{"lab":{"_id":"69ad52a3de79e566650fb941","accr_number":"AB 1752","country":"PL","accr_body":"PCA","address":"LABORATORIUM ANALIZ FIZYKOCHEMICZNYCH, ul. Słoneczny Sad 4F, 72–002 Dołuje","categories":["water"],"city":"Dołuje","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"ESC GLOBAL Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1752.pdf"],"scope_summary":"","search_text":"esc global sp. z o.o. laboratorium analiz fizykochemicznych, ul. słoneczny sad 4f, 72–002 dołuje water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:52.408Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:03:18.295Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201752,podmiot.html","fields_of_testing":[{"codes":"C/28; C/32","pl":"Badania chemiczne wody, osadów","en":"Chemical tests of water, sediments"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"6","date":"24.06.2026"},"parse_date":"2026-08-13T08:03:18.295Z","parse_source":"agent-claude-code","map_coord":[53.438149,14.415959],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ANALIZ FIZYKOCHEMICZNYCH","address":"ul. Słoneczny Sad 4F","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka6","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/f75b349ef257799ac00eb637b7f38a8a/AB%201752.pdf","has_en":true,"category_counts":{"water":10},"category_scores":{"water":10},"has_zh":true},"methods":[{"_id":"6a7d7a460636ba417e41b390","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Osady (kamień kotłowy)","methodology":"Zawartość pierwiastków","parameters":[{"name":"Al","range":"(30 – 250000) mg/kg"},{"name":"Ba, Pb","range":"(10 – 1500) mg/kg"},{"name":"Cr, Cu, Mn","range":"(10 – 3500) mg/kg"},{"name":"Ca","range":"(20 – 400 000 ) mg/kg"},{"name":"Cd","range":"(10 – 200) mg/kg"},{"name":"Fe","range":"(70 – 650 000) mg/kg"},{"name":"K","range":"(10 – 35 000) mg/kg"},{"name":"Mg","range":"(10 – 200 000) mg/kg"},{"name":"Na","range":"(30 – 400 000) mg/kg"},{"name":"Ni","range":"(10 – 2500) mg/kg"},{"name":"P","range":"(20 – 110 000 ) mg/kg"},{"name":"S","range":"(30 – 150 000) mg/kg"},{"name":"Si","range":"(30 – 10 000) mg/kg"},{"name":"Zn","range":"(10 – 10 000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nAl (30 – 250000) mg/kg\nBa, Pb (10 – 1500) mg/kg\nCr, Cu, Mn (10 – 3500) mg/kg\nCa (20 – 400 000 ) mg/kg\nCd (10 – 200) mg/kg\nFe (70 – 650 000) mg/kg\nK (10 – 35 000) mg/kg\nMg (10 – 200 000) mg/kg\nNa (30 – 400 000) mg/kg\nNi (10 – 2500) mg/kg\nP (20 – 110 000 ) mg/kg\nS (30 – 150 000) mg/kg\nSi (30 – 10 000) mg/kg\nZn (10 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 22036:2024-07","norm_bases":["PN-EN ISO 22036:2024-07"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady (kamień kotłowy) Zawartość pierwiastków\nZakres:\nAl (30 – 250000) mg/kg\nBa, Pb (10 – 1500) mg/kg\nCr, Cu, Mn (10 – 3500) mg/kg\nCa (20 – 400 000 ) mg/kg\nCd (10 – 200) mg/kg\nFe (70 – 650 000) mg/kg\nK (10 – 35 000) mg/kg\nMg (10 – 200 000) mg/kg\nNa (30 – 400 000) mg/kg\nNi (10 – 2500) mg/kg\nP (20 – 110 000 ) mg/kg\nS (30 – 150 000) mg/kg\nSi (30 – 10 000) mg/kg\nZn (10 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 22036:2024-07 Osady (kamien kotlowy) Zawartosc pierwiastkow\nZakres:\nAl (30 – 250000) mg/kg\nBa, Pb (10 – 1500) mg/kg\nCr, Cu, Mn (10 – 3500) mg/kg\nCa (20 – 400 000 ) mg/kg\nCd (10 – 200) mg/kg\nFe (70 – 650 000) mg/kg\nK (10 – 35 000) mg/kg\nMg (10 – 200 000) mg/kg\nNa (30 – 400 