{"lab":{"_id":"69ad52a3de79e566650fb933","accr_number":"AB 1745","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Rubież 46, 61-612 Poznań","categories":["electronics","water"],"city":"Poznań","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"eSMOKING INSTITUTE Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1745.pdf"],"scope_summary":"","search_text":"esmoking institute sp. z o.o. laboratorium badawcze, ul. rubież 46, 61-612 poznań other electronics pharma water automotive materials","status":"active","updated_at":"2026-03-08T14:50:51.940Z","valid_from":"","valid_until":"06.04.2028","website":"","parsed_at":"2026-08-17T11:22:42.348Z","email_confidence":"high","email_mx":true,"email_source":"https://www.esmokinginstitute.com/kontakt/","fields_of_testing":[{"codes":"C/24","pl":"Badania chemiczne wyrobów tytoniowych","en":"Chemical tests of tobacco products"},{"codes":"N/4; N/24","pl":"Badania właściwości fizycznych wyrobów chemicznych, wyrobów tytoniowych","en":"Tests of physical properties of chemical products, tobacco products"}],"issue":{"no":"6","date":"07.05.2026"},"parse_date":"2026-08-17T11:22:42.348Z","parse_source":"agent-claude-code","map_coord":[52.455315,16.955504],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADAWCZE","address":"ul. Rubież 46","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/a9cc78274de9d8655aadf6da10576c4a/AB%201745.pdf","has_en":true,"category_counts":{"other":12,"electronics":8,"water":8,"materials":1},"category_scores":{"other":4.97,"electronics":2.21,"water":2.21,"materials":0.03},"has_zh":true,"lab_locations_zh":[{"name":"检测实验室","address":"ul. Rubież 46","city":null,"postal":null}]},"methods":[{"_id":"6a82ef02884ede9a1b2c4bca","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Zawartość nikotyny","parameters":[{"name":"Zakres","range":"(1 – 40) mg/ml"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość nikotyny\nZakres (1 – 40) mg/ml\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-01 wydanie 5 z dnia 13.01.2023 r.","norm_bases":["PB-01 wydanie 5 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Zawartość nikotyny\nZakres (1 – 40) mg/ml\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-01 wydanie 5 z dnia 13.01.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Zawartosc nikotyny\nZakres (1 – 40) mg/ml\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-01 wydanie 5 z dnia 13.01.2023 r.","categories":["electronics"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Nicotine content","parameters_en":[{"name":"Range","range":"(1 – 40) mg/ml"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Nicotine content Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Range PB-01 wydanie 5 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","methodology_zh":"尼古丁含量","parameters_zh":[{"name":"范围","range":"(1 – 40) mg/ml"}],"search_zh":"烟草制品：电子烟用尼古丁液 尼古丁含量 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 PB-01 wydanie 5 z dnia 13.01.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bcb","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Zawartość nikotyny","parameters":[{"name":"Zakres","range":"(0,05 – 1) mg/ml"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość nikotyny\nZakres (0,05 – 1) mg/ml\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-02 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-02 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Zawartość nikotyny\nZakres (0,05 – 1) mg/ml\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-02 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Zawartosc nikotyny\nZakres (0,05 – 1) mg/ml\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-02 wydanie 4 z dnia 13.01.2023 r.","categories":["electronics"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Nicotine content","parameters_en":[{"name":"Range","range":"(0,05 – 1) mg/ml"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Nicotine content Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Range PB-02 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","methodology_zh":"尼古丁含量","parameters_zh":[{"name":"范围","range":"(0,05 – 1) mg/ml"}],"search_zh":"烟草制品：电子烟用尼古丁液 尼古丁含量 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 PB-02 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bcc","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Stężenie związków organicznych","parameters":[{"name":"nikotyna","range":"(2,00 – 40,0) mg/ml"},{"name":"gliceryna","range":"(100 – 1000) mg/ml"},{"name":"glikol propylenowy","range":"(100 – 1000) mg/ml"},{"name":"Stężenie związków organicznych w mg/g (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie związków organicznych\nZakres:\nnikotyna (2,00 – 40,0) mg/ml\ngliceryna (100 – 1000) mg/ml\nglikol propylenowy (100 – 1000) mg/ml\nStężenie związków organicznych w mg/g (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ISO 20714:2019","norm_bases":["ISO 20714:2019"],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Stężenie związków organicznych\nZakres:\nnikotyna (2,00 – 40,0) mg/ml\ngliceryna (100 – 1000) mg/ml\nglikol propylenowy (100 – 1000) mg/ml\nStężenie związków organicznych w mg/g (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ISO 20714:2019 Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Stezenie zwiazkow organicznych\nZakres:\nnikotyna (2,00 – 40,0) mg/ml\ngliceryna (100 – 1000) mg/ml\nglikol propylenowy (100 – 1000) mg/ml\nStezenie zwiazkow organicznych w mg/g (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ISO 