🇵🇱 eSMOKING INSTITUTE Sp. z o.o. PL
Electronics & EMCWater & wastewater
eSMOKING INSTITUTE Sp. z o.o. is a laboratory accredited by PCA under number AB 1745 (Poznań, Poland). Its accreditation scope covers 28 test methods in the following areas: Electronics & EMC, Water & wastewater. Test objects include: Tobacco products: nicotine liquid for electronic cigarettes, Tobacco products: aerosol vaporised from an e-cigarette, Tobacco products: aerosol deposited on glass filters, Tobacco products: aerosol extracted from glass filters. Most frequently used techniques: Gravimetric method, Gas chromatography with flame ionization detection (GC-FID), Gas chromatography with mass spectrometry detection (GC-MS).
At a glance
- Accreditation number: PCA AB 1745
- Methods in scope: 28
- Types of test objects: 7
- Techniques used: 10
- City: Poznań, Poland
- Valid until: 06.04.2028
- Accreditation number
- AB 1745
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Rubież 46, 61-612 Poznań
- City
- Poznań, Poland
- Valid until
- 06.04.2028
What this laboratory tests (7)
- Tobacco products: nicotine liquid for electronic cigarettes — 8 methods
- Tobacco products: aerosol vaporised from an e-cigarette — 6 methods
- Tobacco products: aerosol deposited on glass filters — 5 methods
- Tobacco products: aerosol extracted from glass filters — 5 methods
- Chemical products: flavourings — 2 methods
- Tobacco products: aerosol deposited on quartz filters — 1 method
- Tobacco products: aerosol extracted from quartz filters — 1 method
Analytical techniques used (10)
- Gravimetric method — 12 methods
- Gas chromatography with flame ionization detection (GC-FID) — 5 methods
- Gas chromatography with mass spectrometry detection (GC-MS) — 2 methods
- Modified continuously closed cup method (MCCCFP) — 2 methods
- Oscillation method — 2 methods
- Gas chromatography with thermal conductivity detection (GC-TCD) — 1 method
- High-performance liquid chromatography with photodiode array detection (HPLC-DAD) — 1 method
- Inductively coupled plasma mass spectrometry (ICP-MS) — 1 method
- Potentiometric method — 1 method
- Volumetric titration method (according to Karl Fischer) — 1 method
Laboratory locations
- LABORATORIUM BADAWCZE — ul. Rubież 46
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Testing Laboratory | |||||
| 1 | Tobacco products: nicotine liquid for electronic cigarettes | Nicotine content Range (1 – 40) mg/ml |
Gas chromatography with flame ionization detection (GC-FID) | PB-01 wydanie 5 z dnia 13.01.2023 r. | |
| 2 | Tobacco products: nicotine liquid for electronic cigarettes | Nicotine content Range (0,05 – 1) mg/ml |
Gas chromatography with flame ionization detection (GC-FID) | PB-02 wydanie 4 z dnia 13.01.2023 r. | |
| 3 | Tobacco products: nicotine liquid for electronic cigarettes | Concentration of organic compounds nicotine (2,00 – 40,0) mg/ml glycerine (100 – 1000) mg/ml propylene glycol (100 – 1000) mg/ml Concentration of organic compounds in mg/g (calculated) |
Gas chromatography with flame ionization detection (GC-FID) | ISO 20714:2019 | |
| 4 | Tobacco products: nicotine liquid for electronic cigarettes | Benzoic acid concentration Range (1 – 20) mg/ml Benzoic acid concentration in mg/g (calculated) |
High-performance liquid chromatography with photodiode array detection (HPLC-DAD) | PB-26 wydanie 2 z dnia 13.01.2023 r. | |
| 5 | Tobacco products: nicotine liquid for electronic cigarettes | pH Range 2,0 – 12,0 |
Potentiometric method | PB-27 wydanie 4 z dnia 13.01.2026 r. | |
| 6 | Tobacco products: nicotine liquid for electronic cigarettes | Density Range (0,9379 – 1,2845) g/cm3 |
Oscillation method | PB-28 wydanie 3 z dnia 21.07.2023 r. | |
| 7 | Tobacco products: nicotine liquid for electronic cigarettes | Flash point Range (43 – 184) °C |
Modified continuously closed cup method (MCCCFP) | PB-29 wydanie 2 z dnia 13.01.2023 r. | |
| 8 | Tobacco products: nicotine liquid for electronic cigarettes | Water content Range (0,30 – 12,0 ) % m/m |
Volumetric titration method (according to Karl Fischer) | PB-32 wydanie 1 z dnia 18.04.2023 r. | |
| 9 | Chemical products: flavourings | Density Range (0,9379 – 1,2845) g/cm3 |
Oscillation method | PB-28 wydanie 3 z dnia 21.07.2023 r. | |
| 10 | Chemical products: flavourings | Flash point Range (43 – 184) °C |
Modified continuously closed cup method (MCCCFP) | PB-29 wydanie 2 z dnia 13.01.2023 r. | |
| 11 | Tobacco products: aerosol extracted from glass filters | Water concentration Range (0,25 – 5) mg/ml Water content in mg/number of puffs (calculated) |
Gas chromatography with thermal conductivity detection (GC-TCD) | PB-03 wydanie 6 z dnia 13.01.2023 r. | |
