{"lab":{"_id":"69ad52a3de79e566650fb81a","accr_number":"AB 1551","country":"PL","accr_body":"PCA","address":"KOGENERACJA S.A., WYDZIAŁ LABORATORIUM CHEMICZNE, ul. Łowiecka 24","categories":["water","petro"],"city":"","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"ZESPÓŁ ELEKTROCIEPŁOWNI WROCŁAWSKICH","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1551.pdf"],"scope_summary":"","search_text":"zespół elektrociepłowni wrocławskich kogeneracja s.a., wydział laboratorium chemiczne, ul. łowiecka 24 water other materials pharma electronics environment petro","status":"active","updated_at":"2026-03-08T14:50:41.798Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:41.798Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201551,podmiot.html","parse_date":"2026-07-17T16:19:09.895Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/10; C/28; C/32","pl":"Badania chemiczne paliw stałych, wody, odpadów","en":"Chemical tests of solid fuels, water, waste"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/10; N/28","pl":"Badania właściwości fizycznych paliw stałych, wody","en":"Tests of physical properties of solid fuels, water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"16","date":"16.01.2026"},"has_en":true,"category_counts":{"water":15,"petro":12,"materials":1,"environment":1},"category_scores":{"water":7.76,"petro":4.97,"materials":0.03,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a5a55fd9af9f73f382533ea","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków Zakres: cynk (0,01 – 50,0) mg/l ołów (0,010 – 5,0) mg/l kobalt (0,0050 – 5,0) mg/l miedź (0,010 – 5,0) mg/l bor (0,5 – 250) mg/l kadm (0,0020 – 5,0) mg/l arsen (0,010 – 5,0) mg/l chrom (0,005 – 5,0) mg/l nikiel (0,010 – 5,0) mg/l żelazo (1,00 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: zinc (0,01 – 50,0) mg/l lead (0,010 – 5,0) mg/l cobalt (0,0050 – 5,0) mg/l copper (0,010 – 5,0) mg/l boron (0,5 – 250) mg/l cadmium (0,0020 – 5,0) mg/l arsenic (0,010 – 5,0) mg/l chromium (0,005 – 5,0) mg/l nickel (0,010 – 5,0) mg/l iron (1,00 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: cynk (0,01 – 50,0) mg/l ołów (0,010 – 5,0) mg/l kobalt (0,0050 – 5,0) mg/l miedź (0,010 – 5,0) mg/l bor (0,5 – 250) mg/l kadm (0,0020 – 5,0) mg/l arsen (0,010 – 5,0) mg/l chrom (0,005 – 5,0) mg/l nikiel (0,010 – 5,0) mg/l żelazo (1,00 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków Zakres: cynk (0,01 – 50,0) mg/l ołów (0,010 – 5,0) mg/l kobalt (0,0050 – 5,0) mg/l miedź (0,010 – 5,0) mg/l bor (0,5 – 250) mg/l kadm (0,0020 – 5,0) mg/l arsen (0,010 – 5,0) mg/l chrom (0,005 – 5,0) mg/l nikiel (0,010 – 5,0) mg/l żelazo (1,00 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow Zakres: cynk (0,01 – 50,0) mg/l olow (0,010 – 5,0) mg/l kobalt (0,0050 – 5,0) mg/l miedz (0,010 – 5,0) mg/l bor (0,5 – 250) mg/l kadm (0,0020 – 5,0) mg/l arsen (0,010 – 5,0) mg/l chrom (0,005 – 5,0) mg/l nikiel (0,010 – 5,0) mg/l zelazo (1,00 – 20,0) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Element concentrations Range: zinc (0,01 – 50,0) mg/l lead (0,010 – 5,0) mg/l cobalt (0,0050 – 5,0) mg/l copper (0,010 – 5,0) mg/l boron (0,5 – 250) mg/l cadmium (0,0020 – 5,0) mg/l arsenic (0,010 – 5,0) mg/l chromium (0,005 – 5,0) mg/l nickel (0,010 – 5,0) mg/l iron (1,00 – 20,0) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"污水 PN-EN ISO 11885:2009","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533eb","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (5,0 – 150) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (5,0 – 150) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (5,0 – 150) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (5,0 – 150) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (5,0 – 150) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids Range: (5,0 – 150) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533ec","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (50,0 – 35000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (50,0 – 35000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (50,0 – 35000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (50,0 – 35000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (50,0 – 35000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (50,0 – 35000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 PN-ISO 9297:1994","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533ed","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów Zakres: (50,0 – 3000) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (50,0 – 3000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (50,0 – 3000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów Zakres: (50,0 – 3000) mg/l Metoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow Zakres: (50,0 – 3000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulphate concentration Range: (50,0 – 3000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"污水 PN-ISO 9280:2002","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533ee","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Suma stężeń chlorków i siarczanów (z obliczeń)","methodology_en":"Sum of chloride and sulfate concentrations (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Suma stężeń chlorków i siarczanów (z obliczeń)","reference":"PB/DTL/22/2023/A z dn. 22.09.2023 r.","norm_bases":["PB/DTL/22/2023/A z dn. 22.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Suma stężeń chlorków i siarczanów (z obliczeń) PB/DTL/22/2023/A z dn. 22.09.2023 r. Scieki Suma stezen chlorkow i siarczanow (z obliczen) PB/DTL/22/2023/A z dn. 22.09.2023 r.","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sum of chloride and sulfate concentrations (calculated) PB/DTL/22/2023/A z dn. 22.09.2023 r.","search_zh":"污水 PB/DTL/22/2023/A z dn. 22.09.2023 r.","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533ef","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - SP–ChZT Zakres: (10,0 – 1000,0) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - SP–COD Range: (10,0 – 1000,0) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - SP–ChZT Zakres: (10,0 – 1000,0) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - SP–ChZT Zakres: (10,0 – 1000,0) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - SP–ChZT Zakres: (10,0 – 1000,0) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - SP–COD Range: (10,0 – 1000,0) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f0","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: (4,0 – 10,0) Metoda potencjometryczna","methodology_en":"pH Range: (4,0 – 10,0) Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: (4,0 – 10,0) Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: (4,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: (4,0 – 10,0) Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: (4,0 – 10,0) Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 pH 范围：(4,0 – 10,0) 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","methodology_zh":"pH 范围：(4,0 – 10,0) 电位法"},{"_id":"6a5a55fd9af9f73f382533f1","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie anionów Zakres chlorki (10,00 – 35000) mg/l siarczany (1,00 – 3000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range chlorides (10,00 – 35000) mg/l sulfates (1,00 – 3000) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres chlorki (10,00 – 35000) mg/l siarczany (1,00 – 3000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie anionów Zakres chlorki (10,00 – 35000) mg/l siarczany (1,00 – 3000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow Zakres chlorki (10,00 – 35000) mg/l siarczany (1,00 – 3000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Anion concentrations Range chlorides (10,00 – 35000) mg/l sulfates (1,00 – 3000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"污水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f2","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","methodology_en":"Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic fluorescence spectrometry method (CVAFS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS)","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009 Scieki Stezenie rteci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda fluorescencyjnej spektrometrii atomowej z generowaniem zimnych par (CVAFS) PN-EN ISO 17852:2009","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic fluorescence spectrometry method (CVAFS) PN-EN ISO 17852:2009","search_zh":"污水 PN-EN ISO 17852:2009","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f3","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (2,0 – 40,0) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (2,0 – 40,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (2,0 – 40,0) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (2,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura sciekow/pobranej probki sciekow Zakres: (2,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (2,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f4","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 50,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total organic carbon (TOC) concentration Range: (1,00 – 50,0) mg/l High-temperature combustion