20714:2019","categories":["electronics"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of organic compounds","parameters_en":[{"name":"nicotine","range":"(2,00 – 40,0) mg/ml"},{"name":"glycerine","range":"(100 – 1000) mg/ml"},{"name":"propylene glycol","range":"(100 – 1000) mg/ml"},{"name":"Concentration of organic compounds in mg/g (calculated)"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Concentration of organic compounds Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory nicotine glycerine propylene glycol Concentration of organic compounds in mg/g (calculated) ISO 20714:2019","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","search_zh":"烟草制品：电子烟用尼古丁液 有机化合物浓度 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 ISO 20714:2019","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"有机化合物浓度","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bcd","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Stężenie kwasu benzoesowego","parameters":[{"name":"Zakres","range":"(1 – 20) mg/ml"},{"name":"Stężenie kwasu benzoesowego w mg/g (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fotodiodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fotodiodową (HPLC-DAD)"],"computed":[],"activity":"Stężenie kwasu benzoesowego\nZakres:\nZakres (1 – 20) mg/ml\nStężenie kwasu benzoesowego w mg/g (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fotodiodową (HPLC-DAD)","reference":"PB-26 wydanie 2 z dnia 13.01.2023 r.","norm_bases":["PB-26 wydanie 2 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Stężenie kwasu benzoesowego\nZakres:\nZakres (1 – 20) mg/ml\nStężenie kwasu benzoesowego w mg/g (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fotodiodową (HPLC-DAD) PB-26 wydanie 2 z dnia 13.01.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Stezenie kwasu benzoesowego\nZakres:\nZakres (1 – 20) mg/ml\nStezenie kwasu benzoesowego w mg/g (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fotodiodowa (HPLC-DAD) PB-26 wydanie 2 z dnia 13.01.2023 r.","categories":["electronics"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Benzoic acid concentration","parameters_en":[{"name":"Range","range":"(1 – 20) mg/ml"},{"name":"Benzoic acid concentration in mg/g (calculated)"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Benzoic acid concentration High-performance liquid chromatography with photodiode array detection (HPLC-DAD) Testing Laboratory Range Benzoic acid concentration in mg/g (calculated) PB-26 wydanie 2 z dnia 13.01.2023 r.","technique_en":"High-performance liquid chromatography with photodiode array detection (HPLC-DAD)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(1 – 20) mg/ml"},{"name":"Stężenie kwasu benzoesowego w mg/g (z obliczeń)"}],"search_zh":"烟草制品：电子烟用尼古丁液 高效液相色谱-光电二极管阵列检测法（HPLC-DAD） 检测实验室 范围 PB-26 wydanie 2 z dnia 13.01.2023 r.","test_object_zh":"烟草制品：电子烟用尼古丁液","technique_zh":"高效液相色谱-光电二极管阵列检测法（HPLC-DAD）"},{"_id":"6a82ef02884ede9a1b2c4bce","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PB-27 wydanie 4 z dnia 13.01.2026 r.","norm_bases":["PB-27 wydanie 4 z dnia 13.01.2026 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PB-27 wydanie 4 z dnia 13.01.2026 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PB-27 wydanie 4 z dnia 13.01.2026 r.","categories":["electronics"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes pH Potentiometric method Testing Laboratory Range PB-27 wydanie 4 z dnia 13.01.2026 r.","technique_en":"Potentiometric method","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"烟草制品：电子烟用尼古丁液 pH 值 电位法 检测实验室 范围 PB-27 wydanie 4 z dnia 13.01.2026 r.","technique_zh":"电位法","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bcf","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,9379 – 1,2845) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna","reference":"PB-28 wydanie 3 z dnia 21.07.2023 r.","norm_bases":["PB-28 wydanie 3 z dnia 21.07.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Gęstość\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna PB-28 wydanie 3 z dnia 21.07.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Gestosc\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna PB-28 wydanie 3 z dnia 21.07.2023 r.","categories":["electronics"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,9379 – 1,2845) g/cm3"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Density Oscillation method Testing Laboratory Range PB-28 wydanie 3 z dnia 21.07.2023 r.","technique_en":"Oscillation method","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,9379 – 1,2845) g/cm3"}],"search_zh":"烟草制品：电子烟用尼古丁液 密度 振荡法 检测实验室 范围 PB-28 wydanie 3 z dnia 21.07.2023 r.","technique_zh":"振荡法","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bd0","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(43 – 184) °C"}],"technique":"Modyfikowana metoda ciągle zamkniętego tygla (MCCCFP)","techniques":["Modyfikowana metoda ciągle zamkniętego tygla (MCCCFP)"],"computed":[],"activity":"Temperatura zapłonu\nZakres (43 – 184) °C\nModyfikowana metoda ciągle zamkniętego tygla (MCCCFP)","reference":"PB-29 wydanie 2 z dnia 13.01.2023 r.","norm_bases":["PB-29 wydanie 2 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Temperatura zapłonu\nZakres (43 – 184) °C\nModyfikowana metoda ciągle zamkniętego tygla (MCCCFP) PB-29 wydanie 2 z dnia 13.01.