{"lab":{"_id":"69ad52a3de79e566650fb8ed","accr_number":"AB 1695","country":"PL","accr_body":"PCA","address":"Laboratorium Badań Środowiska Pracy, ul. Ks. J. Popiełuszki 18, 26-110 Skarżysko-Kamienna","categories":["environment","construction"],"city":"Skarżysko-Kamienna","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"Strzelec Paweł Świętokrzyskie Centrum BHP","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1695.pdf"],"scope_summary":"","search_text":"strzelec paweł świętokrzyskie centrum bhp laboratorium badań środowiska pracy, ul. ks. j. popiełuszki 18, 26-110 skarżysko-kamienna environment metrology pharma electronics other materials construction","status":"active","updated_at":"2026-03-08T14:50:49.477Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:03:01.270Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201695,podmiot.html","parse_date":"2026-08-13T08:03:01.270Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, drgania, mikroklimat, oświetlenie, wydatek energetyczny, środki ochrony osobistej)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, vibration, lighting, microclimate, energy expenditure, personal protection equipment)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"},{"codes":"P/35","pl":"Pobieranie próbek – pomieszczenia (czynniki szkodliwe – powietrze)","en":"Sampling – facilities (harmful factors – air)"}],"issue":{"no":"11","date":"10.08.2026"},"map_coord":[51.113882,20.857883],"map_geo":"nominatim-city","lab_locations":[{"name":"Laboratorium Badań Środowiska Pracy","address":"ul. Ks. J. Popiełuszki 18","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/5ddfccf6aed1447169a7b03d86720cb0/AB%201695.pdf","has_en":true,"category_counts":{"environment":29,"construction":2,"materials":1},"category_scores":{"environment":26.28,"construction":0.13,"materials":0.03},"has_zh":true,"lab_locations_zh":[{"name":"工作场所环境检测实验室","address":"ul. Ks. J. Popiełuszki 18","city":null,"postal":null}]},"methods":[{"_id":"6a7d7a350636ba417e41b2cd","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 136) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(25 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dźwięku C\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (25 – 136) dB\nSzczytowy poziom dzwieku C\nZakres (25 – 136) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(25 – 136) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(25 – 136) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Workplace Environment Testing Laboratory Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(25 – 136) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(25 – 136) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 工作场所环境检测实验室 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2ce","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8-godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment – noise Noise exposure level referred to: Workplace Environment Testing Laboratory an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 工作场所环境检测实验室 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2cf","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – hałas (dobór ochronników słuchu)","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych","parameters":[{"name":"Zakres","range":"(63 – 8000) Hz"},{"name":"Zakres","range":"(25 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych\nZakres:\nZakres (63 – 8000) Hz\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas (dobór ochronników słuchu) Równoważny poziom ciśnienia akustycznego w pasmach częstotliwościowych oktawowych\nZakres:\nZakres (63 – 8000) Hz\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas (dobor ochronnikow sluchu) Rownowazny poziom cisnienia akustycznego w pasmach czestotliwosciowych oktawowych\nZakres:\nZakres (63 – 8000) Hz\nZakres (25 – 136) dB\nMetoda pomiarowa bezposrednia PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wylaczeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Equivalent sound pressure level in octave frequency bands","parameters_en":[{"name":"Range","range":"(63 – 8000) Hz"},{"name":"Range","range":"(25 – 136) dB"}],"search_en":"Workplace environment – noise (selection of hearing protectors) Equivalent sound pressure level in octave frequency bands Direct measurement method Workplace Environment Testing Laboratory Range Range PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise (selection of hearing protectors)","parameters_zh":[{"name":"范围","range":"(63 – 8000) Hz"},{"name":"范围","range":"(25 – 136) dB"}],"search_zh":"工作环境 － 噪声（听力护具的选配） 倍频程频带等效声压级 直接测量法 工作场所环境检测实验室 范围 范围 PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"倍频程频带等效声压级","test_object_zh":"工作环境 － 噪声（听力护具的选配）"},{"_id":"6a7d7a350636ba417e41b2d0","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – hałas (dobór ochronników słuchu)","methodology":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń)","reference":"PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","norm_bases":["PN-EN 458:2016-06","PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR","PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas (dobór ochronników słuchu) Równoważny poziom dźwięku A pod ochronnikami słuchu (z obliczeń) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas (dobor ochronnikow sluchu) Rownowazny poziom dzwieku A pod ochronnikami sluchu (z obliczen) PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wylaczeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wylaczeniem metody obejmujacej strategie 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound level under hearing protectors (calculated)","search_en":"Workplace environment – noise (selection of hearing protectors) A-weighted equivalent sound level under hearing protectors (calculated) Workplace Environment Testing Laboratory PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise (selection of hearing protectors)","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作环境 － 噪声（听力护具的选配） 佩戴听力护具下的 A 计权等效声级（由计算得出） 工作场所环境检测实验室 PN-EN 458:2016-06 | PN-EN ISO 4869-2:2018-12 z wyłączeniem metod HML i SNR | PN-EN ISO 9612:2025-11 z wyłączeniem metody obejmującej strategię 2 i 3 - punkt 10 i 11","methodology_zh":"佩戴听力护具下的 A 计权等效声级（由计算得出）","test_object_zh":"工作环境 － 噪声（听力护具的选配）"},{"_id":"6a7d7a350636ba417e41b2d1","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 136) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1. Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 136) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F i E.II.1.","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 136) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Workplace Environment Testing Laboratory Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 136) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 工作场所环境检测实验室 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a7d7a350636ba417e41b2d2","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1. Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wylaczeniem punktu F i E.II.1.","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Workplace Environment Testing Laboratory Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） 工作场所环境检测实验室 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023, poz. 1706) z wyłączeniem punktu F i E.II.1.","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a7d7a350636ba417e41b2d3","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 10000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (0,5 – 10000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 10000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Workplace Environment Testing Laboratory Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 10000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 工作场所环境检测实验室 范围 PN-83/E-04040.03","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a7d7a350636ba417e41b2d4","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń), Równomierność oświetlenia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen), Rownomiernosc oswietlenia PN-83/E-04040.03","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Illuminance uniformity (calculated), Illuminance uniformity","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated), Illuminance uniformity Workplace Environment Testing Laboratory PN-83/E-04040.03","test_object_en":"Workplace environment – indoor electric lighting","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（由计算得出）、照度均匀度 工作场所环境检测实验室 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度均匀度（由计算得出）、照度均匀度"},{"_id":"6a7d7a350636ba417e41b2d5","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,23 – 20) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,23 – 20) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,23 – 20) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,23 – 20) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,23 – 20) m/s2"}],"search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Workplace Environment Testing Laboratory Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,23 – 20) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权振动加速度有效值 直接测量法 工作场所环境检测实验室 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2d6","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) Workplace Environment Testing Laboratory PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment – hand-arm vibration","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） 工作场所环境检测实验室 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）"},{"_id":"6a7d7a350636ba417e41b2d7","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 35) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 35) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 35) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 35) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 35) m/s2"}],"search_en":"Workplace environment – whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Workplace Environment Testing Laboratory Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment – whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 35) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 工作场所环境检测实验室 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2d8","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) Workplace Environment Testing Laboratory PN-EN 14253+A1:2011","test_object_en":"Workplace environment – whole-body vibration","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） 工作场所环境检测实验室 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a7d7a350636ba417e41b2d9","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5 – 40) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10 – 60) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5 – 40) °C\nPrzepływ powietrza\nZakres (10 – 60) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"KT 5.2 wydanie z dnia 30.05.2025 r.","norm_bases":["KT 5.2 wydanie z dnia 30.05.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 – 40) °C\nPrzepływ powietrza\nZakres (10 – 60) dm3/min\nMetoda pomiarowa bezpośrednia KT 5.2 wydanie z dnia 30.05.2025 r. Srodowisko pracy – wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5 – 40) °C\nPrzeplyw powietrza\nZakres (10 – 60) dm3/min\nMetoda pomiarowa bezposrednia KT 5.2 wydanie z dnia 30.05.2025 r.","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5 – 40) °C"},{"name":"Air flow"},{"name":"Range","range":"(10 – 60) dm3/min"}],"search_en":"Workplace environment – energy expenditure Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Air flow Range KT 5.2 wydanie z dnia 30.05.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment – energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5 – 40) °C"},{"name":"空气流量"},{"name":"范围","range":"(10 – 60) dm3/min"}],"search_zh":"工作场所环境 — 能量消耗 空气温度 直接测量法 工作场所环境检测实验室 范围 空气流量 范围 KT 5.2 wydanie z dnia 30.05.2025 r.","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a7d7a350636ba417e41b2da","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"KT 5.2 wydanie z dnia 30.05.2025 r.","norm_bases":["KT 5.2 wydanie z dnia 30.05.2025 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczeń) KT 5.2 wydanie z dnia 30.05.2025 r. Srodowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczen) KT 5.2 wydanie z dnia 30.05.2025 r.","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment – energy expenditure Energy expenditure (calculated) Workplace Environment Testing Laboratory KT 5.2 wydanie z dnia 30.05.2025 r.","test_object_en":"Workplace environment – energy expenditure","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值） 工作场所环境检测实验室 KT 5.2 wydanie z dnia 30.05.2025 r.","methodology_zh":"能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a7d7a350636ba417e41b2db","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 – 10,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-20,0 – 