with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 50,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie ogólnego węgla organicznego (OWO) Zakres: (1,00 – 50,0) mg/l Metoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Scieki Stezenie ogolnego wegla organicznego (OWO) Zakres: (1,00 – 50,0) mg/l Metoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total organic carbon (TOC) concentration Range: (1,00 – 50,0) mg/l High-temperature combustion with IR detection PN-EN 1484:1999","search_zh":"污水 PN-EN 1484:1999","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f5","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic absorption spectrometry method (CVAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016- 07","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016- 07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016- 07 Scieki Stezenie rteci Zakres: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016- 07","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,00010 – 0,100) mg/l (0,10 – 100) µg/l Cold vapour atomic absorption spectrometry method (CVAAS) PN-EN ISO 12846:2012+Ap1:2016- 07","search_zh":"污水 PN-EN ISO 12846:2012+Ap1:2016- 07","test_object_zh":"污水"},{"_id":"6a5a55fd9af9f73f382533f6","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (200 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (200 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (200 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (200 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (200 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Electrical conductivity Range: (200 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 PN-EN 27888:1999","test_object_zh":"水"},{"_id":"6a5a55fd9af9f73f382533f7","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków Zakres: (50,0 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (50,0 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (50,0 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków Zakres: (50,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow Zakres: (50,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chloride concentration Range: (50,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 PN-ISO 9297:1994","test_object_zh":"水"},{"_id":"6a5a55fd9af9f73f382533f8","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów Zakres chlorki (10,0 – 1000) mg/l siarczany (1,00 – 200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Anion concentrations Range chlorides (10,0 – 1000) mg/l sulfates (1,00 – 200) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie anionów Zakres chlorki (10,0 – 1000) mg/l siarczany (1,00 – 200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów Zakres chlorki (10,0 – 1000) mg/l siarczany (1,00 – 200) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Stezenie anionow Zakres chlorki (10,0 – 1000) mg/l siarczany (1,00 – 200) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Anion concentrations Range chlorides (10,0 – 1000) mg/l sulfates (1,00 – 200) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水"},{"_id":"6a5a55fd9af9f73f382533f9","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Odpady o): kod 10 01 01, 10 01 02","test_object_en":"Waste o): code 10 01 01, 10 01 02","methodology":"Zawartość węgla całkowitego Zakres: (0,2 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (0,2 – 60,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (0,2 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o): kod 10 01 01, 10 01 02 Zawartość węgla całkowitego Zakres: (0,2 – 60,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady o): kod 10 01 01, 10 01 02 Zawartosc wegla calkowitego Zakres: (0,2 – 60,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste o): code 10 01 01, 10 01 02 Total carbon content Range: (0,2 – 60,0) % High-temperature combustion method with IR detection PN-G-04571:1998"},{"_id":"6a5a55fd9af9f73f382533fa","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (0,5 – 15,0) % Metoda wagowa","methodology_en":"First-stage moisture content (transient) Range: (0,5 – 15,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (0,5 – 15,0) % Metoda wagowa","reference":"PN-ISO 589:2006","norm_bases":["PN-ISO 589:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wilgoci pierwszego stopnia (przemijającej) Zakres: (0,5 – 15,0) % Metoda wagowa PN-ISO 589:2006 Paliwa stale: - wegiel kamienny Zawartosc wilgoci pierwszego stopnia (przemijajacej) Zakres: (0,5 – 15,0) % Metoda wagowa PN-ISO 589:2006","categories":["petro"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal First-stage moisture content (transient) Range: (0,5 – 15,0) % Gravimetric method PN-ISO 589:2006","search_zh":"固体燃料： — 烟煤 PN-ISO 589:2006","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f382533fb","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa","methodology_en":"Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa","reference":"PN-ISO 589:2006 Metoda A1","norm_bases":["PN-ISO 589:2006 Metoda A1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wilgoci drugiego stopnia (wilgoci pozostałej w próbce) Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 589:2006 Metoda A1 Paliwa stale: - wegiel kamienny Zawartosc wilgoci drugiego stopnia (wilgoci pozostalej w probce) Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 589:2006 Metoda A1","categories":["petro"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Second-stage moisture content (moisture remaining in the sample) Range: (0,5 – 10,0) % Gravimetric method PN-ISO 589:2006 Metoda A1","search_zh":"固体燃料： — 烟煤 PN-ISO 589:2006 Metoda A1","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f382533fc","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","methodology_en":"Total moisture content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wilgoci całkowitej (z obliczeń) Paliwa stale: - wegiel kamienny Zawartosc wilgoci calkowitej (z obliczen)","categories":["petro"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Total moisture content (calculated)","methodology_zh":"全水分含量（计算值）","search_zh":"固体燃料： — 烟煤 全水分含量（计算值）","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f382533fd","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 10,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (0,5 – 10,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 10,0) % Metoda wagowa","reference":"PN-ISO 11722:2009","norm_bases":["PN-ISO 11722:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 11722:2009 Paliwa stale: - wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,5 – 10,0) % Metoda wagowa PN-ISO 11722:2009","categories":["petro"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Moisture content in the analytical sample Range: (0,5 – 10,0) % Gravimetric method PN-ISO 11722:2009","search_zh":"固体燃料： — 烟煤 PN-ISO 11722:2009","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f382533fe","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość popiołu Zakres: (2,0 – 50,0) % Metoda wagowa","methodology_en":"Ash content Range: (2,0 – 50,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (2,0 – 50,0) % Metoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość popiołu Zakres: (2,0 – 50,0) % Metoda wagowa PN-ISO 1171:2002 Paliwa stale: - wegiel kamienny Zawartosc popiolu Zakres: (2,0 – 50,0) % Metoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Ash content Range: (2,0 – 50,0) % Gravimetric method PN-ISO 1171:2002","search_zh":"固体燃料： — 烟煤 PN-ISO 1171:2002","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f382533ff","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość siarki całkowitej Zakres: (0,10 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total sulphur content Range: (0,10 – 2,00) % High-temperature combustion with IR detection method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej Zakres: (0,10 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość siarki całkowitej Zakres: (0,10 – 2,00) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale: - wegiel kamienny Zawartosc siarki calkowitej Zakres: (0,10 – 2,00) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Total sulphur content Range: (0,10 – 2,00) % High-temperature combustion with IR detection method PN-G-04584:2001","search_zh":"固体燃料： — 烟煤 全硫含量 范围：(0,10 – 2,00) % 高温燃烧-红外检测法 PN-G-04584:2001","test_object_zh":"固体燃料： — 烟煤","methodology_zh":"全硫含量 范围：(0,10 – 2,00) % 高温燃烧-红外检测法"},{"_id":"6a5a55fd9af9f73f38253400","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość węgla całkowitego Zakres: (45,0 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total carbon content Range: (45,0 – 80,0) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego Zakres: (45,0 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość węgla całkowitego Zakres: (45,0 – 80,0) % Metoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale: - wegiel kamienny Zawartosc wegla calkowitego Zakres: (45,0 – 80,0) % Metoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Total carbon content Range: (45,0 – 80,0) % High-temperature combustion method with IR detection PN-G-04571:1998","search_zh":"固体燃料： — 烟煤 