🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO PL
Water & wastewaterMicrobiology
MIEJSKIE PRZEDSIĘBIORSTWO is a laboratory accredited by PCA under number AB 1715 (Brodnica, Poland). Its accreditation scope covers 36 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water intended for human consumption, Sewage sludge, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, MPN method.
At a glance
- Accreditation number: PCA AB 1715
- Methods in scope: 36
- Types of test objects: 11
- Techniques used: 11
- City: Brodnica, Poland
- Accreditation number
- AB 1715
- Accreditation body
- PCA
- Address
- WODOCIĄGÓW I KANALIZACJI Sp. z o.o., ul. Ustronie 2A, 87-300 Brodnica, LABORATORIUM
- City
- Brodnica, Poland
What this laboratory tests (11)
- Wastewater — 7 methods
- Water intended for human consumption — 7 methods
- Sewage sludge — 5 methods
- Water, Water intended for human consumption, Wastewater — 5 methods
- Water, Water intended for human consumption — 4 methods
- Wastewater, Rainwater and snowmelt water — 2 methods
- Water, Wastewater — 2 methods
- Soil — 1 method
- Soil, Sewage sludge — 1 method
- Water — 1 method
- Water, Wastewater, Rainwater and snowmelt water — 1 method
Analytical techniques used (11)
- Spectrophotometric method — 5 methods
- Gravimetric method — 4 methods
- MPN method — 3 methods
- Titrimetric method — 3 methods
- Electrochemical method — 2 methods
- Metoda ilościowa uproszczona, parzysta, wybór niewymuszony — 2 methods
- Potentiometric method — 2 methods
- Qualitative method — 2 methods
- Manual method; Automatic method — 1 method
- Plate method (pour plate) — 1 method
- Volumetric method — 1 method
Laboratory sections (2)
- Laboratory — 34 methods
- Laboratorium; ☑ Badania wykonywane poza siedzibą Laboratorium — 2 methods
Laboratory locations
- Laboratorium — ul. Ustronie 20A
Accreditation scope — test methods (36)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Water | Sampling for chemical and physical testing | PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 3 | Water intended for human consumption | Temperature Temperature Zakres: (5,0 – 55,0) °C |
PN-77/C-04584 | ||
| 4 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 5 | Wastewater, Rainwater and snowmelt water | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 6 | Wastewater, Rainwater and snowmelt water | Temperature Temperature Zakres: (5,0 – 55,0) °C |
PN-77/C-04584 | ||
| 7 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 | ||
| 8 | Sewage sludge | Sampling for chemical, microbiological, biological and physical testing | PN-EN ISO 5667-13:2011 | ||
| 9 | Water, Water intended for human consumption, Wastewater | pH pH Zakres: 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 10 | Water, Water intended for human consumption, Wastewater | Nitrite concentration Nitrite concentration Zakres: (0,030 – 200,0) mg/l Nitrite nitrogen concentration Zakres: (0,009 – 60,9) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 11 | Water, Water intended for human consumption, Wastewater | Nitrate concentration Nitrate concentration Zakres: (0,20 – 130,0) mg/l Nitrate nitrogen concentration Zakres: (0,05 – 29,4) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 12 | Water, Water intended for human consumption, Wastewater | Chloride concentration Chloride concentration Zakres: (5 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 13 | Water, Water intended for human consumption, Wastewater | Sulfate concentration Sulfate concentration Zakres: (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 14 | Water, Wastewater | Chemical oxygen demand - CODCr CODCr Zakres: (5,0 – 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 15 | Water, Wastewater | Biochemical oxygen demand - BOD5 BOD5 Zakres: (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 16 | Water, Wastewater, Rainwater and snowmelt water | Total suspended solids (TSS) Total suspended solids (TSS) Zakres (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 17 | Wastewater | Biochemical oxygen demand - BOD5 BOD5 Zakres: (3,0 – 9000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 18 | Wastewater | Chemical oxygen demand - CODCr CODCr Zakres: (20,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 19 | Wastewater | Total phosphorus concentration Total phosphorus concentration Zakres: (0,10 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010 | |
| 20 | Wastewater | Ammonium nitrogen concentration Ammonium nitrogen concentration Zakres: (1,0 – 1000,0) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 21 | Wastewater | Kjeldahl nitrogen concentration Kjeldahl nitrogen concentration Zakres: (1,0 – 1000,0) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 22 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 23 | Wastewater | Settleable solids Settleable solids Zakres: (0,5 – 200) ml/l |
Volumetric method | PN-72/C-04559/03 | |
| 24 | Soil, Sewage sludge | pH in H2O pH in H2O Zakres: 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 25 | Sewage sludge | Dry residue Dry residue Zakres: (1,0 – 99,0) % |
Gravimetric method | PN-EN 15934:2013-02 metoda A | |
| 26 | Sewage sludge | Water content (calculated) Water content Zakres: (1,0 – 99,0) % |
PN-EN 15934:2013-02 metoda A | ||
| 27 | Sewage sludge | Loss on ignition Loss on ignition Zakres: (1,0 – 99,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 28 | Sewage sludge | Residue on ignition (calculated) Residue on ignition Zakres: (1,0 – 99,0) % |
PN-EN 15935:2022-01 | ||
| 29 | Water intended for human consumption | Odour threshold number TON Odour threshold number TON Zakres: 1 |
Metoda ilościowa uproszczona, parzysta, wybór niewymuszony | PN-EN 1622:2006 | |
| 30 | Water intended for human consumption | Taste threshold number TFN Taste threshold number TFN Zakres: 1 |
Metoda ilościowa uproszczona, parzysta, wybór niewymuszony | PN-EN 1622:2006 | |
| 31 | Water, Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 32 | Water, Water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 33 | Water, Water intended for human consumption | Most probable number of enterococci | MPN method | PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW | |
| 34 | Water, Water intended for human consumption | Total viable count at 22 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| Laboratorium; ☑ Badania wykonywane poza siedzibą Laboratorium | |||||
| 35 | Water intended for human consumption | Obecność obcego zapachu ☑ | Qualitative method | PN-EN 1622:2006 Annex C | |
| 36 | Water intended for human consumption | Obecność obcego smaku ☑ | Qualitative method | PN-EN 1622:2006 Annex C | |
Reference standards (29)
PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW
PN-72/C-04559/03
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-EN 15934:2013-02 metoda A
PN-EN 15935:2022-01
PN-EN 1622:2006
PN-EN 1622:2006 Annex C
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3
PN-ISO 5667-5:2017-10
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-R-04031:1997