{"lab":{"_id":"69ad52a3de79e566650fb7a2","accr_number":"AB 1475","country":"PL","accr_body":"PCA","address":"ul. Hanasiewicza 6A, 35-103 Rzeszów","categories":["environment","construction"],"city":"Rzeszów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"Podkarpackie Laboratorium Badawcze Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1475.pdf"],"scope_summary":"","search_text":"podkarpackie laboratorium badawcze sp. z o.o. ul. hanasiewicza 6a, 35-103 rzeszów environment materials other pharma electronics metrology","status":"active","updated_at":"2026-03-08T14:50:37.709Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:37.709Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201475,podmiot.html","parse_date":"2026-07-17T16:19:08.168Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) - working environment (harmful and nuisance factors noise, lighting, vibration, microclimate, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"C/33","pl":"Badania chemiczne powietrza – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests of air – working environment (harmful factors - air)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling) – working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek powietrza","en":"Sampling of air"}],"issue":{"no":"23","date":"25.11.2025"},"map_coord":[50.029557,21.976996],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":33,"construction":2,"materials":1},"category_scores":{"environment":30.25,"construction":0.11,"materials":0.03},"has_zh":true},"methods":[{"_id":"6a5a55fc9af9f73f38252ea4","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje organiczne, w tym – frakcja wdychalna - substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna – frakcja torakalna - metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna - azbest - włókna respirabilne - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - organic substances, including – inhalable fraction - inorganic substances – inhalable fraction – respirable fraction – thoracic fraction - metals and their compounds, including – inhalable fraction – respirable fraction - asbestos - respirable fibres - man-made mineral fibres excluding refractory ceramic fibres - respirable fibres Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje organiczne, w tym – frakcja wdychalna - substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna – frakcja torakalna - metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna - azbest - włókna respirabilne - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 + Az1:2004","norm_bases":["PN-Z-04008-7:2002 + Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje organiczne, w tym – frakcja wdychalna - substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna – frakcja torakalna - metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna - azbest - włókna respirabilne - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - włókna respirabilne Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na: - czynniki pylowe – frakcja wdychalna – frakcja respirabilna - substancje organiczne, w tym – frakcja wdychalna - substancje nieorganiczne – frakcja wdychalna – frakcja respirabilna – frakcja torakalna - metale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna - azbest - wlokna respirabilne - sztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych - wlokna respirabilne Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 + Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - organic substances, including – inhalable fraction - inorganic substances – inhalable fraction – respirable fraction – thoracic fraction - metals and their compounds, including – inhalable fraction – respirable fraction - asbestos - respirable fibres - man-made mineral fibres excluding refractory ceramic fibres - respirable fibres Personal dosimetry method PN-Z-04008-7:2002 + Az1:2004","search_zh":"工作场所环境 — 空气 PN-Z-04008-7:2002 + Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252ea5","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252ea6","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - apatyty i fosforyty - cement portlandzki - ditlenek tytanu - grafit naturalny - grafit syntetyczny - kaolin - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły mąki - pyły niesklasyfikowane ze względu na toksyczność - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - sadza techniczna - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - talk - węgiel (kamienny, brunatny) - węglan magnezu wapnia (dolomit) - węglik krzemu, niewłóknisty Zakres: (0,1 – 36,8) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – inhalable fraction - apatites and phosphorites - Portland cement - titanium dioxide - natural graphite - synthetic graphite - kaolin - amorphous and synthetic silica - wood dust - flour dust - dusts not classified according to toxicity - organic dusts of animal and plant origin except wood and flour dust - carbon black - man-made mineral fibres except refractory ceramic fibres - talc - coal (hard, brown) - magnesium calcium carbonate (dolomite) - silicon carbide, non-fibrous Range: (0,1 – 36,8) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - apatyty i fosforyty - cement portlandzki - ditlenek tytanu - grafit naturalny - grafit syntetyczny - kaolin - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły mąki - pyły niesklasyfikowane ze względu na toksyczność - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - sadza techniczna - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - talk - węgiel (kamienny, brunatny) - węglan magnezu wapnia (dolomit) - węglik krzemu, niewłóknisty Zakres: (0,1 – 36,8) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04507:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna - apatyty i