object_zh":"一般环境\n- hałas pochodzący od lotnisk"},{"_id":"6a832355884ede9a1b2c4e93","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego o częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"(1,0 – 30000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego o częstotliwości 50 Hz\nZakres (1,0 – 30000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego o częstotliwości 50 Hz\nZakres (1,0 – 30000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego o czestotliwosci 50 Hz\nZakres (1,0 – 30000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength at 50 Hz frequency","parameters_en":[{"name":"Range","range":"(1,0 – 30000) V/m"}],"search_en":"Electric field strength at 50 Hz frequency Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","parameters_zh":[{"name":"范围","range":"(1,0 – 30000) V/m"}],"search_zh":"50 Hz 工频电场强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","methodology_zh":"50 Hz 工频电场强度"},{"_id":"6a832355884ede9a1b2c4e94","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna o częstotliwości 50 Hz","parameters":[{"name":"Zakres","range":"od 1 µT do 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna o częstotliwości 50 Hz\nZakres od 1 µT do 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o częstotliwości 50 Hz\nZakres od 1 µT do 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna o czestotliwosci 50 Hz\nZakres od 1 µT do 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density at 50 Hz frequency","parameters_en":[{"name":"Range","range":"od 1 µT do 10 mT"}],"search_en":"Magnetic flux density at 50 Hz frequency Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","parameters_zh":[{"name":"范围","range":"od 1 µT do 10 mT"}],"search_zh":"50 Hz 工频磁感应强度 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","methodology_zh":"50 Hz 工频磁感应强度"},{"_id":"6a832355884ede9a1b2c4e95","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego o częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego o czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength at 50 Hz frequency (calculated)","search_en":"Magnetic field strength at 50 Hz frequency (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"50 Hz 工频磁场强度（由计算得出）","search_zh":"50 Hz 工频磁场强度（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"},{"_id":"6a832355884ede9a1b2c4e96","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz","parameters":[{"name":"Zakres","range":"(0,5 – 300) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego:\n- w zakresie czestotliwosci od 80 MHz do 60 GHz\nZakres (0,5 – 300) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:\n- w zakresie częstotliwości od 80 MHz do 60 GHz","parameters_en":[{"name":"Range","range":"(0,5 – 300) V/m"}],"search_en":"Electric field strength:\n- w zakresie częstotliwości od 80 MHz do 60 GHz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","methodology_zh":"电场强度：\n- w zakresie częstotliwości od 80 MHz do 60 GHz","parameters_zh":[{"name":"范围","range":"(0,5 – 300) V/m"}],"search_zh":"电场强度：\n- w zakresie częstotliwości od 80 MHz do 60 GHz 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a832355884ede9a1b2c4e97","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters":[{"name":"Zakres","range":"(0,05 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego:\n- w zakresie czestotliwosci od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters_en":[{"name":"Range","range":"(0,05 – 200) V/m"}],"search_en":"Electric field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","methodology_zh":"电场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters_zh":[{"name":"范围","range":"(0,05 – 200) V/m"}],"search_zh":"电场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a832355884ede9a1b2c4e98","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń)","reference":"Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola magnetycznego:\n- w zakresie czestotliwosci od 80 MHz do 60 GHz (z obliczen) Punkt 3 Zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń)","search_en":"Magnetic field strength:\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"磁场强度：\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń)","search_zh":"磁场强度：\n- w zakresie częstotliwości od 80 MHz do 60 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"},{"_id":"6a832355884ede9a1b2c4e99","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne","methodology":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters":[{"name":"Zakres","range":"(0,05 – 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natężenie pola elektrycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natezenie pola elektrycznego:\n- w zakresie czestotliwosci od 420 MHz do 6 GHz\nZakres (0,05 – 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters_en":[{"name":"Range","range":"(0,05 – 200) V/m"}],"search_en":"Electric field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","methodology_zh":"电场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz","parameters_zh":[{"name":"范围","range":"(0,05 – 200) V/m"}],"search_zh":"电场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法"},{"_id":"6a832355884ede9a1b2c4e9a","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne","methodology":"Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń)","reference":"Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego prawnie\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natężenie pola magnetycznego:\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko\n– pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary selektywne Natezenie pola magnetycznego:\n- w zakresie czestotliwosci od 420 MHz do 6 GHz (z obliczen) Punkt 3 Zalacznika do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń)","search_en":"Magnetic field strength:\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","methodology_zh":"磁场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń)","search_zh":"磁场强度：\n- w zakresie częstotliwości od 420 MHz do 6 GHz (z obliczeń) Punkt 3 Załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"},{"_id":"6a832355884ede9a1b2c4e9b","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3","norm_bases":["PN-ISO 5667-4:2017-10","PN-EN ISO 5667-6:2016-12","PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2; 6.1.2; 6.2; 6.3","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 | PN-EN ISO 5667-6:2016-12 | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2; 6.1.2; 6.2; 6.3","test_object_zh":"水"},{"_id":"6a832355884ede9a1b2c4e9c","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) oC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (1,0 – 50,0) oC PN-77/C-04584 Woda Temperatura\nZakres (1,0 – 50,0) oC PN-77/C-04584","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) oC"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) oC"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a832355884ede9a1b2c4e9d","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 16,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 16,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 16,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a832355884ede9a1b2c4e9e","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Nasycenie tlenem","parameters":[{"name":"Zakres","range":"(5 – 180) %"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Nasycenie tlenem\nZakres (5 – 180) %\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Nasycenie tlenem\nZakres (5 – 180) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Nasycenie tlenem\nZakres (5 – 180) %\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen saturation","parameters_en":[{"name":"Range","range":"(5 – 180) %"}],"search_en":"Water Oxygen saturation Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5 – 180) %"}],"search_zh":"水 氧饱和度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水","methodology_zh":"氧饱和度"},{"_id":"6a832355884ede9a1b2c4e9f","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 16,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 – 16,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 16,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 – 16,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a832355884ede9a1b2c4ea0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Nasycenie tlenem","parameters":[{"name":"Zakres","range":"(5 – 180) %"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Nasycenie tlenem\nZakres (5 – 180) %\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Nasycenie tlenem\nZakres (5 – 180) %\nMetoda optyczna ISO 17289:2014 Woda Nasycenie tlenem\nZakres (5 – 180) %\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxygen saturation","parameters_en":[{"name":"Range","range":"(5 – 180) %"}],"search_en":"Water Oxygen saturation Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5 – 180) %"}],"search_zh":"水 氧饱和度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"氧饱和度"},{"_id":"6a832355884ede9a1b2c4ea1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki, wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater, rainwater, snowmelt water Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater, rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水、雨水、融雪水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水、雨水、融雪水"},{"_id":"6a832355884ede9a1b2c4ea2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) oC"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50,0) oC","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe, wody roztopowe Temperatura\nZakres (1,0 – 50,0) oC PN-77/C-04584 Scieki, wody opadowe, wody roztopowe Temperatura\nZakres (1,0 – 50,0) oC PN-77/C-04584","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50,0) oC"}],"search_en":"Wastewater, rainwater, snowmelt water Temperature Range PN-77/C-04584","test_object_en":"Wastewater, rainwater, snowmelt water","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) oC"}],"search_zh":"污水、雨水、融雪水 温度 范围 PN-77/C-04584","test_object_zh":"污水、雨水、融雪水","methodology_zh":"温度"},{"_id":"6a832355884ede9a1b2c4ea3","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and biological testing","search_en":"Sewage sludge Sampling for chemical, physical and biological testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 用于化学、物理与生物检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理与生物检验的采样"},{"_id":"6a832355884ede9a1b2c4ea4","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osad denny","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 