🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ PL

PCA AB 1677 • Mielec, Poland • 61 methods

Water & wastewaterMicrobiology

MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ is a laboratory accredited by PCA under number AB 1677 (Mielec, Poland). Its accreditation scope covers 61 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Water, wastewater, Sewage sludge, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1677
  • Methods in scope: 61
  • Types of test objects: 7
  • Techniques used: 15
  • City: Mielec, Poland
Accreditation number
AB 1677
Accreditation body
PCA
Address
SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Wolności 44, 39-300 Mielec, CENTRALNE LABORATORIUM, ul. Kilińskiego 94
City
Mielec, Poland

What this laboratory tests (7)

Analytical techniques used (15)

Laboratory sections (2)

Laboratory locations

Certificate information

Issue date
24.03.2026
Issue no.
10

Accreditation scope — test methods (61)

No. Test object Methodology / Parameters Technique Reference document
Wastewater Treatment Plant Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (5,0 – 50,0) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Chemical oxygen demand - COD- Cr
Range (100 – 10000) mg/l O2
Titrimetric method PN-ISO 6060:2006
3 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
4 Water, wastewater Ammonium nitrogen concentration
Range (0,01 – 100) mg/l
Spectrophotometric method PN-EN 7150-1:2002
5 Water, wastewater Nitrite nitrogen concentration
Range (0,004 – 20) mg/l
Spectrophotometric method PN-EN 26777:1999
6 Water, wastewater Nitrate nitrogen concentration
Range (0,1 – 20) mg/l
Spectrophotometric method PN-82/C-04576/08
7 Water, wastewater Kjeldahl nitrogen concentration
Range (1 – 200) mg/l
Titrimetric method PN-EN 25663:2001
8 Water, wastewater Total nitrogen concentration (calculated) PB-01 wydanie 4 z dnia 17.02.2025
9 Water, wastewater Total phosphorus concentration
Range (0,02 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
10 Water, wastewater Biochemical oxygen demand
BOD5 Range (2 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
11 Water, wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
12 Water, wastewater Chemical oxygen demand - COD- Cr
Range (10 – 50000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
13 Water, wastewater Total suspended solids (TSS)
Range (2 – 15000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
14 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
15 Water, wastewater Electrical conductivity
Range (100 – 10000) μS/cm
Conductometric method PN-EN 27888:1999
16 Water, wastewater Metal concentrations
zinc (0,05 – 50) mg/l copper (0,02 – 20) mg/l nickel (0,1 – 20) mg/l cadmium (0,02 – 10) mg/l lead (0,1 – 50) mg/l iron (0,1 – 20) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002
17 Water, wastewater Concentration of substances extractable with petroleum ether
Range (5 – 500) mg/l
Gravimetric method PB-03 wydanie 2 z 05.02.2025
18 Water, wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
19 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011
20 Sewage sludge pH – in H2O
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10390:2022-09
21 Sewage sludge Dry matter
Range (1,0 – 85,0) %
Gravimetric method PN-EN 15934:2013-02 metoda A
22 Sewage sludge Water content (calculated) PN-EN 15934:2013-02 metoda A
23 Sewage sludge Loss on ignition of dry matter, residue on ignition
Range (10,0 – 80,0) %
Gravimetric method PN-EN 15935:2013-02
24 Sewage sludge Metal content
zinc (15 – 5000) mg/kg copper (5 – 2000) mg/kg nickel (15 – 1000) mg/kg cadmium (5 – 1000) mg/kg lead (15 – 1500) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 | PN-EN 13346:2002
25 Sewage sludge Chromium content
Range (5,0 – 1000) mg/kg
Flame atomic absorption spectrometry (FAAS) PN-EN 1233:2000 p.3 | PN-EN 13346:2002
26 Sewage sludge Metal content
calcium (1,0 – 50) % magnesium (0,10 – 5,0) %
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002
27 Sewage sludge Mercury content
Range (0,5 – 10,0) mg/kg
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07
28 Sewage sludge Total phosphorus content
Range (0,10 – 5,0) %
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002
29 Sewage sludge Kjeldahl nitrogen content
Range (0,50 – 10,0) %
Titrimetric method PN-EN 13342:2002
30 Sewage sludge Ammonium nitrogen content
Range (0,10 – 5,0) %
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
Water Treatment Plant Laboratory
31 Water intended for human consumption Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample
Range (0 – 35) °C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
32 Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
33 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
34 Water intended for human consumption Free chlorine concentration
Range (0,03 – 1,0) mg/l
Spectrophotometric method PB-06 wydanie 2 z 05.02.2025
35 Water Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample
Range (0 – 35) °C
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584
36 Water Odour threshold number TON
Range 1– 8
Full paired method, non-forced choice PN-EN 1622:2006
37 Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
38 Water, Water intended for human consumption pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
39 Water, Water intended for human consumption Electrical conductivity
Range (100 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
40 Water, Water intended for human consumption Turbidity
Range (0,20 – 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
41 Water, Water intended for human consumption Nitrate nitrogen concentration
Range (0,10 – 20,0) mg/l
Spectrophotometric method PN-82/C-04576.08
42 Water, Water intended for human consumption Nitrate concentration (calculated) PN-82/C-04576.08
43 Water, Water intended for human consumption Nitrite nitrogen concentration
Range (0,01 – 1,0) mg/l
Spectrophotometric method PN-EN 26777:1999
44 Water, Water intended for human consumption Nitrite concentration (calculated) PN-EN 26777:1999
45 Water, Water intended for human consumption Ammonium nitrogen concentration
Range (0,02 – 5,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
46 Water, Water intended for human consumption Ammonium ion concentration (calculated) PN-ISO 7150-1:2002
47 Water, Water intended for human consumption Aluminium concentration
Range (0,04 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605.02
48 Water, Water intended for human consumption Iron concentration
Range (20 – 25000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap.1:2016-06
49 Water, Water intended for human consumption Manganese concentration
Range (15 – 5000) μg/l
Spectrophotometric method PN-92/C-04590/02
50 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (2,0 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
51 Water, Water intended for human consumption Permanganate index
Range (0,5 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
52 Water, Water intended for human consumption Chloride concentration
Range (5,0 – 250) mg/l
Titrimetric method PN-ISO 9297:1994
53 Water, Water intended for human consumption Colour
Range (5,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
54 Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
55 Water, Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
56 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
57 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
58 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
59 Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method PN-EN ISO 14189:2016-10
60 Wastewater Iron concentration
Range (20 – 25000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap.1:2016-06
61 Water, Water intended for human consumption, Wastewater Total organic carbon concentration (TOC)
Range (1,0 – 500) mg/l
High-temperature combustion with IR detection PN-EN 1484:1999

Reference standards (49)

PB-01 wydanie 4 z dnia 17.02.2025
PB-03 wydanie 2 z 05.02.2025
PB-06 wydanie 2 z 05.02.2025
PN-77/C-04584
PN-82/C-04576.08
PN-82/C-04576/08
PN-92/C-04590/02
PN-92/C-04605.02
PN-EN 1233:2000 p.3
PN-EN 13342:2002
PN-EN 13346:2002
PN-EN 14671:2007
PN-EN 1484:1999
PN-EN 15934:2013-02 metoda A
PN-EN 15935:2013-02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 7150-1:2002
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap.1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002
PN-ISO 9280:2002
PN-ISO 9297:1994

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%201677