fosforyty - cement portlandzki - ditlenek tytanu - grafit naturalny - grafit syntetyczny - kaolin - krzemionka bezpostaciowa i syntetyczna - pyły drewna - pyły mąki - pyły niesklasyfikowane ze względu na toksyczność - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - sadza techniczna - sztuczne włókna mineralne z wyjątkiem ogniotrwałych włókien ceramicznych - talk - węgiel (kamienny, brunatny) - węglan magnezu wapnia (dolomit) - węglik krzemu, niewłóknisty Zakres: (0,1 – 36,8) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna - apatyty i fosforyty - cement portlandzki - ditlenek tytanu - grafit naturalny - grafit syntetyczny - kaolin - krzemionka bezpostaciowa i syntetyczna - pyly drewna - pyly maki - pyly niesklasyfikowane ze wzgledu na toksycznosc - pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - sadza techniczna - sztuczne wlokna mineralne z wyjatkiem ogniotrwalych wlokien ceramicznych - talk - wegiel (kamienny, brunatny) - weglan magnezu wapnia (dolomit) - weglik krzemu, niewloknisty Zakres: (0,1 – 36,8) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction - apatites and phosphorites - Portland cement - titanium dioxide - natural graphite - synthetic graphite - kaolin - amorphous and synthetic silica - wood dust - flour dust - dusts not classified according to toxicity - organic dusts of animal and plant origin except wood and flour dust - carbon black - man-made mineral fibres except refractory ceramic fibres - talc - coal (hard, brown) - magnesium calcium carbonate (dolomite) - silicon carbide, non-fibrous Range: (0,1 – 36,8) mg/m3 Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04507:2022-05+Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252ea7","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - apatyty i fosforyty - cement portlandzki - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - talk - węgiel (kamienny, brunatny) Zakres: (0,1 – 14,62) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – respirable fraction - apatites and phosphorites - Portland cement - natural graphite - amorphous and synthetic silica - organic dusts of animal and plant origin except wood and flour dust - talc - coal (hard, brown) Range: (0,1 – 14,62) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - apatyty i fosforyty - cement portlandzki - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - talk - węgiel (kamienny, brunatny) Zakres: (0,1 – 14,62) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04508:2022-05+Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05+Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna - apatyty i fosforyty - cement portlandzki - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - talk - węgiel (kamienny, brunatny) Zakres: (0,1 – 14,62) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna - apatyty i fosforyty - cement portlandzki - grafit naturalny - krzemionka bezpostaciowa i syntetyczna - pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - talk - wegiel (kamienny, brunatny) Zakres: (0,1 – 14,62) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05+Ap1:2022-08","categories":["environment","construction"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction - apatites and phosphorites - Portland cement - natural graphite - amorphous and synthetic silica - organic dusts of animal and plant origin except wood and flour dust - talc - coal (hard, brown) Range: (0,1 – 14,62) mg/m3 Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04508:2022-05+Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252ea8","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie tlenku węgla Zakres (2,32 – 232) mg/m3 (2 – 200) ppm Metoda elektrochemiczna","methodology_en":"Carbon monoxide concentration Range (2,32 – 232) mg/m3 (2 – 200) ppm Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres (2,32 – 232) mg/m3 (2 – 200) ppm Metoda elektrochemiczna","reference":"IB-5.5.7 wydanie 8 z dnia 30.09.2022 r.","norm_bases":["IB-5.5.7 wydanie 8 z dnia 30.09.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie tlenku węgla Zakres (2,32 – 232) mg/m3 (2 – 200) ppm Metoda elektrochemiczna IB-5.5.7 wydanie 8 z dnia 30.09.2022 r. Srodowisko pracy - powietrze Stezenie tlenku wegla Zakres (2,32 – 232) mg/m3 (2 – 200) ppm Metoda elektrochemiczna IB-5.5.7 wydanie 8 z dnia 30.09.2022 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Carbon monoxide concentration Range (2,32 – 232) mg/m3 (2 – 200) ppm Electrochemical method IB-5.5.7 wydanie 8 z dnia 30.09.2022 r.","search_zh":"工作场所环境 — 空气 IB-5.5.7 wydanie 8 z dnia 30.09.2022 r.","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252ea9","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie tlenku azotu Zakres (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Metoda elektrochemiczna","methodology_en":"Nitrogen monoxide concentration Range (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu Zakres (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Metoda elektrochemiczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie tlenku azotu Zakres (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Metoda elektrochemiczna Srodowisko pracy - powietrze Stezenie tlenku azotu Zakres (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Metoda elektrochemiczna","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Nitrogen monoxide concentration Range (0,25 – 8,75) mg/m3 (0,2 – 7) ppm Electrochemical method","search_zh":"工作场所环境 — 空气","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252eaa","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie ditlenku azotu Zakres (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Metoda elektrochemiczna","methodology_en":"Nitrogen dioxide concentration Range (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ditlenku