4364:2005","norm_bases":["PN-ISO 4364:2005"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osad denny Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 4364:2005 Osad denny Pobieranie probek do badan chemicznych i fizycznych PN-ISO 4364:2005","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Bottom sediment Sampling for chemical and physical testing PN-ISO 4364:2005","test_object_en":"Bottom sediment","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-ISO 4364:2005"},{"_id":"6a832355884ede9a1b2c4ea5","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-4:2007","PN-ISO 10381-5:2009"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009 Gleba, grunty Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil, ground Sampling for chemical and physical testing PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_en":"Soil, ground","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤、土体 化学与物理检测用样品采集 PN-ISO 10381-4:2007 | PN-ISO 10381-5:2009","test_object_zh":"土壤、土体"},{"_id":"6a832355884ede9a1b2c4ea6","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4ea7","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84,0 – 12800) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84,0 – 12800) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (84,0 – 12800) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (84,0 – 12800) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(84,0 – 12800) µS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84,0 – 12800) µS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4ea8","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Odpady","methodology":"Badania interwencyjne (wg Programu DAB-11)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Badania interwencyjne (wg Programu DAB-11)","reference":"PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","norm_bases":["PB-11/CLB wydanie 1 z dnia 25.09.2023 r."],"lab_section":"Pracownia Terenowa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r. Odpady Badania interwencyjne (wg Programu DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intervention testing (according to Programme DAB-11)","search_en":"Waste Intervention testing (according to Programme DAB-11) PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","test_object_en":"Waste","search_zh":"废物 干预性检验（依据 DAB-11 计划） PB-11/CLB wydanie 1 z dnia 25.09.2023 r.","test_object_zh":"废物","methodology_zh":"干预性检验（依据 DAB-11 计划）"},{"_id":"6a832355884ede9a1b2c4ea9","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"(4,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres (4,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"(4,0 – 12,0)"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(4,0 – 12,0)"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a832355884ede9a1b2c4eaa","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH – w H2O, pH – w KCl","parameters":[{"name":"Zakres","range":"(4,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O, pH – w KCl\nZakres (4,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH – w H2O, pH – w KCl\nZakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba, grunty pH – w H2O, pH – w KCl\nZakres (4,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH – in H2O, pH – in KCl","parameters_en":[{"name":"Range","range":"(4,0 – 12,0)"}],"search_en":"Soil, ground pH – in H2O, pH – in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(4,0 – 12,0)"}],"search_zh":"土壤、土体 pH － 于 H2O 中，pH － 于 KCl 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤、土体","methodology_zh":"pH － 于 H2O 中，pH － 于 KCl 中"},{"_id":"6a832355884ede9a1b2c4eab","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(50 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (50 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Substancje rozpuszczone\nZakres (50 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Substancje rozpuszczone\nZakres (50 – 2000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(50 – 2000) mg/l"}],"search_en":"Water, wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(50 – 2000) mg/l"}],"search_zh":"水、废水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性固体"},{"_id":"6a832355884ede9a1b2c4eac","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a832355884ede9a1b2c4ead","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5,","parameters":[{"name":"Zakres","range":"(1,0 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5,\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5,\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5,\nZakres (1,0 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5,","parameters_en":[{"name":"Range","range":"(1,0 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand - BOD5, Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 6000) mg/l O2"}],"search_zh":"水、废水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eae","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 250) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,04 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 11732:2007 Woda, scieki Stezenie azotu amonowego\nZakres (0,04 – 250) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 11732:2007","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 250) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 11732:2007","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 250) mg/l"}],"search_zh":"水、废水 氨氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 11732:2007","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eaf","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie jonu amonowego (amoniaku) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (amoniaku) (z obliczeń)","reference":"PN-EN ISO 11732:2007","norm_bases":["PN-EN ISO 11732:2007"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie jonu amonowego (amoniaku) (z obliczeń) PN-EN ISO 11732:2007 Woda, scieki Stezenie jonu amonowego (amoniaku) (z obliczen) PN-EN ISO 11732:2007","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion (ammonia) concentration (calculated)","search_en":"Water, wastewater Ammonium ion (ammonia) concentration (calculated) PN-EN ISO 11732:2007","test_object_en":"Water, wastewater","search_zh":"水、废水 PN-EN ISO 11732:2007","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 2,5) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 2,5) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotynowego\nZakres (0,0020 – 2,5) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 2,5) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 2,5) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,0070 – 8,2) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,0070 – 8,2) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotynów\nZakres (0,0070 – 8,2) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotynow\nZakres (0,0070 – 8,2) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,0070 – 8,2) mg/l"}],"search_en":"Water, wastewater Nitrite concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,0070 – 8,2) mg/l"}],"search_zh":"水、废水 亚硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 250) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,20 – 250) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotu azotanowego\nZakres (0,20 – 250) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 250) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 250) mg/l"}],"search_zh":"水、废水 硝态氮浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb3","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,90 – 1100) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,90 – 1100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 13395:2001","norm_bases":["PN-EN ISO 13395:2001"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotanów\nZakres (0,90 – 1100) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 13395:2001 Woda, scieki Stezenie azotanow\nZakres (0,90 – 1100) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 13395:2001","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,90 – 1100) mg/l"}],"search_en":"Water, wastewater Nitrate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 13395:2001","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,90 – 1100) mg/l"}],"search_zh":"水、废水 硝酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 13395:2001","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb4","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026 r."],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 r. Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026 r.","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb5","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków wolnych","parameters":[{"name":"Zakres","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków wolnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda, scieki Stezenie cyjankow wolnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free cyanide concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,0) mg/l"}],"search_en":"Water, wastewater Free cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 1,0) mg/l"}],"search_zh":"水、废水 游离氰化物浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"游离氰化物浓度"},{"_id":"6a832355884ede9a1b2c4eb6","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków ogólnych","parameters":[{"name":"Zakres","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie cyjanków ogólnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków ogólnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14403-2:2012 Woda, scieki Stezenie cyjankow ogolnych\nZakres (0,01 – 1,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14403-2:2012","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total cyanide concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,0) mg/l"}],"search_en":"Water, wastewater Total cyanide concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14403-2:2012","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,01 – 1,0) mg/l"}],"search_zh":"水、废水 总氰化物浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14403-2:2012","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"总氰化物浓度"},{"_id":"6a832355884ede9a1b2c4eb7","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie cyjanków związanych (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie cyjanków związanych (z obliczeń)","reference":"PN-EN ISO 14403-2:2012","norm_bases":["PN-EN ISO 14403-2:2012"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie cyjanków związanych (z