{"lab":{"_id":"69ad52a3de79e566650fb796","accr_number":"AB 1466","country":"PL","accr_body":"PCA","address":"Stary Rynek 1, 99-400 Łowicz, ZAKŁAD USŁUG KOMUNALNYCH W ŁOWICZU, ul. Armii Krajowej 2b","categories":["water","microbiology"],"city":"Łowicz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":26,"name":"GMINA MIASTA ŁOWICZA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1466.pdf"],"scope_summary":"","search_text":"gmina miasta łowicza stary rynek 1, 99-400 łowicz, zakład usług komunalnych w łowiczu, ul. armii krajowej 2b water microbiology other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:37.184Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:00:47.796Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201466,podmiot.html","parse_date":"2026-08-13T08:00:47.796Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Physical properties and sampling of drinking water, sewage"},{"codes":"N/28; N/32","pl":"Badania właściwości fizycznych wody, osadów","en":"Physical properties of water, sediments"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"}],"issue":{"no":"13","date":"15.07.2026"},"map_coord":[52.126774,19.95166],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD USŁUG KOMUNALNYCH W ŁOWICZU","address":"ul. Armii Krajowej 2b","city":null,"postal":null},{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/828b31e7d84730605745cc3e46c7b72f/AB%201466.pdf","has_en":true,"category_counts":{"water":26,"microbiology":3},"category_scores":{"water":23.31,"microbiology":0.31},"has_zh":true,"lab_locations_zh":[{"name":"ZAKŁAD USŁUG KOMUNALNYCH W ŁOWICZU","address":"ul. Armii Krajowej 2b","city":null,"postal":null},{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d79af0636ba417e41ac11","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7d79af0636ba417e41ac12","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7d79af0636ba417e41ac13","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL (Test Colilert 18)","techniques":["Metoda NPL (Test Colilert 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number, Escherichia coli","search_en":"Water, water intended for human consumption Most probable number, Escherichia coli MPN method (Colilert 18 Test) Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert 18 Test)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） MPN 法（Colilert 18 测试） 实验室 PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水","technique_zh":"MPN 法（Colilert 18 测试）"},{"_id":"6a7d79af0636ba417e41ac14","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL (Test Colilert 18)","techniques":["Metoda NPL (Test Colilert 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (Test Colilert 18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 Test) Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert 18 Test)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） MPN 法（Colilert 18 测试） 实验室 PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水","technique_zh":"MPN 法（Colilert 18 测试）"},{"_id":"6a7d79af0636ba417e41ac15","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,02 – 1,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,02 – 1,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032","norm_bases":["PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,02 – 1,00) mg/dm3\nMetoda spektrofotometryczna PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,02 – 1,00) mg/dm3\nMetoda spektrofotometryczna PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,00) mg/dm3"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Range PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,00) mg/dm3"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室 范围 PB-03 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCW032","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79af0636ba417e41ac16","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"147 μS/cm – 12,88 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 147 μS/cm – 12,88 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 147 μS/cm – 12,88 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 147 μS/cm – 12,88 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"147 μS/cm – 12,88 mS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"147 μS/cm – 12,88 mS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79af0636ba417e41ac17","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,020 – 5,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,020 – 5,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,020 – 5,00) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,020 – 5,00) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,020 – 5,00) mg/dm3"}],"search_en":"Water, water intended for human consumption Iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 5,00) mg/dm3"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79af0636ba417e41ac18","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 40) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79af0636ba417e41ac19","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water, water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a7d79af0636ba417e41ac1a","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 实验室 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a7d79af0636ba417e41ac1b","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(20,0 – 50000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (20,0 – 50000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (20,0 – 50000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (20,0 – 50000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(20,0 – 50000) mg/dm3 O2"}],"search_en":"Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(20,0 – 50000) mg/dm3 O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d79af0636ba417e41ac1c","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac1d","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/dm3"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/dm3"}],"search_zh":"污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac1e","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,100 – 20,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,100 – 20,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350","norm_bases":["PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,100 – 20,0) mg/dm3\nMetoda spektrofotometryczna PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350 Scieki Stezenie fosforu ogolnego\nZakres (0,100 – 20,0) mg/dm3\nMetoda spektrofotometryczna PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,100 – 20,0) mg/dm3"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 20,0) mg/dm3"}],"search_zh":"污水 总磷浓度 分光光度法 实验室 范围 PB-11 wyd.5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 349, LCK 350","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac1f","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(2,50 – 300) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (2,50 – 300) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338","norm_bases":["PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (2,50 – 300) mg/dm3\nMetoda spektrofotometryczna PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338 Scieki Stezenie azotu ogolnego\nZakres (2,50 – 300) mg/dm3\nMetoda spektrofotometryczna PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,50 – 300) mg/dm3"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(2,50 – 300) mg/dm3"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB-10 wyd. 6 z dnia 03.03.2025 na podstawie testu Hach Lange LCK 138, LCK 238, LCK 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac20","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu (BZT5)","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu (BZT5)\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand (BOD5)","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand (BOD5) Optical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/dm3 O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d79af0636ba417e41ac21","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT2+5"},{"name":"Zakres","range":"(3 – 6000) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD2+5"},{"name":"Range","range":"(3 – 6000) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Laboratory BOD2+5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT2+5"},{"name":"范围","range":"(3 – 6000) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 光学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac22","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"Zakres","range":"(0,50 – 6,0) mg/dm3 O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"Range","range":"(0,50 – 6,0) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Laboratory Range PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021","technique_en":"Optical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"范围","range":"(0,50 – 6,0) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 光学法 实验室 范围 PN-EN 1899-2:2002 z wyłączeniem punktu 7.2.1, 7.2.2 + PB-12 wyd. 2 z dnia 01.04.2021","technique_zh":"光学法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac23","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT2+5"},{"name":"Zakres","range":"(3 – 6000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT2+5\nZakres (3 – 6000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD2+5"},{"name":"Range","range":"(3 – 6000) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD2+5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT2+5"},{"name":"范围","range":"(3 – 6000) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac24","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/dm3 O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/dm3 O2"}],"search_zh":"污水 生化需氧量 电化学法 实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a7d79af0636ba417e41ac25","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 80,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 80,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 80,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010 Woda, woda do spozycia przez ludzi, scieki Stezenie fosforu ogolnego\nZakres (0,040 – 80,0) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 80,0) mg/dm3"}],"search_en":"Water, water intended for human consumption, wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 80,0) mg/dm3"}],"search_zh":"水、生活饮用水、污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 pkt 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d79af0636ba417e41ac26","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d79af0636ba417e41ac27","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/dm3"},{"name":"Stężenie azotu azotynowego"},{"name":"Zakres","range":"(0,015 – 0,600) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,05 – 2,00) mg/dm3\nStężenie azotu azotynowego\nZakres (0,015 – 0,600) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341","norm_bases":["PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotynów\nZakres:\nZakres (0,05 – 2,00) mg/dm3\nStężenie azotu azotynowego\nZakres (0,015 – 0,600) mg/dm3\nMetoda spektrofotometryczna PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341 Woda, woda do spozycia przez ludzi, scieki Stezenie azotynow\nZakres:\nZakres (0,05 – 2,00) mg/dm3\nStezenie azotu azotynowego\nZakres (0,015 – 0,600) mg/dm3\nMetoda spektrofotometryczna PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/dm3"},{"name":"Nitrite nitrogen concentration"},{"name":"Range","range":"(0,015 – 0,600) mg/dm3"}],"search_en":"Water, water intended for human consumption, wastewater Nitrite concentration Spectrophotometric method Laboratory Range Nitrite nitrogen concentration Range PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/dm3"},{"name":"亚硝态氮浓度"},{"name":"范围","range":"(0,015 – 0,600) mg/dm3"}],"search_zh":"水、生活饮用水、污水 亚硝酸盐浓度 分光光度法 实验室 范围 亚硝态氮浓度 范围 PB-09 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 341","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d79af0636ba417e41ac28","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,0 – 60,0) mg/dm3"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,23 – 13,50) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nZakres (1,0 – 60,0) mg/dm3\nStężenie azotu azotanowego\nZakres (0,23 – 13,50) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339","norm_bases":["PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotanów\nZakres:\nZakres (1,0 – 60,0) mg/dm3\nStężenie azotu azotanowego\nZakres (0,23 – 13,50) mg/dm3\nMetoda spektrofotometryczna PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339 Woda, woda do spozycia przez ludzi, scieki Stezenie azotanow\nZakres:\nZakres (1,0 – 60,0) mg/dm3\nStezenie azotu azotanowego\nZakres (0,23 – 13,50) mg/dm3\nMetoda spektrofotometryczna PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,0 – 60,0) mg/dm3"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,23 – 13,50) mg/dm3"}],"search_en":"Water, water intended for human consumption, wastewater Nitrate concentration Spectrophotometric method Laboratory Range Nitrate nitrogen concentration Range PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 60,0) mg/dm3"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,23 – 13,50) mg/dm3"}],"search_zh":"水、生活饮用水、污水 硝酸盐浓度 分光光度法 实验室 范围 硝态氮浓度 范围 PB-08 wyd. 5 z dnia 30.03.2026 na podstawie testu Hach Lange LCK 339","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d79af0636ba417e41ac29","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,02 – 60,0) mg/dm3"},{"name":"Stężenie azotu amonowego"},{"name":"Zakres","range":"(0,015 – 47,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,02 – 60,0) mg/dm3\nStężenie azotu amonowego\nZakres (0,015 – 47,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305","norm_bases":["PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie jonu amonowego\nZakres:\nZakres (0,02 – 60,0) mg/dm3\nStężenie azotu amonowego\nZakres (0,015 – 47,0) mg/dm3\nMetoda spektrofotometryczna PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305 Woda, woda do spozycia przez ludzi, scieki Stezenie jonu amonowego\nZakres:\nZakres (0,02 – 60,0) mg/dm3\nStezenie azotu amonowego\nZakres (0,015 – 47,0) mg/dm3\nMetoda spektrofotometryczna PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,02 – 60,0) mg/dm3"},{"name":"Ammonium nitrogen concentration"},{"name":"Range","range":"(0,015 – 47,0) mg/dm3"}],"search_en":"Water, water intended for human consumption, wastewater Ammonium ion concentration Spectrophotometric method Laboratory Range Ammonium nitrogen concentration Range PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 60,0) mg/dm3"},{"name":"氨氮浓度"},{"name":"范围","range":"(0,015 – 47,0) mg/dm3"}],"search_zh":"水、生活饮用水、污水 铵离子浓度 分光光度法 实验室 范围 氨氮浓度 范围 PB-07 wyd. 4 z dnia 01.04.2021 na podstawie testu Hach Lange LCK 303, LCK 304, LCK 305","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a7d79af0636ba417e41ac2a","lab_id":"69ad52a3de79e566650fb796","country":"PL","accr_number":"AB 1466","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,5 – 99,5)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,5 – 99,5)%\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres (0,5 – 99,5)%\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc\nZakres (0,5 – 99,5)%\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,5 – 99,5)%"}],"search_en":"Sewage sludge Dry residue Gravimetric method Laboratory Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5)%"}],"search_zh":"污泥 干残渣 重量法 实验室 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣"}],"has_pdf":true}