{"lab":{"_id":"69ad52a3de79e566650fb915","accr_number":"AB 1724","country":"PL","accr_body":"PCA","address":"I KANALIZACJI Sp. z o. o. w Lubinie, ul. Rzeźnicza 1, 59-300 Lubin, LABORATORIUM, ul. Zielona 2","categories":["water"],"city":"Lubin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1724.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo wodociągów i kanalizacji sp. z o. o. w lubinie, ul. rzeźnicza 1, 59-300 lubin, laboratorium, ul. zielona 2 water other","status":"active","updated_at":"2026-03-08T14:50:51.051Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:51.051Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201724,podmiot.html","fields_of_testing":[{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"6","date":"19.07.2023"},"parse_date":"2026-07-20T07:09:28.282Z","parse_source":"script-pdfplumber","map_coord":[51.396003,16.211873],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":10},"category_scores":{"water":10},"has_zh":true},"methods":[{"_id":"6a5dc9a8f1c10c8ce8259bda","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259bdb","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3 – 3000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 – 3000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9a8f1c10c8ce8259bdc","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(2,0 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(2,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(2,0 – 6,0) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9a8f1c10c8ce8259bdd","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZTCr","methodology_en":"Chemical oxygen demand - CODCr","parameters":[{"name":"Zakres","range":"(20,0 – 5000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(20,0 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (20,0 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (20,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nZakres (20,0 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chemical oxygen demand - CODCr Spectrophotometric method Range PN-ISO 15705:2005","parameters_zh":[{"name":"范围","range":"(20,0 – 5000) mg/l O2"}],"search_zh":"污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259bde","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,20 – 25,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,20 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,20 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,20 – 25,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 25,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.7 + Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259bdf","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap1:2007","norm_bases":["PN-EN 872:2007 + Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap1:2007","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007 + Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007 + Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259be0","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 – 30) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 30) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259be1","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,005 – 1,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,005 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,005 – 1,00) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9a8f1c10c8ce8259be2","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego Kjeldahla","methodology_en":"Total Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,00 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,00 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Kjeldahla\nZakres (1,00 – 150) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego Kjeldahla\nZakres (1,00 – 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu ogolnego Kjeldahla\nZakres (1,00 – 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","parameters_zh":[{"name":"范围","range":"(1,00 – 150) mg/l"}],"search_zh":"污水 凯氏总氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水","methodology_zh":"凯氏总氮浓度"},{"_id":"6a5dc9a8f1c10c8ce8259be3","lab_id":"69ad52a3de79e566650fb915","country":"PL","accr_number":"AB 1724","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"污水"}],"has_pdf":true}