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Temperatura zaplonu\nZakres (43 – 184) °C\nModyfikowana metoda ciagle zamknietego tygla (MCCCFP) PB-29 wydanie 2 z dnia 13.01.2023 r.","categories":["electronics"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(43 – 184) °C"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Flash point Modified continuously closed cup method (MCCCFP) Testing Laboratory Range PB-29 wydanie 2 z dnia 13.01.2023 r.","technique_en":"Modified continuously closed cup method (MCCCFP)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(43 – 184) °C"}],"search_zh":"烟草制品：电子烟用尼古丁液 闪点 检测实验室 范围 PB-29 wydanie 2 z dnia 13.01.2023 r.","methodology_zh":"闪点","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bd1","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,30 – 12,0 ) % m/m"}],"technique":"Metoda miareczkowania wolumetrycznego (wg Karla Fischera)","techniques":["Metoda miareczkowania wolumetrycznego (wg Karla Fischera)"],"computed":[],"activity":"Zawartość wody\nZakres (0,30 – 12,0 ) % m/m\nMetoda miareczkowania wolumetrycznego (wg Karla Fischera)","reference":"PB-32 wydanie 1 z dnia 18.04.2023 r.","norm_bases":["PB-32 wydanie 1 z dnia 18.04.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: płyn nikotynowy do papierosów elektronicznych Zawartość wody\nZakres (0,30 – 12,0 ) % m/m\nMetoda miareczkowania wolumetrycznego (wg Karla Fischera) PB-32 wydanie 1 z dnia 18.04.2023 r. Wyroby tytoniowe: plyn nikotynowy do papierosow elektronicznych Zawartosc wody\nZakres (0,30 – 12,0 ) % m/m\nMetoda miareczkowania wolumetrycznego (wg Karla Fischera) PB-32 wydanie 1 z dnia 18.04.2023 r.","categories":["water","electronics"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,30 – 12,0 ) % m/m"}],"search_en":"Tobacco products: nicotine liquid for electronic cigarettes Water content Volumetric titration method (according to Karl Fischer) Testing Laboratory Range PB-32 wydanie 1 z dnia 18.04.2023 r.","technique_en":"Volumetric titration method (according to Karl Fischer)","test_object_en":"Tobacco products: nicotine liquid for electronic cigarettes","lab_section_zh":"检测实验室","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,30 – 12,0 ) % m/m"}],"search_zh":"烟草制品：电子烟用尼古丁液 水分含量 检测实验室 范围 PB-32 wydanie 1 z dnia 18.04.2023 r.","test_object_zh":"烟草制品：电子烟用尼古丁液"},{"_id":"6a82ef02884ede9a1b2c4bd2","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby chemiczne: aromaty","methodology":"Gęstość","parameters":[{"name":"Zakres","range":"(0,9379 – 1,2845) g/cm3"}],"technique":"Metoda oscylacyjna","techniques":["Metoda oscylacyjna"],"computed":[],"activity":"Gęstość\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna","reference":"PB-28 wydanie 3 z dnia 21.07.2023 r.","norm_bases":["PB-28 wydanie 3 z dnia 21.07.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: aromaty Gęstość\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna PB-28 wydanie 3 z dnia 21.07.2023 r. Wyroby chemiczne: aromaty Gestosc\nZakres (0,9379 – 1,2845) g/cm3\nMetoda oscylacyjna PB-28 wydanie 3 z dnia 21.07.2023 r.","categories":["other"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Density","parameters_en":[{"name":"Range","range":"(0,9379 – 1,2845) g/cm3"}],"search_en":"Chemical products: flavourings Density Oscillation method Testing Laboratory Range PB-28 wydanie 3 z dnia 21.07.2023 r.","technique_en":"Oscillation method","test_object_en":"Chemical products: flavourings","lab_section_zh":"检测实验室","methodology_zh":"密度","parameters_zh":[{"name":"范围","range":"(0,9379 – 1,2845) g/cm3"}],"search_zh":"密度 振荡法 检测实验室 范围 PB-28 wydanie 3 z dnia 21.07.2023 r.","technique_zh":"振荡法"},{"_id":"6a82ef02884ede9a1b2c4bd3","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby chemiczne: aromaty","methodology":"Temperatura zapłonu","parameters":[{"name":"Zakres","range":"(43 – 184) °C"}],"technique":"Modyfikowana metoda ciągle zamkniętego tygla (MCCCFP)","techniques":["Modyfikowana metoda ciągle zamkniętego tygla (MCCCFP)"],"computed":[],"activity":"Temperatura zapłonu\nZakres (43 – 184) °C\nModyfikowana metoda ciągle zamkniętego tygla (MCCCFP)","reference":"PB-29 wydanie 2 z dnia 13.01.2023 r.","norm_bases":["PB-29 wydanie 2 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby chemiczne: aromaty Temperatura zapłonu\nZakres (43 – 184) °C\nModyfikowana metoda ciągle zamkniętego tygla (MCCCFP) PB-29 wydanie 2 z dnia 13.01.2023 r. Wyroby chemiczne: aromaty Temperatura zaplonu\nZakres (43 – 184) °C\nModyfikowana metoda ciagle zamknietego tygla (MCCCFP) PB-29 wydanie 2 z dnia 13.01.2023 r.","categories":["other"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Flash point","parameters_en":[{"name":"Range","range":"(43 – 184) °C"}],"search_en":"Chemical products: flavourings Flash point Modified continuously closed cup method (MCCCFP) Testing Laboratory Range PB-29 wydanie 2 z dnia 13.01.2023 r.","technique_en":"Modified continuously closed cup method (MCCCFP)","test_object_en":"Chemical products: flavourings","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(43 – 184) °C"}],"search_zh":"闪点 检测实验室 范围 PB-29 wydanie 2 z dnia 13.01.2023 r.","methodology_zh":"闪点"},{"_id":"6a82ef02884ede9a1b2c4bd4","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych","methodology":"Stężenie wody","parameters":[{"name":"Zakres","range":"(0,25 – 5) mg/ml"},{"name":"Zawartość wody w mg/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)"],"computed":[],"activity":"Stężenie wody\nZakres:\nZakres (0,25 – 5) mg/ml\nZawartość wody w mg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD)","reference":"PB-03 wydanie 6 z dnia 13.01.2023 r.","norm_bases":["PB-03 wydanie 6 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych Stężenie wody\nZakres:\nZakres (0,25 – 5) mg/ml\nZawartość wody w mg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją termokonduktometryczną (GC-TCD) PB-03 wydanie 6 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow szklanych Stezenie wody\nZakres:\nZakres (0,25 – 5) mg/ml\nZawartosc wody w mg/liczbe zaciagniec (z obliczen)\nMetoda chromatografii gazowej z detekcja termokonduktometryczna (GC-TCD) PB-03 wydanie 6 z dnia 13.01.2023 r.","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Water concentration","parameters_en":[{"name":"Range","range":"(0,25 – 5) mg/ml"},{"name":"Water content in mg/number of puffs (calculated)"}],"search_en":"Tobacco products: aerosol extracted from glass filters Water concentration Gas chromatography with thermal conductivity detection (GC-TCD) Testing Laboratory Range Water content in mg/number of puffs (calculated) PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with thermal conductivity detection (GC-TCD)","test_object_en":"Tobacco products: aerosol extracted from glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,25 – 5) mg/ml"},{"name":"Zawartość wody w mg/liczbę zaciągnięć (z obliczeń)"}],"search_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶 气相色谱-热导检测法（GC-TCD） 检测实验室 范围 PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_zh":"气相色谱-热导检测法（GC-TCD）","test_object_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bd5","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(23,7 – 380,3) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa","reference":"PB-03 wydanie 6 z dnia 13.01.2023 r.","norm_bases":["PB-03 wydanie 6 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa PB-03 wydanie 6 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa PB-03 wydanie 6 z dnia 13.01.2023 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(23,7 – 380,3) mg"}],"search_en":"Tobacco products: aerosol deposited on glass filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(23,7 – 380,3) mg"}],"search_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶 气溶胶质量（ACM） 重量法 检测实验室 范围 PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）","test_object_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bd6","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(24,9 – 415,7) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa","reference":"PB-03 wydanie 6 z dnia 13.01.2023 r.","norm_bases":["PB-03 wydanie 6 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa PB-03 wydanie 6 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa PB-03 wydanie 6 z dnia 13.01.2023 r.","categories":["other"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(24,9 – 415,7) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(24,9 – 415,7) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-03 wydanie 6 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bd7","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych","methodology":"Stężenie tlenku propylenu","parameters":[{"name":"Zakres","range":"(0,05 – 2) µg/ml"},{"name":"Zawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie tlenku propylenu\nZakres:\nZakres (0,05 – 2) µg/ml\nZawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)","reference":"PB-05 wydanie 5 z dnia 13.01.2023 r.","norm_bases":["PB-05 wydanie 5 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych Stężenie tlenku propylenu\nZakres:\nZakres (0,05 – 2) µg/ml\nZawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej detekcją spektrometrią mas (GC-MS) PB-05 wydanie 5 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow szklanych Stezenie tlenku propylenu\nZakres:\nZakres (0,05 – 2) µg/ml\nZawartosc tlenku propylenu w µg/liczbe zaciagniec (z obliczen)\nMetoda chromatografii gazowej detekcja spektrometria mas (GC-MS) PB-05 wydanie 5 z dnia 13.01.2023 r.","categories":["other"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Propylene oxide concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2) µg/ml"},{"name":"Zawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń)"}],"search_en":"Tobacco products: aerosol extracted from glass filters Propylene oxide concentration Gas chromatography with mass spectrometry detection (GC-MS) Testing Laboratory Range PB-05 wydanie 5 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Tobacco products: aerosol extracted from glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,05 – 2) µg/ml"},{"name":"Zawartość tlenku propylenu w µg/liczbę zaciągnięć (z obliczeń)"}],"search_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶 检测实验室 范围 PB-05 wydanie 5 z dnia 13.01.2023 r.","test_object_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bd8","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(20,7 – 370,8) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa","reference":"PB-05 wydanie 5 z dnia 13.01.2023 r.","norm_bases":["PB-05 wydanie 5 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-05 wydanie 5 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-05 wydanie 5 z dnia 13.01.2023 r.","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(20,7 – 370,8) mg"}],"search_en":"Tobacco products: aerosol deposited on glass filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-05 wydanie 5 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(20,7 – 370,8) mg"}],"search_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶 气溶胶质量（ACM） 重量法 检测实验室 范围 PB-05 wydanie 5 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）","test_object_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bd9","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(22,0 – 407,1) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa","reference":"PB-05 