{"lab":{"_id":"69ad52a3de79e566650fb71a","accr_number":"AB 1382","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ FIZYKOCHEMICZNYCH, ul. Aleja Józefa Zielińskiego 1, Świerże Górne, 26-900 Kozienice","categories":["environment"],"city":"Kozienice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"ENEA WYTWARZANIE Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1382.pdf"],"scope_summary":"","search_text":"enea wytwarzanie sp. z o.o. laboratorium badań fizykochemicznych, ul. aleja józefa zielińskiego 1, świerże górne, 26-900 kozienice other environment","status":"active","updated_at":"2026-03-08T14:50:33.223Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:33.223Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201382,podmiot.html","parse_date":"2026-07-17T16:19:05.418Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"− C/36/P","pl":"− Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"− M/58","pl":"− Badania inne - AST automatycznych systemów monitoringu (AMS)","en":"Other tests - AST of automated measuring systems (AMS)"},{"codes":"− P/36","pl":"− Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"},{"codes":"− G/36","pl":"− Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy odlotowe","en":"Tests concerning environmental engineering (environmental and climatic) – waste gases"},{"codes":"− N/36/P","pl":"− Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling - waste gases"}],"issue":{"no":"16","date":"07.05.2025"},"map_coord":[51.661425,21.470357],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":22,"environment":5},"category_scores":{"other":17.93,"environment":0.93},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f38252704","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 10 Pa Metoda pomiaru ciśnienia różnicowego","methodology_en":"Gas velocity and volume flow for differential pressures > 10 Pa Differential pressure measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Prędkość i strumień objętości gazu dla ciśnień różnicowych > 10 Pa Metoda pomiaru ciśnienia różnicowego","reference":"PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","norm_bases":["PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Prędkość i strumień objętości gazu dla ciśnień różnicowych > 10 Pa Metoda pomiaru ciśnienia różnicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03 Gazy odlotowe Predkosc i strumien objetosci gazu dla cisnien roznicowych > 10 Pa Metoda pomiaru cisnienia roznicowego PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas velocity and volume flow for differential pressures > 10 Pa Differential pressure measurement method PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","search_zh":"废气 PN-EN ISO 16911-1:2013-07 CEN/TR 17078:2017-03","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252705","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量 皮托管法"},{"_id":"6a5a55f99af9f73f38252706","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f99af9f73f38252707","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna","methodology_en":"Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna Gazy odlotowe Stezenie pylu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252708","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a55f99af9f73f38252709","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a55f99af9f73f3825270a","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna","methodology_en":"Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna Gazy odlotowe Stezenie pylu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f3825270b","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku węgla Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon monoxide concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku węgla Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie tlenku wegla Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon monoxide concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-EN 15058:2017-04","search_zh":"废气 PN-EN 15058:2017-04","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f3825270c","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO (z obliczeń)","methodology_en":"CO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) Gazy odlotowe Emisja CO (z obliczen)","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO emission (calculated)","search_zh":"废气 CO 排放量（计算值）","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a5a55f99af9f73f3825270d","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD)","methodology_en":"Concentration of nitrogen monoxide, nitrogen oxides Range: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku azotu, tlenków azotu Zakres: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenku azotu, tlenków azotu Zakres: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenku azotu, tlenkow azotu Zakres: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of nitrogen monoxide, nitrogen oxides Range: NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD) PN-EN 14792:2017-04","search_zh":"废气 PN-EN 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f3825270e","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NO, NOx (NO i NOX w przeliczeniu na NO2) (z obliczeń)","methodology_en":"Emission of NO, NOx (NO and NOX calculated as NO2) (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NO, NOx (NO i NOX w przeliczeniu na NO2) (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NOX w przeliczeniu na NO2) (z obliczeń) Gazy odlotowe Emisja NO, NOx (NO i NOX w przeliczeniu na NO2) (z obliczen)","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NO, NOx (NO and NOX calculated as NO2) (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f3825270f","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD)","methodology_en":"Oxygen concentration Range: (0,2 – 21) % Paramagnetic method (PMD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie tlenu Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Oxygen concentration Range: (0,2 – 21) % Paramagnetic method (PMD) PN-EN 14789:2017-04","search_zh":"废气 PN-EN 14789:2017-04","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252710","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","methodology_en":"Sampling for the determination of sulfur dioxide concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia dwutlenku siarki","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia dwutlenku siarki PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia dwutlenku siarki PN-EN 14791:2017-04","categories":["other"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for the determination of sulfur dioxide concentration PN-EN 14791:2017-04","search_zh":"废气 用于测定二氧化硫浓度的采样 PN-EN 14791:2017-04","test_object_zh":"废气","methodology_zh":"用于测定二氧化硫浓度的采样"},{"_id":"6a5a55f99af9f73f38252711","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa","methodology_en":"SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa Gazy odlotowe Stezenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252712","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja SO2 (z obliczeń)","methodology_en":"SO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja SO2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) Gazy odlotowe Emisja SO2 (z obliczen)","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases