🇵🇱 INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY PL
Water & wastewater
INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 143 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Water & wastewater. Test objects include: Central heating radiators supplied with water or steam at a tempera…, Fittings for water supply and central heating installations with a…, Two-way thermostatic valves with or without presetting for use with….
At a glance
- Accreditation number: PCA AB 143
- Methods in scope: 17
- Types of test objects: 3
- City: Warszawa, Poland
- Accreditation number
- AB 143
- Accreditation body
- PCA
- Address
- ul. Mory 8, 01-330 Warszawa, LABORATORIUM BADAWCZE GRZEJNIKÓW I ARMATURY, ul. Wilcza 8
- City
- Warszawa, Poland
What this laboratory tests (3)
- Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source — 8 methods
- Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC — 5 methods
- Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 — 4 methods
Accreditation scope — test methods (17)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Coating durability Range: (0 - 5) grades Measurement method: cross-cut | PN-EN ISO 2409:2021-03 p.8.2 „N | ||
| 2 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Tightness under hydraulic pressure Range: (0,2 - 6,0) MPa Measurement method: Direct measurement | PN-EN 442-1:2015-02 p. 5.4 „N” | ||
| 3 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Resistance to hydraulic pressure Range: (0,2 - 6,0) MPa Measurement method: direct measurement | PN-EN 442-1:2015-02 p. 5.6 „N” | ||
| 4 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Heat output Range: (50 - 5000) W Measurement method: gravimetric | PN-EN 442-2:2015-02 p. 5.4.2 | ||
| 5 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Linear dimensions Range: (0 ÷ 3000) mm Method: direct measurement | PN-EN 442-2:2015-02 p. 4.3.3 „N” | ||
| 6 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Mass Range: (0,0 - 100) kg Method: direct measurement | |||
| 7 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Water capacity Range: (0,0 - 50,0) l Method: direct measurement | |||
| 8 | Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source | Durability (corrosion resistance) Measurement method: indirect measurement | PN-EN 442-1:2015-02 p. 5.9 „N” | ||
| 9 | Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 | Linear dimensions Range: (0 - 500) mm Method: direct measurement | PN-EN 215:2020-01 zał. A | ||
| 10 | Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 | Hydraulic pressure strength and tightness Range: (0,2 - 6,0) MPa | PN-EN 215:2020-01 | ||
| 11 | Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 | Flexural strength Range: (30 - 250) Nm | PN-EN 215:2020-01 | ||
| 12 | Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 | Characteristics and technical-operational properties of thermostatic valves | PN-EN 215:2020-01; p. 6.2 z wył. 6.2.1.5, 6.4.1 (od 6.4.1.2 do 6.4.1.10) | ||
| 13 | Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC | Linear dimensions Range: (0 - 500) mm Method: direct measurement | PN-M-75002:2016-10 | PN-M-75019:2016-10 | ||
| 14 | Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC | Hydraulic tightness Range: (0,2 - 4,0) MPa | PN-M-75002:2016-10 | ||
| 15 | Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC | Flow (flow capacity) Range: (0,01 - 2,5) m3/h Diameters up to DN 20 | PN-M-75002:2016-10, p. 6.2.8 z wył. klasy przepustowości V B | ||
| 16 | Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC | Hydraulic pressure strength Range: (0,2 - 4,0) MPa | PN-M-75002:2016-10 | ||
| 17 | Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC | Flow coefficient K V Range: up to 10 m3/h | PN-M-75019:2016-10 | ||
Reference standards (12)
PN-EN 215:2020-01
PN-EN 215:2020-01 zał. A
PN-EN 215:2020-01; p. 6.2 z wył. 6.2.1.5, 6.4.1 (od 6.4.1.2 do 6.4.1.10)
PN-EN 442-1:2015-02 p. 5.4 „N”
PN-EN 442-1:2015-02 p. 5.6 „N”
PN-EN 442-1:2015-02 p. 5.9 „N”
PN-EN 442-2:2015-02 p. 4.3.3 „N”
PN-EN 442-2:2015-02 p. 5.4.2
PN-EN ISO 2409:2021-03 p.8.2 „N
PN-M-75002:2016-10
PN-M-75002:2016-10, p. 6.2.8 z wył. klasy przepustowości V B
PN-M-75019:2016-10