wydanie 5 z dnia 13.01.2023 r.","norm_bases":["PB-05 wydanie 5 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-05 wydanie 5 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-05 wydanie 5 z dnia 13.01.2023 r.","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(22,0 – 407,1) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-05 wydanie 5 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(22,0 – 407,1) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-05 wydanie 5 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bda","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych","methodology":"Stężenie związków organicznych","parameters":[{"name":"formaldehyd","range":"(0,1 – 10) µg/ml"},{"name":"aceton","range":"(0,1 – 10) µg/ml"},{"name":"2-butanon","range":"(0,1 – 10) µg/ml"},{"name":"diacetyl","range":"(0,1 – 10) µg/ml"},{"name":"glioksal","range":"(0,1 – 10) µg/ml"},{"name":"acetaldehyd","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd propionowy","range":"(0,1 – 10) µg/ml"},{"name":"akroleina","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd masłowy","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd krotonowy","range":"(0,1 – 10) µg/ml"},{"name":"metyloglioksal","range":"(0,1 – 10) µg/ml"},{"name":"Zawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie związków organicznych\nZakres:\nformaldehyd (0,1 – 10) µg/ml\naceton (0,1 – 10) µg/ml\n2-butanon (0,1 – 10) µg/ml\ndiacetyl (0,1 – 10) µg/ml\nglioksal (0,1 – 10) µg/ml\nacetaldehyd (0,1 – 10) µg/ml\naldehyd propionowy (0,1 – 10) µg/ml\nakroleina (0,1 – 10) µg/ml\naldehyd masłowy (0,1 – 10) µg/ml\naldehyd krotonowy (0,1 – 10) µg/ml\nmetyloglioksal (0,1 – 10) µg/ml\nZawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej detekcją spektrometrią mas (GC-MS)","reference":"PB-06 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-06 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych Stężenie związków organicznych\nZakres:\nformaldehyd (0,1 – 10) µg/ml\naceton (0,1 – 10) µg/ml\n2-butanon (0,1 – 10) µg/ml\ndiacetyl (0,1 – 10) µg/ml\nglioksal (0,1 – 10) µg/ml\nacetaldehyd (0,1 – 10) µg/ml\naldehyd propionowy (0,1 – 10) µg/ml\nakroleina (0,1 – 10) µg/ml\naldehyd masłowy (0,1 – 10) µg/ml\naldehyd krotonowy (0,1 – 10) µg/ml\nmetyloglioksal (0,1 – 10) µg/ml\nZawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej detekcją spektrometrią mas (GC-MS) PB-06 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow szklanych Stezenie zwiazkow organicznych\nZakres:\nformaldehyd (0,1 – 10) µg/ml\naceton (0,1 – 10) µg/ml\n2-butanon (0,1 – 10) µg/ml\ndiacetyl (0,1 – 10) µg/ml\nglioksal (0,1 – 10) µg/ml\nacetaldehyd (0,1 – 10) µg/ml\naldehyd propionowy (0,1 – 10) µg/ml\nakroleina (0,1 – 10) µg/ml\naldehyd maslowy (0,1 – 10) µg/ml\naldehyd krotonowy (0,1 – 10) µg/ml\nmetyloglioksal (0,1 – 10) µg/ml\nZawartosc zwiazkow organicznych w µg/liczbe zaciagniec (z obliczen)\nMetoda chromatografii gazowej detekcja spektrometria mas (GC-MS) PB-06 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of organic compounds","parameters_en":[{"name":"formaldehyde","range":"(0,1 – 10) µg/ml"},{"name":"acetone","range":"(0,1 – 10) µg/ml"},{"name":"2-butanon","range":"(0,1 – 10) µg/ml"},{"name":"diacetyl","range":"(0,1 – 10) µg/ml"},{"name":"glyoxal","range":"(0,1 – 10) µg/ml"},{"name":"acetaldehyde","range":"(0,1 – 10) µg/ml"},{"name":"propionaldehyde","range":"(0,1 – 10) µg/ml"},{"name":"acrolein","range":"(0,1 – 10) µg/ml"},{"name":"butyraldehyde","range":"(0,1 – 10) µg/ml"},{"name":"crotonaldehyde","range":"(0,1 – 10) µg/ml"},{"name":"methylglyoxal","range":"(0,1 – 10) µg/ml"},{"name":"Zawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń)"}],"search_en":"Tobacco products: aerosol extracted from glass filters Concentration of organic compounds Gas chromatography with mass spectrometry detection (GC-MS) Testing Laboratory formaldehyde acetone diacetyl glyoxal acetaldehyde propionaldehyde acrolein butyraldehyde crotonaldehyde methylglyoxal PB-06 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Tobacco products: aerosol extracted from glass filters","lab_section_zh":"检测实验室","search_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶 有机化合物浓度 检测实验室 甲醛 丙酮 乙醛 PB-06 wydanie 4 z dnia 13.01.2023 r.","methodology_zh":"有机化合物浓度","parameters_zh":[{"name":"甲醛","range":"(0,1 – 10) µg/ml"},{"name":"丙酮","range":"(0,1 – 10) µg/ml"},{"name":"2-butanon","range":"(0,1 – 10) µg/ml"},{"name":"diacetyl","range":"(0,1 – 10) µg/ml"},{"name":"glioksal","range":"(0,1 – 10) µg/ml"},{"name":"乙醛","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd propionowy","range":"(0,1 – 10) µg/ml"},{"name":"akroleina","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd masłowy","range":"(0,1 – 10) µg/ml"},{"name":"aldehyd krotonowy","range":"(0,1 – 10) µg/ml"},{"name":"metyloglioksal","range":"(0,1 – 10) µg/ml"},{"name":"Zawartość związków organicznych w µg/liczbę zaciągnięć (z obliczeń)"}],"test_object_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bdb","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(20,7 – 370,8) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa","reference":"PB-06 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-06 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-06 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-06 wydanie 4 z dnia 13.01.2023 r.","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(20,7 – 370,8) mg"}],"search_en":"Tobacco products: aerosol deposited on glass filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-06 