{"lab":{"_id":"69ad52a3de79e566650fb90b","accr_number":"AB 1715","country":"PL","accr_body":"PCA","address":"WODOCIĄGÓW I KANALIZACJI Sp. z o.o., ul. Ustronie 2A, 87-300 Brodnica, LABORATORIUM","categories":["water","microbiology"],"city":"Brodnica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":36,"name":"MIEJSKIE PRZEDSIĘBIORSTWO","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1715.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo wodociągów i kanalizacji sp. z o.o., ul. ustronie 2a, 87-300 brodnica, laboratorium water microbiology environment other","status":"active","updated_at":"2026-03-08T14:50:50.753Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:22:28.362Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201715,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleb, osadów ściekowych","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"},{"codes":"P/31","pl":"Pobieranie próbek gleb do badań chemicznych","en":"Sampling soil for chemical tests"},{"codes":"P/32","pl":"Pobieranie próbek osadów ściekowych do badań chemicznych, mikrobiologicznych i biologicznych","en":"Sampling sediments for chemical, microbiological and biological tests"}],"issue":{"no":"8","date":"22.04.2026"},"parse_date":"2026-08-17T11:22:28.362Z","parse_source":"agent-claude-code","map_coord":[53.244437,19.392197],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":"ul. Ustronie 20A","city":"Brodnica","postal":"87-300"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/d30a183de949a3d997b84c24b6e2b0a4/AB%201715.pdf","has_en":true,"category_counts":{"water":35,"microbiology":4,"environment":2},"category_scores":{"water":29.88,"microbiology":0.39,"environment":0.1},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":"ul. Ustronie 20A","city":"Brodnica","postal":"87-300"}]},"methods":[{"_id":"6a82eef4884ede9a1b2c4b0d","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wylaczeniem p. 5.2, 6.1.2, 6.2, 6.3","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Laboratory PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 实验室 PN-ISO 5667-11:2017-10 z wyłączeniem p. 5.2, 6.1.2, 6.2, 6.3","test_object_zh":"水"},{"_id":"6a82eef4884ede9a1b2c4b0e","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a82eef4884ede9a1b2c4b0f","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Temperatura","range":"Zakres: (5,0 – 55,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres: Zakres: (5,0 – 55,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres: Zakres: (5,0 – 55,0) °C PN-77/C-04584 Woda do spozycia przez ludzi Temperatura\nZakres: Zakres: (5,0 – 55,0) °C PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Temperature","range":"Zakres: (5,0 – 55,0) °C"}],"search_en":"Water intended for human consumption Temperature Laboratory Temperature PN-77/C-04584","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","search_zh":"生活饮用水 温度 实验室 温度 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"温度","parameters_zh":[{"name":"温度","range":"Zakres: (5,0 – 55,0) °C"}]},{"_id":"6a82eef4884ede9a1b2c4b10","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a82eef4884ede9a1b2c4b11","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki, Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater, Rainwater and snowmelt water Sampling for chemical and physical testing Manual method; Automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater, Rainwater and snowmelt water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"废水、雨水与融雪水 化学与物理检测用样品采集 手动法；自动法 实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"废水、雨水与融雪水"},{"_id":"6a82eef4884ede9a1b2c4b12","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki, Wody opadowe i roztopowe","methodology":"Temperatura","parameters":[{"name":"Temperatura","range":"Zakres: (5,0 – 55,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres: Zakres: (5,0 – 55,0) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Wody opadowe i roztopowe Temperatura\nZakres: Zakres: (5,0 – 55,0) °C PN-77/C-04584 Scieki, Wody opadowe i roztopowe Temperatura\nZakres: Zakres: (5,0 – 55,0) °C PN-77/C-04584","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Temperature","parameters_en":[{"name":"Temperature","range":"Zakres: (5,0 – 55,0) °C"}],"search_en":"Wastewater, Rainwater and snowmelt water Temperature Laboratory Temperature PN-77/C-04584","test_object_en":"Wastewater, Rainwater and snowmelt water","lab_section_zh":"实验室","search_zh":"废水、雨水与融雪水 温度 实验室 温度 PN-77/C-04584","methodology_zh":"温度","parameters_zh":[{"name":"温度","range":"Zakres: (5,0 – 55,0) °C"}],"test_object_zh":"废水、雨水与融雪水"},{"_id":"6a82eef4884ede9a1b2c4b13","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997","norm_bases":["PN-R-04031:1997"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing Laboratory PN-R-04031:1997","test_object_en":"Soil","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 实验室 PN-R-04031:1997","test_object_zh":"土壤"},{"_id":"6a82eef4884ede9a1b2c4b14","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, mikrobiologicznych, biologicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, mikrobiologicznych, biologicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, mikrobiologicznych, biologicznych i fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, mikrobiologicznych, biologicznych i fizycznych PN-EN ISO 5667-13:2011","categories":["water","microbiology"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical, microbiological, biological and physical testing","search_en":"Sewage sludge Sampling for chemical, microbiological, biological and physical testing Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a82eef4884ede9a1b2c4b15","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"pH","range":"Zakres: 2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"pH","range":"Zakres: 2,0 – 10,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Laboratory pH PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"pH 值","range":"Zakres: 2,0 – 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 实验室 pH 值 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a82eef4884ede9a1b2c4b16","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Stężenie azotynów","range":"Zakres: (0,030 – 200,0) mg/l"},{"name":"Stężenie azotu azotynowego","range":"Zakres: (0,009 – 60,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nStężenie azotynów Zakres: (0,030 – 200,0) mg/l\nStężenie azotu azotynowego Zakres: (0,009 – 60,9) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres:\nStężenie azotynów Zakres: (0,030 – 200,0) mg/l\nStężenie azotu azotynowego Zakres: (0,009 – 60,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres:\nStezenie azotynow Zakres: (0,030 – 200,0) mg/l\nStezenie azotu azotynowego Zakres: (0,009 – 60,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Nitrite concentration","range":"Zakres: (0,030 – 200,0) mg/l"},{"name":"Nitrite nitrogen concentration","range":"Zakres: (0,009 – 60,9) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Laboratory Nitrite concentration Nitrite nitrogen concentration PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"亚硝酸盐浓度","range":"Zakres: (0,030 – 200,0) mg/l"},{"name":"亚硝态氮浓度","range":"Zakres: (0,009 – 60,9) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 实验室 亚硝酸盐浓度 亚硝态氮浓度 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a82eef4884ede9a1b2c4b17","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Stężenie azotanów","range":"Zakres: (0,20 – 130,0) mg/l"},{"name":"Stężenie azotu azotanowego","range":"Zakres: (0,05 – 29,4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nStężenie azotanów Zakres: (0,20 – 130,0) mg/l\nStężenie azotu azotanowego Zakres: (0,05 – 29,4) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres:\nStężenie azotanów Zakres: (0,20 – 130,0) mg/l\nStężenie azotu azotanowego Zakres: (0,05 – 29,4) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres:\nStezenie azotanow Zakres: (0,20 – 130,0) mg/l\nStezenie azotu azotanowego Zakres: (0,05 – 29,4) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Nitrate concentration","range":"Zakres: (0,20 – 130,0) mg/l"},{"name":"Nitrate nitrogen concentration","range":"Zakres: (0,05 – 29,4) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Laboratory Nitrate concentration Nitrate nitrogen concentration PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"硝酸盐浓度","range":"Zakres: (0,20 – 130,0) mg/l"},{"name":"硝态氮浓度","range":"Zakres: (0,05 – 29,4) mg/l"}],"search_zh":"水、生活饮用水、废水 硝酸盐浓度 分光光度法 实验室 硝酸盐浓度 硝态氮浓度 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a82eef4884ede9a1b2c4b18","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Stężenie chlorków","range":"Zakres: (5 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres: Zakres: (5 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres: Zakres: (5 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres: Zakres: (5 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Chloride concentration","range":"Zakres: (5 – 1000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Laboratory Chloride concentration PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"氯化物浓度","range":"Zakres: (5 – 1000) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 实验室 氯化物浓度 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a82eef4884ede9a1b2c4b19","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Stężenie siarczanów","range":"Zakres: (10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres: Zakres: (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres: Zakres: (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres: Zakres: (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Sulfate concentration","range":"Zakres: (10 – 1000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Gravimetric method Laboratory Sulfate concentration PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"硫酸盐浓度","range":"Zakres: (10 – 1000) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 重量法 实验室 硫酸盐浓度 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a82eef4884ede9a1b2c4b1a","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZTCr","parameters":[{"name":"ChZTCr","range":"Zakres: (5,0 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (5,0 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (5,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (5,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand - CODCr","parameters_en":[{"name":"CODCr","range":"Zakres: (5,0 – 150) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - CODCr Spectrophotometric method Laboratory CODCr PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","search_zh":"水、污水 分光光度法 实验室 COD-Cr PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","parameters_zh":[{"name":"COD-Cr","range":"Zakres: (5,0 – 150) mg/l O2"}]},{"_id":"6a82eef4884ede9a1b2c4b1b","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"BZT5","range":"Zakres: (1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"BOD5","range":"Zakres: (1,0 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory BOD5 PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"BZT5（BOD5）","range":"Zakres: (1,0 – 6,0) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 实验室 BZT5（BOD5） PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82eef4884ede9a1b2c4b1c","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zawiesiny ogólne","range":"Zakres (2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres: Zakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki, Wody opadowe i roztopowe Zawiesiny ogólne\nZakres: Zakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki, Wody opadowe i roztopowe Zawiesiny ogolne\nZakres: Zakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Total suspended solids (TSS)","range":"Zakres (2,0 – 5000) mg/l"}],"search_en":"Water, Wastewater, Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Laboratory Total suspended solids (TSS) PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater, Rainwater and snowmelt water","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"总悬浮物","range":"Zakres (2,0 – 5000) mg/l"}],"search_zh":"水、废水、雨水与融雪水 总悬浮物 重量法 实验室 总悬浮物 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水、雨水与融雪水"},{"_id":"6a82eef4884ede9a1b2c4b1d","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"BZT5","range":"Zakres: (3,0 – 9000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (3,0 – 9000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (3,0 – 9000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nBZT5 Zakres: (3,0 – 9000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"BOD5","range":"Zakres: (3,0 – 9000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Laboratory BOD5 PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"BZT5（BOD5）","range":"Zakres: (3,0 – 9000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 实验室 BZT5（BOD5） PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a82eef4884ede9a1b2c4b1e","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZTCr","parameters":[{"name":"ChZTCr","range":"Zakres: (20,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZTCr\nChZTCr Zakres: (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand - CODCr","parameters_en":[{"name":"CODCr","range":"Zakres: (20,0 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - CODCr Spectrophotometric method Laboratory CODCr PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","search_zh":"污水 分光光度法 实验室 COD-Cr PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","parameters_zh":[{"name":"COD-Cr","range":"Zakres: (20,0 – 10000) mg/l O2"}]},{"_id":"6a82eef4884ede9a1b2c4b1f","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Stężenie fosforu ogólnego","range":"Zakres: (0,10 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres: Zakres: (0,10 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres: Zakres: (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres: Zakres: (0,10 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Total phosphorus concentration","range":"Zakres: (0,10 – 100) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Total phosphorus concentration PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"总磷浓度","range":"Zakres: (0,10 – 100) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 总磷浓度 PN-EN ISO 6878:2006 p. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a82eef4884ede9a1b2c4b20","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Stężenie azotu amonowego","range":"Zakres: (1,0 – 1000,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Ammonium nitrogen concentration","range":"Zakres: (1,0 – 1000,0) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Ammonium nitrogen concentration PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"氨氮浓度","range":"Zakres: (1,0 – 1000,0) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 氨氮浓度 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a82eef4884ede9a1b2c4b21","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Stężenie azotu Kjeldahla","range":"Zakres: (1,0 – 1000,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres: Zakres: (1,0 – 1000,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Kjeldahl nitrogen concentration","range":"Zakres: (1,0 – 1000,0) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Kjeldahl nitrogen concentration PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"凯氏氮浓度","range":"Zakres: (1,0 – 1000,0) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 实验室 凯氏氮浓度 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a82eef4884ede9a1b2c4b22","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) Laboratory PN-73/C-04576/14","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） 