🇵🇱 INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY PL

PCA AB 143 • Warszawa, Poland • 17 methods

Water & wastewater

INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 143 (Warszawa, Poland). Its accreditation scope covers 17 test methods in the following areas: Water & wastewater. Test objects include: Central heating radiators supplied with water or steam at a tempera…, Fittings for water supply and central heating installations with a…, Two-way thermostatic valves with or without presetting for use with….

At a glance

  • Accreditation number: PCA AB 143
  • Methods in scope: 17
  • Types of test objects: 3
  • City: Warszawa, Poland
Accreditation number
AB 143
Accreditation body
PCA
Address
ul. Mory 8, 01-330 Warszawa, LABORATORIUM BADAWCZE GRZEJNIKÓW I ARMATURY, ul. Wilcza 8
City
Warszawa, Poland

What this laboratory tests (3)

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Coating durability Range: (0 - 5) grades Measurement method: cross-cut PN-EN ISO 2409:2021-03 p.8.2 „N
2 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Tightness under hydraulic pressure Range: (0,2 - 6,0) MPa Measurement method: Direct measurement PN-EN 442-1:2015-02 p. 5.4 „N”
3 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Resistance to hydraulic pressure Range: (0,2 - 6,0) MPa Measurement method: direct measurement PN-EN 442-1:2015-02 p. 5.6 „N”
4 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Heat output Range: (50 - 5000) W Measurement method: gravimetric PN-EN 442-2:2015-02 p. 5.4.2
5 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Linear dimensions Range: (0 ÷ 3000) mm Method: direct measurement PN-EN 442-2:2015-02 p. 4.3.3 „N”
6 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Mass Range: (0,0 - 100) kg Method: direct measurement
7 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Water capacity Range: (0,0 - 50,0) l Method: direct measurement
8 Central heating radiators supplied with water or steam at a temperature up to 120 °C from a separate heat source Durability (corrosion resistance) Measurement method: indirect measurement PN-EN 442-1:2015-02 p. 5.9 „N”
9 Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 Linear dimensions Range: (0 - 500) mm Method: direct measurement PN-EN 215:2020-01 zał. A
10 Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 Hydraulic pressure strength and tightness Range: (0,2 - 6,0) MPa PN-EN 215:2020-01
11 Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 Flexural strength Range: (30 - 250) Nm PN-EN 215:2020-01
12 Two-way thermostatic valves with or without presetting for use with radiators in hot water central heating systems with temperature up to 120 °C and nominal pressure up to PN 10 Characteristics and technical-operational properties of thermostatic valves PN-EN 215:2020-01; p. 6.2 z wył. 6.2.1.5, 6.4.1 (od 6.4.1.2 do 6.4.1.10)
13 Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC Linear dimensions Range: (0 - 500) mm Method: direct measurement PN-M-75002:2016-10 | PN-M-75019:2016-10
14 Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC Hydraulic tightness Range: (0,2 - 4,0) MPa PN-M-75002:2016-10
15 Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC Flow (flow capacity) Range: (0,01 - 2,5) m3/h Diameters up to DN 20 PN-M-75002:2016-10, p. 6.2.8 z wył. klasy przepustowości V B
16 Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC Hydraulic pressure strength Range: (0,2 - 4,0) MPa PN-M-75002:2016-10
17 Fittings for water supply and central heating installations with a nominal pressure of 1 MPa and temperature up to 120 oC Flow coefficient K V Range: up to 10 m3/h PN-M-75019:2016-10

Reference standards (12)

PN-EN 215:2020-01
PN-EN 215:2020-01 zał. A
PN-EN 215:2020-01; p. 6.2 z wył. 6.2.1.5, 6.4.1 (od 6.4.1.2 do 6.4.1.10)
PN-EN 442-1:2015-02 p. 5.4 „N”
PN-EN 442-1:2015-02 p. 5.6 „N”
PN-EN 442-1:2015-02 p. 5.9 „N”
PN-EN 442-2:2015-02 p. 4.3.3 „N”
PN-EN 442-2:2015-02 p. 5.4.2
PN-EN ISO 2409:2021-03 p.8.2 „N
PN-M-75002:2016-10
PN-M-75002:2016-10, p. 6.2.8 z wył. klasy przepustowości V B
PN-M-75019:2016-10