{"lab":{"_id":"69ad52a3de79e566650fb937","accr_number":"AB 1747","country":"PL","accr_body":"PCA","address":"ul. 3 Maja 19, 43-400 Cieszyn","categories":["other"],"city":"Cieszyn","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"CELMA INDUKTA SA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1747.pdf"],"scope_summary":"","search_text":"celma indukta sa ul. 3 maja 19, 43-400 cieszyn pharma electronics other metrology","status":"active","updated_at":"2026-03-08T14:50:52.039Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:23:08.034Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201747,podmiot.html","fields_of_testing":[{"codes":"E/6","pl":"Badania elektryczne wyrobów i wyposażenia elektrycznego","en":"Electric tests of electrical products and equipment"}],"issue":{"no":"5","date":"04.08.2026"},"parse_date":"2026-08-17T11:23:08.034Z","parse_source":"agent-claude-code","map_coord":[49.743023,18.630898],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Badawcze","address":"ul. 3 Maja 19, 43-400 Cieszyn","city":"Cieszyn","postal":"43-400"},{"name":"CELMA INDUKTA SA; Laboratorium Badawcze","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/e46bf8ac2a3ae040d0dd05caa1f36ec7/AB%201747.pdf","category_counts":{"other":4},"category_scores":{"other":4}},"methods":[{"_id":"6a82ef1c884ede9a1b2c4bff","lab_id":"69ad52a3de79e566650fb937","country":"PL","accr_number":"AB 1747","accr_body":"PCA","test_object":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW","methodology":"Wyznaczanie sprawności / Efficiency determination","parameters":[],"technique":"Metoda strat poszczególnych (metoda pośrednia) / summation of losses method, (indirect method)","techniques":["Metoda strat poszczególnych (metoda pośrednia) / summation of losses method, (indirect method)"],"computed":[],"activity":"Wyznaczanie sprawności / Efficiency determination\nMetoda strat poszczególnych (metoda pośrednia) / summation of losses method, (indirect method)","reference":"PN-EN 60034-1:2011 | EN 60034-1:2010 | IEC 60034-1:2010 | IEC 60034-1:2022-02 | PN-EN 60034-2-1:2015-01 p. 6.1.3 | EN 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2024-03 p. 6.1.3 | PN-EN 60034-30-1:2014-11 | EN 60034-30-1:2014 | IEC 60034-30-1:2014 | IEC 60034-30-1:2025-12 | SASO 2893:2018","norm_bases":["PN-EN 60034-1:2011","EN 60034-1:2010","IEC 60034-1:2010","IEC 60034-1:2022-02","PN-EN 60034-2-1:2015-01 p. 6.1.3","EN 60034-2-1:2014 p. 6.1.3","IEC 60034-2-1:2014 p. 6.1.3","IEC 60034-2-1:2024-03 p. 6.1.3","PN-EN 60034-30-1:2014-11","EN 60034-30-1:2014","IEC 60034-30-1:2014","IEC 60034-30-1:2025-12","SASO 2893:2018"],"lab_section":"CELMA INDUKTA SA; Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Wyznaczanie sprawności / Efficiency determination\nMetoda strat poszczególnych (metoda pośrednia) / summation of losses method, (indirect method) PN-EN 60034-1:2011 | EN 60034-1:2010 | IEC 60034-1:2010 | IEC 60034-1:2022-02 | PN-EN 60034-2-1:2015-01 p. 6.1.3 | EN 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2024-03 p. 6.1.3 | PN-EN 60034-30-1:2014-11 | EN 60034-30-1:2014 | IEC 60034-30-1:2014 | IEC 60034-30-1:2025-12 | SASO 2893:2018 Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Wyznaczanie sprawnosci / Efficiency determination\nMetoda strat poszczegolnych (metoda posrednia) / summation of losses method, (indirect method) PN-EN 60034-1:2011 | EN 60034-1:2010 | IEC 60034-1:2010 | IEC 60034-1:2022-02 | PN-EN 60034-2-1:2015-01 p. 6.1.3 | EN 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2014 p. 6.1.3 | IEC 60034-2-1:2024-03 p. 6.1.3 | PN-EN 60034-30-1:2014-11 | EN 60034-30-1:2014 | IEC 60034-30-1:2014 | IEC 60034-30-1:2025-12 | SASO 2893:2018","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a82ef1c884ede9a1b2c4c00","lab_id":"69ad52a3de79e566650fb937","country":"PL","accr_number":"AB 1747","accr_body":"PCA","test_object":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW","methodology":"Próba nagrzewania / Rated load test, heating run","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Próba nagrzewania / Rated load test, heating run","reference":"PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1 | EN 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2024-03 p. 6.1.3.2.1","norm_bases":["PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1","EN 60034-2-1:2014 p. 6.1.3.2.1","IEC 60034-2-1:2014 p. 6.1.3.2.1","IEC 60034-2-1:2024-03 p. 6.1.3.2.1"],"lab_section":"CELMA INDUKTA SA; Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Próba nagrzewania / Rated load test, heating run PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1 | EN 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2024-03 p. 6.1.3.2.1 Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Proba nagrzewania / Rated load test, heating run PN-EN 60034-2-1:2015-01 p. 6.1.3.2.1 | EN 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2014 p. 6.1.3.2.1 | IEC 60034-2-1:2024-03 p. 6.1.3.2.1","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a82ef1c884ede9a1b2c4c01","lab_id":"69ad52a3de79e566650fb937","country":"PL","accr_number":"AB 1747","accr_body":"PCA","test_object":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW","methodology":"Pomiar charakterystyk obciążenia / Measurement of load characteristics","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar charakterystyk obciążenia / Measurement of load characteristics","reference":"PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6","norm_bases":["PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6","EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6","IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6","IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6"],"lab_section":"CELMA INDUKTA SA; Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Pomiar charakterystyk obciążenia / Measurement of load characteristics PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Pomiar charakterystyk obciazenia / Measurement of load characteristics PN-EN 60034-2-1:2015-01 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | EN 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2014 p. 6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6 | IEC 60034-2-1:2024-03 p.6.1.3.2.2, 6.1.3.2.3, 6.1.3.2.6","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a82ef1c884ede9a1b2c4c02","lab_id":"69ad52a3de79e566650fb937","country":"PL","accr_number":"AB 1747","accr_body":"PCA","test_object":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW","methodology":"Pomiar charakterystyki biegu jałowego i strat biegu jałowego / Measurement of no-load characteristics and no-load losses","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pomiar charakterystyki biegu jałowego i strat biegu jałowego / Measurement of no-load characteristics and no-load losses","reference":"PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5 | EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5","norm_bases":["PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5","EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5","IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5","IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5"],"lab_section":"CELMA INDUKTA SA; Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Pomiar charakterystyki biegu jałowego i strat biegu jałowego / Measurement of no-load characteristics and no-load losses PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5 | EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5 Silnik elektryczny, asynchroniczny (indukcyjny) o mocy znamionowej do 500 kW / Electric motor, asynchronous (induction) with a rated power of up to 500 kW Pomiar charakterystyki biegu jalowego i strat biegu jalowego / Measurement of no-load characteristics and no-load losses PN-EN 60034-2-1:2015-01 p. 6.1.3.2.4, 6.1.3.2.5 | EN 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2014 p. 6.1.3.2.4, 6.1.3.2.5 | IEC 60034-2-1:2024-03 p. 6.1.3.2.4, 6.1.3.2.5","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}