000) mg/kg\nNi (10 – 2500) mg/kg\nP (20 – 110 000 ) mg/kg\nS (30 – 150 000) mg/kg\nSi (30 – 10 000) mg/kg\nZn (10 – 10 000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 22036:2024-07","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Element content","parameters_en":[{"name":"Al","range":"(30 – 250000) mg/kg"},{"name":"Ba, Pb","range":"(10 – 1500) mg/kg"},{"name":"Cr, Cu, Mn","range":"(10 – 3500) mg/kg"},{"name":"Ca","range":"(20 – 400 000 ) mg/kg"},{"name":"Cd","range":"(10 – 200) mg/kg"},{"name":"Fe","range":"(70 – 650 000) mg/kg"},{"name":"K","range":"(10 – 35 000) mg/kg"},{"name":"Mg","range":"(10 – 200 000) mg/kg"},{"name":"Na","range":"(30 – 400 000) mg/kg"},{"name":"Ni","range":"(10 – 2500) mg/kg"},{"name":"P","range":"(20 – 110 000 ) mg/kg"},{"name":"S","range":"(30 – 150 000) mg/kg"},{"name":"Si","range":"(30 – 10 000) mg/kg"},{"name":"Zn","range":"(10 – 10 000) mg/kg"}],"search_en":"Deposits (boiler scale) Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Physicochemical Analyses Laboratory Al Ba, Pb Cr, Cu, Mn Ca Cd Fe K Mg Na Ni P S Si Zn PN-EN ISO 22036:2024-07","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Deposits (boiler scale)","methodology_zh":"元素含量","parameters_zh":[{"name":"Al","range":"(30 – 250000) mg/kg"},{"name":"Ba, Pb","range":"(10 – 1500) mg/kg"},{"name":"Cr, Cu, Mn","range":"(10 – 3500) mg/kg"},{"name":"Ca","range":"(20 – 400 000 ) mg/kg"},{"name":"Cd","range":"(10 – 200) mg/kg"},{"name":"Fe","range":"(70 – 650 000) mg/kg"},{"name":"K","range":"(10 – 35 000) mg/kg"},{"name":"Mg","range":"(10 – 200 000) mg/kg"},{"name":"Na","range":"(30 – 400 000) mg/kg"},{"name":"Ni","range":"(10 – 2500) mg/kg"},{"name":"P","range":"(20 – 110 000 ) mg/kg"},{"name":"S","range":"(30 – 150 000) mg/kg"},{"name":"Si","range":"(30 – 10 000) mg/kg"},{"name":"Zn","range":"(10 – 10 000) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 理化分析实验室 Al Ca Cd Fe K Mg Na Ni P S Si Zn PN-EN ISO 22036:2024-07","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b391","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Ag, Al, Ba, Cr, Mn, Ni, Pb, Zn:"},{"name":"Zakres","range":"(0,1 – 50) mg/l"},{"name":"Fe, Mg, P","range":"(0,1 – 1000) mg/l"},{"name":"Ca","range":"(0,2 – 1700) mg/l"},{"name":"Cd","range":"(0,2 – 50) mg/l"},{"name":"Cu","range":"(0,1 – 2500) mg/l"},{"name":"K","range":"(1 – 1000) mg/l"},{"name":"Na","range":"(1 – 1500) mg/l"},{"name":"P","range":"(0,1 – 1000) mg/l"},{"name":"S","range":"(1 – 100 ) mg/l"},{"name":"Si","range":"(0,2 – 1000 ) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAg, Al, Ba, Cr, Mn, Ni, Pb, Zn:\nZakres (0,1 – 50) mg/l\nFe, Mg, P (0,1 – 1000) mg/l\nCa (0,2 – 1700) mg/l\nCd (0,2 – 50) mg/l\nCu (0,1 – 2500) mg/l\nK (1 – 1000) mg/l\nNa (1 – 1500) mg/l\nP (0,1 – 1000) mg/l\nS (1 – 100 ) mg/l\nSi (0,2 – 1000 ) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN–EN ISO 11885:2009","norm_bases":["PN–EN ISO 11885:2009"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nZakres:\nAg, Al, Ba, Cr, Mn, Ni, Pb, Zn:\nZakres (0,1 – 50) mg/l\nFe, Mg, P (0,1 – 1000) mg/l\nCa (0,2 – 1700) mg/l\nCd (0,2 – 50) mg/l\nCu (0,1 – 2500) mg/l\nK (1 – 1000) mg/l\nNa (1 – 1500) mg/l\nP (0,1 – 1000) mg/l\nS (1 – 100 ) mg/l\nSi (0,2 – 1000 ) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN–EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\nAg, Al, Ba, Cr, Mn, Ni, Pb, Zn:\nZakres (0,1 – 50) mg/l\nFe, Mg, P (0,1 – 