🇵🇱 ZESPÓŁ ELEKTROCIEPŁOWNI WROCŁAWSKICH PL

PCA AB 1551 • Poland • 28 methods

Water & wastewaterPetrochemistry & fuels

ZESPÓŁ ELEKTROCIEPŁOWNI WROCŁAWSKICH is a laboratory accredited by PCA under number AB 1551 (Poland). Its accreditation scope covers 28 test methods in the following areas: Water & wastewater, Petrochemistry & fuels. Test objects include: Solid fuels: - hard coal, Wastewater, Water, Waste o): code 10 01 01, 10 01 02.

At a glance

  • Accreditation number: PCA AB 1551
  • Methods in scope: 28
  • Types of test objects: 4
Accreditation number
AB 1551
Accreditation body
PCA
Address
KOGENERACJA S.A., WYDZIAŁ LABORATORIUM CHEMICZNE, ul. Łowiecka 24
City
Poland

What this laboratory tests (4)

Accreditation scope — test methods (28)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Element concentrations Range: zinc (0,01 – 50,0) mg/l lead (0,010 – 5,0) mg/l cobalt (0,0050 – 5,0) mg/l copper (0,010 – 5,0) mg/l boron (0,5 – 250) mg/l cadmium (0,0020 – 5,0) mg/l arsenic (0,010 – 5,0) mg/l chromium (0,005 – 5,0) mg/l nickel (0,010 – 5,0) mg/l iron (1,00 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
2 Wastewater Total suspended solids Range: (5,0 – 150) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
3 Wastewater Chloride concentration Range: (50,0 – 35000) mg/l Titrimetric method PN-ISO 9297:1994
4 Wastewater Sulphate concentration Range: (50,0 – 3000) mg/l Gravimetric method PN-ISO 9280:2002
5 Wastewater Sum of chloride and sulfate concentrations (calculated) PB/DTL/22/2023/A z dn. 22.09.2023 r.
6 Wastewater Chemical oxygen demand - SP–COD Range: (10,0 – 1000,0) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
7 Wastewater pH Range: (4,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012
8 Wastewater Anion concentrations Range chlorides (10,00 – 35000) mg/l sulfates (1,00 – 3000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
9 Wastewater Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic fluorescence spectrometry method (CVAFS) PN-EN ISO 17852:2009
10 Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (2,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
11 Wastewater Total organic carbon (TOC) concentration Range: (1,00 – 50,0) mg/l High-temperature combustion with IR detection PN-EN 1484:1999
12 Wastewater Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic absorption spectrometry method (CVAAS) PN-EN ISO 12846:2012+Ap1:2016- 07
13 Water Electrical conductivity Range: (200 – 3000) µS/cm Conductometric method PN-EN 27888:1999
14 Water Chloride concentration Range: (50,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
15 Water Anion concentrations Range chlorides (10,0 – 1000) mg/l sulfates (1,00 – 200) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
16 Waste o): code 10 01 01, 10 01 02 Total carbon content Range: (0,2 – 60,0) % High-temperature combustion method with IR detection PN-G-04571:1998
17 Solid fuels: - hard coal First-stage moisture content (transient) Range: (0,5 – 15,0) % Gravimetric method PN-ISO 589:2006
18 Solid fuels: - hard coal Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 10,0) % Gravimetric method PN-ISO 589:2006 Metoda A1
19 Solid fuels: - hard coal Total moisture content (calculated)
20 Solid fuels: - hard coal Moisture content in the analytical sample Range: (0,5 – 10,0) % Gravimetric method PN-ISO 11722:2009
21 Solid fuels: - hard coal Ash content Range: (2,0 – 50,0) % Gravimetric method PN-ISO 1171:2002
22 Solid fuels: - hard coal Total sulphur content Range: (0,10 – 2,00) % High-temperature combustion with IR detection method PN-G-04584:2001
23 Solid fuels: - hard coal Total carbon content Range: (45,0 – 80,0) % High-temperature combustion method with IR detection PN-G-04571:1998
24 Solid fuels: - hard coal Total hydrogen content Range: (3,00 – 5,00) % High-temperature combustion method with IR detection
25 Solid fuels: - hard coal Gross calorific value Range: (15 000 – 35 000) kJ/kg Calorimetric method Net calorific value (calculated) PN-ISO 1928:2020-05
26 Solid fuels: - hard coal Moisture content in the analytical sample Range: (0,5 – 7,0) % Thermogravimetric method (TGA) PN-G-04560:1998
27 Solid fuels: - hard coal Ash content Range: (5,0 – 45,0) % Thermogravimetric method (TGA)
28 Solid fuels: - hard coal Volatile matter content at 850 °C Range: (10,0 – 30,0) % Gravimetric method PN-G-04516:1998

Reference standards (22)

PB/DTL/22/2023/A z dn. 22.09.2023 r.
PN-EN 1484:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012+Ap1:2016- 07
PN-EN ISO 17852:2009
PN-G-04516:1998
PN-G-04560:1998
PN-G-04571:1998
PN-G-04584:2001
PN-ISO 1171:2002
PN-ISO 11722:2009
PN-ISO 15705:2005
PN-ISO 1928:2020-05
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 589:2006
PN-ISO 589:2006 Metoda A1
PN-ISO 9280:2002
PN-ISO 9297:1994