🇵🇱 WODOCIĄGI ZACHODNIOPOMORSKIE Sp. z o.o. PL

PCA AB 1559 • Goleniów, Poland • 34 methods

Water & wastewaterMicrobiology

WODOCIĄGI ZACHODNIOPOMORSKIE Sp. z o.o. is a laboratory accredited by PCA under number AB 1559 (Goleniów, Poland). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Water intended for human consumption, Wastewater, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Manual method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 1559
  • Methods in scope: 34
  • Types of test objects: 5
  • Techniques used: 11
  • City: Goleniów, Poland
Accreditation number
AB 1559
Accreditation body
PCA
Address
LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. I Brygady Legionów 8-10, 72-100 Goleniów
City
Goleniów, Poland

What this laboratory tests (5)

Analytical techniques used (11)

Laboratory sections (5)

Laboratory locations

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Testing Laboratory
1 Water, Water intended for human consumption, Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
2 Water, Water intended for human consumption, Wastewater Total iron concentration
Range (0,050 – 10,0) mg/l
Spectrophotometric method PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008
3 Water, Water intended for human consumption, Wastewater Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
4 Water, Water intended for human consumption, Wastewater Sulfate concentration
Range (40 – 900) mg/l
Turbidimetric method PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353
5 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
6 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
7 Water, Wastewater Chemical oxygen demand
COD-Cr Range (1,0 – 2000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
8 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007
9 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
10 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
11 Water, Water intended for human consumption Manganese concentration
Range (0,02 – 1,0) mg/l
Spectrophotometric method PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032
12 Water, Water intended for human consumption Ammonium ion concentration
Range (0,10 – 2,50) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
13 Water, Water intended for human consumption Nitrite concentration
Range (0,010 – 0,823) mg/l
Spectrophotometric method PN-EN 26777:1999
14 Water, Water intended for human consumption Nitrate concentration
Range (1,0 – 60,0) mg/l
Spectrophotometric method PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339
15 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06
16 Water, Water intended for human consumption Colour
Range (2 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06
17 Water, Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
18 Water, Water intended for human consumption Electrical conductivity
Range (100 – 2500) µS/cm
Conductometric method PN-EN 27888:1999
19 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (5,0 – 600) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
20 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
21 Wastewater Total nitrogen concentration
Range (5,0 – 200) mg/l
Spectrophotometric method PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338
22 Wastewater Total phosphorus concentration
Range (0,10 – 20,0) mg/l
Spectrophotometric method PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350
Oddział Terenowy Goleniów
23 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
24 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
25 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
Oddział Terenowy Stargard
26 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
27 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
28 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
Oddział Terenowy Chojna
29 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
30 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
31 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
Oddział Terenowy Płoty
32 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
33 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
34 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11

Reference standards (24)

PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008
PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350
PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338
PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353
PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339
PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007
PN-EN 872:2007/Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7887:2012 Metoda D
PN-EN ISO 7887:2012/Ap1:2015-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9297:1994