实验室 PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a82eef4884ede9a1b2c4b23","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zawiesiny łatwoopadające","range":"Zakres: (0,5 – 200) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres: Zakres: (0,5 – 200) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny łatwoopadające\nZakres: Zakres: (0,5 – 200) ml/l\nMetoda objętościowa PN-72/C-04559/03 Scieki Zawiesiny latwoopadajace\nZakres: Zakres: (0,5 – 200) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Settleable solids","parameters_en":[{"name":"Settleable solids","range":"Zakres: (0,5 – 200) ml/l"}],"search_en":"Wastewater Settleable solids Volumetric method Laboratory Settleable solids PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","search_zh":"污水 易沉降悬浮物 容量法 实验室 易沉降悬浮物 PN-72/C-04559/03","test_object_zh":"污水","technique_zh":"容量法","methodology_zh":"易沉降悬浮物","parameters_zh":[{"name":"易沉降悬浮物","range":"Zakres: (0,5 – 200) ml/l"}]},{"_id":"6a82eef4884ede9a1b2c4b24","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Gleba, Osady ściekowe","methodology":"pH w H2O","parameters":[{"name":"pH w H2O","range":"Zakres: 2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w H2O\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, Osady ściekowe pH w H2O\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba, Osady sciekowe pH w H2O\nZakres: Zakres: 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water","environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH in H2O","parameters_en":[{"name":"pH in H2O","range":"Zakres: 2,0 – 10,0"}],"search_en":"Soil, Sewage sludge pH in H2O Potentiometric method Laboratory pH in H2O PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil, Sewage sludge","lab_section_zh":"实验室","methodology_zh":"水中 pH 值","parameters_zh":[{"name":"水中 pH 值","range":"Zakres: 2,0 – 10,0"}],"search_zh":"土壤、污泥 水中 pH 值 电位法 实验室 水中 pH 值 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤、污泥"},{"_id":"6a82eef4884ede9a1b2c4b25","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Sucha pozostałość","range":"Zakres: (1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady sciekowe Sucha pozostalosc\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Dry residue","range":"Zakres: (1,0 – 99,0) %"}],"search_en":"Sewage sludge Dry residue Gravimetric method Laboratory Dry residue PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 干残渣 重量法 实验室 干残渣 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣","parameters_zh":[{"name":"干残渣","range":"Zakres: (1,0 – 99,0) %"}]},{"_id":"6a82eef4884ede9a1b2c4b26","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość wody (z obliczeń)","parameters":[{"name":"Zawartość wody","range":"Zakres: (1,0 – 99,0) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)\nZawartość wody Zakres: (1,0 – 99,0) %","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość wody (z obliczeń)\nZawartość wody Zakres: (1,0 – 99,0) % PN-EN 15934:2013-02 metoda A Osady sciekowe Zawartosc wody (z obliczen)\nZawartosc wody Zakres: (1,0 – 99,0) % PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Water content (calculated)","parameters_en":[{"name":"Water content","range":"Zakres: (1,0 – 99,0) %"}],"search_en":"Sewage sludge Water content (calculated) Laboratory Water content PN-EN 15934:2013-02 metoda A","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"水分含量","range":"Zakres: (1,0 – 99,0) %"}],"search_zh":"污泥 水分含量（计算值） 实验室 水分含量 PN-EN 15934:2013-02 metoda A","test_object_zh":"污泥","methodology_zh":"水分含量（计算值）"},{"_id":"6a82eef4884ede9a1b2c4b27","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu","parameters":[{"name":"Straty przy prażeniu","range":"Zakres: (1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu\nZakres: Zakres: (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Loss on ignition","parameters_en":[{"name":"Loss on ignition","range":"Zakres: (1,0 – 99,0) %"}],"search_en":"Sewage sludge Loss on ignition Gravimetric method Laboratory Loss on ignition PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 烧失量 重量法 实验室 烧失量 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"烧失量","parameters_zh":[{"name":"烧失量","range":"Zakres: (1,0 – 99,0) %"}]},{"_id":"6a82eef4884ede9a1b2c4b28","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pozostałość po prażeniu (z obliczeń)","parameters":[{"name":"Pozostałość po prażeniu","range":"Zakres: (1,0 – 99,0) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Pozostałość po prażeniu (z obliczeń)\nPozostałość po prażeniu Zakres: (1,0 – 99,0) %","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pozostałość po prażeniu (z obliczeń)\nPozostałość po prażeniu Zakres: (1,0 – 99,0) % PN-EN 15935:2022-01 Osady sciekowe Pozostalosc po prazeniu (z obliczen)\nPozostalosc po prazeniu Zakres: (1,0 – 99,0) % PN-EN 15935:2022-01","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Residue on ignition (calculated)","parameters_en":[{"name":"Residue on ignition","range":"Zakres: (1,0 – 99,0) %"}],"search_en":"Sewage sludge Residue on ignition (calculated) Laboratory Residue on ignition PN-EN 15935:2022-01","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 实验室 灼烧残渣 PN-EN 