{"lab":{"_id":"69ad52a3de79e566650fb8d3","accr_number":"AB 1677","country":"PL","accr_body":"PCA","address":"SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ, ul. Wolności 44, 39-300 Mielec, CENTRALNE LABORATORIUM, ul. Kilińskiego 94","categories":["water","microbiology"],"city":"Mielec","imported_at":"2026-03-08T10:42:43.265Z","methods_count":61,"name":"MIEJSKIE PRZEDSIĘBIORSTWO GOSPODARKI KOMUNALNEJ","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1677.pdf"],"scope_summary":"","search_text":"miejskie przedsiębiorstwo gospodarki komunalnej spółka z ograniczoną odpowiedzialnością, ul. wolności 44, 39-300 mielec, centralne laboratorium, ul. kilińskiego 94 water pharma electronics materials other microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:48.553Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:02:43.268Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201677,podmiot.html","parse_date":"2026-08-13T08:02:43.268Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sewdiments"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, waste"},{"codes":"Q/28/P, Q/29/P","pl":"Badanie sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"10","date":"24.03.2026"},"map_coord":[50.28642,21.443239],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium Oczyszczalni Ścieków","address":"ul. Kilińskiego 94, 39-300 Mielec","city":"Mielec","postal":"39-300"},{"name":"Laboratorium Stacji Uzdatniania Wody","address":"ul. Wolności 29 B, 39-300 Mielec","city":"Mielec","postal":"39-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/2ed157dec9c38e9b9d2ae929955bc837/AB%201677.pdf","has_en":true,"category_counts":{"water":61,"microbiology":4,"materials":3},"category_scores":{"water":54.72,"microbiology":0.24,"materials":0.13},"has_zh":true,"lab_locations_zh":[{"name":"污水处理厂实验室","address":"ul. Kilińskiego 94, 39-300 Mielec","city":"Mielec","postal":"39-300"},{"name":"水处理站实验室","address":"ul. Wolności 29 B, 39-300 Mielec","city":"Mielec","postal":"39-300"}]},"methods":[{"_id":"6a7d7a230636ba417e41b1a5","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (5,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (5,0 – 50,0) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Wastewater Treatment Plant Laboratory Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 污水处理厂实验室 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1a6","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr","parameters":[{"name":"Zakres","range":"(100 – 10000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (100 – 10000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (100 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (100 – 10000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Chemical oxygen demand - COD- Cr","parameters_en":[{"name":"Range","range":"(100 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD- Cr Titrimetric method Wastewater Treatment Plant Laboratory Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(100 – 10000) mg/l O2"}],"search_zh":"污水 滴定法 污水处理厂实验室 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1a7","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Wastewater Treatment Plant Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 污水处理厂实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1a8","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,01 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 7150-1:2002","norm_bases":["PN-EN 7150-1:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,01 – 100) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-EN 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 污水处理厂实验室 范围 PN-EN 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1a9","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,004 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,004 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,004 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,004 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,004 – 20) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,004 – 20) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 污水处理厂实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1aa","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,1 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,1 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,1 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,1 – 20) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,1 – 20) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 20) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 污水处理厂实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1ab","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1 – 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1 – 200) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Wastewater Treatment Plant Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 200) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 污水处理厂实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1ac","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-01 wydanie 4 z dnia 17.02.2025","norm_bases":["PB-01 wydanie 4 z dnia 17.02.2025"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PB-01 wydanie 4 z dnia 17.02.2025 Woda, scieki Stezenie azotu ogolnego (z obliczen) PB-01 wydanie 4 z dnia 17.02.2025","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) Wastewater Treatment Plant Laboratory PB-01 wydanie 4 z dnia 17.02.2025","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） 污水处理厂实验室 PB-01 wydanie 4 z dnia 17.02.2025","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1ad","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,02 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,02 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,02 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,02 – 100) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 100) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 污水处理厂实验室 