{"lab":{"_id":"69ad52a3de79e566650fb824","accr_number":"AB 1559","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADANIA WODY I ŚCIEKÓW, ul. I Brygady Legionów 8-10, 72-100 Goleniów","categories":["water","microbiology"],"city":"Goleniów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"WODOCIĄGI ZACHODNIOPOMORSKIE Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1559.pdf"],"scope_summary":"","search_text":"wodociągi zachodniopomorskie sp. z o.o. laboratorium badania wody i ścieków, ul. i brygady legionów 8-10, 72-100 goleniów water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:42.224Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:49:52.834Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201559,podmiot.html","parse_date":"2026-08-17T10:49:52.834Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi do badań mikrobiologicznych","en":"Sampling of drinking water for microbiological tests"}],"issue":{"no":"10","date":"17.06.2026"},"map_coord":[53.558162,14.844636],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADANIA WODY I ŚCIEKÓW","address":"ul. I Brygady Legionów 8-10","city":null,"postal":null},{"name":"Oddział Terenowy Goleniów","address":"ul. I Brygady Legionów 8-10, 72-100 Goleniów","city":"Goleniów","postal":"72-100"},{"name":"Oddział Terenowy Stargard","address":"ul. Stargardzka 9, Lipnik, 73-100 Stargard","city":"Stargard","postal":"73-100"},{"name":"Oddział Terenowy Chojna","address":"ul. Polna 7, 74-500 Chojna","city":"Chojna","postal":"74-500"},{"name":"Oddział Terenowy Płoty","address":"ul. Piaskowa 5, 72-310 Płoty","city":"Płoty","postal":"72-310"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/1aab79d75914c57cd7dd030089316fce/AB%201559.pdf","has_en":true,"category_counts":{"water":34,"microbiology":5},"category_scores":{"water":29.64,"microbiology":0.64},"has_zh":true},"methods":[{"_id":"6a82e750884ede9a1b2c413f","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 水与废水检测实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4140","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008","norm_bases":["PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza ogólnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza ogolnego\nZakres (0,050 – 10,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,050 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total iron concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 10,0) mg/l"}],"search_zh":"水、生活饮用水、废水 总铁浓度 分光光度法 水与废水检测实验室 范围 PB-04 wydanie 4 z dnia 14.10.2014 r. na podstawie metody Hach Lange 8008","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4141","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Water and Wastewater Testing Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、生活饮用水、废水 氯化物浓度 滴定法 水与废水检测实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4142","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(40 – 900) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (40 – 900) mg/l\nMetoda turbidymetryczna","reference":"PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353","norm_bases":["PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (40 – 900) mg/l\nMetoda turbidymetryczna PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353 Woda, Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (40 – 900) mg/l\nMetoda turbidymetryczna PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(40 – 900) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Sulfate concentration Turbidimetric method Water and Wastewater Testing Laboratory Range PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353","technique_en":"Turbidimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40 – 900) mg/l"}],"search_zh":"水、生活饮用水、废水 硫酸盐浓度 浊度法 水与废水检测实验室 范围 PB-08 wydanie 6 z dnia 31.08.2016 r. na podstawie testu Hach Lange LCK 153, LCK 353","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水检测实验室","technique_zh":"浊度法"},{"_id":"6a82e750884ede9a1b2c4143","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 1000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Testing Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 1000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 水与废水检测实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4144","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Testing Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 水与废水检测实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4145","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(1,0 – 2000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (1,0 – 2000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (1,0 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (1,0 – 2000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(1,0 – 2000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method Water and Wastewater Testing Laboratory COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(1,0 – 2000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 水与废水检测实验室 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"水与废水检测实验室","methodology_zh":"化学需氧量（COD）"},{"_id":"6a82e750884ede9a1b2c4146","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Testing Laboratory Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 水与废水检测实验室 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4147","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water and Wastewater Testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 水与废水检测实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4148","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Water and Wastewater Testing Laboratory PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 水与废水检测实验室 PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4149","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032","norm_bases":["PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 水与废水检测实验室 范围 PB-10 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCW 032","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414a","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 – 2,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,10 – 2,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,10 – 2,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,10 – 2,50) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 2,50) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 水与废水检测实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414b","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 – 0,823) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 – 0,823) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,010 – 0,823) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,010 – 0,823) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 – 0,823) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,823) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 水与废水检测实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414c","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,0 – 60,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339","norm_bases":["PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,0 – 60,0) mg/l\nMetoda spektrofotometryczna PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,0 – 60,0) mg/l\nMetoda spektrofotometryczna PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 水与废水检测实验室 范围 PB-09 wyd. 1 z dnia 06.08.2016 r. na podstawie testu Hach Lange LCK 339","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414d","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda D","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method Water and Wastewater Testing Laboratory Range PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 水与废水检测实验室 范围 PN-EN ISO 7887:2012 Metoda D | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414e","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (2 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 水与废水检测实验室 范围 PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c414f","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Water and Wastewater Testing Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水与废水检测实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4150","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2500) µS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Water and Wastewater Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) µS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水与废水检测实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4151","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 – 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 – 600) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Water and Wastewater Testing Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5,0 – 600) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 水与废水检测实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4152","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Water and Wastewater Testing Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 水与废水检测实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4153","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(5,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338","norm_bases":["PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338 Scieki Stezenie azotu ogolnego\nZakres (5,0 – 200) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 200) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 200) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 水与废水检测实验室 范围 PB-07 wydanie 6 z dnia 02.03.2018 r. na podstawie testu Hach Lange LCK 238, LCK 338","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4154","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350","norm_bases":["PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350"],"lab_section":"Laboratorium Badania Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350 Scieki Stezenie fosforu ogolnego\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Testing Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Testing Laboratory Range PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 水与废水检测实验室 范围 PB-06 wydanie 4 z dnia 14.10.2014 r. na podstawie testu Hach Lange LCK 348, LCK 349, LCK 350","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水检测实验室"},{"_id":"6a82e750884ede9a1b2c4155","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Terenowy Goleniów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c4156","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Oddział Terenowy Goleniów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c4157","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Oddział Terenowy Goleniów","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82e750884ede9a1b2c4158","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Terenowy Stargard","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c4159","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Oddział Terenowy Stargard","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c415a","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Oddział Terenowy Stargard","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82e750884ede9a1b2c415b","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Terenowy Chojna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c415c","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Oddział Terenowy Chojna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c415d","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Oddział Terenowy Chojna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a82e750884ede9a1b2c415e","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Terenowy Płoty","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c415f","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Oddział Terenowy Płoty","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. p.4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"生活饮用水"},{"_id":"6a82e750884ede9a1b2c4160","lab_id":"69ad52a3de79e566650fb824","country":"PL","accr_number":"AB 1559","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Oddział Terenowy Płoty","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"}],"has_pdf":true}