15935:2022-01","test_object_zh":"污泥","parameters_zh":[{"name":"灼烧残渣","range":"Zakres: (1,0 – 99,0) %"}]},{"_id":"6a82eef4884ede9a1b2c4b29","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego zapachu ☑","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Obecność obcego zapachu ☑\nMetoda jakościowa","reference":"PN-EN 1622:2006 Annex C","norm_bases":["PN-EN 1622:2006 Annex C"],"lab_section":"Laboratorium; ☑ Badania wykonywane poza siedzibą Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu ☑\nMetoda jakościowa PN-EN 1622:2006 Annex C Woda do spozycia przez ludzi Obecnosc obcego zapachu ☑\nMetoda jakosciowa PN-EN 1622:2006 Annex C","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Qualitative method PN-EN 1622:2006 Annex C","technique_en":"Qualitative method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 定性法 PN-EN 1622:2006 Annex C","test_object_zh":"生活饮用水","technique_zh":"定性法"},{"_id":"6a82eef4884ede9a1b2c4b2a","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Liczba progowa zapachu TON","range":"Zakres: 1"}],"technique":"Metoda ilościowa uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda ilościowa uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres: Zakres: 1\nMetoda ilościowa uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres: Zakres: 1\nMetoda ilościowa uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres: Zakres: 1\nMetoda ilosciowa uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Odour threshold number TON","range":"Zakres: 1"}],"search_en":"Water intended for human consumption Odour threshold number TON Laboratory Odour threshold number TON PN-EN 1622:2006","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","search_zh":"生活饮用水 嗅阈值 TON 实验室 嗅阈值 TON PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"嗅阈值 TON","parameters_zh":[{"name":"嗅阈值 TON","range":"Zakres: 1"}]},{"_id":"6a82eef4884ede9a1b2c4b2b","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego smaku ☑","parameters":[],"technique":"Metoda jakościowa","techniques":["Metoda jakościowa"],"computed":[],"activity":"Obecność obcego smaku ☑\nMetoda jakościowa","reference":"PN-EN 1622:2006 Annex C","norm_bases":["PN-EN 1622:2006 Annex C"],"lab_section":"Laboratorium; ☑ Badania wykonywane poza siedzibą Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku ☑\nMetoda jakościowa PN-EN 1622:2006 Annex C Woda do spozycia przez ludzi Obecnosc obcego smaku ☑\nMetoda jakosciowa PN-EN 1622:2006 Annex C","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Qualitative method PN-EN 1622:2006 Annex C","technique_en":"Qualitative method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 定性法 PN-EN 1622:2006 Annex C","test_object_zh":"生活饮用水","technique_zh":"定性法"},{"_id":"6a82eef4884ede9a1b2c4b2c","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Liczba progowa smaku TFN","range":"Zakres: 1"}],"technique":"Metoda ilościowa uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda ilościowa uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres: Zakres: 1\nMetoda ilościowa uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres: Zakres: 1\nMetoda ilościowa uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres: Zakres: 1\nMetoda ilosciowa uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Taste threshold number TFN","range":"Zakres: 1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Laboratory Taste threshold number TFN PN-EN 1622:2006","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","search_zh":"生活饮用水 味阈值 TFN 实验室 味阈值 TFN PN-EN 1622:2006","test_object_zh":"生活饮用水","methodology_zh":"味阈值 TFN","parameters_zh":[{"name":"味阈值 TFN","range":"Zakres: 1"}]},{"_id":"6a82eef4884ede9a1b2c4b2d","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） 实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a82eef4884ede9a1b2c4b2e","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, Water intended for human consumption Most probable number of Escherichia coli MPN method Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） 实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a82eef4884ede9a1b2c4b2f","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba enterokoków","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL","reference":"PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW","norm_bases":["PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba enterokoków\nMetoda NPL PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba enterokokow\nMetoda NPL PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number of enterococci","search_en":"Water, Water intended for human consumption Most probable number of enterococci MPN method Laboratory PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","search_zh":"水、生活饮用水 肠球菌最可能数 最可能数法（MPN） 实验室 PB-02 wyd. 1 z dnia 01.10.2024 r. na podstawie instrukcji testu IDEXX Enterolert-DW","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌最可能数"},{"_id":"6a82eef4884ede9a1b2c4b30","lab_id":"69ad52a3de79e566650fb90b","country":"PL","accr_number":"AB 1715","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 22 oC","search_en":"Water, Water intended for human consumption Total viable count at 22 oC Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"}],"has_pdf":true}