🇵🇱 MIEJSKIE WODOCIĄGI Sp. z o.o. PL

PCA AB 1610 • Chojnice, Poland • 23 methods

Water & wastewaterMicrobiology

MIEJSKIE WODOCIĄGI Sp. z o.o. is a laboratory accredited by PCA under number AB 1610 (Chojnice, Poland). Its accreditation scope covers 23 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Water intended for human consumption, wastewater. Most frequently used techniques: Spectrophotometric method, MPN method, Plate method (pour plate).

At a glance

  • Accreditation number: PCA AB 1610
  • Methods in scope: 23
  • Types of test objects: 3
  • Techniques used: 13
  • City: Chojnice, Poland
Accreditation number
AB 1610
Accreditation body
PCA
Address
Plac Piastowski 27a, 89-600 Chojnice, LABORATORIUM, ul. Igielska 15
City
Chojnice, Poland

What this laboratory tests (3)

Analytical techniques used (13)

Laboratory locations

Accreditation scope — test methods (23)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Wastewater Sampling for chemical and physical testing
Temperature of wastewater/ collected wastewater sample Range (5 – 40) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
3 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
4 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
5 Wastewater Chemical oxygen demand
COD-Cr Range (15 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
6 Wastewater Total nitrogen concentration
Range (1 – 500) mg/l
Spectrophotometric method PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338
7 Wastewater Total suspended solids (TSS)
Range (2 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
8 Wastewater Total phosphorus concentration
Range (0,2 – 25) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
9 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
10 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
11 Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
12 Water intended for human consumption Electrical conductivity
Range (84 – 1413) μS/cm
Conductometric method PN-EN 27888:1999
13 Water intended for human consumption Manganese concentration
Range (0,025 – 1,00) mg/l
Spectrophotometric method PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032
14 Water intended for human consumption Ammonium ion concentration
Range (0,11 – 2,50) mg/l
Spectrophotometric method PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304
15 Water intended for human consumption Turbidity
Range (0,50 – 50) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
16 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06
17 Water intended for human consumption Total hardness
Range (90 – 700) mg/l CaCO3
Colorimetric method PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285
18 Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
19 Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
20 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
21 Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
22 Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
23 Water intended for human consumption, wastewater Total iron concentration
Range (0,05 – 10) mg/l
Spectrophotometric method PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06

Reference standards (20)

PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338
PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032
PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304
PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285
PN-77/C-04584
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06