🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ PL

PCA AB 1677 • Mielec, Poland • 61 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ is a laboratory accredited by PCA under number AB 1677 (Mielec, Poland). Its accreditation scope covers 61 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Water, wastewater, Sewage sludge, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1677
  • Methods in scope: 61
  • Types of test objects: 7
  • Techniques used: 15
  • City: Mielec, Poland
Accreditation number
AB 1677
Accreditation body
PCA
Address
SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Wolności 44, 39-300 Mielec, CENTRALNE LABORATORIUM, ul. Kilińskiego 94
City
Mielec, Poland

What this laboratory tests (7)

Analytical techniques used (15)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (61)

No. Test object Methodology / Parameters Technique Reference document
Wastewater Treatment Plant Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (5,0 – 50,0) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Chemical oxygen demand - COD- Cr
Range (100 – 10000) mg/l O2
Titrimetric method PN-ISO 6060:2006
3 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
4 Water, wastewater Ammonium nitrogen concentration
Range (0,01 – 100) mg/l
Spectrophotometric method PN-EN 7150-1:2002
5 Water, wastewater Nitrite nitrogen concentration
Range (0,004 – 20) mg/l
Spectrophotometric method PN-EN 26777:1999
6 Water, wastewater Nitrate nitrogen concentration
Range (0,1 – 20) mg/l
Spectrophotometric method PN-82/C-04576/08
7 Water, wastewater Kjeldahl nitrogen concentration
Range (1 – 200) mg/l
Titrimetric method PN-EN 25663:2001
8 Water, wastewater Total nitrogen concentration (calculated) PB-01 wydanie 4 z dnia 17.02.2025
9 Water, wastewater Total phosphorus concentration
Range (0,02 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
10 Water, wastewater Biochemical oxygen demand
BOD5 Range (2 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
11 Water, wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
12 Water, wastewater Chemical oxygen demand - COD- Cr
Range (10 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
13 Water, wastewater Total suspended solids (TSS)
Range (2 – 15000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
14 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
15 Water, wastewater Electrical conductivity
Range (100 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
16 Water, wastewater Metal concentrations
zinc (0,05 – 50) mg/l copper (0,02 – 20) mg/l nickel (0,1 – 20) mg/l cadmium (0,02 – 10) mg/l lead (0,1 – 50) mg/l iron (0,1 – 20) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002
17 Water, wastewater Concentration of substances extractable with petroleum ether
Range (5 – 500) mg/l
Gravimetric method PB-03 wydanie 2 z 05.02.2025
18 Water, wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
19 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011
20 Sewage sludge pH – in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
21 Sewage sludge Dry matter
Range (1,0 – 85,0) %
Gravimetric method PN-EN 15934:2013-02 metoda A
22 Sewage sludge Water content (calculated) PN-EN 15934:2013-02 metoda A
23 Sewage sludge Loss on ignition of dry matter, residue on ignition
Range (10,0 – 80,0) %
Gravimetric method PN-EN 15935:2013-02
24 Sewage sludge Metal content
zinc (15 – 5000) mg/kg copper (5 – 2000) mg/kg nickel (15 – 1000) mg/kg cadmium (5 – 1000) mg/kg lead (15 – 1500) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 | PN-EN 13346:2002
25 Sewage sludge Chromium content
Range (5,0 – 1000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 p.3 | PN-EN 13346:2002
26 Sewage sludge Metal content
calcium (1,0 – 50) % magnesium (0,10 – 5,0) %
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002
27 Sewage sludge Mercury content
Range (0,5 – 10,0) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07
28 Sewage sludge Total phosphorus content
Range (0,10 – 5,0) %
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002
29 Sewage sludge Kjeldahl nitrogen content
Range (0,50 – 10,0) %
Titrimetric method PN-EN 13342:2002
30 Sewage sludge Ammonium nitrogen content
Range (0,10 – 5,0) %
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
Water Treatment Plant Laboratory
31 Water intended for human consumption Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample
Range (0 – 35) °C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
32 Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
33 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
34 Water intended for human consumption Free chlorine concentration
Range (0,03 – 1,0) mg/l
Spectrophotometric method PB-06 wydanie 2 z 05.02.2025
35 Water Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample
Range (0 – 35) °C
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584
36 Water Odour threshold number TON
Range 1– 8
Full paired method, non-forced choice PN-EN 1622:2006
37 Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
38 Water, Water intended for human consumption pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
39 Water, Water intended for human consumption Electrical conductivity
Range (100 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
40 Water, Water intended for human consumption Turbidity
Range (0,20 – 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
41 Water, Water intended for human consumption Nitrate nitrogen concentration
Range (0,10 – 20,0) mg/l
Spectrophotometric method PN-82/C-04576.08
42 Water, Water intended for human consumption Nitrate concentration (calculated) PN-82/C-04576.08
43 Water, Water intended for human consumption Nitrite nitrogen concentration
Range (0,01 – 1,0) mg/l
Spectrophotometric method PN-EN 26777:1999
44 Water, Water intended for human consumption Nitrite concentration (calculated) PN-EN 26777:1999
45 Water, Water intended for human consumption Ammonium nitrogen concentration
Range (0,02 – 5,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
46 Water, Water intended for human consumption Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
47 Water, Water intended for human consumption Aluminium concentration
Range (0,04 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605.02
48 Water, Water intended for human consumption Iron concentration
Range (20 – 25000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap.1:2016-06
49 Water, Water intended for human consumption Manganese concentration
Range (15 – 5000) μg/l
Spectrophotometric method PN-92/C-04590/02
50 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (2,0 – 500) mg/l CaCO3
Titrimetric method P N - I S O 6059:1999
51 Water, Water intended for human consumption Permanganate index
Range (0,5 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
52 Water, Water intended for human consumption Chloride concentration
Range (5,0 – 250) mg/l
Titrimetric method PN-ISO 9297:1994
53 Water, Water intended for human consumption Colour
Range (5,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
54 Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
55 Water, Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
56 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
57 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
58 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
59 Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method PN-EN ISO 14189:2016-10
60 Wastewater Iron concentration
Range (20 – 25000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap.1:2016-06
61 Water, Water intended for human consumption, Wastewater Total organic carbon concentration (TOC)
Range (1,0 – 500) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999

Reference standards (49)

P N - I S O 6059:1999
PB-01 wydanie 4 z dnia 17.02.2025
PB-03 wydanie 2 z 05.02.2025
PB-06 wydanie 2 z 05.02.2025
PN-77/C-04584
PN-82/C-04576.08
PN-82/C-04576/08
PN-92/C-04590/02
PN-92/C-04605.02
PN-EN 1233:2000 p.3
PN-EN 13342:2002
PN-EN 13346:2002
PN-EN 14671:2007
PN-EN 1484:1999
PN-EN 15934:2013-02 metoda A
PN-EN 15935:2013-02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 7150-1:2002
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap.1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002
PN-ISO 9280:2002
PN-ISO 9297:1994