azotu Zakres (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Metoda elektrochemiczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie ditlenku azotu Zakres (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Metoda elektrochemiczna Srodowisko pracy - powietrze Stezenie ditlenku azotu Zakres (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Metoda elektrochemiczna","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Nitrogen dioxide concentration Range (0,38 – 9,55) mg/m3 (0,2 – 5) ppm Electrochemical method","search_zh":"工作场所环境 — 空气","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55fc9af9f73f38252eab","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (50 – 135) dB Szczytowy poziom dźwięku C Zakres: (50 – 138) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (50 – 135) dB C-weighted peak sound level Range: (50 – 138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (50 – 135) dB Szczytowy poziom dźwięku C Zakres: (50 – 138) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (50 – 135) dB Szczytowy poziom dźwięku C Zakres: (50 – 138) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (50 – 135) dB Szczytowy poziom dzwieku C Zakres: (50 – 138) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 punkt 10 oraz strategie 3 punkt 11","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (50 – 135) dB C-weighted peak sound level Range: (50 – 138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11","search_zh":"工作场所环境 — 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 punkt 10 oraz strategię 3 punkt 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55fc9af9f73f38252eac","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： — 8 小时日工作时间 — 平均每周工作时间（计算值）","test_object_zh":"工作场所环境 — 噪声","methodology_zh":"噪声暴露级，参照： — 8 小时日工作时间 — 平均每周工作时间（计算值）"},{"_id":"6a5a55fc9af9f73f38252ead","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (5 – 5 000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance Range: (5 – 5 000) lx Direct measurement method PN-83/E-04040.03","search_zh":"工作场所环境 — 室内电气照明 照度 范围：(5 – 5 000) lx 直接测量法 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明","methodology_zh":"照度 范围：(5 – 5 000) lx 直接测量法"},{"_id":"6a5a55fc9af9f73f38252eae","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55fc9af9f73f38252eaf","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment - outdoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (5 - 5 000) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (5 - 5 000) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (5 - 5 000) Ix Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Natężenie oświetlenia Zakres: (5 - 5 000) Ix Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne na zewnatrz Natezenie oswietlenia Zakres: (5 - 5 000) Ix Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - outdoor electric lighting Illuminance Range: (5 - 5 000) Ix Direct measurement method PN-83/E-04040.03","search_zh":"工作场所环境 — 室外电气照明 照度 范围：(5 - 5 000) lx 直接测量法 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室外电气照明","methodology_zh":"照度 范围：(5 - 5 000) lx 直接测量法"},{"_id":"6a5a55fc9af9f73f38252eb0","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment - outdoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - outdoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室外电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a5a55fc9af9f73f38252eb1","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment - outdoor electric lighting","methodology":"Zróżnicowanie natężenia oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zróżnicowanie natężenia oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne na zewnątrz Zróżnicowanie natężenia oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie elektryczne na zewnatrz Zroznicowanie natezenia oswietlenia (z obliczen)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - outdoor electric lighting Illuminance uniformity (calculated)","search_zh":"工作场所环境 — 室外电气照明","test_object_zh":"工作场所环境 — 室外电气照明"},{"_id":"6a5a55fc9af9f73f38252eb2","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Natężenie oświetlenia Zakres: (0,5 – 500) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 500) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 500) lx Metoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia Zakres: (0,5 – 500) lx Metoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia Zakres: (0,5 – 500) lx Metoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem punktow 4.2.3","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - emergency lighting Illuminance Range: (0,5 – 500) lx Direct measurement method PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3","search_zh":"工作场所环境 — 应急照明 照度 范围：(0,5 – 500) lx 直接测量法 PN-EN 1838:2013-11 z wyłączeniem punktów 4.2.3","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"照度 范围：(0,5 – 500) lx 直接测量法"},{"_id":"6a5a55fc9af9f73f38252eb3","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen)","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated)","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值）","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5a55fc9af9f73f38252eb4","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) Srodowisko pracy - oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - emergency lighting Illuminance uniformity for the high-risk zone (calculated)","search_zh":"工作场所环境 — 应急照明 高风险区照度均匀度（计算值）","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"高风险区照度均匀度（计算值）"},{"_id":"6a5a55fc9af9f73f38252eb5","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Czas załączenia oświetlenia Zakres: (1 – 80) s.","methodology_en":"Lighting switch-on time Range: (1 – 80) s.