{"lab":{"_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","address":"Plac Piastowski 27a, 89-600 Chojnice, LABORATORIUM, ul. Igielska 15","categories":["water","microbiology"],"city":"Chojnice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":23,"name":"MIEJSKIE WODOCIĄGI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1610.pdf"],"scope_summary":"","search_text":"miejskie wodociągi sp. z o.o. plac piastowski 27a, 89-600 chojnice, laboratorium, ul. igielska 15 water other microbiology pharma electronics","status":"active","updated_at":"2026-03-08T14:50:44.749Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:02:00.274Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201610,podmiot.html","parse_date":"2026-08-13T08:02:00.274Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"}],"issue":{"no":"12","date":"16.04.2026"},"map_coord":[53.72004,17.57206],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/6bf7686d31f99a48e68612dff83d5766/AB%201610.pdf","has_en":true,"category_counts":{"water":23,"microbiology":3},"category_scores":{"water":20.35,"microbiology":0.35},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79f80636ba417e41b028","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura ścieków/ pobranej próbki ścieków"},{"name":"Zakres","range":"(5 – 40) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/ pobranej próbki ścieków\nZakres (5 – 40) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków/ pobranej próbki ścieków\nZakres (5 – 40) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow/ pobranej probki sciekow\nZakres (5 – 40) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of wastewater/ collected wastewater sample"},{"name":"Range","range":"(5 – 40) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory Temperature of wastewater/ collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(5 – 40) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b029","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b02a","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b02b","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 光学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b02c","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(15 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(15 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method Laboratory COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(15 – 10000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 实验室 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a7d79f80636ba417e41b02d","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1 – 500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1 – 500) mg/l\nMetoda spektrofotometryczna","reference":"PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338","norm_bases":["PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1 – 500) mg/l\nMetoda spektrofotometryczna PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338 Scieki Stezenie azotu ogolnego\nZakres (1 – 500) mg/l\nMetoda spektrofotometryczna PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1 – 500) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 500) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB-01:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK138, LCK238, LCK338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b02e","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 – 1000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b02f","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,2 – 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,2 – 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,2 – 25) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,2 – 25) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,2 – 25) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 25) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79f80636ba417e41b030","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b031","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b032","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b033","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84 – 1413) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 – 1413) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84 – 1413) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84 – 1413) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(84 – 1413) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 – 1413) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b034","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,025 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,025 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032","norm_bases":["PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,025 – 1,00) mg/l\nMetoda spektrofotometryczna PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,025 – 1,00) mg/l\nMetoda spektrofotometryczna PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,025 – 1,00) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Range PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 1,00) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 实验室 范围 PB-05:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCW032","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b035","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,11 – 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,11 – 2,50) mg/l\nMetoda spektrofotometryczna","reference":"PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304","norm_bases":["PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,11 – 2,50) mg/l\nMetoda spektrofotometryczna PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,11 – 2,50) mg/l\nMetoda spektrofotometryczna PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,11 – 2,50) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Laboratory Range PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,11 – 2,50) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 实验室 范围 PB-07:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie testu LCK304","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b036","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,50 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,50 – 50) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,50 – 50) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b037","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06 Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Visual method Laboratory Range PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 目视法 实验室 范围 PN-EN ISO 7887:2012 Metoda D +Ap1:2015-06","technique_zh":"目视法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b038","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(90 – 700) mg/l CaCO3"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Twardość ogólna\nZakres (90 – 700) mg/l CaCO3\nMetoda kolorymetryczna","reference":"PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285","norm_bases":["PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Twardość ogólna\nZakres (90 – 700) mg/l CaCO3\nMetoda kolorymetryczna PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285 Woda do spozycia przez ludzi Twardosc ogolna\nZakres (90 – 700) mg/l CaCO3\nMetoda kolorymetryczna PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(90 – 700) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total hardness Colorimetric method Laboratory Range PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(90 – 700) mg/l CaCO3"}],"search_zh":"生活饮用水 总硬度 比色法 实验室 范围 PB-12:2025, wyd. 01 z dn. 24.01.2025 r. na podstawie metody Hach nr 10285","technique_zh":"比色法","test_object_zh":"生活饮用水","methodology_zh":"总硬度"},{"_id":"6a7d79f80636ba417e41b039","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） 实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b03a","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number, Escherichia coli","search_en":"Water intended for human consumption Most probable number, Escherichia coli MPN method Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） 实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b03b","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b03c","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b03d","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"36°C 微生物总数","search_zh":"生活饮用水 36°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7d79f80636ba417e41b03e","lab_id":"69ad52a3de79e566650fb871","country":"PL","accr_number":"AB 1610","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, ścieki Stężenie żelaza ogólnego\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06 Woda do spozycia przez ludzi, scieki Stezenie zelaza ogolnego\nZakres (0,05 – 10) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,05 – 10) mg/l"}],"search_en":"Water intended for human consumption, wastewater Total iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10) mg/l"}],"search_zh":"总铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06","technique_zh":"分光光度法"}],"has_pdf":true}