obliczeń) PN-EN ISO 14403-2:2012 Woda, scieki Stezenie cyjankow zwiazanych (z obliczen) PN-EN ISO 14403-2:2012","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined cyanide concentration (calculated)","search_en":"Water, wastewater Combined cyanide concentration (calculated) PN-EN ISO 14403-2:2012","test_object_en":"Water, wastewater","search_zh":"水、废水 络合氰化物浓度（由计算得出） PN-EN ISO 14403-2:2012","test_object_zh":"水、废水","methodology_zh":"络合氰化物浓度（由计算得出）"},{"_id":"6a832355884ede9a1b2c4eb8","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,010 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010 – 50) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7+ Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4eb9","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,030 – 300) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,030 – 300) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 15681-2:2019-02","norm_bases":["PN-EN ISO 15681-2:2019-02"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforanów\nZakres (0,030 – 300) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 15681-2:2019-02 Woda, scieki Stezenie fosforanow\nZakres (0,030 – 300) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 15681-2:2019-02","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,030 – 300) mg/l"}],"search_en":"Water, wastewater Phosphate concentration Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 15681-2:2019-02","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,030 – 300) mg/l"}],"search_zh":"水、废水 磷酸盐浓度 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 15681-2:2019-02","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"磷酸盐浓度"},{"_id":"6a832355884ede9a1b2c4eba","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (7,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(7,0 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(7,0 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832355884ede9a1b2c4ebb","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,0010 – 5,0) mg/l"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,0010 – 5,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004","norm_bases":["PN-EN ISO 14402:2004"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,0010 – 5,0) mg/l\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 Woda, scieki Indeks fenolowy\nZakres (0,0010 – 5,0) mg/l\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,0010 – 5,0) mg/l"}],"search_en":"Water, wastewater Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,0010 – 5,0) mg/l"}],"search_zh":"水、废水 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a832355884ede9a1b2c4ebc","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie aldehydu mrówkowego","parameters":[{"name":"Zakres","range":"(0,010 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie aldehydu mrówkowego\nZakres (0,010 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-71/C-04593","norm_bases":["PN-71/C-04593"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie aldehydu mrówkowego\nZakres (0,010 – 2,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04593 Woda, scieki Stezenie aldehydu mrowkowego\nZakres (0,010 – 2,0) mg/l\nMetoda spektrofotometryczna PN-71/C-04593","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Formaldehyde concentration","parameters_en":[{"name":"Range","range":"(0,010 – 2,0) mg/l"}],"search_en":"Water, wastewater Formaldehyde concentration Spectrophotometric method Range PN-71/C-04593","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 2,0) mg/l"}],"search_zh":"水、废水 甲醛浓度 分光光度法 范围 PN-71/C-04593","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"甲醛浓度"},{"_id":"6a832355884ede9a1b2c4ebd","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4ebe","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie:\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 –1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie:\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego\nZakres (1,0 –1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie:\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego\nZakres (1,0 –1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, scieki Stezenie:\n- ogolnego wegla organicznego\n- rozpuszczonego wegla organicznego\nZakres (1,0 –1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration:\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego","parameters_en":[{"name":"Range","range":"(1,0 –1000) mg/l"}],"search_en":"Water, wastewater Concentration:\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(1,0 –1000) mg/l"}],"search_zh":"水、废水 浓度：\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego 红外光谱法（IR） 范围 PN-EN 1484:1999","test_object_zh":"水、废水","technique_zh":"红外光谱法（IR）","methodology_zh":"浓度：\n- ogólnego węgla organicznego\n- rozpuszczonego węgla organicznego"},{"_id":"6a832355884ede9a1b2c4ebf","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Antracen","range":"(0,005 – 0,10) µg/l"},{"name":"fluoranten","range":"(0,005 – 0,10) µg/l"},{"name":"naftalen","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(b)fluoranten","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(k)fluoranten","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(g, h, i)perylen","range":"(0,001 – 0,010) µg/l"},{"name":"indeno(1, 2, 3-cd)piren","range":"(0,001 – 0,010) µg/l"},{"name":"dibenzo(a,h)antracen","range":"(0,001 – 0,010) µg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAntracen (0,005 – 0,10) µg/l\nfluoranten (0,005 – 0,10) µg/l\nnaftalen (0,005 – 0,10) µg/l\nbenzo(b)fluoranten (0,005 – 0,10) µg/l\nbenzo(k)fluoranten (0,005 – 0,10) µg/l\nbenzo(g, h, i)perylen (0,001 – 0,010) µg/l\nindeno(1, 2, 3-cd)piren (0,001 – 0,010) µg/l\ndibenzo(a,h)antracen (0,001 – 0,010) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nAntracen (0,005 – 0,10) µg/l\nfluoranten (0,005 – 0,10) µg/l\nnaftalen (0,005 – 0,10) µg/l\nbenzo(b)fluoranten (0,005 – 0,10) µg/l\nbenzo(k)fluoranten (0,005 – 0,10) µg/l\nbenzo(g, h, i)perylen (0,001 – 0,010) µg/l\nindeno(1, 2, 3-cd)piren (0,001 – 0,010) µg/l\ndibenzo(a,h)antracen (0,001 – 0,010) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda, scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nAntracen (0,005 – 0,10) µg/l\nfluoranten (0,005 – 0,10) µg/l\nnaftalen (0,005 – 0,10) µg/l\nbenzo(b)fluoranten (0,005 – 0,10) µg/l\nbenzo(k)fluoranten (0,005 – 0,10) µg/l\nbenzo(g, h, i)perylen (0,001 – 0,010) µg/l\nindeno(1, 2, 3-cd)piren (0,001 – 0,010) µg/l\ndibenzo(a,h)antracen (0,001 – 0,010) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Anthracene","range":"(0,005 – 0,10) µg/l"},{"name":"fluoranthene","range":"(0,005 – 0,10) µg/l"},{"name":"naphthalene","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(b)fluoranthene","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(k)fluoranthene","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(g, h, i)perylene","range":"(0,001 – 0,010) µg/l"},{"name":"indeno(1, 2, 3-cd)piren","range":"(0,001 – 0,010) µg/l"},{"name":"dibenzo(a,h)anthracene","range":"(0,001 – 0,010) µg/l"}],"search_en":"Water, wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Anthracene fluoranthene naphthalene benzo(b)fluoranthene benzo(k)fluoranthene benzo(g, h, i)perylene dibenzo(a,h)anthracene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water, wastewater","search_zh":"水、废水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 蒽 荧蒽 萘 苯并（b）荧蒽 苯并（k）荧蒽 二苯并（a,h）蒽 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水、废水","parameters_zh":[{"name":"蒽","range":"(0,005 – 0,10) µg/l"},{"name":"荧蒽","range":"(0,005 – 0,10) µg/l"},{"name":"萘","range":"(0,005 – 0,10) µg/l"},{"name":"苯并（b）荧蒽","range":"(0,005 – 0,10) µg/l"},{"name":"苯并（k）荧蒽","range":"(0,005 – 0,10) µg/l"},{"name":"benzo(g, h, i)perylen","range":"(0,001 – 0,010) µg/l"},{"name":"indeno(1, 2, 3-cd)piren","range":"(0,001 – 0,010) µg/l"},{"name":"二苯并（a,h）蒽","range":"(0,001 – 0,010) µg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832355884ede9a1b2c4ec0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego:","parameters":[{"name":"Zakres","range":"(0,010 – 50) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie fosforu ogólnego:\nZakres (0,010 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego:\nZakres (0,010 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie fosforu ogolnego:\nZakres (0,010 – 50) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,010 – 50) mg/l"}],"search_en":"Water, wastewater Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 50) mg/l"}],"search_zh":"水、废水 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a832355884ede9a1b2c4ec1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki,\nwody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki,\nwody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki,\nwody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Water, wastewater,\nwody opadowe, wody roztopowe Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater,\nwody opadowe, wody roztopowe","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法"},{"_id":"6a832355884ede9a1b2c4ec2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda, ścieki,\nwody opadowe, wody roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,05 – 50,0) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,05 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki,\nwody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,05 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki,\nwody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,05 – 50,0) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,05 – 50,0) mg/l"}],"search_en":"Water, wastewater,\nwody opadowe, wody roztopowe Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater,\nwody opadowe, wody roztopowe","parameters_zh":[{"name":"范围","range":"(0,05 – 50,0) mg/l"}],"search_zh":"矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数"},{"_id":"6a832355884ede9a1b2c4ec3","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"benzo(a)piren","range":"(0,00011 – 0,10) µg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,00011 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,00011 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nbenzo(a)piren (0,00011 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"benzo(a)pyrene","range":"(0,00011 – 0,10) µg/l"}],"search_en":"Water Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(a)pyrene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water","search_zh":"水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（a）芘 