🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL
Water & wastewater
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1724 (Lubin, Poland). Its accreditation scope covers 10 test methods in the following areas: Water & wastewater. Test objects include: Wastewater. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1724
- Methods in scope: 10
- Types of test objects: 1
- Techniques used: 5
- City: Lubin, Poland
- Accreditation number
- AB 1724
- Accreditation body
- PCA
- Address
- I KANALIZACJI Sp. z o. o. w Lubinie, ul. Rzeźnicza 1, 59-300 Lubin, LABORATORIUM, ul. Zielona 2
- City
- Lubin, Poland
What this laboratory tests (1)
- Wastewater — 10 methods
Analytical techniques used (5)
- Spectrophotometric method — 4 methods
- Electrochemical method — 2 methods
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- Titrimetric method — 1 method
Accreditation scope — test methods (10)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 2 | Wastewater | Biochemical oxygen demand - BOD5 Range (3 – 3000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 3 | Wastewater | Biochemical oxygen demand - BOD5 Range (2,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 4 | Wastewater | Chemical oxygen demand - CODCr Range (20,0 – 5000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 5 | Wastewater | Total phosphorus concentration Range (0,20 – 25,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010 | |
| 6 | Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007 + Ap1:2007 | |
| 7 | Wastewater | Nitrate nitrogen concentration Range (0,10 – 30) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 8 | Wastewater | Nitrite nitrogen concentration Range (0,005 – 1,00) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 9 | Wastewater | Total Kjeldahl nitrogen concentration Range (1,00 – 150) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 10 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
Reference standards (10)
PN-73/C-04576/14
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007 + Ap1:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11