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1ae","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(2 – 2000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 2000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (2 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(2 – 2000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Wastewater Treatment Plant Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(2 – 2000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 污水处理厂实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1af","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Wastewater Treatment Plant Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 污水处理厂实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b0","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr","parameters":[{"name":"Zakres","range":"(10 – 50000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (10 – 50000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (10 – 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr\nZakres (10 – 50000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Chemical oxygen demand - COD- Cr","parameters_en":[{"name":"Range","range":"(10 – 50000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD- Cr Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(10 – 50000) mg/l O2"}],"search_zh":"水、废水 分光光度法 污水处理厂实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b1","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 – 15000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 – 15000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2 – 15000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2 – 15000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 – 15000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Wastewater Treatment Plant Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 15000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 污水处理厂实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b2","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Wastewater Treatment Plant Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 污水处理厂实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b3","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 10000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 10000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 10000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Wastewater Treatment Plant Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 10000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 污水处理厂实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b4","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie metali","parameters":[{"name":"cynk","range":"(0,05 – 50) mg/l"},{"name":"miedź","range":"(0,02 – 20) mg/l"},{"name":"nikiel","range":"(0,1 – 20) mg/l"},{"name":"kadm","range":"(0,02 – 10) mg/l"},{"name":"ołów","range":"(0,1 – 50) mg/l"},{"name":"żelazo","range":"(0,1 – 20) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\ncynk (0,05 – 50) mg/l\nmiedź (0,02 – 20) mg/l\nnikiel (0,1 – 20) mg/l\nkadm (0,02 – 10) mg/l\nołów (0,1 – 50) mg/l\nżelazo (0,1 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie metali\nZakres:\ncynk (0,05 – 50) mg/l\nmiedź (0,02 – 20) mg/l\nnikiel (0,1 – 20) mg/l\nkadm (0,02 – 10) mg/l\nołów (0,1 – 50) mg/l\nżelazo (0,1 – 20) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Woda, scieki Stezenie metali\nZakres:\ncynk (0,05 – 50) mg/l\nmiedz (0,02 – 20) mg/l\nnikiel (0,1 – 20) mg/l\nkadm (0,02 – 10) mg/l\nolow (0,1 – 50) mg/l\nzelazo (0,1 – 20) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["materials","water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Metal concentrations","parameters_en":[{"name":"zinc","range":"(0,05 – 50) mg/l"},{"name":"copper","range":"(0,02 – 20) mg/l"},{"name":"nickel","range":"(0,1 – 20) mg/l"},{"name":"cadmium","range":"(0,02 – 10) mg/l"},{"name":"lead","range":"(0,1 – 50) mg/l"},{"name":"iron","range":"(0,1 – 20) mg/l"}],"search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) Wastewater Treatment Plant Laboratory zinc copper nickel cadmium lead iron PN-ISO 8288:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,05 – 50) mg/l"},{"name":"铜","range":"(0,02 – 20) mg/l"},{"name":"镍","range":"(0,1 – 20) mg/l"},{"name":"镉","range":"(0,02 – 10) mg/l"},{"name":"铅","range":"(0,1 – 50) mg/l"},{"name":"铁","range":"(0,1 – 20) mg/l"}],"search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） 污水处理厂实验室 锌 铜 镍 镉 铅 铁 PN-ISO 8288:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b5","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa","reference":"PB-03 wydanie 2 z 05.02.2025","norm_bases":["PB-03 wydanie 2 z 05.02.2025"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa PB-03 wydanie 2 z 05.02.2025 Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa PB-03 wydanie 2 z 05.02.2025","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l"}],"search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Gravimetric method Wastewater Treatment Plant Laboratory Range PB-03 wydanie 2 z 05.02.2025","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l"}],"search_zh":"水、废水 石油醚可萃取物浓度 重量法 污水处理厂实验室 范围 PB-03 wydanie 2 z 05.02.2025","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"石油醚可萃取物浓度","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b6","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Wastewater Treatment Plant Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 污水处理厂实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b7","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing Wastewater Treatment Plant Laboratory PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 污水处理厂实验室 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1b8","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Wastewater Treatment Plant Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 污水处理厂实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a7d7a230636ba417e41b1b9","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha