🇵🇱 MIEJSKI ZAKŁAD GOSPODARKI KOMUNALNEJ I MIESZKANIOWEJ PL

PCA AB 1742 • Przasnysz, Poland • 25 methods

Water & wastewaterMicrobiology

MIEJSKI ZAKŁAD GOSPODARKI KOMUNALNEJ I MIESZKANIOWEJ is a laboratory accredited by PCA under number AB 1742 (Przasnysz, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, MPN method.

At a glance

  • Accreditation number: PCA AB 1742
  • Methods in scope: 25
  • Types of test objects: 5
  • Techniques used: 10
  • City: Przasnysz, Poland
Accreditation number
AB 1742
Accreditation body
PCA
Address
Sp. z o.o., ul. Kacza 9, 06-300 Przasnysz, LABORATORIUM, ul. Zawodzie 70, 06-300 Przasnysz
City
Przasnysz, Poland

What this laboratory tests (5)

Analytical techniques used (10)

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4
2 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
3 Water, wastewater Biochemical oxygen demand
BOD5 Range (4 – 1000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
4 Water, wastewater Chemical oxygen demand
CODCr Range (20 – 2000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
5 Water, wastewater Total phosphorus concentration
Range (0,40 – 20,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
6 Water, wastewater Total nitrogen concentration
Range (5,0 – 200) mg/l
Spectrophotometric method PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338
7 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
8 Water, water intended for human consumption, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
9 Water, water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5
10 Water, water intended for human consumption Ammonium ion concentration
Range (0,15 – 2,5) mg/l
Spectrophotometric method PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304
11 Water, water intended for human consumption Nitrate concentration
Range (0,25 – 60) mg/l
Spectrophotometric method PN-82/C-04576.08
12 Water, water intended for human consumption Nitrite concentration
Range (0,012 – 3,0) mg/l
Spectrophotometric method PN-EN 26777:1999
13 Water, water intended for human consumption Colour
Range (2– 40) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 pkt. 6 Metoda C
14 Water, water intended for human consumption Manganese concentration
Range (15 – 700) μg/l
Spectrophotometric method PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN
15 Water, water intended for human consumption Total iron concentration
Range (30 – 3000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
16 Water, water intended for human consumption Turbidity
Range (0,20 – 45) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water, water intended for human consumption Electrical conductivity
Range (100 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
18 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6
19 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
20 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
21 Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
22 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
23 Water, water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
24 Water, water intended for human consumption Faecal streptococci count Membrane filtration method PN-EN ISO 7899-2:2004
25 Water, water intended for human consumption Most probable number of faecal streptococci MPN method PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)

Reference standards (26)

PBL-04 wydanie 01 z dnia 24.10.2017 r.
PBL-09 wydanie 02 z dnia 22.07.2019 r.
PBL-10 wydanie 02 z dnia 22.07.2019 r.
PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)
PN-82/C-04576.08
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 pkt. 6 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5
PN-ISO 6332:2001+Ap1:2016-06
na podstawie testu HACH LANGE LCK 138, 238, 338
na podstawie testu HACH LANGE LCK 304
na podstawie testu HACH LANGE metoda 8149 PAN