🇵🇱 Podkarpackie Laboratorium Badawcze Sp. z o.o. PL
EnvironmentConstruction
Podkarpackie Laboratorium Badawcze Sp. z o.o. is a laboratory accredited by PCA under number AB 1475 (Rzeszów, Poland). Its accreditation scope covers 33 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment - emergency lighting, Workplace environment - outdoor electric lighting, General environment - noise from installations, equipment and indus….
At a glance
- Accreditation number: PCA AB 1475
- Methods in scope: 33
- Types of test objects: 12
- City: Rzeszów, Poland
- Accreditation number
- AB 1475
- Accreditation body
- PCA
- Address
- ul. Hanasiewicza 6A, 35-103 Rzeszów
- City
- Rzeszów, Poland
What this laboratory tests (12)
- Workplace environment - air — 7 methods
- Workplace environment - emergency lighting — 5 methods
- Workplace environment - outdoor electric lighting — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment - whole-body vibration — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – energy expenditure — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – moderate microclimate — 2 methods
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - air | Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - organic substances, including – inhalable fraction - inorganic substances – inhalable fraction – respirable fraction – thoracic fraction - metals and their compounds, including – inhalable fraction – respirable fraction - asbestos - respirable fibres - man-made mineral fibres excluding refractory ceramic fibres - respirable fibres Personal dosimetry method | PN-Z-04008-7:2002 + Az1:2004 | ||
| 2 | Workplace environment - air | Exposure index (calculated) | |||
| 3 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction - apatites and phosphorites - Portland cement - titanium dioxide - natural graphite - synthetic graphite - kaolin - amorphous and synthetic silica - wood dust - flour dust - dusts not classified according to toxicity - organic dusts of animal and plant origin except wood and flour dust - carbon black - man-made mineral fibres except refractory ceramic fibres - talc - coal (hard, brown) - magnesium calcium carbonate (dolomite) - silicon carbide, non-fibrous Range: (0,1 – 36,8) mg/m3 Gravimetric method | PN-Z-04507:2022-05+Ap1:2022-08 | ||
| 4 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction - apatites and phosphorites - Portland cement - natural graphite - amorphous and synthetic silica - organic dusts of animal and plant origin except wood and flour dust - talc - coal (hard, brown) Range: (0,1 – 14,62) mg/m3 Gravimetric method | PN-Z-04508:2022-05+Ap1:2022-08 | ||
| 5 | Workplace environment - air | Carbon monoxide concentration Range (2,32 – 232) mg/m3 (2 – 200) ppm Electrochemical method | IB-5.5.7 wydanie 8 z dnia 30.09.2022 r. | ||
| 6 | Workplace environment - air | Nitrogen monoxide concentration Range (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Electrochemical method | |||
| 7 | Workplace environment - air | Nitrogen dioxide concentration Range (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Electrochemical method | |||
| 8 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (50 – 135) dB C-weighted peak sound level Range: (50 – 138) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11 | ||
| 9 | Workplace environment - noise | Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated) | |||
| 10 | Workplace environment - indoor electric lighting | Illuminance Range: (5 – 5 000) lx Direct measurement method | PN-83/E-04040.03 | ||
| 11 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | |||
| 12 | Workplace environment - outdoor electric lighting | Illuminance Range: (5 - 5 000) Ix Direct measurement method | PN-83/E-04040.03 | ||
| 13 | Workplace environment - outdoor electric lighting | Illuminance uniformity (calculated) | |||
| 14 | Workplace environment - outdoor electric lighting | Illuminance uniformity (calculated) | |||
| 15 | Workplace environment - emergency lighting | Illuminance Range: (0,5 – 500) lx Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3 | ||
| 16 | Workplace environment - emergency lighting | Ratio of minimum to maximum illuminance (calculated) | |||
| 17 | Workplace environment - emergency lighting | Illuminance uniformity for the high-risk zone (calculated) | |||
| 18 | Workplace environment - emergency lighting | Lighting switch-on time Range: (1 – 80) s. | |||
| 19 | Workplace environment - emergency lighting | Minimum lighting operating time Range: (1 – 7200) s. | |||
| 20 | Workplace environment - whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,04 – 100) m/s² Direct measurement method | PN-EN 14253+A1:2011 | ||
| 21 | Workplace environment - whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated) | |||
| 22 | Workplace environment – hand-arm vibration | Frequency-weighted effective vibration acceleration Range: (0,1–100) m/s2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 23 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) (calculated) hwx hwy hwz | |||
| 24 | Workplace environment – cold microclimate | Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 15) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method | PN-EN ISO 11079:2008 | ||
| 25 | Workplace environment – cold microclimate | t wc index IREQ min index IREQ neutral index (calculated) | |||
| 26 | Workplace environment – moderate microclimate | Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 30) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method | PN-EN ISO 7730:2006 | ||
| 27 | Workplace environment – moderate microclimate | PMV index PPD index (calculated) | |||
| 28 | Workplace environment – hot microclimate | Air temperature Range: (10 – 60) °C Blackened globe temperature Range: (10 – 60) °C Natural wet bulb temperature Range: (10 – 50) °C Direct measurement method | PN-EN ISO 7243:2018-01 | ||
| 29 | Workplace environment – hot microclimate | WBGT index WBGT eff index (calculated) | |||
| 30 | Workplace environment – energy expenditure | Air temperature Range: (10 – 60) °C Air flow Range: (10 – 60) dm3/min. Direct measurement method | IB-5.5.9 wydanie 4 z dn. 01.07.2024 r. | ||
| 31 | Workplace environment – energy expenditure | Energy expenditure (calculated) | |||
| 32 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range: (24 - 135) dB Direct measurement method | Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F | ||
| 33 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated) | |||
Reference standards (16)
IB-5.5.7 wydanie 8 z dnia 30.09.2022 r.
IB-5.5.9 wydanie 4 z dn. 01.07.2024 r.
Nr 7
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11
PN-Z-04008-7:2002 + Az1:2004
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023
eniem pkt. F