masa","parameters":[{"name":"Zakres","range":"(1,0 – 85,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa\nZakres (1,0 – 85,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha masa\nZakres (1,0 – 85,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady sciekowe Sucha masa\nZakres (1,0 – 85,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Dry matter","parameters_en":[{"name":"Range","range":"(1,0 – 85,0) %"}],"search_en":"Sewage sludge Dry matter Gravimetric method Wastewater Treatment Plant Laboratory Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","methodology_zh":"干物质","parameters_zh":[{"name":"范围","range":"(1,0 – 85,0) %"}],"search_zh":"污泥 干物质 重量法 污水处理厂实验室 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1ba","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość wody (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość wody (z obliczeń) PN-EN 15934:2013-02 metoda A Osady sciekowe Zawartosc wody (z obliczen) PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Water content (calculated)","search_en":"Sewage sludge Water content (calculated) Wastewater Treatment Plant Laboratory PN-EN 15934:2013-02 metoda A","test_object_en":"Sewage sludge","search_zh":"污泥 水分含量（计算值） 污水处理厂实验室 PN-EN 15934:2013-02 metoda A","test_object_zh":"污泥","methodology_zh":"水分含量（计算值）","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1bb","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Strata przy prażeniu suchej masy, pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(10,0 – 80,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu suchej masy, pozostałość po prażeniu\nZakres (10,0 – 80,0) %\nMetoda wagowa","reference":"PN-EN 15935:2013-02","norm_bases":["PN-EN 15935:2013-02"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Strata przy prażeniu suchej masy, pozostałość po prażeniu\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2013-02 Osady sciekowe Strata przy prazeniu suchej masy, pozostalosc po prazeniu\nZakres (10,0 – 80,0) %\nMetoda wagowa PN-EN 15935:2013-02","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Loss on ignition of dry matter, residue on ignition","parameters_en":[{"name":"Range","range":"(10,0 – 80,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter, residue on ignition Gravimetric method Wastewater Treatment Plant Laboratory Range PN-EN 15935:2013-02","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(10,0 – 80,0) %"}],"search_zh":"污泥 重量法 污水处理厂实验室 范围 PN-EN 15935:2013-02","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1bc","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"cynk","range":"(15 – 5000) mg/kg"},{"name":"miedź","range":"(5 – 2000) mg/kg"},{"name":"nikiel","range":"(15 – 1000) mg/kg"},{"name":"kadm","range":"(5 – 1000) mg/kg"},{"name":"ołów","range":"(15 – 1500) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\ncynk (15 – 5000) mg/kg\nmiedź (5 – 2000) mg/kg\nnikiel (15 – 1000) mg/kg\nkadm (5 – 1000) mg/kg\nołów (15 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 | PN-EN 13346:2002","norm_bases":["PN-ISO 8288:2002","PN-EN 13346:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\ncynk (15 – 5000) mg/kg\nmiedź (5 – 2000) mg/kg\nnikiel (15 – 1000) mg/kg\nkadm (5 – 1000) mg/kg\nołów (15 – 1500) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 13346:2002 Osady sciekowe Zawartosc metali\nZakres:\ncynk (15 – 5000) mg/kg\nmiedz (5 – 2000) mg/kg\nnikiel (15 – 1000) mg/kg\nkadm (5 – 1000) mg/kg\nolow (15 – 1500) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 | PN-EN 13346:2002","categories":["materials","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"zinc","range":"(15 – 5000) mg/kg"},{"name":"copper","range":"(5 – 2000) mg/kg"},{"name":"nickel","range":"(15 – 1000) mg/kg"},{"name":"cadmium","range":"(5 – 1000) mg/kg"},{"name":"lead","range":"(15 – 1500) mg/kg"}],"search_en":"Sewage sludge Metal content Flame atomic absorption spectrometry (FAAS) Wastewater Treatment Plant Laboratory zinc copper nickel cadmium lead PN-ISO 8288:2002 | PN-EN 13346:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"锌","range":"(15 – 5000) mg/kg"},{"name":"铜","range":"(5 – 2000) mg/kg"},{"name":"镍","range":"(15 – 1000) mg/kg"},{"name":"镉","range":"(5 – 1000) mg/kg"},{"name":"铅","range":"(15 – 1500) mg/kg"}],"search_zh":"污泥 金属含量 火焰原子吸收光谱法（FAAS） 污水处理厂实验室 锌 铜 镍 镉 铅 PN-ISO 8288:2002 | PN-EN 13346:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"金属含量","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1bd","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość chromu","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość chromu\nZakres (5,0 – 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 p.3 | PN-EN 13346:2002","norm_bases":["PN-EN 1233:2000 p.3","PN-EN 13346:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość chromu\nZakres (5,0 – 1000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p.3 | PN-EN 13346:2002 Osady sciekowe Zawartosc chromu\nZakres (5,0 – 1000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p.3 | PN-EN 13346:2002","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Chromium content","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/kg"}],"search_en":"Sewage sludge Chromium content Flame atomic absorption spectrometry (FAAS) Wastewater Treatment Plant Laboratory Range PN-EN 1233:2000 p.3 | PN-EN 13346:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/kg"}],"search_zh":"污泥 铬含量 火焰原子吸收光谱法（FAAS） 污水处理厂实验室 范围 PN-EN 1233:2000 p.3 | PN-EN 13346:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室","methodology_zh":"铬含量"},{"_id":"6a7d7a230636ba417e41b1be","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"wapń","range":"(1,0 – 50) %"},{"name":"magnez","range":"(0,10 – 5,0) %"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nwapń (1,0 – 50) %\nmagnez (0,10 – 5,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | PN-EN 13346:2002","norm_bases":["PN-EN ISO 7980:2002","PN-EN 13346:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nwapń (1,0 – 50) %\nmagnez (0,10 – 5,0) %\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002 Osady sciekowe Zawartosc metali\nZakres:\nwapn (1,0 – 50) %\nmagnez (0,10 – 5,0) %\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | PN-EN 13346:2002","categories":["water","materials"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Metal content","parameters_en":[{"name":"calcium","range":"(1,0 – 50) %"},{"name":"magnesium","range":"(0,10 – 5,0) %"}],"search_en":"Sewage sludge Metal content Flame atomic absorption spectrometry (FAAS) Wastewater Treatment Plant Laboratory calcium magnesium PN-EN ISO 7980:2002 | PN-EN 13346:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Sewage sludge","search_zh":"污泥 金属含量 火焰原子吸收光谱法（FAAS） 污水处理厂实验室 钙 镁 PN-EN ISO 7980:2002 | PN-EN 13346:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"污泥","methodology_zh":"金属含量","parameters_zh":[{"name":"钙","range":"(1,0 – 50) %"},{"name":"镁","range":"(0,10 – 5,0) %"}],"lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1bf","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,5 – 10,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość rtęci\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07 Osady sciekowe Zawartosc rteci\nZakres (0,5 – 10,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,5 – 10,0) mg/kg"}],"search_en":"Sewage sludge Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Wastewater Treatment Plant Laboratory Range PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Sewage sludge","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,5 – 10,0) mg/kg"}],"search_zh":"污泥 汞含量 冷蒸气原子吸收光谱法（CVAAS） 污水处理厂实验室 范围 PN-EN ISO 12846:2012 p. 7 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污泥","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1c0","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,10 – 5,0) %\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","PN-EN 13346:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,10 – 5,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,10 – 5,0) %\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) %"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Wastewater Treatment Plant Laboratory Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) %"}],"search_zh":"污泥 总磷含量 分光光度法 污水处理厂实验室 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | PN-EN 13346:2002","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1c1","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,50 – 10,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) %"}],"search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Wastewater Treatment Plant Laboratory Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 污水处理厂实验室 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1c2","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 – 5,0) %\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":"Laboratorium Oczyszczalni Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,10 – 5,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,10 – 5,0) %\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Wastewater Treatment Plant Laboratory","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) %"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Wastewater Treatment Plant Laboratory Range PN-EN 14671:2007 | PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) %"}],"search_zh":"污泥 氨氮含量 滴定法 污水处理厂实验室 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量","lab_section_zh":"污水处理厂实验室"},{"_id":"6a7d7a230636ba417e41b1c3","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody\nZakres (0 – 35) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody\nZakres (0 – 35) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej probki wody\nZakres (0 – 35) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0 – 35) °C"}],"search_en":"Water intended for human consumption Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample Water Treatment Plant Laboratory Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0 – 35) °C"}],"search_zh":"生活饮用水 水处理站实验室 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1c4","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Water Treatment Plant Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 水处理站实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1c5","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Water Treatment Plant Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 水处理站实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1c6","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,03 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 2 z 05.02.2025","norm_bases":["PB-06 wydanie 2 z 05.02.2025"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 2 z 05.02.2025 Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,03 – 1,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 2 z 05.02.2025","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,03 – 1,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine concentration Spectrophotometric method Water Treatment Plant Laboratory Range PB-06 wydanie 2 z 05.02.2025","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 1,0) mg/l"}],"search_zh":"生活饮用水 游离氯浓度 分光光度法 水处理站实验室 范围 PB-06 wydanie 2 z 05.02.2025","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1c7","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0 – 35) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody\nZakres (0 – 35) °C","reference":"PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6","PN-77/C-04584"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej próbki wody\nZakres (0 – 35) °C PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych, fizycznych (w tym sensorycznych) Temperatura pobranej probki wody\nZakres (0 – 35) °C PN-EN ISO 5667-6:2016-12 z wyl. pkt. 7.5, 7.6 | PN-77/C-04584","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0 – 35) °C"}],"search_en":"Water Sampling for chemical, physical (including sensory) testing Temperature