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水","parameters_zh":[{"name":"苯并（a）芘","range":"(0,00011 – 0,10) µg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832355884ede9a1b2c4ec4","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"benzo(a)piren","range":"(0,005 – 0,10) µg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,005 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nbenzo(a)piren (0,005 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Scieki Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nbenzo(a)piren (0,005 – 0,10) µg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"benzo(a)pyrene","range":"(0,005 – 0,10) µg/l"}],"search_en":"Wastewater Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(a)pyrene PN-EN ISO 17993:2005","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Wastewater","search_zh":"污水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（a）芘 PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"污水","parameters_zh":[{"name":"苯并（a）芘","range":"(0,005 – 0,10) µg/l"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a832355884ede9a1b2c4ec5","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"antymon","range":"(0,050 – 100) mg/l"},{"name":"arsen","range":"(0,010 – 100) mg/l"},{"name":"bar","range":"(0,050 – 100) mg/l"},{"name":"beryl","range":"(0,050 – 100) mg/l"},{"name":"bor","range":"(0,050 – 100) mg/l"},{"name":"chrom ogólny","range":"(0,050 – 100) mg/l"},{"name":"cyna","range":"(0,050 – 100) mg/l"},{"name":"cynk","range":"(0,050 – 100) mg/l"},{"name":"glin","range":"(0,050 – 100) mg/l"},{"name":"kadm","range":"(0,010 – 100) mg/l"},{"name":"kobalt","range":"(0,010 – 100) mg/l"},{"name":"mangan","range":"(0,050 – 100) mg/l"},{"name":"miedź","range":"(0,010 – 100) mg/l"},{"name":"molibden","range":"(0,050 – 100) mg/l"},{"name":"nikiel","range":"(0,010 – 100) mg/l"},{"name":"ołów","range":"(0,010 – 100) mg/l"},{"name":"potas","range":"(1,0 – 1000) mg/l"},{"name":"selen","range":"(0,050 – 100) mg/l"},{"name":"sód","range":"(1,0 – 1000) mg/l"},{"name":"srebro","range":"(0,025 – 100) mg/l"},{"name":"tal","range":"(0,050 – 100) mg/l"},{"name":"tytan","range":"(0,050 – 100) mg/l"},{"name":"wanad","range":"(0,050 – 100) mg/l"},{"name":"żelazo","range":"(0,050 – 100) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nantymon (0,050 – 100) mg/l\narsen (0,010 – 100) mg/l\nbar (0,050 – 100) mg/l\nberyl (0,050 – 100) mg/l\nbor (0,050 – 100) mg/l\nchrom ogólny (0,050 – 100) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,050 – 100) mg/l\nglin (0,050 – 100) mg/l\nkadm (0,010 – 100) mg/l\nkobalt (0,010 – 100) mg/l\nmangan (0,050 – 100) mg/l\nmiedź (0,010 – 100) mg/l\nmolibden (0,050 – 100) mg/l\nnikiel (0,010 – 100) mg/l\nołów (0,010 – 100) mg/l\npotas (1,0 – 1000) mg/l\nselen (0,050 – 100) mg/l\nsód (1,0 – 1000) mg/l\nsrebro (0,025 – 100) mg/l\ntal (0,050 – 100) mg/l\ntytan (0,050 – 100) mg/l\nwanad (0,050 – 100) mg/l\nżelazo (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nantymon (0,050 – 100) mg/l\narsen (0,010 – 100) mg/l\nbar (0,050 – 100) mg/l\nberyl (0,050 – 100) mg/l\nbor (0,050 – 100) mg/l\nchrom ogólny (0,050 – 100) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,050 – 100) mg/l\nglin (0,050 – 100) mg/l\nkadm (0,010 – 100) mg/l\nkobalt (0,010 – 100) mg/l\nmangan (0,050 – 100) mg/l\nmiedź (0,010 – 100) mg/l\nmolibden (0,050 – 100) mg/l\nnikiel (0,010 – 100) mg/l\nołów (0,010 – 100) mg/l\npotas (1,0 – 1000) mg/l\nselen (0,050 – 100) mg/l\nsód (1,0 – 1000) mg/l\nsrebro (0,025 – 100) mg/l\ntal (0,050 – 100) mg/l\ntytan (0,050 – 100) mg/l\nwanad (0,050 – 100) mg/l\nżelazo (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nantymon (0,050 – 100) mg/l\narsen (0,010 – 100) mg/l\nbar (0,050 – 100) mg/l\nberyl (0,050 – 100) mg/l\nbor (0,050 – 100) mg/l\nchrom ogolny (0,050 – 100) mg/l\ncyna (0,050 – 100) mg/l\ncynk (0,050 – 100) mg/l\nglin (0,050 – 100) mg/l\nkadm (0,010 – 100) mg/l\nkobalt (0,010 – 100) mg/l\nmangan (0,050 – 100) mg/l\nmiedz (0,010 – 100) mg/l\nmolibden (0,050 – 100) mg/l\nnikiel (0,010 – 100) mg/l\nolow (0,010 – 100) mg/l\npotas (1,0 – 1000) mg/l\nselen (0,050 – 100) mg/l\nsod (1,0 – 1000) mg/l\nsrebro (0,025 – 100) mg/l\ntal (0,050 – 100) mg/l\ntytan (0,050 – 100) mg/l\nwanad (0,050 – 100) mg/l\nzelazo (0,050 – 100) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"antimony","range":"(0,050 – 100) mg/l"},{"name":"arsenic","range":"(0,010 – 100) mg/l"},{"name":"barium","range":"(0,050 – 100) mg/l"},{"name":"beryllium","range":"(0,050 – 100) mg/l"},{"name":"boron","range":"(0,050 – 100) mg/l"},{"name":"total chromium","range":"(0,050 – 100) mg/l"},{"name":"tin","range":"(0,050 – 100) mg/l"},{"name":"zinc","range":"(0,050 – 100) mg/l"},{"name":"aluminium","range":"(0,050 – 100) mg/l"},{"name":"cadmium","range":"(0,010 – 100) mg/l"},{"name":"cobalt","range":"(0,010 – 100) mg/l"},{"name":"manganese","range":"(0,050 – 100) mg/l"},{"name":"copper","range":"(0,010 – 100) mg/l"},{"name":"molybdenum","range":"(0,050 – 100) mg/l"},{"name":"nickel","range":"(0,010 – 100) mg/l"},{"name":"lead","range":"(0,010 – 100) mg/l"},{"name":"potassium","range":"(1,0 – 1000) mg/l"},{"name":"selenium","range":"(0,050 – 100) mg/l"},{"name":"sodium","range":"(1,0 – 1000) mg/l"},{"name":"silver","range":"(0,025 – 100) mg/l"},{"name":"thallium","range":"(0,050 – 100) mg/l"},{"name":"titanium","range":"(0,050 – 100) mg/l"},{"name":"vanadium","range":"(0,050 – 100) mg/l"},{"name":"iron","range":"(0,050 – 100) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) antimony arsenic barium beryllium boron total chromium tin zinc aluminium cadmium cobalt manganese copper molybdenum nickel lead potassium selenium sodium silver thallium titanium vanadium iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"锑","range":"(0,050 – 100) mg/l"},{"name":"砷","range":"(0,010 – 100) mg/l"},{"name":"钡","range":"(0,050 – 100) mg/l"},{"name":"铍","range":"(0,050 – 100) mg/l"},{"name":"硼","range":"(0,050 – 100) mg/l"},{"name":"总铬","range":"(0,050 – 100) mg/l"},{"name":"锡","range":"(0,050 – 100) mg/l"},{"name":"锌","range":"(0,050 – 100) mg/l"},{"name":"铝","range":"(0,050 – 100) mg/l"},{"name":"镉","range":"(0,010 – 100) mg/l"},{"name":"钴","range":"(0,010 – 100) mg/l"},{"name":"锰","range":"(0,050 – 100) mg/l"},{"name":"铜","range":"(0,010 – 100) mg/l"},{"name":"钼","range":"(0,050 – 100) mg/l"},{"name":"镍","range":"(0,010 – 100) mg/l"},{"name":"铅","range":"(0,010 – 100) mg/l"},{"name":"钾","range":"(1,0 – 1000) mg/l"},{"name":"硒","range":"(0,050 – 100) mg/l"},{"name":"钠","range":"(1,0 – 1000) mg/l"},{"name":"银","range":"(0,025 – 100) mg/l"},{"name":"铊","range":"(0,050 – 100) mg/l"},{"name":"钛","range":"(0,050 – 100) mg/l"},{"name":"钒","range":"(0,050 – 100) mg/l"},{"name":"铁","range":"(0,050 – 100) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 锑 砷 钡 铍 硼 总铬 锡 锌 铝 镉 钴 锰 铜 钼 镍 铅 钾 硒 钠 银 铊 钛 钒 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a832355884ede9a1b2c4ec6","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość (sucha masa)","parameters":[{"name":"Zakres","range":"(5,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość (sucha masa)\nZakres (5,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 metoda A","norm_bases":["PN-EN ISO 11465:2026-03 metoda A"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość (sucha masa)\nZakres (5,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A Osady sciekowe Sucha pozostalosc (sucha masa)\nZakres (5,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue (dry matter)","parameters_en":[{"name":"Range","range":"(5,0 – 99,9) %"}],"search_en":"Sewage sludge Dry residue (dry matter) Gravimetric method Range PN-EN ISO 11465:2026-03 metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 99,9) %"}],"search_zh":"污泥 干残渣（干物质） 重量法 范围 PN-EN ISO 11465:2026-03 metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣（干物质）"},{"_id":"6a832355884ede9a1b2c4ec7","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (zawartość substancji organicznych)","parameters":[{"name":"Zakres","range":"(2,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (zawartość substancji organicznych)\nZakres (2,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (zawartość substancji organicznych)\nZakres (2,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (zawartosc substancji organicznych)\nZakres (2,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (organic matter content)","parameters_en":[{"name":"Range","range":"(2,0 – 95,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (organic matter content) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(2,0 – 95,0) %"}],"search_zh":"污泥 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a832355884ede9a1b2c4ec8","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(30,0 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (30,0 – 99,9) %\nMetoda wagowa","reference":"PN-EN ISO 11465:2026-03 metoda A","norm_bases":["PN-EN ISO 11465:2026-03 metoda A"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Sucha masa\nZakres (30,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A Gleba, grunty Sucha masa\nZakres (30,0 – 99,9) %\nMetoda wagowa PN-EN ISO 11465:2026-03 metoda A","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(30,0 – 99,9) %"}],"search_en":"Soil, ground Dry matter Gravimetric method Range PN-EN ISO 11465:2026-03 metoda A","technique_en":"Gravimetric method","test_object_en":"Soil, ground","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(30,0 – 99,9) %"}],"search_zh":"土壤、土体 干物质 重量法 范围 PN-EN ISO 11465:2026-03 metoda A","technique_zh":"重量法","test_object_zh":"土壤、土体"},{"_id":"6a832355884ede9a1b2c4ec9","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość wody (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN ISO 11465:2026-03 metoda A","norm_bases":["PN-EN ISO 11465:2026-03 metoda A"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość wody (z obliczeń) PN-EN ISO 11465:2026-03 metoda A Gleba, grunty Zawartosc wody (z obliczen) PN-EN ISO 11465:2026-03 metoda A","categories":["water","environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content (calculated)","search_en":"Soil, ground Water content (calculated) PN-EN ISO 11465:2026-03 metoda A","test_object_en":"Soil, ground","search_zh":"土壤、土体 水分含量（计算值） PN-EN ISO 11465:2026-03 metoda