🇵🇱 WODOCIĄGI I KANALIZACJA „AKWA” Sp. z o.o. PL
Water & wastewaterMicrobiology
WODOCIĄGI I KANALIZACJA „AKWA” Sp. z o.o. is a laboratory accredited by PCA under number AB 1572 (Nysa, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1572
- Methods in scope: 35
- Types of test objects: 5
- Techniques used: 12
- City: Nysa, Poland
- Accreditation number
- AB 1572
- Accreditation body
- PCA
- Address
- ul. Aleja Wojska Polskiego 2, 48-300 Nysa, LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH, Morów 68, 48-303 Nysa
- City
- Nysa, Poland
What this laboratory tests (5)
- Water, water intended for human consumption — 17 methods
- Water, wastewater — 11 methods
- Wastewater — 5 methods
- Water — 1 method
- Water intended for human consumption — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 8 methods
- Titrimetric method — 5 methods
- Membrane filtration method — 4 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Conductometric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Laboratory locations
- LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH — Morów 68, 48-303 Nysa
- Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa —
Accreditation scope — test methods (35)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6 | ||
| 3 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6 | ||
| 4 | Water, water intended for human consumption | Total iron concentration Range (10 – 20000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 5 | Water, water intended for human consumption | Manganese concentration Range (15 – 700) μg/l |
Spectrophotometric method | PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149 | |
| 6 | Water, water intended for human consumption | Turbidity Range (0,10 – 1000) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 7 | Water, water intended for human consumption | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06 | |
| 8 | Water, water intended for human consumption | Electrical conductivity Range (80 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 9 | Water, water intended for human consumption | Total hardness Range (30 – 700) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 10 | Water, water intended for human consumption | Calcium concentration Range (4 – 250) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 11 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 zał. A | ||
| 12 | Water, water intended for human consumption | Total viable count at 22oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 13 | Water, water intended for human consumption | Total viable count at 36oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 14 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 15 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 16 | Water, water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 17 | Water, water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 18 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 19 | Water, water intended for human consumption | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 20 | Water, wastewater | pH Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 21 | Water, wastewater | Ammonium nitrogen concentration Range (0,05 – 10,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 22 | Water, wastewater | Nitrite nitrogen concentration Range (0,010 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 23 | Water, wastewater | Nitrate nitrogen concentration Range (0,10 – 30) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 24 | Water, wastewater | Chloride concentration Range (5 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 25 | Water, wastewater | Total phosphorus concentration Range (0,10 – 50) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 | |
| 26 | Water, wastewater | Chemical oxygen demand - COD Range (10 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 27 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 28 | Water, wastewater | Total suspended solids (TSS) Range (4,0 – 4000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 29 | Water, wastewater | Kjeldahl nitrogen concentration Range (1,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 30 | Water, wastewater | Sulfate concentration Range (10 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 31 | Wastewater | Sampling for chemical and physical testing Temperature of wastewater / collected wastewater sample Range (2,0 – 35) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 32 | Wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 33 | Wastewater | Ammonium nitrogen concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 34 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 35 | Wastewater | Total iron concentration Range (0,010 – 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
Reference standards (33)
PB/DL-05 wydanie 3 z dn. 18.09.2020 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-4:1999 zał. A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu HACH nr 8149