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Czas załączenia oświetlenia Zakres: (1 – 80) s.","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Czas załączenia oświetlenia Zakres: (1 – 80) s. Srodowisko pracy - oswietlenie awaryjne Czas zalaczenia oswietlenia Zakres: (1 – 80) s.","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - emergency lighting Lighting switch-on time Range: (1 – 80) s.","search_zh":"工作场所环境 — 应急照明","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5a55fc9af9f73f38252eb6","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","test_object_en":"Workplace environment - emergency lighting","methodology":"Minimalny czas stosowania oświetlenia Zakres: (1 – 7200) s.","methodology_en":"Minimum lighting operating time Range: (1 – 7200) s.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Minimalny czas stosowania oświetlenia Zakres: (1 – 7200) s.","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie awaryjne Minimalny czas stosowania oświetlenia Zakres: (1 – 7200) s. Srodowisko pracy - oswietlenie awaryjne Minimalny czas stosowania oswietlenia Zakres: (1 – 7200) s.","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - emergency lighting Minimum lighting operating time Range: (1 – 7200) s.","search_zh":"工作场所环境 — 应急照明","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a5a55fc9af9f73f38252eb7","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 100) m/s² Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted effective vibration acceleration Range: (0,04 – 100) m/s² Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 100) m/s² Metoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 100) m/s² Metoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,04 – 100) m/s² Metoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,04 – 100) m/s² Direct measurement method PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5a55fc9af9f73f38252eb8","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment - whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń) Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4a , 1.4a , a ) wx wy wz (z obliczen)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated)","search_zh":"工作场所环境 — 全身振动 日暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252eb9","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,1–100) m/s2 Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted effective vibration acceleration Range: (0,1–100) m/s2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,1–100) m/s2 Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,1–100) m/s2 Metoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,1–100) m/s2 Metoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Frequency-weighted effective vibration acceleration Range: (0,1–100) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5a55fc9af9f73f38252eba","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) (z obliczeń) hwx hwy hwz","methodology_en":"Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) (calculated) hwx hwy hwz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) (z obliczeń) hwx hwy hwz","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) (z obliczeń) hwx hwy hwz Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a , a ) (z obliczen) hwx hwy hwz","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s., frequency-weighted vibration accelerations, determined for the three directional components (a , a , a ) (calculated) hwx hwy hwz","search_zh":"工作场所环境 — 手传振动","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5a55fc9af9f73f38252ebb","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 15) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 15) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 15) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 15) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 15) °C Wilgotnosc powietrza Zakres: (20 – 90) % Predkosc powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – cold microclimate Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 15) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method PN-EN ISO 11079:2008","search_zh":"工作场所环境 — 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5a55fc9af9f73f38252ebc","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Wskaźnik t wc Wskaźnik IREQ min Wskaźnik IREQ neutral (z obliczeń)","methodology_en":"t wc index IREQ min index IREQ neutral index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik t wc Wskaźnik IREQ min Wskaźnik IREQ neutral (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik t wc Wskaźnik IREQ min Wskaźnik IREQ neutral (z obliczeń) Srodowisko pracy – mikroklimat zimny Wskaznik t wc Wskaznik IREQ min Wskaznik IREQ neutral (z obliczen)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – cold microclimate t wc index IREQ min index IREQ neutral index (calculated)","search_zh":"工作场所环境 — 低温微气候","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5a55fc9af9f73f38252ebd","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 30) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 30) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 30) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006","norm_bases":["PN-EN ISO 7730:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 30) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 30) °C Wilgotnosc powietrza Zakres: (20 – 90) % Predkosc powietrza Zakres: (0,15 – 5) m/s Metoda pomiarowa bezposrednia PN-EN ISO 7730:2006","categories":["environment"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – moderate microclimate Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 30) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5) m/s Direct measurement method PN-EN ISO 7730:2006","search_zh":"工作场所环境 — 中等微气候 PN-EN ISO 