🇵🇱 CFB LABORATORIUM TECHNOLOGII BETONU Sp. z o.o. PL
Construction
CFB LABORATORIUM TECHNOLOGII BETONU Sp. z o.o. is a laboratory accredited by PCA under number AB 1635 (Gdańsk, Poland). Its accreditation scope covers 12 test methods in the following areas: Construction. Test objects include: Fresh concrete, Concrete, Concrete in structures. Most frequently used techniques: Slump test method, Ordinary method, Pressure gauge method.
At a glance
- Accreditation number: PCA AB 1635
- Methods in scope: 12
- Types of test objects: 3
- Techniques used: 3
- City: Gdańsk, Poland
- Accreditation number
- AB 1635
- Accreditation body
- PCA
- Address
- ul. Olszyńska 3, 80-734 Gdańsk
- City
- Gdańsk, Poland
What this laboratory tests (3)
- Fresh concrete — 5 methods
- Concrete — 4 methods
- Concrete in structures — 3 methods
Analytical techniques used (3)
- Slump test method — 2 methods
- Ordinary method — 1 method
- Pressure gauge method — 1 method
Laboratory sections (2)
- CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk — 7 methods
- CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa — 5 methods
Accreditation scope — test methods (12)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk | |||||
| 1 | Fresh concrete | Consistency | Slump test method | PN-EN 12350-2:2019-07 | |
| 2 | Fresh concrete | Air content Range (0,1 – 10) % |
Pressure gauge method | PN-EN 12350-7:2019-08 | |
| 3 | Fresh concrete | Sampling | PN-EN 12350-1:2019-07 | ||
| 4 | Concrete | Compressive strength Force range (150 – 2900) kN |
PN-EN 12390-3:2019-07 | ||
| 5 | Concrete | Resistance to freezing | Ordinary method | PN-88/B-06250 | |
| 6 | Concrete in structures | Compressive strength Force range (150 – 2900) kN |
PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07 | ||
| 7 | Concrete in structures | Sampling | PN-EN 12504-1:2019-08 | ||
| CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa | |||||
| 8 | Fresh concrete | Consistency | Slump test method | PN-EN 12350-2:2019-07 | |
| 9 | Fresh concrete | Sampling | PN-EN 12350-1:2019-07 | ||
| 10 | Concrete | Compressive strength Force range (150 – 2900) kN |
PN-EN 12390-3:2019-07 | ||
| 11 | Concrete | Sampling | PN-EN 12350-1:2019-07 | ||
| 12 | Concrete in structures | Sampling | PN-EN 12504-1:2019-08 | ||
Reference standards (6)
PN-88/B-06250
PN-EN 12350-1:2019-07
PN-EN 12350-2:2019-07
PN-EN 12350-7:2019-08
PN-EN 12390-3:2019-07
PN-EN 12504-1:2019-08