🇵🇱 ENEA WYTWARZANIE Sp. z o.o. PL

PCA AB 1382 • Kozienice, Poland • 27 methods

Environment

ENEA WYTWARZANIE Sp. z o.o. is a laboratory accredited by PCA under number AB 1382 (Kozienice, Poland). Its accreditation scope covers 27 test methods in the following areas: Environment. Test objects include: Waste gases, Automated Measuring Systems (AMS).

At a glance

  • Accreditation number: PCA AB 1382
  • Methods in scope: 27
  • Types of test objects: 2
  • City: Kozienice, Poland
Accreditation number
AB 1382
Accreditation body
PCA
Address
LABORATORIUM BADAŃ FIZYKOCHEMICZNYCH, ul. Aleja Józefa Zielińskiego 1, Świerże Górne, 26-900 Kozienice
City
Kozienice, Poland

What this laboratory tests (2)

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Waste gases Gas velocity and volume flow for differential pressures > 10 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03
2 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994
3 Waste gases Sampling for determination of dust concentration
4 Waste gases Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method
5 Waste gases Dust emission (calculated)
6 Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02
7 Waste gases Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method
8 Waste gases Carbon monoxide concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-EN 15058:2017-04
9 Waste gases CO emission (calculated)
10 Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD) PN-EN 14792:2017-04
11 Waste gases Emission of NO, NOx (NO and NOX calculated as NO2) (calculated)
12 Waste gases Oxygen concentration Range: (0,2 – 21) % Paramagnetic method (PMD) PN-EN 14789:2017-04
13 Waste gases Sampling for the determination of sulfur dioxide concentration PN-EN 14791:2017-04
14 Waste gases SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method
15 Waste gases SO2 emission (calculated)
16 Waste gases Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR) ISO 12039:2019
17 Waste gases CO2 emission (calculated)
18 Waste gases Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method PN-EN 14790:2017-04
19 Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, CO, NO, NOx, O2 , SO2, H2O, CO2 PN-EN 14181:2015
20 Automated Measuring Systems (AMS) Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method PN-Z-04030-7:1994
21 Automated Measuring Systems (AMS) Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method PN-EN 13284-1:2018-02
22 Automated Measuring Systems (AMS) CO concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-EN 15058:2017-04
23 Automated Measuring Systems (AMS) NO, NOx concentration NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD) PN-EN 14792:2017-04
24 Automated Measuring Systems (AMS) O2 concentration Range: (0,2 – 21) % Paramagnetic method (PMD) PN-EN 14789:2017-04
25 Automated Measuring Systems (AMS) SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method PN-EN 14791:2017-04
26 Automated Measuring Systems (AMS) Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR) ISO 12039:2019
27 Automated Measuring Systems (AMS) Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method PN-EN 14790:2017-04

Reference standards (10)

ISO 12039:2019
PN-EN 13284-1:2018-02
PN-EN 14181:2015
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03
PN-Z-04030-7:1994