7730:2006","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5a55fc9af9f73f38252ebe","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV Wskaźnik PPD (z obliczeń) Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV Wskaznik PPD (z obliczen)","categories":["environment"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – moderate microclimate PMV index PPD index (calculated)","search_zh":"工作场所环境 — 中等微气候 PMV 指数 PPD 指数（计算值）","test_object_zh":"工作场所环境 — 中等微气候","methodology_zh":"PMV 指数 PPD 指数（计算值）"},{"_id":"6a5a55fc9af9f73f38252ebf","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Temperatura powietrza Zakres: (10 – 60) °C Temperatura poczernionej kuli Zakres: (10 – 60) °C Temperatura wilgotna naturalna Zakres: (10 – 50) °C Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 – 60) °C Blackened globe temperature Range: (10 – 60) °C Natural wet bulb temperature Range: (10 – 50) °C Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 – 60) °C Temperatura poczernionej kuli Zakres: (10 – 60) °C Temperatura wilgotna naturalna Zakres: (10 – 50) °C Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza Zakres: (10 – 60) °C Temperatura poczernionej kuli Zakres: (10 – 60) °C Temperatura wilgotna naturalna Zakres: (10 – 50) °C Metoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza Zakres: (10 – 60) °C Temperatura poczernionej kuli Zakres: (10 – 60) °C Temperatura wilgotna naturalna Zakres: (10 – 50) °C Metoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hot microclimate Air temperature Range: (10 – 60) °C Blackened globe temperature Range: (10 – 60) °C Natural wet bulb temperature Range: (10 – 50) °C Direct measurement method PN-EN ISO 7243:2018-01","search_zh":"工作场所环境 — 高温微气候 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5a55fc9af9f73f38252ec0","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń)","methodology_en":"WBGT index WBGT eff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń) Srodowisko pracy – mikroklimat goracy Wskaznik WBGT Wskaznik WBGT eff (z obliczen)","categories":["environment"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hot microclimate WBGT index WBGT eff index (calculated)","search_zh":"工作场所环境 — 高温微气候 WBGT 指数；WBGT eff 指数（由计算得出）","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGT 指数；WBGT eff 指数（由计算得出）"},{"_id":"6a5a55fc9af9f73f38252ec1","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","test_object_en":"Workplace environment – energy expenditure","methodology":"Temperatura powietrza Zakres: (10 – 60) °C Przepływ powietrza Zakres: (10 – 60) dm3/min. Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 – 60) °C Air flow Range: (10 – 60) dm3/min. Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 – 60) °C Przepływ powietrza Zakres: (10 – 60) dm3/min. Metoda pomiarowa bezpośrednia","reference":"IB-5.5.9 wydanie 4 z dn. 01.07.2024 r.","norm_bases":["IB-5.5.9 wydanie 4 z dn. 01.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – wydatek energetyczny Temperatura powietrza Zakres: (10 – 60) °C Przepływ powietrza Zakres: (10 – 60) dm3/min. Metoda pomiarowa bezpośrednia IB-5.5.9 wydanie 4 z dn. 01.07.2024 r. Srodowisko pracy – wydatek energetyczny Temperatura powietrza Zakres: (10 – 60) °C Przeplyw powietrza Zakres: (10 – 60) dm3/min. Metoda pomiarowa bezposrednia IB-5.5.9 wydanie 4 z dn. 01.07.2024 r.","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – energy expenditure Air temperature Range: (10 – 60) °C Air flow Range: (10 – 60) dm3/min. Direct measurement method IB-5.5.9 wydanie 4 z dn. 01.07.2024 r.","search_zh":"工作场所环境 — 能量消耗 IB-5.5.9 wydanie 4 z dn. 01.07.2024 r.","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a55fc9af9f73f38252ec2","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko pracy – wydatek energetyczny","test_object_en":"Workplace environment – energy expenditure","methodology":"Wydatek energetyczny (z obliczeń)","methodology_en":"Energy expenditure (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczeń) Srodowisko pracy – wydatek energetyczny Wydatek energetyczny (z obliczen)","categories":["environment"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – energy expenditure Energy expenditure (calculated)","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a55fc9af9f73f38252ec3","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A Zakres: (24 - 135) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level Range: (24 - 135) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Zakres: (24 - 135) dB Metoda pomiarowa bezpośrednia","reference":"Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F","norm_bases":["Nr 7","enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023","eniem pkt. F"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A Zakres: (24 - 135) dB Metoda pomiarowa bezpośrednia Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A Zakres: (24 - 135) dB Metoda pomiarowa bezposrednia Nr 7 | enia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level Range: (24 - 135) dB Direct measurement method Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 范围：(24 - 135) dB 直接测量法 Nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 | eniem pkt. F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","methodology_zh":"A 计权等效声级 范围：(24 - 135) dB 直接测量法"},{"_id":"6a5a55fc9af9f73f38252ec4","lab_id":"69ad52a3de79e566650fb7a2","country":"PL","accr_number":"AB 1475","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","methodology_en":"A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami L i L AeqD AeqN (z obliczeń) Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami L i L AeqD AeqN (z obliczen)","categories":["environment"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated)","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声","methodology_zh":"参考时间 T 的 A 计权等效声级，以 L 与 L AeqD AeqN 指标表示（计算值）"}],"has_pdf":true}