{"lab":{"_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","address":"ul. Olszyńska 3, 80-734 Gdańsk","categories":["construction"],"city":"Gdańsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":12,"name":"CFB LABORATORIUM TECHNOLOGII BETONU Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1635.pdf"],"scope_summary":"","search_text":"cfb laboratorium technologii betonu sp. z o.o. ul. olszyńska 3, 80-734 gdańsk construction","status":"active","updated_at":"2026-03-08T14:50:46.177Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T11:01:04.141Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201635,podmiot.html","parse_date":"2026-08-17T11:01:04.141Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"J/5/P","pl":"Badania mechaniczne i pobieranie próbek wyrobów budowlanych","en":"Mechanical tests and sampling of building products"},{"codes":"N/5/P","pl":"Badania właściwości fizycznych i pobieranie próbek wyrobów budowlanych","en":"Tests of physical properties of building products"}],"issue":{"no":"11","date":"12.03.2026"},"map_coord":[54.335124,18.65075],"map_geo":"nominatim-street","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/91be6c8191c9a91d06ee16ab300d95ae/AB%201635.pdf","has_en":true,"category_counts":{"construction":12},"category_scores":{"construction":12},"has_zh":true},"methods":[{"_id":"6a82e9f0884ede9a1b2c45ff","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a82e9f0884ede9a1b2c4600","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Zawartość powietrza","parameters":[{"name":"Zakres","range":"(0,1 – 10) %"}],"technique":"Metoda ciśnieniomierza","techniques":["Metoda ciśnieniomierza"],"computed":[],"activity":"Zawartość powietrza\nZakres (0,1 – 10) %\nMetoda ciśnieniomierza","reference":"PN-EN 12350-7:2019-08","norm_bases":["PN-EN 12350-7:2019-08"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Zawartość powietrza\nZakres (0,1 – 10) %\nMetoda ciśnieniomierza PN-EN 12350-7:2019-08 Mieszanka betonowa Zawartosc powietrza\nZakres (0,1 – 10) %\nMetoda cisnieniomierza PN-EN 12350-7:2019-08","categories":["construction"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air content","parameters_en":[{"name":"Range","range":"(0,1 – 10) %"}],"search_en":"Fresh concrete Air content Pressure gauge method Range PN-EN 12350-7:2019-08","technique_en":"Pressure gauge method","test_object_en":"Fresh concrete","methodology_zh":"含气量","parameters_zh":[{"name":"范围","range":"(0,1 – 10) %"}],"search_zh":"混凝土拌合物 含气量 压力计法 范围 PN-EN 12350-7:2019-08","technique_zh":"压力计法","test_object_zh":"混凝土拌合物"},{"_id":"6a82e9f0884ede9a1b2c4601","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a82e9f0884ede9a1b2c4602","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (150 – 2900) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 – 2900) kN"}],"search_en":"Concrete Compressive strength Force range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 – 2900) kN"}],"search_zh":"混凝土 抗压强度 力值范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a82e9f0884ede9a1b2c4603","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton","methodology":"Odporność na działanie mrozu","parameters":[],"technique":"Metoda zwykła","techniques":["Metoda zwykła"],"computed":[],"activity":"Odporność na działanie mrozu\nMetoda zwykła","reference":"PN-88/B-06250","norm_bases":["PN-88/B-06250"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Odporność na działanie mrozu\nMetoda zwykła PN-88/B-06250 Beton Odpornosc na dzialanie mrozu\nMetoda zwykla PN-88/B-06250","categories":["construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Resistance to freezing","search_en":"Concrete Resistance to freezing Ordinary method PN-88/B-06250","technique_en":"Ordinary method","test_object_en":"Concrete","methodology_zh":"抗冻性","search_zh":"混凝土 抗冻性 常规法 PN-88/B-06250","test_object_zh":"混凝土","technique_zh":"常规法"},{"_id":"6a82e9f0884ede9a1b2c4604","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN","reference":"PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12504-1:2019-08","PN-EN 12390-3:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07 Beton w konstrukcjach Wytrzymalosc na sciskanie\nZakres sily (150 – 2900) kN PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","categories":["construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 – 2900) kN"}],"search_en":"Concrete in structures