🇵🇱 ESC GLOBAL Sp. z o.o. PL

PCA AB 1752 • Dołuje, Poland • 10 methods

Water & wastewater

ESC GLOBAL Sp. z o.o. is a laboratory accredited by PCA under number AB 1752 (Dołuje, Poland). Its accreditation scope covers 10 test methods in the following areas: Water & wastewater. Test objects include: Water, Deposits (boiler scale). Most frequently used techniques: Spectrophotometric method, Inductively coupled plasma optical emission spectrometry (ICP-OES), High-temperature combustion with IR detection.

At a glance

  • Accreditation number: PCA AB 1752
  • Methods in scope: 10
  • Types of test objects: 2
  • Techniques used: 5
  • City: Dołuje, Poland
Accreditation number
AB 1752
Accreditation body
PCA
Address
LABORATORIUM ANALIZ FIZYKOCHEMICZNYCH, ul. Słoneczny Sad 4F, 72–002 Dołuje
City
Dołuje, Poland

What this laboratory tests (2)

Analytical techniques used (5)

Laboratory locations

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Physicochemical Analyses Laboratory
1 Deposits (boiler scale) Element content
Al (30 – 250000) mg/kg Ba, Pb (10 – 1500) mg/kg Cr, Cu, Mn (10 – 3500) mg/kg Ca (20 – 400 000 ) mg/kg Cd (10 – 200) mg/kg Fe (70 – 650 000) mg/kg K (10 – 35 000) mg/kg Mg (10 – 200 000) mg/kg Na (30 – 400 000) mg/kg Ni (10 – 2500) mg/kg P (20 – 110 000 ) mg/kg S (30 – 150 000) mg/kg Si (30 – 10 000) mg/kg Zn (10 – 10 000) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 22036:2024-07
2 Water Element concentration
Ag, Al, Ba, Cr, Mn, Ni, Pb, Zn: Range (0,1 – 50) mg/l Fe, Mg, P (0,1 – 1000) mg/l Ca (0,2 – 1700) mg/l Cd (0,2 – 50) mg/l Cu (0,1 – 2500) mg/l K (1 – 1000) mg/l Na (1 – 1500) mg/l P (0,1 – 1000) mg/l S (1 – 100 ) mg/l Si (0,2 – 1000 ) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN–EN ISO 11885:2009
3 Water Electrical conductivity
Range 25 – 10 000 μS/cm
Method: conductometric PN–EN 27888:1999
4 Water Total hardness
Range 2,8 – 20 °dH
Spectrophotometric method HACH LCK Nr 327, wydanie 1 z 07/2019
5 Water Chloride concentration
Range 3 – 1000 mg/l
Spectrophotometric method HACH LCK Nr 311, wydanie 3 z 04/2022
6 Water Manganese concentration
Range 0,008 – 0,5 mg/l
Spectrophotometric method HACH LCW Nr 532, wydanie 1 z 03/2020
7 Water Iron concentration
Range 0,35 – 6,0 mg/l
Spectrophotometric method HACH LCK Nr 320, wydanie 2 z 06/2025
8 Water Soluble silica concentration
Range 5 – 100 mg/l
Spectrophotometric method HACH Nr 8185 Wydanie 10 z 10/2023
9 Water Anion concentrations
chlorides (1,0 – 1000) mg/l phosphates (1,0 – 100) mg/l sulfates (1,0 – 500) mg/l nitrates (0,10– 100 mg/l nitrites (0,10 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012
10 Water Total organic carbon concentration (TOC)
Range (2,0 – 1000) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999

Reference standards (10)

HACH LCK Nr 311, wydanie 3 z 04/2022
HACH LCK Nr 320, wydanie 2 z 06/2025
HACH LCK Nr 327, wydanie 1 z 07/2019
HACH LCW Nr 532, wydanie 1 z 03/2020
HACH Nr 8185 Wydanie 10 z 10/2023
PN-EN 1484:1999
PN-EN ISO 10304-1:2009 + AC:2012
PN-EN ISO 22036:2024-07
PN–EN 27888:1999
PN–EN ISO 11885:2009