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(20,7 – 370,8) mg"}],"search_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶 气溶胶质量（ACM） 重量法 检测实验室 范围 PB-06 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）","test_object_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bdc","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(22,0 – 407,1) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa","reference":"PB-06 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-06 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-06 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-06 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(22,0 – 407,1) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-06 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(22,0 – 407,1) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-06 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"},{"_id":"6a82ef02884ede9a1b2c4bdd","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów kwarcowych","methodology":"Stężenie pierwiastków","parameters":[{"name":"srebro","range":"(5,0 – 20) µg/l"},{"name":"glin","range":"(5,0 – 20) µg/l"},{"name":"złoto","range":"(5,0 – 20) µg/l"},{"name":"arsen","range":"(0,5 – 20) µg/l"},{"name":"beryl","range":"(0,5 – 20) µg/l"},{"name":"kadm","range":"(0,5 – 20) µg/l"},{"name":"kobalt","range":"(0,5 – 20) µg/l"},{"name":"chrom","range":"(0,5 – 20) µg/l"},{"name":"miedź","range":"(3,0 – 20) µg/l"},{"name":"żelazo","range":"(1,0 – 20) µg/l"},{"name":"mangan","range":"(0,5 – 20) µg/l"},{"name":"molibden","range":"(0,5 – 20) µg/l"},{"name":"nikiel","range":"(0,5 – 20) µg/l"},{"name":"ołów","range":"(0,5 – 20) µg/l"},{"name":"selen","range":"(0,5 – 20) µg/l"},{"name":"cyna","range":"(0,5 – 20) µg/l"},{"name":"tytan","range":"(0,5 – 20) µg/l"},{"name":"wolfram","range":"(0,5 – 20) µg/l"},{"name":"cynk","range":"(3,0 – 20) µg/l"},{"name":"cyrkon","range":"(5,0 – 20) µg/l"},{"name":"Zawartość pierwiastków w ng/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nsrebro (5,0 – 20) µg/l\nglin (5,0 – 20) µg/l\nzłoto (5,0 – 20) µg/l\narsen (0,5 – 20) µg/l\nberyl (0,5 – 20) µg/l\nkadm (0,5 – 20) µg/l\nkobalt (0,5 – 20) µg/l\nchrom (0,5 – 20) µg/l\nmiedź (3,0 – 20) µg/l\nżelazo (1,0 – 20) µg/l\nmangan (0,5 – 20) µg/l\nmolibden (0,5 – 20) µg/l\nnikiel (0,5 – 20) µg/l\nołów (0,5 – 20) µg/l\nselen (0,5 – 20) µg/l\ncyna (0,5 – 20) µg/l\ntytan (0,5 – 20) µg/l\nwolfram (0,5 – 20) µg/l\ncynk (3,0 – 20) µg/l\ncyrkon (5,0 – 20) µg/l\nZawartość pierwiastków w ng/liczbę zaciągnięć (z obliczeń)\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS)","reference":"PB-12 wydanie 7 z dnia 13.01.2023 r.","norm_bases":["PB-12 wydanie 7 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów kwarcowych Stężenie pierwiastków\nZakres:\nsrebro (5,0 – 20) µg/l\nglin (5,0 – 20) µg/l\nzłoto (5,0 – 20) µg/l\narsen (0,5 – 20) µg/l\nberyl (0,5 – 20) µg/l\nkadm (0,5 – 20) µg/l\nkobalt (0,5 – 20) µg/l\nchrom (0,5 – 20) µg/l\nmiedź (3,0 – 20) µg/l\nżelazo (1,0 – 20) µg/l\nmangan (0,5 – 20) µg/l\nmolibden (0,5 – 20) µg/l\nnikiel (0,5 – 20) µg/l\nołów (0,5 – 20) µg/l\nselen (0,5 – 20) µg/l\ncyna (0,5 – 20) µg/l\ntytan (0,5 – 20) µg/l\nwolfram (0,5 – 20) µg/l\ncynk (3,0 – 20) µg/l\ncyrkon (5,0 – 20) µg/l\nZawartość pierwiastków w ng/liczbę zaciągnięć (z obliczeń)\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS) PB-12 wydanie 7 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow kwarcowych Stezenie pierwiastkow\nZakres:\nsrebro (5,0 – 20) µg/l\nglin (5,0 – 20) µg/l\nzloto (5,0 – 20) µg/l\narsen (0,5 – 20) µg/l\nberyl (0,5 – 20) µg/l\nkadm (0,5 – 20) µg/l\nkobalt (0,5 – 20) µg/l\nchrom (0,5 – 20) µg/l\nmiedz (3,0 – 20) µg/l\nzelazo (1,0 – 20) µg/l\nmangan (0,5 – 20) µg/l\nmolibden (0,5 – 20) µg/l\nnikiel (0,5 – 20) µg/l\nolow (0,5 – 20) µg/l\nselen (0,5 – 20) µg/l\ncyna (0,5 – 20) µg/l\ntytan (0,5 – 20) µg/l\nwolfram (0,5 – 20) µg/l\ncynk (3,0 – 20) µg/l\ncyrkon (5,0 – 20) µg/l\nZawartosc pierwiastkow w ng/liczbe zaciagniec (z obliczen)\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP-MS) PB-12 wydanie 7 z dnia 13.01.2023 r.","categories":["materials"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Element concentration","parameters_en":[{"name":"silver","range":"(5,0 – 20) µg/l"},{"name":"aluminium","range":"(5,0 – 20) µg/l"},{"name":"gold","range":"(5,0 – 20) µg/l"},{"name":"arsenic","range":"(0,5 – 20) µg/l"},{"name":"beryllium","range":"(0,5 – 20) µg/l"},{"name":"cadmium","range":"(0,5 – 20) µg/l"},{"name":"cobalt","range":"(0,5 – 20) µg/l"},{"name":"chromium","range":"(0,5 – 20) µg/l"},{"name":"copper","range":"(3,0 – 20) µg/l"},{"name":"iron","range":"(1,0 – 20) µg/l"},{"name":"manganese","range":"(0,5 – 20) µg/l"},{"name":"molybdenum","range":"(0,5 – 20) µg/l"},{"name":"nickel","range":"(0,5 – 20) µg/l"},{"name":"lead","range":"(0,5 – 20) µg/l"},{"name":"selenium","range":"(0,5 – 20) µg/l"},{"name":"tin","range":"(0,5 – 20) µg/l"},{"name":"titanium","range":"(0,5 – 20) µg/l"},{"name":"tungsten","range":"(0,5 – 20) µg/l"},{"name":"zinc","range":"(3,0 – 20) µg/l"},{"name":"zirconium","range":"(5,0 – 20) µg/l"},{"name":"Content of elements in ng/number of puffs (calculated)"}],"search_en":"Tobacco products: aerosol extracted from quartz filters Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) Testing Laboratory silver aluminium gold arsenic beryllium cadmium cobalt chromium copper iron manganese molybdenum nickel lead selenium tin titanium tungsten zinc zirconium Content of elements in ng/number of puffs (calculated) PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","test_object_en":"Tobacco products: aerosol extracted from quartz filters","lab_section_zh":"检测实验室","methodology_zh":"元素浓度","parameters_zh":[{"name":"银","range":"(5,0 – 20) µg/l"},{"name":"铝","range":"(5,0 – 20) µg/l"},{"name":"złoto","range":"(5,0 – 20) µg/l"},{"name":"砷","range":"(0,5 – 20) µg/l"},{"name":"铍","range":"(0,5 – 20) µg/l"},{"name":"镉","range":"(0,5 – 20) µg/l"},{"name":"钴","range":"(0,5 – 20) µg/l"},{"name":"铬","range":"(0,5 – 20) µg/l"},{"name":"铜","range":"(3,0 – 20) µg/l"},{"name":"铁","range":"(1,0 – 20) µg/l"},{"name":"锰","range":"(0,5 – 20) µg/l"},{"name":"钼","range":"(0,5 – 20) µg/l"},{"name":"镍","range":"(0,5 – 20) µg/l"},{"name":"铅","range":"(0,5 – 20) µg/l"},{"name":"硒","range":"(0,5 – 20) µg/l"},{"name":"锡","range":"(0,5 – 20) µg/l"},{"name":"钛","range":"(0,5 – 20) µg/l"},{"name":"wolfram","range":"(0,5 – 20) µg/l"},{"name":"锌","range":"(3,0 – 20) µg/l"},{"name":"cyrkon","range":"(5,0 – 20) µg/l"},{"name":"Zawartość pierwiastków w ng/liczbę zaciągnięć (z obliczeń)"}],"search_zh":"元素浓度 电感耦合等离子体质谱法（ICP-MS） 检测实验室 银 铝 砷 铍 镉 钴 铬 铜 铁 锰 钼 镍 铅 硒 锡 钛 锌 PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a82ef02884ede9a1b2c4bde","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach kwarcowych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(23,6 – 407,4) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (23,6 – 407,4) mg\nMetoda wagowa","reference":"PB-12 wydanie 7 z dnia 13.01.2023 r.","norm_bases":["PB-12 wydanie 7 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach kwarcowych Masa aerozolu (ACM)\nZakres (23,6 – 407,4) mg\nMetoda wagowa PB-12 wydanie 7 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach kwarcowych Masa aerozolu (ACM)\nZakres (23,6 – 407,4) mg\nMetoda wagowa PB-12 wydanie 7 z dnia 13.01.2023 r.","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(23,6 – 407,4) mg"}],"search_en":"Tobacco products: aerosol deposited on quartz filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on quartz filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(23,6 – 407,4) mg"}],"search_zh":"气溶胶质量（ACM） 重量法 检测实验室 范围 PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）"},{"_id":"6a82ef02884ede9a1b2c4bdf","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(24,6 – 494,3) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (24,6 – 494,3) mg\nMetoda wagowa","reference":"PB-12 wydanie 7 z dnia 13.01.2023 r.","norm_bases":["PB-12 wydanie 7 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,6 – 494,3) mg\nMetoda wagowa PB-12 wydanie 7 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,6 – 494,3) mg\nMetoda wagowa PB-12 wydanie 7 z dnia 13.01.2023 r.","categories":["other"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(24,6 – 494,3) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(24,6 – 494,3) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-12 wydanie 7 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be0","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych","methodology":"Stężenie związków organicznych","parameters":[{"name":"nikotyna","range":"(0,01 – 0,4) mg/ml"},{"name":"mentol","range":"(0,01 – 0,4) mg/ml"},{"name":"glikol propylenowy","range":"(0,5 – 15) mg/ml"},{"name":"gliceryna","range":"(0,5 – 15) mg/ml"},{"name":"Zawartość związków organicznych w mg/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie związków organicznych\nZakres:\nnikotyna (0,01 – 0,4) mg/ml\nmentol (0,01 – 0,4) mg/ml\nglikol propylenowy (0,5 – 15) mg/ml\ngliceryna (0,5 – 15) mg/ml\nZawartość związków organicznych w mg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-15 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-15 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych Stężenie związków organicznych\nZakres:\nnikotyna (0,01 – 0,4) mg/ml\nmentol (0,01 – 0,4) mg/ml\nglikol propylenowy (0,5 – 15) mg/ml\ngliceryna (0,5 – 15) mg/ml\nZawartość związków organicznych w mg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-15 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow szklanych Stezenie zwiazkow organicznych\nZakres:\nnikotyna (0,01 – 0,4) mg/ml\nmentol (0,01 – 0,4) mg/ml\nglikol propylenowy (0,5 – 15) mg/ml\ngliceryna (0,5 – 15) mg/ml\nZawartosc zwiazkow organicznych w mg/liczbe zaciagniec (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-15 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Concentration of organic compounds","parameters_en":[{"name":"nicotine","range":"(0,01 – 0,4) mg/ml"},{"name":"menthol","range":"(0,01 – 0,4) mg/ml"},{"name":"propylene glycol","range":"(0,5 – 15) mg/ml"},{"name":"glycerine","range":"(0,5 – 15) mg/ml"},{"name":"Content of organic compounds in mg/number of puffs (calculated)"}],"search_en":"Tobacco products: aerosol extracted from glass filters Concentration of organic compounds Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory nicotine menthol propylene glycol glycerine Content of organic compounds in mg/number of puffs (calculated) PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Tobacco products: aerosol extracted from glass filters","lab_section_zh":"检测实验室","search_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶 有机化合物浓度 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"有机化合物浓度","test_object_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be1","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(23,7 – 380,3) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa","reference":"PB-15 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-15 