15,0) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(10,0 – 85) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) °C\nTemperatura poczernionej kuli\nZakres (-20,0 – 15,0) °C\nWilgotność powietrza\nZakres (10,0 – 85) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) °C\nTemperatura poczernionej kuli\nZakres (-20,0 – 15,0) °C\nWilgotność powietrza\nZakres (10,0 – 85) %\nPrędkość powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 – 10,0) °C\nTemperatura poczernionej kuli\nZakres (-20,0 – 15,0) °C\nWilgotnosc powietrza\nZakres (10,0 – 85) %\nPredkosc powietrza\nZakres (0,15 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 – 10,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-20,0 – 15,0) °C"},{"name":"Air humidity"},{"name":"Range","range":"(10,0 – 85) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 – 10,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-20,0 – 15,0) °C"},{"name":"空气湿度"},{"name":"范围","range":"(10,0 – 85) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a7d7a350636ba417e41b2dc","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","lab_section_zh":"工作场所环境检测实验室","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a7d7a350636ba417e41b2dd","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(15,0 – 60,0) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10,0 – 60,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(15,0 – 60,0) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (15,0 – 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 – 60,0) °C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (15,0 – 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 – 60,0) °C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (15,0 – 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 – 60,0) °C\nTemperatura poczernionej kuli\nZakres (15,0 – 60,0) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(15,0 – 60,0) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10,0 – 60,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(15,0 – 60,0) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(15,0 – 60,0) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10,0 – 60,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(15,0 – 60,0) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7a350636ba417e41b2de","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7a350636ba417e41b2df","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10,0 – 30,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10,0 – 35,0) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(10,0 – 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) °C\nWilgotność powietrza\nZakres (10,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) °C\nWilgotność powietrza\nZakres (10,0 – 90,0) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10,0 – 30,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 35,0) °C\nWilgotnosc powietrza\nZakres (10,0 – 90,0) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10,0 – 30,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10,0 – 35,0) °C"},{"name":"Air humidity"},{"name":"Range","range":"(10,0 – 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Workplace Environment Testing Laboratory Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10,0 – 30,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10,0 – 35,0) °C"},{"name":"空气湿度"},{"name":"范围","range":"(10,0 – 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 工作场所环境检测实验室 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","lab_section_zh":"工作场所环境检测实验室","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7a350636ba417e41b2e0","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) Workplace Environment Testing Laboratory PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） 工作场所环境检测实验室 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7a350636ba417e41b2e1","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method Workplace Environment Testing Laboratory dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction metals and their compounds, including – inhalable fraction – respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 工作场所环境检测实验室 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"}]},{"_id":"6a7d7a350636ba417e41b2e2","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) Workplace Environment Testing Laboratory PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 工作场所环境检测实验室 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2e3","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"azbest – włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne"},{"name":"węglik krzemu, włóknisty – włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu, włóknisty – włókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04202-02:1988","norm_bases":["PN-Z-04008-7:2002","PN-Z-04202-02:1988"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nazbest – włókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych – włókna respirabilne\nwęglik krzemu, włóknisty – włókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04202-02:1988 Srodowisko pracy – powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nazbest – wlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych – wlokna respirabilne\nweglik krzemu, wloknisty – wlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04202-02:1988","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"asbestos – respirable fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres"},{"name":"silicon carbide, fibrous – respirable fibres"}],"search_en":"Workplace environment – air Sampling for the assessment of occupational exposure to: Personal dosimetry method Workplace Environment Testing Laboratory asbestos – respirable fibres man-made mineral fibres, excluding refractory ceramic fibres – respirable fibres silicon carbide, fibrous – respirable fibres PN-Z-04008-7:2002 | PN-Z-04202-02:1988","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment – air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 工作场所环境检测实验室 石棉 — 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维 碳化硅，纤维状 － 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04202-02:1988","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","parameters_zh":[{"name":"石棉 — 呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外 － 呼吸性纤维"},{"name":"碳化硅，纤维状 － 呼吸性纤维"}]},{"_id":"6a7d7a350636ba417e41b2e4","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04202-02:1988","norm_bases":["PN-Z-04008-7:2002","PN-Z-04202-02:1988"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04202-02:1988 