1000) mg/l\nCa (0,2 – 1700) mg/l\nCd (0,2 – 50) mg/l\nCu (0,1 – 2500) mg/l\nK (1 – 1000) mg/l\nNa (1 – 1500) mg/l\nP (0,1 – 1000) mg/l\nS (1 – 100 ) mg/l\nSi (0,2 – 1000 ) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN–EN ISO 11885:2009","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"Ag, Al, Ba, Cr, Mn, Ni, Pb, Zn:"},{"name":"Range","range":"(0,1 – 50) mg/l"},{"name":"Fe, Mg, P","range":"(0,1 – 1000) mg/l"},{"name":"Ca","range":"(0,2 – 1700) mg/l"},{"name":"Cd","range":"(0,2 – 50) mg/l"},{"name":"Cu","range":"(0,1 – 2500) mg/l"},{"name":"K","range":"(1 – 1000) mg/l"},{"name":"Na","range":"(1 – 1500) mg/l"},{"name":"P","range":"(0,1 – 1000) mg/l"},{"name":"S","range":"(1 – 100 ) mg/l"},{"name":"Si","range":"(0,2 – 1000 ) mg/l"}],"search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Physicochemical Analyses Laboratory Ag, Al, Ba, Cr, Mn, Ni, Pb, Zn: Range Fe, Mg, P Ca Cd Cu K Na P S Si PN–EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","methodology_zh":"元素浓度","parameters_zh":[{"name":"Ag, Al, Ba, Cr, Mn, Ni, Pb, Zn:"},{"name":"范围","range":"(0,1 – 50) mg/l"},{"name":"Fe, Mg, P","range":"(0,1 – 1000) mg/l"},{"name":"Ca","range":"(0,2 – 1700) mg/l"},{"name":"Cd","range":"(0,2 – 50) mg/l"},{"name":"Cu","range":"(0,1 – 2500) mg/l"},{"name":"K","range":"(1 – 1000) mg/l"},{"name":"Na","range":"(1 – 1500) mg/l"},{"name":"P","range":"(0,1 – 1000) mg/l"},{"name":"S","range":"(1 – 100 ) mg/l"},{"name":"Si","range":"(0,2 – 1000 ) mg/l"}],"search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 理化分析实验室 范围 Ca Cd Cu K Na P S Si PN–EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b392","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"25 – 10 000 μS/cm"}],"technique":"Metoda: konduktometryczna","techniques":["Metoda: konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 25 – 10 000 μS/cm\nMetoda: konduktometryczna","reference":"PN–EN 27888:1999","norm_bases":["PN–EN 27888:1999"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres 25 – 10 000 μS/cm\nMetoda: konduktometryczna PN–EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres 25 – 10 000 μS/cm\nMetoda: konduktometryczna PN–EN 27888:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"25 – 10 000 μS/cm"}],"search_en":"Water Electrical conductivity Method: conductometric Physicochemical Analyses Laboratory Range PN–EN 27888:1999","technique_en":"Method: conductometric","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"25 – 10 000 μS/cm"}],"search_zh":"水 电导率 理化分析实验室 范围 PN–EN 27888:1999","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b393","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"2,8 – 20 °dH"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Twardość ogólna\nZakres 2,8 – 20 °dH\nMetoda spektrofotometryczna","reference":"HACH LCK Nr 327, wydanie 1 z 07/2019","norm_bases":["HACH LCK Nr 327, wydanie 1 z 07/2019"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Twardość ogólna\nZakres 2,8 – 20 °dH\nMetoda spektrofotometryczna HACH LCK Nr 327, wydanie 1 z 07/2019 Woda Twardosc ogolna\nZakres 2,8 – 20 °dH\nMetoda spektrofotometryczna HACH LCK Nr 327, wydanie 1 z 07/2019","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"2,8 – 20 °dH"}],"search_en":"Water Total hardness Spectrophotometric method Physicochemical Analyses Laboratory Range HACH LCK Nr 327, wydanie 1 z 07/2019","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"2,8 – 20 °dH"}],"search_zh":"水 总硬度 分光光度法 理化分析实验室 范围 HACH LCK Nr 327, wydanie 1 z 07/2019","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"总硬度","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b394","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"3 – 1000 mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres 3 – 1000 mg/l\nMetoda spektrofotometryczna","reference":"HACH LCK Nr 311, wydanie 3 z 04/2022","norm_bases":["HACH LCK Nr 311, wydanie 3 z 04/2022"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chlorków\nZakres 3 – 1000 mg/l\nMetoda spektrofotometryczna HACH LCK Nr 311, wydanie 3 z 04/2022 Woda Stezenie chlorkow\nZakres 3 – 1000 mg/l\nMetoda spektrofotometryczna HACH LCK Nr 311, wydanie 3 z 04/2022","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"3 – 1000 mg/l"}],"search_en":"Water Chloride concentration Spectrophotometric method Physicochemical Analyses Laboratory Range HACH LCK Nr 311, wydanie 3 z 04/2022","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"3 – 1000 mg/l"}],"search_zh":"水 氯化物浓度 分光光度法 理化分析实验室 范围 HACH LCK Nr 311, wydanie 3 z 04/2022","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b395","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"0,008 – 0,5 mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres 0,008 – 0,5 mg/l\nMetoda spektrofotometryczna","reference":"HACH LCW Nr 532, wydanie 1 z 03/2020","norm_bases":["HACH LCW Nr 532, wydanie 1 z 03/2020"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres 0,008 – 0,5 mg/l\nMetoda spektrofotometryczna HACH LCW Nr 532, wydanie 1 z 03/2020 Woda Stezenie manganu\nZakres 0,008 – 0,5 mg/l\nMetoda spektrofotometryczna HACH LCW Nr 532, wydanie 1 z 03/2020","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"0,008 – 0,5 mg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Physicochemical Analyses Laboratory Range HACH LCW Nr 532, wydanie 1 z 03/2020","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"0,008 – 0,5 mg/l"}],"search_zh":"水 锰浓度 分光光度法 理化分析实验室 范围 HACH LCW Nr 532, wydanie 1 z 03/2020","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b396","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"0,35 – 6,0 mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres 0,35 – 6,0 mg/l\nMetoda spektrofotometryczna","reference":"HACH LCK Nr 320, wydanie 2 z 06/2025","norm_bases":["HACH LCK Nr 320, wydanie 2 z 06/2025"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza\nZakres 0,35 – 6,0 mg/l\nMetoda spektrofotometryczna HACH LCK Nr 320, wydanie 2 z 06/2025 Woda Stezenie zelaza\nZakres 0,35 – 6,0 mg/l\nMetoda spektrofotometryczna HACH LCK Nr 320, wydanie 2 z 06/2025","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"0,35 – 6,0 mg/l"}],"search_en":"Water Iron concentration Spectrophotometric method Physicochemical Analyses Laboratory Range HACH LCK Nr 320, wydanie 2 z 06/2025","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"0,35 – 6,0 mg/l"}],"search_zh":"水 铁浓度 分光光度法 理化分析实验室 范围 HACH LCK Nr 320, wydanie 2 z 06/2025","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b397","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie krzemionki rozpuszczalnej","parameters":[{"name":"Zakres","range":"5 – 100 mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie krzemionki rozpuszczalnej\nZakres 5 – 100 mg/l\nMetoda spektrofotometryczna","reference":"HACH Nr 8185 Wydanie 10 z 10/2023","norm_bases":["HACH Nr 8185 Wydanie 10 z 