🇵🇱 WODOCIĄGI I KANALIZACJA „AKWA” Sp. z o.o. PL

PCA AB 1572 • Nysa, Poland • 35 methods

Water & wastewaterMicrobiology

WODOCIĄGI I KANALIZACJA „AKWA” Sp. z o.o. is a laboratory accredited by PCA under number AB 1572 (Nysa, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Water, wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 1572
  • Methods in scope: 35
  • Types of test objects: 5
  • Techniques used: 12
  • City: Nysa, Poland
Accreditation number
AB 1572
Accreditation body
PCA
Address
ul. Aleja Wojska Polskiego 2, 48-300 Nysa, LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH, Morów 68, 48-303 Nysa
City
Nysa, Poland

What this laboratory tests (5)

Analytical techniques used (12)

Laboratory locations

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6
3 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6
4 Water, water intended for human consumption Total iron concentration
Range (10 – 20000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
5 Water, water intended for human consumption Manganese concentration
Range (15 – 700) μg/l
Spectrophotometric method PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149
6 Water, water intended for human consumption Turbidity
Range (0,10 – 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
7 Water, water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06
8 Water, water intended for human consumption Electrical conductivity
Range (80 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
9 Water, water intended for human consumption Total hardness
Range (30 – 700) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
10 Water, water intended for human consumption Calcium concentration
Range (4 – 250) mg/l
Titrimetric method PN-ISO 6058:1999
11 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A
12 Water, water intended for human consumption Total viable count at 22oC Plate method (pour plate) PN-EN ISO 6222:2004
13 Water, water intended for human consumption Total viable count at 36oC Plate method (pour plate) PN-EN ISO 6222:2004
14 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
15 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
16 Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
17 Water, water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
18 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
19 Water, water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
20 Water, wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
21 Water, wastewater Ammonium nitrogen concentration
Range (0,05 – 10,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
22 Water, wastewater Nitrite nitrogen concentration
Range (0,010 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
23 Water, wastewater Nitrate nitrogen concentration
Range (0,10 – 30) mg/l
Spectrophotometric method PN-82/C-04576/08
24 Water, wastewater Chloride concentration
Range (5 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
25 Water, wastewater Total phosphorus concentration
Range (0,10 – 50) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
26 Water, wastewater Chemical oxygen demand - COD
Range (10 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
27 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
28 Water, wastewater Total suspended solids (TSS)
Range (4,0 – 4000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
29 Water, wastewater Kjeldahl nitrogen concentration
Range (1,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
30 Water, wastewater Sulfate concentration
Range (10 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
31 Wastewater Sampling for chemical and physical testing
Temperature of wastewater / collected wastewater sample Range (2,0 – 35) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
32 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
33 Wastewater Ammonium nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
34 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
35 Wastewater Total iron concentration
Range (0,010 – 20) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06

Reference standards (33)

PB/DL-05 wydanie 3 z dn. 18.09.2020 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-4:1999 zał. A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6
PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu HACH nr 8149