🇵🇱 CELMA INDUKTA SA PL

PCA AB 1747 • Cieszyn, Poland • 4 methods

Other

CELMA INDUKTA SA is a laboratory accredited by PCA under number AB 1747 (Cieszyn, Poland). Its accreditation scope covers 4 test methods in the following areas: Other. Test objects include: Electric motor, asynchronous (induction), with a rated power of up…. Most frequently used techniques: Summation of losses method (indirect method).

At a glance

  • Accreditation number: PCA AB 1747
  • Methods in scope: 4
  • Types of test objects: 1
  • Techniques used: 1
  • City: Cieszyn, Poland
Accreditation number
AB 1747
Accreditation body
PCA
Address
ul. 3 Maja 19, 43-400 Cieszyn
City
Cieszyn, Poland

What this laboratory tests (1)

Analytical techniques used (1)

Laboratory locations

Certificate information

Issue date
04.08.2026
Issue no.
5

Accreditation scope — test methods (4)

No. Test object Methodology / Parameters Technique Reference document
CELMA INDUKTA SA; Testing Laboratory
1 Electric motor, asynchronous (induction), with a rated power of up to 500 kW Efficiency determination Summation of losses method (indirect method) PN-EN 60034-1:2011 | EN 60034-1:2010 | IEC 60034-1:2010 | IEC 60034-1:2022-02 | PN-EN 60034-2-1:2015-01 p. 6.1.3 | EN 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2024-03 p. 6.1.3 | PN-EN 60034-30-1:2014-11 | EN 60034-30-1:2014 | IEC 60034-30-1:2014 | IEC 60034-30-1:2025-12 | SASO 2893:2018
2 Electric motor, asynchronous (induction), with a rated power of up to 500 kW Rated load test, heating run PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1 | EN 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2024-03 p. 6.1.3.2.1
3 Electric motor, asynchronous (induction), with a rated power of up to 500 kW Measurement of load characteristics PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6
4 Electric motor, asynchronous (induction), with a rated power of up to 500 kW Measurement of no-load characteristics and no-load losses PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5 | EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5

Reference standards (25)

EN 60034-1:2010
EN 60034-2-1:2014 p. 6.1.3
EN 60034-2-1:2014 p. 6.1.3.2.1
EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6
EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5
EN 60034-30-1:2014
IEC 60034-1:2010
IEC 60034-1:2022-02
IEC 60034-2-1:2014 p. 6.1.3
IEC 60034-2-1:2014 p. 6.1.3.2.1
IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6
IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5
IEC 60034-2-1:2024-03 p. 6.1.3
IEC 60034-2-1:2024-03 p. 6.1.3.2.1
IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5
IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6
IEC 60034-30-1:2014
IEC 60034-30-1:2025-12
PN-EN 60034-1:2011
PN-EN 60034-2-1:2015-01 p. 6.1.3
PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1
PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6
PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5
PN-EN 60034-30-1:2014-11
SASO 2893:2018

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201747