SO2 emission (calculated)","search_zh":"废气 SO2 排放量（计算值）","test_object_zh":"废气","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a5a55f99af9f73f38252713","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Gazy odlotowe Stezenie dwutlenku wegla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR) ISO 12039:2019","search_zh":"废气 二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR） ISO 12039:2019","test_object_zh":"废气","methodology_zh":"二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR）"},{"_id":"6a5a55f99af9f73f38252714","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO2 (z obliczeń)","methodology_en":"CO2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO2 (z obliczeń) Gazy odlotowe Emisja CO2 (z obliczen)","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO2 emission (calculated)","search_zh":"废气 CO2 排放（由计算得出）","test_object_zh":"废气","methodology_zh":"CO2 排放（由计算得出）"},{"_id":"6a5a55f99af9f73f38252715","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa","methodology_en":"Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa PN-EN 14790:2017-04 Gazy odlotowe Stezenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa PN-EN 14790:2017-04","categories":["other"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method PN-EN 14790:2017-04","search_zh":"废气 PN-EN 14790:2017-04","test_object_zh":"废气"},{"_id":"6a5a55f99af9f73f38252716","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: pyłu, CO, NO, NOx, O2 , SO2, H2O, CO2","methodology_en":"Annual surveillance test (AST) for: dust, CO, NO, NOx, O2 , SO2, H2O, CO2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: pyłu, CO, NO, NOx, O2 , SO2, H2O, CO2","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pyłu, CO, NO, NOx, O2 , SO2, H2O, CO2 PN-EN 14181:2015 Automatyczne Systemy Monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pylu, CO, NO, NOx, O2 , SO2, H2O, CO2 PN-EN 14181:2015","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) Annual surveillance test (AST) for: dust, CO, NO, NOx, O2 , SO2, H2O, CO2 PN-EN 14181:2015","search_zh":"自动测量系统（AMS） PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f38252717","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna","methodology_en":"Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna PN-Z-04030-7:1994 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu: Zakres: (0,001 − 1) g/m³ Metoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) Dust concentration: Range: (0,001 − 1) g/m³ Gravimetric method PN-Z-04030-7:1994","search_zh":"自动测量系统（AMS） PN-Z-04030-7:1994","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f38252718","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna","methodology_en":"Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pyłu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne Systemy Monitoringu (AMS) Stezenie pylu: Zakres: (0,73 − 50) mg/m³ Metoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) Dust concentration: Range: (0,73 − 50) mg/m³ Gravimetric method PN-EN 13284-1:2018-02","search_zh":"自动测量系统（AMS） PN-EN 13284-1:2018-02","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f38252719","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie CO Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"CO concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie CO Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie CO Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie CO Zakres: (2,0 – 625) mg/m3 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) CO concentration Range: (2,0 – 625) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-EN 15058:2017-04","search_zh":"自动测量系统（AMS） PN-EN 15058:2017-04","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f3825271a","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie NO, NOx NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD)","methodology_en":"NO, NOx concentration NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie NO, NOx NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie NO, NOx NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie NO, NOx NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Metoda chemiluminescencyjna (CLD) PN-EN 14792:2017-04","categories":["other"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) NO, NOx concentration NO (1,3 – 670) mg/m3 NOx (2,0 – 1025) mg/m3 Chemiluminescence method (CLD) PN-EN 14792:2017-04","search_zh":"自动测量系统（AMS） PN-EN 14792:2017-04","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f3825271b","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie O2 Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD)","methodology_en":"O2 concentration Range: (0,2 – 21) % Paramagnetic method (PMD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie O2 Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie O2 Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie O2 Zakres: (0,2 – 21) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) O2 concentration Range: (0,2 – 21) % Paramagnetic method (PMD) PN-EN 14789:2017-04","search_zh":"自动测量系统（AMS） PN-EN 14789:2017-04","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f3825271c","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa","methodology_en":"SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa PN-EN 14791:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie SO2 Zakres: (5,0 – 5000) mg/m3 Metoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) SO2 concentration Range: (5,0 – 5000) mg/m3 Thorin method PN-EN 14791:2017-04","search_zh":"自动测量系统（AMS） PN-EN 14791:2017-04","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a5a55f99af9f73f3825271d","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019","norm_bases":["ISO 12039:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie dwutlenku węgla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 Automatyczne Systemy Monitoringu (AMS) Stezenie dwutlenku wegla Zakres: (1,0 – 18) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) Carbon dioxide concentration Range: (1,0 – 18) % Non-dispersive infrared spectrometry method (NDIR) ISO 12039:2019","search_zh":"自动测量系统（AMS） 二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR） ISO 12039:2019","test_object_zh":"自动测量系统（AMS）","methodology_zh":"二氧化碳浓度 范围：(1,0 – 18) % 非分散红外光谱法（NDIR）"},{"_id":"6a5a55f99af9f73f3825271e","lab_id":"69ad52a3de79e566650fb71a","country":"PL","accr_number":"AB 1382","accr_body":"PCA","test_object":"Automatyczne Systemy Monitoringu (AMS)","test_object_en":"Automated Measuring Systems (AMS)","methodology":"Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa","methodology_en":"Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Automatyczne Systemy Monitoringu (AMS) Stężenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa PN-EN 14790:2017-04 Automatyczne Systemy Monitoringu (AMS) Stezenie pary wodnej (H2O) Zakres: (4,0 – 40) % obj. Metoda kondensacyjno-adsorpcyjna Zakres: (4,0 – 50) % obj. Metoda temperaturowa PN-EN 14790:2017-04","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Automated Measuring Systems (AMS) Water vapour (H2O) concentration Range: (4,0 – 40) % vol. Condensation-adsorption method Range: (4,0 – 50) % vol. Temperature method PN-EN 14790:2017-04","search_zh":"自动测量系统（AMS） PN-EN 14790:2017-04","test_object_zh":"自动测量系统（AMS）"}],"has_pdf":true}