10/2023"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie krzemionki rozpuszczalnej\nZakres 5 – 100 mg/l\nMetoda spektrofotometryczna HACH Nr 8185 Wydanie 10 z 10/2023 Woda Stezenie krzemionki rozpuszczalnej\nZakres 5 – 100 mg/l\nMetoda spektrofotometryczna HACH Nr 8185 Wydanie 10 z 10/2023","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Soluble silica concentration","parameters_en":[{"name":"Range","range":"5 – 100 mg/l"}],"search_en":"Water Soluble silica concentration Spectrophotometric method Physicochemical Analyses Laboratory Range HACH Nr 8185 Wydanie 10 z 10/2023","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"5 – 100 mg/l"}],"search_zh":"水 分光光度法 理化分析实验室 范围 HACH Nr 8185 Wydanie 10 z 10/2023","technique_zh":"分光光度法","test_object_zh":"水","lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b398","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(1,0 – 1000) mg/l"},{"name":"fosforany","range":"(1,0 – 100) mg/l"},{"name":"siarczany","range":"(1,0 – 500) mg/l"},{"name":"azotany (0,10– 100 mg/l azotyny","range":"(0,10 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nfosforany (1,0 – 100) mg/l\nsiarczany (1,0 – 500) mg/l\nazotany (0,10– 100 mg/l azotyny (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 + AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 + AC:2012"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie anionów\nZakres:\nchlorki (1,0 – 1000) mg/l\nfosforany (1,0 – 100) mg/l\nsiarczany (1,0 – 500) mg/l\nazotany (0,10– 100 mg/l azotyny (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012 Woda Stezenie anionow\nZakres:\nchlorki (1,0 – 1000) mg/l\nfosforany (1,0 – 100) mg/l\nsiarczany (1,0 – 500) mg/l\nazotany (0,10– 100 mg/l azotyny (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 + AC:2012","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(1,0 – 1000) mg/l"},{"name":"phosphates","range":"(1,0 – 100) mg/l"},{"name":"sulfates","range":"(1,0 – 500) mg/l"},{"name":"nitrates (0,10– 100 mg/l nitrites","range":"(0,10 – 10) mg/l"}],"search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) Physicochemical Analyses Laboratory chlorides phosphates sulfates nitrates (0,10– 100 mg/l nitrites PN-EN ISO 10304-1:2009 + AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 理化分析实验室 氯化物 磷酸盐 硫酸盐 PN-EN ISO 10304-1:2009 + AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"磷酸盐","range":"(1,0 – 100) mg/l"},{"name":"硫酸盐","range":"(1,0 – 500) mg/l"},{"name":"azotany (0,10– 100 mg/l azotyny","range":"(0,10 – 10) mg/l"}],"lab_section_zh":"理化分析实验室"},{"_id":"6a7d7a460636ba417e41b399","lab_id":"69ad52a3de79e566650fb941","country":"PL","accr_number":"AB 1752","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Analiz Fizykochemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie ogólnego węgla organicznego (OWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda Stezenie ogolnego wegla organicznego (OWO)\nZakres (2,0 – 1000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Physicochemical Analyses Laboratory","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water Total organic carbon concentration (TOC) High-temperature combustion with IR detection Physicochemical Analyses Laboratory Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水 总有机碳浓度（TOC） 高温燃烧红外检测法 理化分析实验室 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水","methodology_zh":"总有机碳浓度（TOC）","lab_section_zh":"理化分析实验室"}],"has_pdf":true}