🇵🇱 SPIE ENERGY POLAND S.A. PL
EnvironmentElectronics & EMC
SPIE ENERGY POLAND S.A. is a laboratory accredited by PCA under number AB 1712 (Gdańsk, Poland). Its accreditation scope covers 10 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field in the workspace duri…, General environment – noise from installations, equipment and indus…, Workplace environment – noise. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 1712
- Methods in scope: 10
- Types of test objects: 4
- Techniques used: 1
- City: Gdańsk, Poland
- Accreditation number
- AB 1712
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Marynarki Polskiej 87, 80-557 Gdańsk
- City
- Gdańsk, Poland
What this laboratory tests (4)
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 3 methods
- Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 methods
- General environment – noise from installations, equipment and industrial plants — 2 methods
- Workplace environment – noise — 2 methods
Analytical techniques used (1)
- Direct measurement method — 6 methods
Accreditation scope — test methods (10)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Electric field strength in the frequency range: 45 Hz – 55 Hz Range (1 –40 000) V/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
| 2 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic flux density in the frequency range: 45 Hz – 55 Hz Range 0,5 μT – 19 mT |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
| 3 | Workplace environment – electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | Magnetic field strength (calculated) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | ||
| 4 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength in the frequency range 50 Hz Range (100 –40 000) V/m |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630) | |
| 5 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic flux density in the frequency range 50 Hz Range (0,5 – 19 000) μT |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630) | |
| 6 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength in the frequency range 50 Hz (calculated) |
Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630) | ||
| 7 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 136) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F | |
| 8 | General environment – noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F | ||
| 9 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (25 – 136) dB C-weighted peak sound pressure level Range (35 –140) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11 | |
| 10 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11 | ||
Reference standards (5)
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - punkt 10 i strategię 3 punkt 11
PN-N-01307:1994
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
Załącznik do rozporządzenia Ministra Klimatu z dnia 17 lutego 2020 r. (t.j. Dz. U. 2022 poz. 2630)
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem pkt. F