PN-G-04571:1998","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f38253401","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wodoru całkowitego Zakres: (3,00 – 5,00) % Metoda wysokotemperaturowego spalania z detekcją IR","methodology_en":"Total hydrogen content Range: (3,00 – 5,00) % High-temperature combustion method with IR detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wodoru całkowitego Zakres: (3,00 – 5,00) % Metoda wysokotemperaturowego spalania z detekcją IR","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wodoru całkowitego Zakres: (3,00 – 5,00) % Metoda wysokotemperaturowego spalania z detekcją IR Paliwa stale: - wegiel kamienny Zawartosc wodoru calkowitego Zakres: (3,00 – 5,00) % Metoda wysokotemperaturowego spalania z detekcja IR","categories":["petro"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Total hydrogen content Range: (3,00 – 5,00) % High-temperature combustion method with IR detection","search_zh":"固体燃料： — 烟煤","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f38253402","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Ciepło spalania Zakres: (15 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (15 000 – 35 000) kJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (15 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Ciepło spalania Zakres: (15 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-ISO 1928:2020-05 Paliwa stale: - wegiel kamienny Cieplo spalania Zakres: (15 000 – 35 000) kJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-ISO 1928:2020-05","categories":["petro"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Gross calorific value Range: (15 000 – 35 000) kJ/kg Calorimetric method Net calorific value (calculated) PN-ISO 1928:2020-05","search_zh":"固体燃料： — 烟煤 PN-ISO 1928:2020-05","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f38253403","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 7,0) % Metoda termograwimetryczna (TGA)","methodology_en":"Moisture content in the analytical sample Range: (0,5 – 7,0) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 7,0) % Metoda termograwimetryczna (TGA)","reference":"PN-G-04560:1998","norm_bases":["PN-G-04560:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość wilgoci w próbce analitycznej Zakres: (0,5 – 7,0) % Metoda termograwimetryczna (TGA) PN-G-04560:1998 Paliwa stale: - wegiel kamienny Zawartosc wilgoci w probce analitycznej Zakres: (0,5 – 7,0) % Metoda termograwimetryczna (TGA) PN-G-04560:1998","categories":["petro"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Moisture content in the analytical sample Range: (0,5 – 7,0) % Thermogravimetric method (TGA) PN-G-04560:1998","search_zh":"固体燃料： — 烟煤 PN-G-04560:1998","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f38253404","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość popiołu Zakres: (5,0 – 45,0) % Metoda termograwimetryczna (TGA)","methodology_en":"Ash content Range: (5,0 – 45,0) % Thermogravimetric method (TGA)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość popiołu Zakres: (5,0 – 45,0) % Metoda termograwimetryczna (TGA)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość popiołu Zakres: (5,0 – 45,0) % Metoda termograwimetryczna (TGA) Paliwa stale: - wegiel kamienny Zawartosc popiolu Zakres: (5,0 – 45,0) % Metoda termograwimetryczna (TGA)","categories":["petro"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Ash content Range: (5,0 – 45,0) % Thermogravimetric method (TGA)","search_zh":"固体燃料： — 烟煤","test_object_zh":"固体燃料： — 烟煤"},{"_id":"6a5a55fd9af9f73f38253405","lab_id":"69ad52a3de79e566650fb81a","country":"PL","accr_number":"AB 1551","accr_body":"PCA","test_object":"Paliwa stałe: - węgiel kamienny","test_object_en":"Solid fuels: - hard coal","methodology":"Zawartość części lotnych w temp. 850 °C Zakres: (10,0 – 30,0) % Metoda wagowa","methodology_en":"Volatile matter content at 850 °C Range: (10,0 – 30,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość części lotnych w temp. 850 °C Zakres: (10,0 – 30,0) % Metoda wagowa","reference":"PN-G-04516:1998","norm_bases":["PN-G-04516:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: - węgiel kamienny Zawartość części lotnych w temp. 850 °C Zakres: (10,0 – 30,0) % Metoda wagowa PN-G-04516:1998 Paliwa stale: - wegiel kamienny Zawartosc czesci lotnych w temp. 850 °C Zakres: (10,0 – 30,0) % Metoda wagowa PN-G-04516:1998","categories":["petro"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: - hard coal Volatile matter content at 850 °C Range: (10,0 – 30,0) % Gravimetric method PN-G-04516:1998","search_zh":"固体燃料： — 烟煤 PN-G-04516:1998","test_object_zh":"固体燃料： — 烟煤"}],"has_pdf":true}