{"lab":{"_id":"69ad52a3de79e566650fb834","accr_number":"AB 1572","country":"PL","accr_body":"PCA","address":"ul. Aleja Wojska Polskiego 2, 48-300 Nysa, LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH, Morów 68, 48-303 Nysa","categories":["water","microbiology"],"city":"Nysa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"WODOCIĄGI I KANALIZACJA „AKWA” Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1572.pdf"],"scope_summary":"","search_text":"wodociągi i kanalizacja „akwa” sp. z o.o. ul. aleja wojska polskiego 2, 48-300 nysa, laboratorium badania wody i ścieków w siestrzechowicach, morów 68, 48-303 nysa water microbiology pharma electronics automotive other","status":"active","updated_at":"2026-03-08T14:50:42.859Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:01:41.084Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201572,podmiot.html","parse_date":"2026-08-13T08:01:41.084Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"12","date":"27.03.2026"},"map_coord":[50.482161,17.342454],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH","address":"Morów 68, 48-303 Nysa","city":"Nysa","postal":"48-303"},{"name":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c89cba6619f6cdd069420c9c643c2440/AB%201572.pdf","has_en":true,"category_counts":{"water":35,"microbiology":5},"category_scores":{"water":30.63,"microbiology":0.63},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADANIA WODY I ŚCIEKÓW W SIESTRZECHOWICACH","address":"Morów 68, 48-303 Nysa","city":"Nysa","postal":"48-303"},{"name":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79e50636ba417e41af8e","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af8f","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyl. pkt. 7.2, 7.3, 7.5, 7.6","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 5667-6:2016-12 z wył. pkt. 7.2, 7.3, 7.5, 7.6","test_object_zh":"水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af90","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.3, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Sampling for microbiological testing","search_en":"Water, water intended for human consumption Sampling for microbiological testing Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6","test_object_en":"Water, water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.3, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af91","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(10 – 20000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (10 – 20000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (10 – 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (10 – 20000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(10 – 20000) μg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 20000) μg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af92","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 700) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna","reference":"PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149","norm_bases":["PB/DL-05 wydanie 3 z dn. 18.09.2020 r.","na podstawie testu HACH nr 8149"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 700) μg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 700) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PB/DL-05 wydanie 3 z dn. 18.09.2020 r. | na podstawie testu HACH nr 8149","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af93","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 1000) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 1000) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af94","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Visual method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN ISO 7887:2012 p. 7 +Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af95","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(80 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (80 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (80 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (80 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(80 – 2500) μS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(80 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af96","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Twardość ogólna","parameters":[{"name":"Zakres","range":"(30 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna\nZakres (30 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Twardość ogólna\nZakres (30 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Twardosc ogolna\nZakres (30 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total hardness","parameters_en":[{"name":"Range","range":"(30 – 700) mg/l CaCO3"}],"search_en":"Water, water intended for human consumption Total hardness Titrimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(30 – 700) mg/l CaCO3"}],"search_zh":"水、生活饮用水 总硬度 滴定法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","methodology_zh":"总硬度"},{"_id":"6a7d79e50636ba417e41af97","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(4 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (4 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (4 – 250) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (4 – 250) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(4 – 250) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(4 – 250) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af98","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 zał. A","norm_bases":["PN-C-04554-4:1999 zał. A"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 zal. A","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-C-04554-4:1999 zał. A","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-C-04554-4:1999 zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af99","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total viable count at 22oC","search_en":"Water, water intended for human consumption Total viable count at 22oC Plate method (pour plate) Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 22oC 微生物总数 平板法（倾注培养） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","methodology_zh":"22oC 微生物总数"},{"_id":"6a7d79e50636ba417e41af9a","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total viable count at 36oC","search_en":"Water, water intended for human consumption Total viable count at 36oC Plate method (pour plate) Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 36oC 微生物总数 平板法（倾注培养） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","methodology_zh":"36oC 微生物总数"},{"_id":"6a7d79e50636ba417e41af9b","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af9c","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af9d","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41af9e","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, water intended for human consumption Most probable number of Escherichia coli MPN method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a7d79e50636ba417e41af9f","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Intestinal enterococci count","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa0","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a7d79e50636ba417e41afa1","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Water, wastewater pH Potentiometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"水、废水 pH 值 电位法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa2","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa3","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,010 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,010 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa4","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 30) mg/l"}],"search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 30) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa5","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5 – 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa6","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,10 – 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa7","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(10 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (10 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(10 – 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(10 – 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量 ChZT（COD） 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa8","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afa9","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(4,0 – 4000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (4,0 – 4000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (4,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (4,0 – 4000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(4,0 – 4000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(4,0 – 4000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afaa","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afab","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afac","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura ścieków / pobranej próbki ścieków"},{"name":"Zakres","range":"(2,0 – 35) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (2,0 – 35) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków / pobranej próbki ścieków\nZakres (2,0 – 35) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow / pobranej probki sciekow\nZakres (2,0 – 35) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of wastewater / collected wastewater sample"},{"name":"Range","range":"(2,0 – 35) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Temperature of wastewater / collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"废水/所采废水样品的温度"},{"name":"范围","range":"(2,0 – 35) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 废水/所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afad","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afae","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afaf","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa PN-73/C-04576/14","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa PN-73/C-04576/14","test_object_zh":"污水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"},{"_id":"6a7d79e50636ba417e41afb0","lab_id":"69ad52a3de79e566650fb834","country":"PL","accr_number":"AB 1572","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Badania Wody i Ścieków w Siestrzechowicach; Morów 68, 48-303 Nysa","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,010 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,010 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 20) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Water and Wastewater Testing Laboratory in Siestrzechowice; Morów 68, 48-303 Nysa Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 20) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"Siestrzechowice 水与废水检测实验室；Morów 68, 48-303 Nysa"}],"has_pdf":true}