🇵🇱 Strzelec Paweł Świętokrzyskie Centrum BHP PL
EnvironmentConstruction
Strzelec Paweł Świętokrzyskie Centrum BHP is a laboratory accredited by PCA under number AB 1695 (Skarżysko-Kamienna, Poland). Its accreditation scope covers 29 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment – air, General environment − noise from installations, equipment and indus…, Workplace environment – cold microclimate, Workplace environment – energy expenditure. Most frequently used techniques: Direct measurement method, Gravimetric method, Personal dosimetry method.
At a glance
- Accreditation number: PCA AB 1695
- Methods in scope: 29
- Types of test objects: 12
- Techniques used: 5
- City: Skarżysko-Kamienna, Poland
- Accreditation number
- AB 1695
- Accreditation body
- PCA
- Address
- Laboratorium Badań Środowiska Pracy, ul. Ks. J. Popiełuszki 18, 26-110 Skarżysko-Kamienna
- City
- Skarżysko-Kamienna, Poland
What this laboratory tests (12)
- Workplace environment – air — 8 methods
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – energy expenditure — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – noise — 2 methods
- Workplace environment – noise (selection of hearing protectors) — 2 methods
- Workplace environment – whole-body vibration — 2 methods
- Rooms in residential, collective residence and public utility buildings – air — 1 method
Analytical techniques used (5)
- Direct measurement method — 10 methods
- Gravimetric method — 2 methods
- Personal dosimetry method — 2 methods
- Electrochemical method — 1 method
- Stationary method — 1 method
Laboratory locations
- Laboratorium Badań Środowiska Pracy — ul. Ks. J. Popiełuszki 18
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Workplace Environment Testing Laboratory | |||||
| 1 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (25 – 136) dB C-weighted peak sound pressure level Range (25 – 136) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | |
| 2 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | ||
| 3 | Workplace environment – noise (selection of hearing protectors) | Equivalent sound pressure level in octave frequency bands Range (63 – 8000) Hz Range (25 – 136) dB |
Direct measurement method | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | |
| 4 | Workplace environment – noise (selection of hearing protectors) | A-weighted equivalent sound level under hearing protectors (calculated) | PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 | ||
| 5 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 136) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1. | |
| 6 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1. | ||
| 7 | Workplace environment – indoor electric lighting | Illuminance Range (0,5 – 10000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 8 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated), Illuminance uniformity | PN-83/E-04040.03 | ||
| 9 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,23 – 20) m/s2 |
Direct measurement method | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | |
| 10 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) | PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 11 | Workplace environment – whole-body vibration | Frequency-weighted r.m.s. vibration acceleration Range (0,03 – 35) m/s2 |
Direct measurement method | PN-EN 14253+A1:2011 | |
| 12 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) | PN-EN 14253+A1:2011 | ||
| 13 | Workplace environment – energy expenditure | Air temperature Range (5 – 40) °C Air flow Range (10 – 60) dm3/min |
Direct measurement method | KT 5.2 wydanie z dnia 30.05.2025 r. | |
| 14 | Workplace environment – energy expenditure | Energy expenditure (calculated) | KT 5.2 wydanie z dnia 30.05.2025 r. | ||
| 15 | Workplace environment – cold microclimate | Air temperature Range (-30,0 – 10,0) °C Black globe temperature Range (-20,0 – 15,0) °C Air humidity Range (10,0 – 85) % Air velocity Range (0,15 – 5,0) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 16 | Workplace environment – cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 17 | Workplace environment – hot microclimate | Air temperature Range (15,0 – 60,0) °C Natural wet bulb temperature Range (10,0 – 60,0) °C Black globe temperature Range (15,0 – 60,0) °C |
Direct measurement method | PN-EN ISO 7243:2018-01 | |
| 18 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | ||
| 19 | Workplace environment – moderate microclimate | Air temperature Range (10,0 – 30,0) °C Black globe temperature Range (10,0 – 35,0) °C Air humidity Range (10,0 – 90,0) % Air velocity Range (0,15 – 1,0) m/s |
Direct measurement method | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | |
| 20 | Workplace environment – moderate microclimate | PMV index, PPD index (calculated) | PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 21 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 22 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 23 | Workplace environment – air | Sampling for the assessment of occupational exposure to: asbestos – respirable fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres silicon carbide, fibrous – respirable fibres |
Personal dosimetry method | PN-Z-04008-7:2002 | PN-Z-04202-02:1988 | |
| 24 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002 | PN-Z-04202-02:1988 | ||
| 25 | Workplace environment – air | Concentration of harmful dust agents - inhalable fraction: Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,16 – 16,6) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 | |
| 26 | Workplace environment – air | Concentration of harmful dust agents - respirable fraction: Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,10 – 6,3) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 | |
| 27 | Workplace environment – air | Carbon monoxide concentration Range (2,3 – 232) mg/m3 Range (2 – 200) ppm |
Electrochemical method | KT 6.2 wydanie z dnia 12.04.2021 r. | |
| 28 | Workplace environment – air | Exposure indices (calculated) | KT 6.2 wydanie z dnia 12.04.2021 r. | ||
| 29 | Rooms in residential, collective residence and public utility buildings – air | Sampling for the determination of organic compound concentration | Stationary method | KT 11.1 wydanie z dnia 1.03.2021 r. | |
Reference standards (24)
KT 11.1 wydanie z dnia 1.03.2021 r.
KT 5.2 wydanie z dnia 30.05.2025 r.
KT 6.2 wydanie z dnia 12.04.2021 r.
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 458:2016-06
PN-EN ISO 11079:2008
PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04202-02:1988
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.