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa PB-15 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (23,7 – 380,3) mg\nMetoda wagowa PB-15 wydanie 4 z dnia 13.01.2023 r.","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(23,7 – 380,3) mg"}],"search_en":"Tobacco products: aerosol deposited on glass filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(23,7 – 380,3) mg"}],"search_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶 气溶胶质量（ACM） 重量法 检测实验室 范围 PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）","test_object_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be2","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(24,9 – 415,7) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa","reference":"PB-15 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-15 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa PB-15 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (24,9 – 415,7) mg\nMetoda wagowa PB-15 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(24,9 – 415,7) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(24,9 – 415,7) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-15 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be3","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych","methodology":"Stężenie glicydolu","parameters":[{"name":"Zakres","range":"(0,2 – 5) µg/ml"},{"name":"Zawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie glicydolu\nZakres:\nZakres (0,2 – 5) µg/ml\nZawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-23 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-23 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol wyekstrahowany z filtrów szklanych Stężenie glicydolu\nZakres:\nZakres (0,2 – 5) µg/ml\nZawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń)\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-23 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol wyekstrahowany z filtrow szklanych Stezenie glicydolu\nZakres:\nZakres (0,2 – 5) µg/ml\nZawartosc glicydolu w µg/liczbe zaciagniec (z obliczen)\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-23 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Glycidol concentration","parameters_en":[{"name":"Range","range":"(0,2 – 5) µg/ml"},{"name":"Zawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń)"}],"search_en":"Tobacco products: aerosol extracted from glass filters Glycidol concentration Gas chromatography with flame ionization detection (GC-FID) Testing Laboratory Range PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Tobacco products: aerosol extracted from glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(0,2 – 5) µg/ml"},{"name":"Zawartość glicydolu w µg/liczbę zaciągnięć (z obliczeń)"}],"search_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶 气相色谱-氢火焰离子化检测法（GC-FID） 检测实验室 范围 PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"烟草制品：从玻璃纤维滤片萃取的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be4","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych","methodology":"Masa aerozolu (ACM)","parameters":[{"name":"Zakres","range":"(20,7 – 370,8) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa","reference":"PB-23 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-23 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-23 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol osadzony na filtrach szklanych Masa aerozolu (ACM)\nZakres (20,7 – 370,8) mg\nMetoda wagowa PB-23 wydanie 4 z dnia 13.01.2023 r.","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (ACM)","parameters_en":[{"name":"Range","range":"(20,7 – 370,8) mg"}],"search_en":"Tobacco products: aerosol deposited on glass filters Aerosol mass (ACM) Gravimetric method Testing Laboratory Range PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol deposited on glass filters","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(20,7 – 370,8) mg"}],"search_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶 气溶胶质量（ACM） 重量法 检测实验室 范围 PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（ACM）","test_object_zh":"烟草制品：沉积于玻璃纤维滤片上的气溶胶"},{"_id":"6a82ef02884ede9a1b2c4be5","lab_id":"69ad52a3de79e566650fb933","country":"PL","accr_number":"AB 1745","accr_body":"PCA","test_object":"Wyroby tytoniowe: aerozol odparowany z e-papierosa","methodology":"Masa aerozolu (DML)","parameters":[{"name":"Zakres","range":"(22,0 – 407,1) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa","reference":"PB-23 wydanie 4 z dnia 13.01.2023 r.","norm_bases":["PB-23 wydanie 4 z dnia 13.01.2023 r."],"lab_section":"Laboratorium Badawcze","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-23 wydanie 4 z dnia 13.01.2023 r. Wyroby tytoniowe: aerozol odparowany z e-papierosa Masa aerozolu (DML)\nZakres (22,0 – 407,1) mg\nMetoda wagowa PB-23 wydanie 4 z dnia 13.01.2023 r.","categories":["other"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Testing Laboratory","methodology_en":"Aerosol mass (DML)","parameters_en":[{"name":"Range","range":"(22,0 – 407,1) mg"}],"search_en":"Tobacco products: aerosol vaporised from an e-cigarette Aerosol mass (DML) Gravimetric method Testing Laboratory Range PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_en":"Gravimetric method","test_object_en":"Tobacco products: aerosol vaporised from an e-cigarette","lab_section_zh":"检测实验室","parameters_zh":[{"name":"范围","range":"(22,0 – 407,1) mg"}],"search_zh":"烟草制品：电子烟蒸发气溶胶 气溶胶质量（DML） 重量法 检测实验室 范围 PB-23 wydanie 4 z dnia 13.01.2023 r.","technique_zh":"重量法","methodology_zh":"气溶胶质量（DML）","test_object_zh":"烟草制品：电子烟蒸发气溶胶"}],"has_pdf":true}