Compressive strength Force range PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","test_object_en":"Concrete in structures","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 – 2900) kN"}],"search_zh":"结构中的混凝土 抗压强度 力值范围 PN-EN 12504-1:2019-08 | PN-EN 12390-3:2019-07","test_object_zh":"结构中的混凝土"},{"_id":"6a82e9f0884ede9a1b2c4605","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Olszyńska 3, 80-734 Gdańsk","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Concrete in structures Sampling PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"},{"_id":"6a82e9f0884ede9a1b2c4606","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Konsystencja","parameters":[],"technique":"Metoda opadu stożka","techniques":["Metoda opadu stożka"],"computed":[],"activity":"Konsystencja\nMetoda opadu stożka","reference":"PN-EN 12350-2:2019-07","norm_bases":["PN-EN 12350-2:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Konsystencja\nMetoda opadu stożka PN-EN 12350-2:2019-07 Mieszanka betonowa Konsystencja\nMetoda opadu stozka PN-EN 12350-2:2019-07","categories":["construction"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Consistency","search_en":"Fresh concrete Consistency Slump test method PN-EN 12350-2:2019-07","technique_en":"Slump test method","test_object_en":"Fresh concrete","methodology_zh":"稠度","search_zh":"混凝土拌合物 稠度 坍落度法 PN-EN 12350-2:2019-07","technique_zh":"坍落度法","test_object_zh":"混凝土拌合物"},{"_id":"6a82e9f0884ede9a1b2c4607","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Mieszanka betonowa","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mieszanka betonowa Pobieranie próbek PN-EN 12350-1:2019-07 Mieszanka betonowa Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Fresh concrete Sampling PN-EN 12350-1:2019-07","test_object_en":"Fresh concrete","methodology_zh":"样品采集","search_zh":"混凝土拌合物 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土拌合物"},{"_id":"6a82e9f0884ede9a1b2c4608","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton","methodology":"Wytrzymałość na ściskanie","parameters":[{"name":"Zakres siły","range":"(150 – 2900) kN"}],"technique":null,"techniques":[],"computed":[],"activity":"Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN","reference":"PN-EN 12390-3:2019-07","norm_bases":["PN-EN 12390-3:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Wytrzymałość na ściskanie\nZakres siły (150 – 2900) kN PN-EN 12390-3:2019-07 Beton Wytrzymalosc na sciskanie\nZakres sily (150 – 2900) kN PN-EN 12390-3:2019-07","categories":["construction"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Compressive strength","parameters_en":[{"name":"Force range","range":"(150 – 2900) kN"}],"search_en":"Concrete Compressive strength Force range PN-EN 12390-3:2019-07","test_object_en":"Concrete","methodology_zh":"抗压强度","parameters_zh":[{"name":"力值范围","range":"(150 – 2900) kN"}],"search_zh":"混凝土 抗压强度 力值范围 PN-EN 12390-3:2019-07","test_object_zh":"混凝土"},{"_id":"6a82e9f0884ede9a1b2c4609","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12350-1:2019-07","norm_bases":["PN-EN 12350-1:2019-07"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton Pobieranie próbek PN-EN 12350-1:2019-07 Beton Pobieranie probek PN-EN 12350-1:2019-07","categories":["construction"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Concrete Sampling PN-EN 12350-1:2019-07","test_object_en":"Concrete","methodology_zh":"样品采集","search_zh":"混凝土 样品采集 PN-EN 12350-1:2019-07","test_object_zh":"混凝土"},{"_id":"6a82e9f0884ede9a1b2c460a","lab_id":"69ad52a3de79e566650fb899","country":"PL","accr_number":"AB 1635","accr_body":"PCA","test_object":"Beton w konstrukcjach","methodology":"Pobieranie próbek","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek","reference":"PN-EN 12504-1:2019-08","norm_bases":["PN-EN 12504-1:2019-08"],"lab_section":"CFB LABORATORIUM TECHNOLOGII BETONU, ul. Potockich 9A, 04-566 Warszawa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Beton w konstrukcjach Pobieranie próbek PN-EN 12504-1:2019-08 Beton w konstrukcjach Pobieranie probek PN-EN 12504-1:2019-08","categories":["construction"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling","search_en":"Concrete in structures Sampling PN-EN 12504-1:2019-08","test_object_en":"Concrete in structures","methodology_zh":"样品采集","search_zh":"结构中的混凝土 样品采集 PN-EN 12504-1:2019-08","test_object_zh":"结构中的混凝土"}],"has_pdf":true}