🇵🇱 GMINA MIASTA ŁOWICZA PL
Water & wastewaterMicrobiology
GMINA MIASTA ŁOWICZA is a laboratory accredited by PCA under number AB 1466 (Łowicz, Poland). Its accreditation scope covers 26 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water, water intended for human consumption, Water, water intended for human consumption, wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Electrochemical method, Optical method.
At a glance
- Accreditation number: PCA AB 1466
- Methods in scope: 26
- Types of test objects: 5
- Techniques used: 10
- City: Łowicz, Poland
- Accreditation number
- AB 1466
- Accreditation body
- PCA
- Address
- Stary Rynek 1, 99-400 Łowicz, ZAKŁAD USŁUG KOMUNALNYCH W ŁOWICZU, ul. Armii Krajowej 2b
- City
- Łowicz, Poland
What this laboratory tests (5)
- Wastewater — 11 methods
- Water, water intended for human consumption — 7 methods
- Water, water intended for human consumption, wastewater — 5 methods
- Water intended for human consumption — 2 methods
- Sewage sludge — 1 method
Analytical techniques used (10)
- Spectrophotometric method — 9 methods
- Electrochemical method — 3 methods
- Optical method — 3 methods
- Gravimetric method — 2 methods
- MPN method (Colilert 18 Test) — 2 methods
- Conductometric method — 1 method
- Manual and automatic method — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Potentiometric method — 1 method
Laboratory locations
- ZAKŁAD USŁUG KOMUNALNYCH W ŁOWICZU — ul. Armii Krajowej 2b
- Laboratorium —
Accreditation scope — test methods (26)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 3 | Water, water intended for human consumption | Most probable number, Escherichia coli | MPN method (Colilert 18 Test) | PN-EN ISO 9308-2:2014-06 | |
| 4 | Water, water intended for human consumption | Most probable number of coliform bacteria | MPN method (Colilert 18 Test) | PN-EN ISO 9308-2:2014-06 | |
| 5 | Water, water intended for human consumption | Manganese concentration Range (0,02 – 1,00) mg/dm3 |
Spectrophotometric method | PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032 | |
| 6 | Water, water intended for human consumption | Electrical conductivity Range 147 μS/cm – 12,88 mS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 7 | Water, water intended for human consumption | Iron concentration Range (0,020 – 5,00) mg/dm3 |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 8 | Water, water intended for human consumption | Turbidity Range (0,10 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 9 | Water, water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 10 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 11 | Wastewater | Chemical oxygen demand - COD-Cr Range (20,0 – 50000) mg/dm3 O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 12 | Wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/dm3 O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 13 | Wastewater | Total suspended solids (TSS) Range (2,0 – 2000) mg/dm3 |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 14 | Wastewater | Total phosphorus concentration Range (0,100 – 20,0) mg/dm3 |
Spectrophotometric method | PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350 | |
| 15 | Wastewater | Total nitrogen concentration Range (2,50 – 300) mg/dm3 |
Spectrophotometric method | PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338 | |
| 16 | Wastewater | Biochemical oxygen demand (BOD5) Range (3 – 6000) mg/dm3 O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 17 | Wastewater | Biochemical oxygen demand BOD2+5 Range (3 – 6000) mg/dm3 O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 18 | Wastewater | Biochemical oxygen demand Range (0,50 – 6,0) mg/dm3 O2 |
Optical method | PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021 | |
| 19 | Wastewater | Biochemical oxygen demand BOD2+5 Range (3 – 6000) mg/dm3 O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 20 | Wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/dm3 O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 21 | Water, water intended for human consumption, wastewater | Total phosphorus concentration Range (0,040 – 80,0) mg/dm3 |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 | |
| 22 | Water, water intended for human consumption, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 23 | Water, water intended for human consumption, wastewater | Nitrite concentration Range (0,05 – 2,00) mg/dm3 Nitrite nitrogen concentration Range (0,015 – 0,600) mg/dm3 |
Spectrophotometric method | PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341 | |
| 24 | Water, water intended for human consumption, wastewater | Nitrate concentration Range (1,0 – 60,0) mg/dm3 Nitrate nitrogen concentration Range (0,23 – 13,50) mg/dm3 |
Spectrophotometric method | PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339 | |
| 25 | Water, water intended for human consumption, wastewater | Ammonium ion concentration Range (0,02 – 60,0) mg/dm3 Ammonium nitrogen concentration Range (0,015 – 47,0) mg/dm3 |
Spectrophotometric method | PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305 | |
| 26 | Sewage sludge | Dry residue Range (0,5 – 99,5)% |
Gravimetric method | PN-EN 12880:2004 | |
Reference standards (22)
PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032
PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305
PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339
PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341
PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338
PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06