Srodowisko pracy – powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04202-02:1988","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment – air Exposure index (calculated) Workplace Environment Testing Laboratory PN-Z-04008-7:2002 | PN-Z-04202-02:1988","test_object_en":"Workplace environment – air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） 工作场所环境检测实验室 PN-Z-04008-7:2002 | PN-Z-04202-02:1988","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室"},{"_id":"6a7d7a350636ba417e41b2e5","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:","parameters":[{"name":"Asfalt naftowy"},{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,16 – 16,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,16 – 16,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,16 – 16,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna:\nZakres:\nAsfalt naftowy\nApatyty i fosforyty\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,16 – 16,6) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents - inhalable fraction:","parameters_en":[{"name":"Petroleum bitumen"},{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,16 – 16,6) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - inhalable fraction: Gravimetric method Workplace Environment Testing Laboratory Petroleum bitumen Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"石油沥青"},{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,16 – 16,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分： 重量法 工作场所环境检测实验室 石油沥青 磷灰石与磷块岩 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 可吸入组分："},{"_id":"6a7d7a350636ba417e41b2e6","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,10 – 6,3) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 6,3) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,10 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy – powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna:\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,10 – 6,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Concentration of harmful dust agents - respirable fraction:","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,10 – 6,3) mg/m3"}],"search_en":"Workplace environment – air Concentration of harmful dust agents - respirable fraction: Gravimetric method Workplace Environment Testing Laboratory Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,10 – 6,3) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分： 重量法 工作场所环境检测实验室 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分："},{"_id":"6a7d7a350636ba417e41b2e7","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 232) mg/m3"},{"name":"Zakres","range":"(2 – 200) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna","reference":"KT 6.2 wydanie z dnia 12.04.2021 r.","norm_bases":["KT 6.2 wydanie z dnia 12.04.2021 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna KT 6.2 wydanie z dnia 12.04.2021 r. Srodowisko pracy – powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 232) mg/m3\nZakres (2 – 200) ppm\nMetoda elektrochemiczna KT 6.2 wydanie z dnia 12.04.2021 r.","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 232) mg/m3"},{"name":"Range","range":"(2 – 200) ppm"}],"search_en":"Workplace environment – air Carbon monoxide concentration Electrochemical method Workplace Environment Testing Laboratory Range Range KT 6.2 wydanie z dnia 12.04.2021 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment – air","parameters_zh":[{"name":"范围","range":"(2,3 – 232) mg/m3"},{"name":"范围","range":"(2 – 200) ppm"}],"search_zh":"工作场所环境 — 空气 一氧化碳浓度 电化学法 工作场所环境检测实验室 范围 范围 KT 6.2 wydanie z dnia 12.04.2021 r.","technique_zh":"电化学法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"一氧化碳浓度"},{"_id":"6a7d7a350636ba417e41b2e8","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Środowisko pracy – powietrze","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"KT 6.2 wydanie z dnia 12.04.2021 r.","norm_bases":["KT 6.2 wydanie z dnia 12.04.2021 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – powietrze Wskaźniki narażenia (z obliczeń) KT 6.2 wydanie z dnia 12.04.2021 r. Srodowisko pracy – powietrze Wskazniki narazenia (z obliczen) KT 6.2 wydanie z dnia 12.04.2021 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment – air Exposure indices (calculated) Workplace Environment Testing Laboratory KT 6.2 wydanie z dnia 12.04.2021 r.","test_object_en":"Workplace environment – air","search_zh":"工作场所环境 — 空气 暴露指数（计算值） 工作场所环境检测实验室 KT 6.2 wydanie z dnia 12.04.2021 r.","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"工作场所环境检测实验室","methodology_zh":"暴露指数（计算值）"},{"_id":"6a7d7a350636ba417e41b2e9","lab_id":"69ad52a3de79e566650fb8ed","country":"PL","accr_number":"AB 1695","accr_body":"PCA","test_object":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – powietrze","methodology":"Pobieranie próbek do oznaczania stężenia związków organicznych","parameters":[],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia związków organicznych\nMetoda stacjonarna","reference":"KT 11.1 wydanie z dnia 1.03.2021 r.","norm_bases":["KT 11.1 wydanie z dnia 1.03.2021 r."],"lab_section":"Laboratorium Badań Środowiska Pracy","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i użyteczności publicznej – powietrze Pobieranie próbek do oznaczania stężenia związków organicznych\nMetoda stacjonarna KT 11.1 wydanie z dnia 1.03.2021 r. Pomieszczenia w budynkach mieszkalnych, zamieszkania zbiorowego i uzytecznosci publicznej – powietrze Pobieranie probek do oznaczania stezenia zwiazkow organicznych\nMetoda stacjonarna KT 11.1 wydanie z dnia 1.03.2021 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Workplace Environment Testing Laboratory","methodology_en":"Sampling for the determination of organic compound concentration","search_en":"Rooms in residential, collective residence and public utility buildings – air Sampling for the determination of organic compound concentration Stationary method Workplace Environment Testing Laboratory KT 11.1 wydanie z dnia 1.03.2021 r.","technique_en":"Stationary method","test_object_en":"Rooms in residential, collective residence and public utility buildings – air","lab_section_zh":"工作场所环境检测实验室","search_zh":"用于测定有机化合物浓度的采样 定点测定法 工作场所环境检测实验室 KT 11.1 wydanie z dnia 1.03.2021 r.","technique_zh":"定点测定法","methodology_zh":"用于测定有机化合物浓度的采样"}],"has_pdf":true}