of the collected water sample Water Treatment Plant Laboratory Range PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0 – 35) °C"}],"search_zh":"水 水处理站实验室 范围 PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.5, 7.6 | PN-77/C-04584","test_object_zh":"水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1c8","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1– 8"}],"technique":"Metoda pełna, parzysta, wybór niewymuszony","techniques":["Metoda pełna, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1– 8\nMetoda pełna, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba progowa zapachu TON\nZakres 1– 8\nMetoda pełna, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Liczba progowa zapachu TON\nZakres 1– 8\nMetoda pelna, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1– 8"}],"search_en":"Water Odour threshold number TON Full paired method, non-forced choice Water Treatment Plant Laboratory Range PN-EN 1622:2006","technique_en":"Full paired method, non-forced choice","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"1– 8"}],"search_zh":"水 嗅阈值 TON 完全法、成对法、非强制选择 水处理站实验室 范围 PN-EN 1622:2006","test_object_zh":"水","methodology_zh":"嗅阈值 TON","lab_section_zh":"水处理站实验室","technique_zh":"完全法、成对法、非强制选择"},{"_id":"6a7d7a230636ba417e41b1c9","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing Water Treatment Plant Laboratory PN-EN ISO 19458:2007","test_object_en":"Water, Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 水处理站实验室 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1ca","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Water Treatment Plant Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 水处理站实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1cb","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Water Treatment Plant Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水处理站实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1cc","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 1000) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Water Treatment Plant Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 1000) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水处理站实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1cd","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate nitrogen concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"水、生活饮用水 硝态氮浓度 分光光度法 水处理站实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1ce","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotanów (z obliczeń)","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów (z obliczeń) PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow (z obliczen) PN-82/C-04576.08","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Nitrate concentration (calculated)","search_en":"Water, Water intended for human consumption Nitrate concentration (calculated) Water Treatment Plant Laboratory PN-82/C-04576.08","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 硝酸盐浓度（由计算得出） 水处理站实验室 PN-82/C-04576.08","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室","methodology_zh":"硝酸盐浓度（由计算得出）"},{"_id":"6a7d7a230636ba417e41b1cf","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotu azotynowego\nZakres (0,01 – 1,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite nitrogen concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 亚硝态氮浓度 分光光度法 水处理站实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d0","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotynów (z obliczeń)","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów (z obliczeń) PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow (z obliczen) PN-EN 26777:1999","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Nitrite concentration (calculated)","search_en":"Water, Water intended for human consumption Nitrite concentration (calculated) Water Treatment Plant Laboratory PN-EN 26777:1999","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 亚硝酸盐浓度（由计算得出） 水处理站实验室 PN-EN 26777:1999","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室","methodology_zh":"亚硝酸盐浓度（由计算得出）"},{"_id":"6a7d7a230636ba417e41b1d1","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,02 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,02 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,02 – 5,0) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 氨氮浓度 分光光度法 水处理站实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d2","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie jonu amonowego (z obliczeń)","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego (z obliczeń) PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego (z obliczen) PN-ISO 7150-1:2002","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Ammonium ion concentration (calculated)","search_en":"Water, Water intended for human consumption Ammonium ion concentration (calculated) Water Treatment Plant Laboratory PN-ISO 7150-1:2002","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 铵离子浓度（由计算得出） 水处理站实验室 PN-ISO 7150-1:2002","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室","methodology_zh":"铵离子浓度（由计算得出）"},{"_id":"6a7d7a230636ba417e41b1d3","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,04 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605.02","norm_bases":["PN-92/C-04605.02"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605.02 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,04 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605.02","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,04 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Aluminium concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-92/C-04605.02","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,04 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 水处理站实验室 范围 PN-92/C-04605.02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d4","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 – 25000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap.1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap.1:2016-06"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 – 25000) μg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-ISO 6332:2001+Ap.1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 25000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 水处理站实验室 范围 PN-ISO 6332:2001+Ap.1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d5","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 5000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 5000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 5000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 5000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 5000) μg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-92/C-04590/02","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 5000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 水处理站实验室 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d6","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (2,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"P N - I S O 6059:1999","norm_bases":["P N - I S O 6059:1999"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (2,0 – 500) mg/l CaCO3\nMetoda miareczkowa P N - I S O 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (2,0 – 500) mg/l CaCO3\nMetoda miareczkowa P N - I S O 6059:1999","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Water Treatment Plant Laboratory Range P N - I S O 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 水处理站实验室 范围 P N - I S O 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d7","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,5 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 – 10) mg/l O2"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Water Treatment Plant Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 水处理站实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d8","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Water Treatment Plant Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 水处理站实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1d9","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5,0 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Water Treatment Plant Laboratory Range PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 水处理站实验室 范围 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1da","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water, Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) Water Treatment Plant Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） 水处理站实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1db","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Water, Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) Water Treatment Plant Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） 水处理站实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1dc","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["water","microbiology"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method Water Treatment Plant Laboratory PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 水处理站实验室 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1dd","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["microbiology","water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method Water Treatment Plant Laboratory PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水处理站实验室 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1de","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method Water Treatment Plant Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 水处理站实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1df","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba bakterii Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water","microbiology"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Clostridium perfringens bacteria count including spores","search_en":"Water, Water intended for human consumption Clostridium perfringens bacteria count including spores Membrane filtration method Water Treatment Plant Laboratory PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 水处理站实验室 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水处理站实验室","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a7d7a230636ba417e41b1e0","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 – 25000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap.1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap.1:2016-06"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06 Scieki Stezenie zelaza\nZakres (20 – 25000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap.1:2016-06","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 – 25000) μg/l"}],"search_en":"Wastewater Iron concentration Spectrophotometric method Water Treatment Plant Laboratory Range PN-ISO 6332:2001+Ap.1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 25000) μg/l"}],"search_zh":"污水 铁浓度 分光光度法 水处理站实验室 范围 PN-ISO 6332:2001+Ap.1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水处理站实验室"},{"_id":"6a7d7a230636ba417e41b1e1","lab_id":"69ad52a3de79e566650fb8d3","country":"PL","accr_number":"AB 1677","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie ogólnego węgla organicznego (OWO)","parameters":[{"name":"Zakres","range":"(1,0 – 500) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"Laboratorium Stacji Uzdatniania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (1,0 – 500) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water Treatment Plant Laboratory","methodology_en":"Total organic carbon concentration (TOC)","parameters_en":[{"name":"Range","range":"(1,0 – 500) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total organic carbon concentration (TOC) High-temperature combustion with IR detection Water Treatment Plant Laboratory Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 500) mg/l"}],"search_zh":"水、生活饮用水、废水 总有机碳浓度（TOC） 高温燃烧红外检测法 水处理站实验室 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"总有机碳浓度（TOC）","lab_section_zh":"水处理站实验室"}],"has_pdf":true}