| 12 | Tobacco products: aerosol deposited on glass filters | Aerosol mass (ACM) Range (23,7 – 380,3) mg |
Gravimetric method | PB-03 wydanie 6 z dnia 13.01.2023 r. | |
| 13 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (24,9 – 415,7) mg |
Gravimetric method | PB-03 wydanie 6 z dnia 13.01.2023 r. | |
| 14 | Tobacco products: aerosol extracted from glass filters | Propylene oxide concentration Range (0,05 – 2) µg/ml Zawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń) |
Gas chromatography with mass spectrometry detection (GC-MS) | PB-05 wydanie 5 z dnia 13.01.2023 r. | |
| 15 | Tobacco products: aerosol deposited on glass filters | Aerosol mass (ACM) Range (20,7 – 370,8) mg |
Gravimetric method | PB-05 wydanie 5 z dnia 13.01.2023 r. | |
| 16 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (22,0 – 407,1) mg |
Gravimetric method | PB-05 wydanie 5 z dnia 13.01.2023 r. | |
| 17 | Tobacco products: aerosol extracted from glass filters | Concentration of organic compounds formaldehyde (0,1 – 10) µg/ml acetone (0,1 – 10) µg/ml 2-butanon (0,1 – 10) µg/ml diacetyl (0,1 – 10) µg/ml glyoxal (0,1 – 10) µg/ml acetaldehyde (0,1 – 10) µg/ml propionaldehyde (0,1 – 10) µg/ml acrolein (0,1 – 10) µg/ml butyraldehyde (0,1 – 10) µg/ml crotonaldehyde (0,1 – 10) µg/ml methylglyoxal (0,1 – 10) µg/ml Zawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń) |
Gas chromatography with mass spectrometry detection (GC-MS) | PB-06 wydanie 4 z dnia 13.01.2023 r. | |
| 18 | Tobacco products: aerosol deposited on glass filters | Aerosol mass (ACM) Range (20,7 – 370,8) mg |
Gravimetric method | PB-06 wydanie 4 z dnia 13.01.2023 r. | |
| 19 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (22,0 – 407,1) mg |
Gravimetric method | PB-06 wydanie 4 z dnia 13.01.2023 r. | |
| 20 | Tobacco products: aerosol extracted from quartz filters | Element concentration silver (5,0 – 20) µg/l aluminium (5,0 – 20) µg/l gold (5,0 – 20) µg/l arsenic (0,5 – 20) µg/l beryllium (0,5 – 20) µg/l cadmium (0,5 – 20) µg/l cobalt (0,5 – 20) µg/l chromium (0,5 – 20) µg/l copper (3,0 – 20) µg/l iron (1,0 – 20) µg/l manganese (0,5 – 20) µg/l molybdenum (0,5 – 20) µg/l nickel (0,5 – 20) µg/l lead (0,5 – 20) µg/l selenium (0,5 – 20) µg/l tin (0,5 – 20) µg/l titanium (0,5 – 20) µg/l tungsten (0,5 – 20) µg/l zinc (3,0 – 20) µg/l zirconium (5,0 – 20) µg/l Content of elements in ng/number of puffs (calculated) |
Inductively coupled plasma mass spectrometry (ICP-MS) | PB-12 wydanie 7 z dnia 13.01.2023 r. | |
| 21 | Tobacco products: aerosol deposited on quartz filters | Aerosol mass (ACM) Range (23,6 – 407,4) mg |
Gravimetric method | PB-12 wydanie 7 z dnia 13.01.2023 r. | |
| 22 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (24,6 – 494,3) mg |
Gravimetric method | PB-12 wydanie 7 z dnia 13.01.2023 r. | |
| 23 | Tobacco products: aerosol extracted from glass filters | Concentration of organic compounds nicotine (0,01 – 0,4) mg/ml menthol (0,01 – 0,4) mg/ml propylene glycol (0,5 – 15) mg/ml glycerine (0,5 – 15) mg/ml Content of organic compounds in mg/number of puffs (calculated) |
Gas chromatography with flame ionization detection (GC-FID) | PB-15 wydanie 4 z dnia 13.01.2023 r. | |
| 24 | Tobacco products: aerosol deposited on glass filters | Aerosol mass (ACM) Range (23,7 – 380,3) mg |
Gravimetric method | PB-15 wydanie 4 z dnia 13.01.2023 r. | |
| 25 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (24,9 – 415,7) mg |
Gravimetric method | PB-15 wydanie 4 z dnia 13.01.2023 r. | |
| 26 | Tobacco products: aerosol extracted from glass filters | Glycidol concentration Range (0,2 – 5) µg/ml Zawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń) |
Gas chromatography with flame ionization detection (GC-FID) | PB-23 wydanie 4 z dnia 13.01.2023 r. | |
| 27 | Tobacco products: aerosol deposited on glass filters | Aerosol mass (ACM) Range (20,7 – 370,8) mg |
Gravimetric method | PB-23 wydanie 4 z dnia 13.01.2023 r. | |
| 28 | Tobacco products: aerosol vaporised from an e-cigarette | Aerosol mass (DML) Range (22,0 – 407,1) mg |
Gravimetric method | PB-23 wydanie 4 z dnia 13.01.2023 r. | |
Reference standards (14)
ISO 20714:2019
PB-01 wydanie 5 z dnia 13.01.2023 r.
PB-02 wydanie 4 z dnia 13.01.2023 r.
PB-03 wydanie 6 z dnia 13.01.2023 r.
PB-05 wydanie 5 z dnia 13.01.2023 r.
PB-06 wydanie 4 z dnia 13.01.2023 r.
PB-12 wydanie 7 z dnia 13.01.2023 r.
PB-15 wydanie 4 z dnia 13.01.2023 r.
PB-23 wydanie 4 z dnia 13.01.2023 r.
PB-26 wydanie 2 z dnia 13.01.2023 r.
PB-27 wydanie 4 z dnia 13.01.2026 r.
PB-28 wydanie 3 z dnia 21.07.2023 r.
PB-29 wydanie 2 z dnia 13.01.2023 r.
PB-32 wydanie 1 z dnia 18.04.2023 r.