🇵🇱 SPIE ENERGY POLAND S.A. PL

PCA AB 1712 • Gdańsk, Poland • 10 methods

EnvironmentElectronics & EMC

SPIE ENERGY POLAND S.A. is a laboratory accredited by PCA under number AB 1712 (Gdańsk, Poland). Its accreditation scope covers 10 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field in the workspace duri…, General environment – noise from installations, equipment and indus…, Workplace environment – noise. Most frequently used techniques: Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1712
  • Methods in scope: 10
  • Types of test objects: 4
  • Techniques used: 1
  • City: Gdańsk, Poland
Accreditation number
AB 1712
Accreditation body
PCA
Address
LABORATORIUM BADAWCZE, ul. Marynarki Polskiej 87, 80-557 Gdańsk
City
Gdańsk, Poland

What this laboratory tests (4)

Analytical techniques used (1)

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Electric field strength in the frequency range:
45 Hz – 55 Hz Range (1 –40 000) V/m
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
2 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic flux density in the frequency range:
45 Hz – 55 Hz Range 0,5 μT – 19 mT
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
3 Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry Magnetic field strength (calculated) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
4 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength
in the frequency range 50 Hz Range (100 –40 000) V/m
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630)
5 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density
in the frequency range 50 Hz Range (0,5 – 19 000) μT
Direct measurement method Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630)
6 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength
in the frequency range 50 Hz (calculated)
Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630)
7 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 136) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F
8 General environment – noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F
9 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 – 136) dB C-weighted peak sound pressure level Range (35 –140) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11
10 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11

Reference standards (5)

PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11
PN-N-01307:1994
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630)
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F