A","test_object_zh":"土壤、土体","methodology_zh":"水分含量（计算值）"},{"_id":"6a832355884ede9a1b2c4eca","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Zawartość pierwiastków","parameters":[{"name":"arsen","range":"(0,50 – 1000) mg/kg"},{"name":"bar","range":"(2,50 – 1000) mg/kg"},{"name":"chrom ogólny","range":"(2,50 – 1000) mg/kg"},{"name":"cyna","range":"(0,50 – 1000) mg/kg"},{"name":"cynk","range":"(2,50 – 4000) mg/kg"},{"name":"kadm","range":"(0,50 – 1000) mg/kg"},{"name":"kobalt","range":"(0,50 – 1000) mg/kg"},{"name":"miedź","range":"(2,50 – 2000) mg/kg"},{"name":"molibden","range":"(0,50 – 1000) mg/kg"},{"name":"nikiel","range":"(2,50 – 1000) mg/kg"},{"name":"ołów","range":"(2,50 – 1000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogólny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","norm_bases":["PN-EN ISO 22036:2024-07","PN-EN ISO 54321:2021-07 metoda B"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Zawartość pierwiastków\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogólny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B Gleba, grunty Zawartosc pierwiastkow\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogolny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedz (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nolow (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","categories":["materials","environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"arsenic","range":"(0,50 – 1000) mg/kg"},{"name":"barium","range":"(2,50 – 1000) mg/kg"},{"name":"total chromium","range":"(2,50 – 1000) mg/kg"},{"name":"tin","range":"(0,50 – 1000) mg/kg"},{"name":"zinc","range":"(2,50 – 4000) mg/kg"},{"name":"cadmium","range":"(0,50 – 1000) mg/kg"},{"name":"cobalt","range":"(0,50 – 1000) mg/kg"},{"name":"copper","range":"(2,50 – 2000) mg/kg"},{"name":"molybdenum","range":"(0,50 – 1000) mg/kg"},{"name":"nickel","range":"(2,50 – 1000) mg/kg"},{"name":"lead","range":"(2,50 – 1000) mg/kg"}],"search_en":"Soil, ground Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic barium total chromium tin zinc cadmium cobalt copper molybdenum nickel lead PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Soil, ground","methodology_zh":"元素含量","parameters_zh":[{"name":"砷","range":"(0,50 – 1000) mg/kg"},{"name":"钡","range":"(2,50 – 1000) mg/kg"},{"name":"总铬","range":"(2,50 – 1000) mg/kg"},{"name":"锡","range":"(0,50 – 1000) mg/kg"},{"name":"锌","range":"(2,50 – 4000) mg/kg"},{"name":"镉","range":"(0,50 – 1000) mg/kg"},{"name":"钴","range":"(0,50 – 1000) mg/kg"},{"name":"铜","range":"(2,50 – 2000) mg/kg"},{"name":"钼","range":"(0,50 – 1000) mg/kg"},{"name":"镍","range":"(2,50 – 1000) mg/kg"},{"name":"铅","range":"(2,50 – 1000) mg/kg"}],"search_zh":"土壤、土体 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 钡 总铬 锡 锌 镉 钴 铜 钼 镍 铅 PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤、土体"},{"_id":"6a832355884ede9a1b2c4ecb","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.","parameters":[{"name":"Zakres","range":"od 1 szt./50 g"}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres od 1 szt./50 g\nMetoda flotacji, mikroskopowa","reference":"PB-09/CLB wydanie 1 z dnia 30.05.2022","norm_bases":["PB-09/CLB wydanie 1 z dnia 30.05.2022"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres od 1 szt./50 g\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022 Osady sciekowe Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Trichuris sp. i Toxocara sp.\nZakres od 1 szt./50 g\nMetoda flotacji, mikroskopowa PB-09/CLB wydanie 1 z dnia 30.05.2022","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp.","parameters_en":[{"name":"Range","range":"od 1 szt./50 g"}],"search_en":"Sewage sludge Presence and count of viable eggs of intestinal parasites Ascaris sp., Trichuris sp. and Toxocara sp. Flotation method, microscopic Range PB-09/CLB wydanie 1 z dnia 30.05.2022","technique_en":"Flotation method, microscopic","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"od 1 szt./50 g"}],"search_zh":"污泥 浮选显微镜法 范围 PB-09/CLB wydanie 1 z dnia 30.05.2022","test_object_zh":"污泥","technique_zh":"浮选显微镜法"},{"_id":"6a832355884ede9a1b2c4ecc","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość stałych związków rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(500 – 20000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość stałych związków rozpuszczonych (TDS)\nZakres (500 – 20000) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość stałych związków rozpuszczonych (TDS)\nZakres (500 – 20000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc stalych zwiazkow rozpuszczonych (TDS)\nZakres (500 – 20000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids content (TDS)","parameters_en":[{"name":"Range","range":"(500 – 20000) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Total dissolved solids content (TDS) Gravimetric method Range PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Gravimetric method","test_object_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(500 – 20000) mg/kg"}],"search_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 溶解性总固体含量（TDS） 重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"重量法","test_object_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"溶解性总固体含量（TDS）"},{"_id":"6a832355884ede9a1b2c4ecd","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość rozpuszczonego węgla organicznego (DOC)","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/kg"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Zawartość rozpuszczonego węgla organicznego (DOC)\nZakres (10 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN 1484:1999","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość rozpuszczonego węgla organicznego (DOC)\nZakres (10 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc rozpuszczonego wegla organicznego (DOC)\nZakres (10 – 10000) mg/kg\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved organic carbon (DOC) content","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Dissolved organic carbon (DOC) content Infrared spectrometry method (IR) Range PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Infrared spectrometry method (IR)","test_object_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/kg"}],"search_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 溶解性有机碳（DOC）含量 红外光谱法（IR） 范围 PN-EN 1484:1999 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","test_object_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","technique_zh":"红外光谱法（IR）","methodology_zh":"溶解性有机碳（DOC）含量"},{"_id":"6a832355884ede9a1b2c4ece","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,01 – 50) mg/kg"}],"technique":"Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","techniques":["Metoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,01 – 50) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną","reference":"PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 14402:2004","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Indeks fenolowy\nZakres (0,01 – 50) mg/kg\nMetoda ciągłej analizy przepływowej (CFA) z detekcją spektrofotometryczną PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod 17 05 04\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Indeks fenolowy\nZakres (0,01 – 50) mg/kg\nMetoda ciaglej analizy przeplywowej (CFA) z detekcja spektrofotometryczna PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,01 – 50) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Phenol index Continuous flow analysis (CFA) with spectrophotometric detection Range PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Continuous flow analysis (CFA) with spectrophotometric detection","test_object_en":"Soil, ground\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(0,01 – 50) mg/kg"}],"search_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 酚指数 连续流动分析（CFA）分光光度检测法 范围 PN-EN ISO 14402:2004 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"连续流动分析（CFA）分光光度检测法","test_object_zh":"土壤、土体\nOdpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"酚指数"},{"_id":"6a832355884ede9a1b2c4ecf","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Odpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"arsen","range":"(0,50 – 1000) mg/kg"},{"name":"bar","range":"(2,50 – 1000) mg/kg"},{"name":"chrom ogólny","range":"(2,50 – 1000) mg/kg"},{"name":"cyna","range":"(0,50 – 1000) mg/kg"},{"name":"cynk","range":"(2,50 – 4000) mg/kg"},{"name":"kadm","range":"(0,50 – 1000) mg/kg"},{"name":"kobalt","range":"(0,50 – 1000) mg/kg"},{"name":"miedź","range":"(2,50 – 2000) mg/kg"},{"name":"molibden","range":"(0,50 – 1000) mg/kg"},{"name":"nikiel","range":"(2,50 – 1000) mg/kg"},{"name":"ołów","range":"(2,50 – 1000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogólny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","norm_bases":["PN-EN ISO 22036:2024-07","PN-EN ISO 54321:2021-07 metoda B"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O): kod 17 05 04\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogólny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B Odpady O): kod 17 05 04\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\narsen (0,50 – 1000) mg/kg\nbar (2,50 – 1000) mg/kg\nchrom ogolny (2,50 – 1000) mg/kg\ncyna (0,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nkobalt (0,50 – 1000) mg/kg\nmiedz (2,50 – 2000) mg/kg\nmolibden (0,50 – 1000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nolow (2,50 – 1000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","categories":["environment","materials"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"arsenic","range":"(0,50 – 1000) mg/kg"},{"name":"barium","range":"(2,50 – 1000) mg/kg"},{"name":"total chromium","range":"(2,50 – 1000) mg/kg"},{"name":"tin","range":"(0,50 – 1000) mg/kg"},{"name":"zinc","range":"(2,50 – 4000) mg/kg"},{"name":"cadmium","range":"(0,50 – 1000) mg/kg"},{"name":"cobalt","range":"(0,50 – 1000) mg/kg"},{"name":"copper","range":"(2,50 – 2000) mg/kg"},{"name":"molybdenum","range":"(0,50 – 1000) mg/kg"},{"name":"nickel","range":"(2,50 – 1000) mg/kg"},{"name":"lead","range":"(2,50 – 1000) mg/kg"}],"search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) arsenic barium total chromium tin zinc cadmium cobalt copper molybdenum nickel lead PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","parameters_zh":[{"name":"砷","range":"(0,50 – 1000) mg/kg"},{"name":"钡","range":"(2,50 – 1000) mg/kg"},{"name":"总铬","range":"(2,50 – 1000) mg/kg"},{"name":"锡","range":"(0,50 – 1000) mg/kg"},{"name":"锌","range":"(2,50 – 4000) mg/kg"},{"name":"镉","range":"(0,50 – 1000) mg/kg"},{"name":"钴","range":"(0,50 – 1000) mg/kg"},{"name":"铜","range":"(2,50 – 2000) mg/kg"},{"name":"钼","range":"(0,50 – 1000) mg/kg"},{"name":"镍","range":"(2,50 – 1000) mg/kg"},{"name":"铅","range":"(2,50 – 1000) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 砷 钡 总铬 锡 锌 镉 钴 铜 钼 镍 铅 PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a832355884ede9a1b2c4ed0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe\nOdpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość pierwiastków","parameters":[{"name":"chrom","range":"(2,50 – 1000) mg/kg"},{"name":"cynk","range":"(2,50 – 4000) mg/kg"},{"name":"kadm","range":"(0,50 – 1000) mg/kg"},{"name":"miedź","range":"(2,50 – 2000) mg/kg"},{"name":"nikiel","range":"(2,50 – 1000) mg/kg"},{"name":"ołów","range":"(2,50 – 1000) mg/kg"},{"name":"fosfor ogólny","range":"(0,025 – 4,0) %"},{"name":"magnez","range":"(0,010 – 1,0) %"},{"name":"wapń","range":"(0,025 – 10,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nchrom (2,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nfosfor ogólny (0,025 – 4,0) %\nmagnez (0,010 – 1,0) %\nwapń (0,025 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","norm_bases":["PN-EN ISO 22036:2024-07","PN-EN ISO 54321:2021-07 metoda B"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe\nOdpady O): kod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość pierwiastków\nZakres:\nchrom (2,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nmiedź (2,50 – 2000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nołów (2,50 – 1000) mg/kg\nfosfor ogólny (0,025 – 4,0) %\nmagnez (0,010 – 1,0) %\nwapń (0,025 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B Osady sciekowe\nOdpady O): kod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc pierwiastkow\nZakres:\nchrom (2,50 – 1000) mg/kg\ncynk (2,50 – 4000) mg/kg\nkadm (0,50 – 1000) mg/kg\nmiedz (2,50 – 2000) mg/kg\nnikiel (2,50 – 1000) mg/kg\nolow (2,50 – 1000) mg/kg\nfosfor ogolny (0,025 – 4,0) %\nmagnez (0,010 – 1,0) %\nwapn (0,025 – 10,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","categories":["environment","water","materials"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"chromium","range":"(2,50 – 1000) mg/kg"},{"name":"zinc","range":"(2,50 – 4000) mg/kg"},{"name":"cadmium","range":"(0,50 – 1000) mg/kg"},{"name":"copper","range":"(2,50 – 2000) mg/kg"},{"name":"nickel","range":"(2,50 – 1000) mg/kg"},{"name":"lead","range":"(2,50 – 1000) mg/kg"},{"name":"total phosphorus","range":"(0,025 – 4,0) %"},{"name":"magnesium","range":"(0,010 – 1,0) %"},{"name":"calcium","range":"(0,025 – 10,0) %"}],"search_en":"Sewage sludge\nWaste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) chromium zinc cadmium copper nickel lead total phosphorus magnesium calcium PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge\nWaste O): code 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"元素含量","parameters_zh":[{"name":"铬","range":"(2,50 – 1000) mg/kg"},{"name":"锌","range":"(2,50 – 4000) mg/kg"},{"name":"镉","range":"(0,50 – 1000) mg/kg"},{"name":"铜","range":"(2,50 – 2000) mg/kg"},{"name":"镍","range":"(2,50 – 1000) mg/kg"},{"name":"铅","range":"(2,50 – 1000) mg/kg"},{"name":"总磷","range":"(0,025 – 4,0) %"},{"name":"镁","range":"(0,010 – 1,0) %"},{"name":"钙","range":"(0,025 – 10,0) %"}],"search_zh":"污泥\n废物 O)：代码 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 锌 镉 铜 镍 铅 总磷 镁 钙 PN-EN ISO 22036:2024-07 | PN-EN ISO 54321:2021-07 metoda B","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污泥\n废物 O)：代码 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów"},{"_id":"6a832355884ede9a1b2c4ed1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,001 – 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,001 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PB-04/KR wydanie 1 z dnia 02.03.2020 r.","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. Zawartość rtęci\nZakres (0,001 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod 17 05 04*)\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow\n*) Akredytacja zawieszona na wniosek podmiotu w czesci zakresu oznaczonego pogrubiona kursywa od 03.06.2025 r. do 25.11.2026r. Zawartosc rteci\nZakres (0,001 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,001 – 5,0) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil, ground\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,001 – 5,0) mg/kg"}],"search_zh":"土壤、土体\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. 汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-04/KR wydanie 1 z dnia 02.03.2020 r. | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"土壤、土体\nOdpady O): kod 17 05 04*)\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r."},{"_id":"6a832355884ede9a1b2c4ed2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty, osady ściekowe*)\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,010 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB-04/KR wydanie 1 z dnia 02.03.2020 r.","norm_bases":["PB-04/KR wydanie 1 z dnia 02.03.2020 r."],"lab_section":"Pracownia w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty, osady ściekowe*)\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. Zawartość rtęci\nZakres (0,010 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB-04/KR wydanie 1 z dnia 02.03.2020 r. Gleba, grunty, osady sciekowe*)\n*) Akredytacja zawieszona na wniosek podmiotu w czesci zakresu oznaczonego pogrubiona kursywa od 03.06.2025 r. do 25.11.2026r. Zawartosc rteci\nZakres (0,010 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB-04/KR wydanie 1 z dnia 02.03.2020 r.","categories":["water","environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/kg"}],"search_en":"Soil, ground, sewage sludge*)\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r. Mercury content Atomic absorption spectrometry with amalgamation technique Range PB-04/KR wydanie 1 z dnia 02.03.2020 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Soil, ground, sewage sludge*)\n*) Akredytacja zawieszona na wniosek podmiotu w części zakresu oznaczonego pogrubioną kursywą od 03.06.2025 r. do 25.11.2026r.","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/kg"}],"search_zh":"汞含量 原子吸收光谱法（汞齐化技术） 范围 PB-04/KR wydanie 1 z dnia 02.03.2020 r.","technique_zh":"原子吸收光谱法（汞齐化技术）"},{"_id":"6a832355884ede9a1b2c4ed3","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów:","parameters":[{"name":"fluorki","range":"(0,050 – 0,60) mg/l"},{"name":"chlorki","range":"(0,20 – 3000) mg/l"},{"name":"azotany","range":"(0,20 – 100) mg/l"},{"name":"azot azotanowy","range":"(0,050 – 23,0) mg/l"},{"name":"siarczany","range":"(0,20 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nfluorki (0,050 – 0,60) mg/l\nchlorki (0,20 – 3000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów:\nZakres:\nfluorki (0,050 – 0,60) mg/l\nchlorki (0,20 – 3000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow:\nZakres:\nfluorki (0,050 – 0,60) mg/l\nchlorki (0,20 – 3000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"fluorides","range":"(0,050 – 0,60) mg/l"},{"name":"chlorides","range":"(0,20 – 3000) mg/l"},{"name":"nitrates","range":"(0,20 – 100) mg/l"},{"name":"nitrate nitrogen","range":"(0,050 – 23,0) mg/l"},{"name":"sulfates","range":"(0,20 – 1000) mg/l"}],"search_en":"Water Anion concentrations: Ion chromatography with conductometric detection (IC-CD) fluorides chlorides nitrates nitrate nitrogen sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度：","search_zh":"水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 硝酸盐 硝酸盐氮 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"氟化物","range":"(0,050 – 0,60) mg/l"},{"name":"氯化物","range":"(0,20 – 3000) mg/l"},{"name":"硝酸盐","range":"(0,20 – 100) mg/l"},{"name":"硝酸盐氮","range":"(0,050 – 23,0) mg/l"},{"name":"硫酸盐","range":"(0,20 – 1000) mg/l"}]},{"_id":"6a832355884ede9a1b2c4ed4","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,0 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,0 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (7,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(7,0 – 150) mg/l O2"}],"search_en":"Water Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(7,0 – 150) mg/l O2"}],"search_zh":"水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832355884ede9a1b2c4ed5","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(30 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (30 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Substancje rozpuszczone\nZakres (30 – 500) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda Substancje rozpuszczone\nZakres (30 – 500) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(30 – 500) mg/l"}],"search_en":"Water Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(30 – 500) mg/l"}],"search_zh":"水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水","methodology_zh":"溶解性固体"},{"_id":"6a832355884ede9a1b2c4ed6","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(3,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (3,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (3,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (3,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,0 – 100) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 – 100) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a832355884ede9a1b2c4ed7","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(4,0 – 130) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (4,0 – 130) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie jonu amonowego\nZakres (4,0 – 130) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie jonu amonowego\nZakres (4,0 – 130) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(4,0 – 130) mg/l"}],"search_en":"Wastewater Ammonium ion concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(4,0 – 130) mg/l"}],"search_zh":"污水 铵离子浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a832355884ede9a1b2c4ed8","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(0,20 – 1000) mg/l"},{"name":"azotany","range":"(0,20 – 100) mg/l"},{"name":"azot azotanowy","range":"(0,050 – 23,0) mg/l"},{"name":"siarczany","range":"(0,20 – 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (0,20 – 1000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nchlorki (0,20 – 1000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow\nZakres:\nchlorki (0,20 – 1000) mg/l\nazotany (0,20 – 100) mg/l\nazot azotanowy (0,050 – 23,0) mg/l\nsiarczany (0,20 – 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(0,20 – 1000) mg/l"},{"name":"nitrates","range":"(0,20 – 100) mg/l"},{"name":"nitrate nitrogen","range":"(0,050 – 23,0) mg/l"},{"name":"sulfates","range":"(0,20 – 1000) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorides nitrates nitrate nitrogen sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度","search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硝酸盐 硝酸盐氮 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"氯化物","range":"(0,20 – 1000) mg/l"},{"name":"硝酸盐","range":"(0,20 – 100) mg/l"},{"name":"硝酸盐氮","range":"(0,050 – 23,0) mg/l"},{"name":"硫酸盐","range":"(0,20 – 1000) mg/l"}]},{"_id":"6a832355884ede9a1b2c4ed9","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a832355884ede9a1b2c4eda","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda i scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Water and wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water and wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"水与废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4edb","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (1,0 – 50) mg/l\nMetoda wagowa","reference":"PB-10/KR wydanie 1 z dnia 02.03.2020 r.","norm_bases":["PB-10/KR wydanie 1 z dnia 02.03.2020 r."],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Substancje ekstrahujące się eterem naftowym\nZakres (1,0 – 50) mg/l\nMetoda wagowa PB-10/KR wydanie 1 z dnia 02.03.2020 r. Woda i scieki Substancje ekstrahujace sie eterem naftowym\nZakres (1,0 – 50) mg/l\nMetoda wagowa PB-10/KR wydanie 1 z dnia 02.03.2020 r.","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/l"}],"search_en":"Water and wastewater Substances extractable with petroleum ether Gravimetric method Range PB-10/KR wydanie 1 z dnia 02.03.2020 r.","technique_en":"Gravimetric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/l"}],"search_zh":"水与废水 石油醚可萃取物 重量法 范围 PB-10/KR wydanie 1 z dnia 02.03.2020 r.","technique_zh":"重量法","test_object_zh":"水与废水","methodology_zh":"石油醚可萃取物"},{"_id":"6a832355884ede9a1b2c4edc","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,015 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,015 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie ortofosforanów\nZakres (0,015 – 60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 Woda i scieki Stezenie ortofosforanow\nZakres (0,015 – 60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,015 – 60) mg/l"}],"search_en":"Water and wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,015 – 60) mg/l"}],"search_zh":"水与废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","methodology_zh":"正磷酸盐浓度","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4edd","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie ortofosforanów (w przeliczeniu na P)","parameters":[{"name":"Zakres","range":"(0,0050 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów (w przeliczeniu na P)\nZakres (0,0050 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie ortofosforanów (w przeliczeniu na P)\nZakres (0,0050 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010 Woda i scieki Stezenie ortofosforanow (w przeliczeniu na P)\nZakres (0,0050 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration (calculated as P)","parameters_en":[{"name":"Range","range":"(0,0050 – 20) mg/l"}],"search_en":"Water and wastewater Orthophosphate concentration (calculated as P) Spectrophotometric method Range PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,0050 – 20) mg/l"}],"search_zh":"水与废水 分光光度法 范围 PN-EN ISO 6878:2006 p. 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ede","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,020 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie fosforu ogólnego\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010 Woda i scieki Stezenie fosforu ogolnego\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,020 – 20) mg/l"}],"search_en":"Water and wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 20) mg/l"}],"search_zh":"水与废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4edf","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda i scieki Stezenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 10,0) mg/l"}],"search_en":"Water and wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 10,0) mg/l"}],"search_zh":"水与废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,0066 – 33,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,0066 – 33,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotynów\nZakres (0,0066 – 33,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda i scieki Stezenie azotynow\nZakres (0,0066 – 33,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,0066 – 33,0) mg/l"}],"search_en":"Water and wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,0066 – 33,0) mg/l"}],"search_zh":"水与废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu azotanowego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda i scieki Stezenie azotu azotanowego\nZakres (0,10 – 40,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 40,0) mg/l"}],"search_en":"Water and wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 40,0) mg/l"}],"search_zh":"水与废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,44 – 180) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,44 – 180) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotanów\nZakres (0,44 – 180) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda i scieki Stezenie azotanow\nZakres (0,44 – 180) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,44 – 180) mg/l"}],"search_en":"Water and wastewater Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,44 – 180) mg/l"}],"search_zh":"水与废水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee3","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,20 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,20 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu Kjeldahla\nZakres (0,20 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001 Woda i scieki Stezenie azotu Kjeldahla\nZakres (0,20 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 3,0) mg/l"}],"search_en":"Water and wastewater Kjeldahl nitrogen concentration Spectrophotometric method Range PN-EN 25663:2001","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 3,0) mg/l"}],"search_zh":"水与废水 凯氏氮浓度 分光光度法 范围 PN-EN 25663:2001","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee4","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(3,0 – 750) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,0 – 750) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu Kjeldahla\nZakres (3,0 – 750) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda i scieki Stezenie azotu Kjeldahla\nZakres (3,0 – 750) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,0 – 750) mg/l"}],"search_en":"Water and wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water and wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 – 750) mg/l"}],"search_zh":"水与废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee5","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-26/CLB wydanie 1 z dnia 16.01.2026","norm_bases":["PB-26/CLB wydanie 1 z dnia 16.01.2026"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu ogólnego (z obliczeń) PB-26/CLB wydanie 1 z dnia 16.01.2026 Woda i scieki Stezenie azotu ogolnego (z obliczen) PB-26/CLB wydanie 1 z dnia 16.01.2026","categories":["water"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water and wastewater Total nitrogen concentration (calculated) PB-26/CLB wydanie 1 z dnia 16.01.2026","test_object_en":"Water and wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水与废水 总氮浓度（计算值） PB-26/CLB wydanie 1 z dnia 16.01.2026","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee6","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,040 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,040 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 7150-1:2002","norm_bases":["PN ISO 7150-1:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie azotu amonowego\nZakres (0,040 – 3,0) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002 Woda i scieki Stezenie azotu amonowego\nZakres (0,040 – 3,0) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002","categories":["water"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,040 – 3,0) mg/l"}],"search_en":"Water and wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 3,0) mg/l"}],"search_zh":"水与废水 氨氮浓度 分光光度法 范围 PN ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee7","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Stężenie jonu amonowego (amoniaku)","parameters":[{"name":"Zakres","range":"(0,050 – 3,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego (amoniaku)\nZakres (0,050 – 3,9) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 7150-1:2002","norm_bases":["PN ISO 7150-1:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Stężenie jonu amonowego (amoniaku)\nZakres (0,050 – 3,9) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002 Woda i scieki Stezenie jonu amonowego (amoniaku)\nZakres (0,050 – 3,9) mg/l\nMetoda spektrofotometryczna PN ISO 7150-1:2002","categories":["water"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion (ammonia) concentration","parameters_en":[{"name":"Range","range":"(0,050 – 3,9) mg/l"}],"search_en":"Water and wastewater Ammonium ion (ammonia) concentration Spectrophotometric method Range PN ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 3,9) mg/l"}],"search_zh":"水与废水 分光光度法 范围 PN ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水与废水"},{"_id":"6a832355884ede9a1b2c4ee8","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda i scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water and wastewater Biochemical oxygen demand - BOD5, BOD2+5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水与废水 生化需氧量 － BOD5、BOD2+5 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水与废水","methodology_zh":"生化需氧量 － BOD5、BOD2+5"},{"_id":"6a832355884ede9a1b2c4ee9","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Woda i ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (1,0 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda i ścieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (1,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda i scieki Biochemiczne zapotrzebowanie tlenu - BZT5, BZT2+5\nZakres (1,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l O2"}],"search_en":"Water