{"lab":{"_id":"69ad52a3de79e566650fb92f","accr_number":"AB 1742","country":"PL","accr_body":"PCA","address":"Sp. z o.o., ul. Kacza 9, 06-300 Przasnysz, LABORATORIUM, ul. Zawodzie 70, 06-300 Przasnysz","categories":["water","microbiology"],"city":"Przasnysz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"MIEJSKI ZAKŁAD GOSPODARKI KOMUNALNEJ I MIESZKANIOWEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1742.pdf"],"scope_summary":"","search_text":"miejski zakład gospodarki komunalnej i mieszkaniowej sp. z o.o., ul. kacza 9, 06-300 przasnysz, laboratorium, ul. zawodzie 70, 06-300 przasnysz water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:51.803Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:51.803Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201742,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"7","date":"25.04.2025"},"parse_date":"2026-07-20T07:09:28.511Z","parse_source":"script-pdfplumber","map_coord":[53.021211,20.885195],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":25,"microbiology":5},"category_scores":{"water":20.83,"microbiology":0.83},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259c64","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.5, 7.6, 8.2, 9.3, 9.4","test_object_zh":"水"},{"_id":"6a5dc9a8f1c10c8ce8259c65","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259c66","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(4 – 1000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(4 – 1000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"technique_en":"Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 1000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (4 – 1000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(4 – 1000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c67","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZTCr"},{"name":"Zakres","range":"(20 – 2000) mg/l O2"}],"parameters_en":[{"name":"CODCr"},{"name":"Range","range":"(20 – 2000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (20 – 2000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (20 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZTCr\nZakres (20 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand Spectrophotometric method CODCr Range PN-ISO 15705:2005","parameters_zh":[{"name":"COD-Cr"},{"name":"范围","range":"(20 – 2000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD） 分光光度法 COD-Cr 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9a8f1c10c8ce8259c68","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,40 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,40 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,40 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,40 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,40 – 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 20,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c69","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,0 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338","norm_bases":["PBL-10 wydanie 02 z dnia 22.07.2019 r.","na podstawie testu HACH LANGE LCK 138, 238, 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338 Woda, scieki Stezenie azotu ogolnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 200) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 PBL-10 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 138, 238, 338","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c6a","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9a8f1c10c8ce8259c6b","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5dc9a8f1c10c8ce8259c6c","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","norm_bases":["PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5 Woda, woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 z wylaczeniem pkt. 6.5","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","methodology_zh":"化学与物理检测用样品采集","search_zh":"水、生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 z wyłączeniem pkt. 6.5","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c6d","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,15 – 2,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,15 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,15 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304","norm_bases":["PBL-09 wydanie 02 z dnia 22.07.2019 r.","na podstawie testu HACH LANGE LCK 304"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,15 – 2,5) mg/l\nMetoda spektrofotometryczna PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,15 – 2,5) mg/l\nMetoda spektrofotometryczna PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,15 – 2,5) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PBL-09 wydanie 02 z dnia 22.07.2019 r. | na podstawie testu HACH LANGE LCK 304","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c6e","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,25 – 60) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,25 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,25 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,25 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,25 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,25 – 60) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c6f","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,012 – 3,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,012 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,012 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,012 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,012 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,012 – 3,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c70","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2– 40) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2– 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2– 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 pkt. 6 Metoda C","norm_bases":["PN-EN ISO 7887:2012 pkt. 6 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2– 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt. 6 Metoda C Woda, woda do spozycia przez ludzi Barwa\nZakres (2– 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 pkt. 6 Metoda C","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 pkt. 6 Metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2– 40) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 pkt. 6 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c71","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(15 – 700) μg/l"}],"parameters_en":[{"name":"Range","range":"(15 – 700) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna","reference":"PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN","norm_bases":["PBL-04 wydanie 01 z dnia 24.10.2017 r.","na podstawie testu HACH LANGE metoda 8149 PAN"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 700) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PBL-04 wydanie 01 z dnia 24.10.2017 r. | na podstawie testu HACH LANGE metoda 8149 PAN","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c72","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(30 – 3000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30 – 3000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 3000) μg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c73","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 45) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 45) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 45) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 45) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 45) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 45) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c74","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c75","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c76","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c77","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c78","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c79","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c7a","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9a8f1c10c8ce8259c7b","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba paciorkowców kałowych","methodology_en":"Faecal streptococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba paciorkowców kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba paciorkowców kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba paciorkowcow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Faecal streptococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 粪链球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"粪链球菌数"},{"_id":"6a5dc9a8f1c10c8ce8259c7c","lab_id":"69ad52a3de79e566650fb92f","country":"PL","accr_number":"AB 1742","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba paciorkowców kałowych","methodology_en":"Most probable number of faecal streptococci","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba paciorkowców kałowych\nMetoda NPL","reference":"PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)","norm_bases":["PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba paciorkowców kałowych\nMetoda NPL PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07) Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba paciorkowcow kalowych\nMetoda NPL PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number of faecal streptococci MPN method PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)","search_zh":"水、生活饮用水 最可能数法（MPN） PBL-12 wydanie 01 z dnia 22.06.2020 r. (na podstawie instrukcji testu firmy IDEXX z roku 2019 wyd. 06-18085-07)","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"}],"has_pdf":true}