and wastewater Biochemical oxygen demand - BOD5, BOD2+5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water and wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l O2"}],"search_zh":"水与废水 生化需氧量 － BOD5、BOD2+5 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水与废水","methodology_zh":"生化需氧量 － BOD5、BOD2+5"},{"_id":"6a832355884ede9a1b2c4eea","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"pH - w H2O, pH - w KCl","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O, pH - w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty pH - w H2O, pH - w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba, grunty pH - w H2O, pH - w KCl\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O, pH - in KCl","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Soil, ground pH - in H2O, pH - in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"土壤、土体 pH － 于 H2O 中，pH － 于 KCl 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤、土体","methodology_zh":"pH － 于 H2O 中，pH － 于 KCl 中"},{"_id":"6a832355884ede9a1b2c4eeb","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"pH - w H2O","parameters":[{"name":"Zakres","range":"(2,0 – 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH - w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów pH - w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow pH - w H2O\nZakres (2,0 – 12,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment","water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH - in H2O","parameters_en":[{"name":"Range","range":"(2,0 – 12,0)"}],"search_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(2,0 – 12,0)"}],"search_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów pH - 于 H2O 中 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"pH - 于 H2O 中"},{"_id":"6a832355884ede9a1b2c4eec","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,15 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,15 – 5,0) %\nMetoda miareczkowa","reference":"PN-75/C-04576.15","norm_bases":["PN-75/C-04576.15"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość azotu amonowego\nZakres (0,15 – 5,0) %\nMetoda miareczkowa PN-75/C-04576.15 Osady sciekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc azotu amonowego\nZakres (0,15 – 5,0) %\nMetoda miareczkowa PN-75/C-04576.15","categories":["environment","water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,15 – 5,0) %"}],"search_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Ammonium nitrogen content Titrimetric method Range PN-75/C-04576.15","technique_en":"Titrimetric method","test_object_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(0,15 – 5,0) %"}],"search_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 氨氮含量 滴定法 范围 PN-75/C-04576.15","technique_zh":"滴定法","test_object_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"氨氮含量"},{"_id":"6a832355884ede9a1b2c4eed","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Straty przy prażeniu suchej masy (zawartość substancji organicznych)","parameters":[{"name":"Zakres","range":"(1,0 – 95,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (zawartość substancji organicznych)\nZakres (1,0 – 95,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Straty przy prażeniu suchej masy (zawartość substancji organicznych)\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Straty przy prazeniu suchej masy (zawartosc substancji organicznych)\nZakres (1,0 – 95,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment","water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition of dry matter (organic matter content)","parameters_en":[{"name":"Range","range":"(1,0 – 95,0) %"}],"search_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Loss on ignition of dry matter (organic matter content) Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(1,0 – 95,0) %"}],"search_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów"},{"_id":"6a832355884ede9a1b2c4eee","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 4,50)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 4,50)%\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006","norm_bases":["PN-EN 14672:2006"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Stężenie fosforu ogólnego\nZakres (0,10 – 4,50)%\nMetoda spektrofotometryczna PN-EN 14672:2006 Osady sciekowe\nOdpady O):\nkod 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Stezenie fosforu ogolnego\nZakres (0,10 – 4,50)%\nMetoda spektrofotometryczna PN-EN 14672:2006","categories":["environment","water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 4,50)%"}],"search_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Total phosphorus concentration Spectrophotometric method Range PN-EN 14672:2006","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 4,50)%"}],"search_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 总磷浓度 分光光度法 范围 PN-EN 14672:2006","technique_zh":"分光光度法","test_object_zh":"污泥\nOdpady O):\nkod 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów"},{"_id":"6a832355884ede9a1b2c4eef","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty,\nosady ściekowe,\nosad denny","methodology":"Sucha masa i zawartość wody","parameters":[{"name":"Zakres","range":"(0,10 – 99,9) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa i zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty,\nosady ściekowe,\nosad denny Sucha masa i zawartość wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999 Gleba, grunty,\nosady sciekowe,\nosad denny Sucha masa i zawartosc wody\nZakres (0,10 – 99,9) %\nMetoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry matter and water content","parameters_en":[{"name":"Range","range":"(0,10 – 99,9) %"}],"search_en":"Dry matter and water content Gravimetric method Range PN-ISO 11465:1999","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,10 – 99,9) %"}],"search_zh":"干物质与水分含量 重量法 范围 PN-ISO 11465:1999","technique_zh":"重量法","methodology_zh":"干物质与水分含量"},{"_id":"6a832355884ede9a1b2c4ef0","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty,\nosady ściekowe,\nosad denny","methodology":"Zawartość azotu ogólnego","parameters":[{"name":"Zakres","range":"(50 – 80000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego\nZakres (50 – 80000) mg/kg\nMetoda miareczkowa","reference":"PN-ISO 11261:2002","norm_bases":["PN-ISO 11261:2002"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty,\nosady ściekowe,\nosad denny Zawartość azotu ogólnego\nZakres (50 – 80000) mg/kg\nMetoda miareczkowa PN-ISO 11261:2002 Gleba, grunty,\nosady sciekowe,\nosad denny Zawartosc azotu ogolnego\nZakres (50 – 80000) mg/kg\nMetoda miareczkowa PN-ISO 11261:2002","categories":["water","environment"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen content","parameters_en":[{"name":"Range","range":"(50 – 80000) mg/kg"}],"search_en":"Total nitrogen content Titrimetric method Range PN-ISO 11261:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(50 – 80000) mg/kg"}],"search_zh":"总氮含量 滴定法 范围 PN-ISO 11261:2002","technique_zh":"滴定法","methodology_zh":"总氮含量"},{"_id":"6a832355884ede9a1b2c4ef1","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość stałych związków rozpuszczonych (TDS)","parameters":[{"name":"Zakres","range":"(1000 – 250000) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość stałych związków rozpuszczonych (TDS)\nZakres (1000 – 250000) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość stałych związków rozpuszczonych (TDS)\nZakres (1000 – 250000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc stalych zwiazkow rozpuszczonych (TDS)\nZakres (1000 – 250000) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids content (TDS)","parameters_en":[{"name":"Range","range":"(1000 – 250000) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Total dissolved solids content (TDS) Gravimetric method Range PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Gravimetric method","test_object_en":"Soil, ground\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"范围","range":"(1000 – 250000) mg/kg"}],"search_zh":"土壤、土体\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 溶解性总固体含量（TDS） 重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"重量法","test_object_zh":"土壤、土体\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology_zh":"溶解性总固体含量（TDS）"},{"_id":"6a832355884ede9a1b2c4ef2","lab_id":"69ad52a3de79e566650fb157","country":"PL","accr_number":"AB 176","accr_body":"PCA","test_object":"Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","methodology":"Zawartość anionów:","parameters":[{"name":"chlorki","range":"(10 – 40000) mg/kg"},{"name":"fluorki","range":"(0,5 – 20) mg/kg"},{"name":"siarczany","range":"(10 – 80000) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Zawartość anionów:\nZakres:\nchlorki (10 – 40000) mg/kg\nfluorki (0,5 – 20) mg/kg\nsiarczany (10 – 80000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-2:2006","PN-EN 12457-4:2006"],"lab_section":"Pracownia w Nowym Sączu","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Zawartość anionów:\nZakres:\nchlorki (10 – 40000) mg/kg\nfluorki (0,5 – 20) mg/kg\nsiarczany (10 – 80000) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006 Gleba, grunty\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow Zawartosc anionow:\nZakres:\nchlorki (10 – 40000) mg/kg\nfluorki (0,5 – 20) mg/kg\nsiarczany (10 – 80000) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","categories":["environment"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion content:","parameters_en":[{"name":"chlorides","range":"(10 – 40000) mg/kg"},{"name":"fluorides","range":"(0,5 – 20) mg/kg"},{"name":"sulfates","range":"(10 – 80000) mg/kg"}],"search_en":"Soil, ground\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów Anion content: Ion chromatography with conductometric detection (IC-CD) chlorides fluorides sulfates PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Soil, ground\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","search_zh":"土壤、土体\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów 离子色谱-电导检测法（IC-CD） 氯化物 氟化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-2:2006 | PN-EN 12457-4:2006","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"土壤、土体\nOdpady O): kod\n17 05 03, 17 05 04,\n19 08 02, 19 08 05\nO) kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów","parameters_zh":[{"name":"氯化物","range":"(10 – 40000) mg/kg"},{"name":"氟化物","range":"(0,5 – 20) mg/kg"},{"name":"硫酸盐","range":"(10 – 80000) mg/kg"}]}],"has_pdf":true}