🇵🇱 ZABRZAŃSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW PL
Water & wastewaterMicrobiology
ZABRZAŃSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1380 (Zabrze, Poland). Its accreditation scope covers 54 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water Wastewater, Water intended for human consumption, Wastewater.
At a glance
- Accreditation number: PCA AB 1380
- Methods in scope: 54
- Types of test objects: 5
- City: Zabrze, Poland
- Accreditation number
- AB 1380
- Accreditation body
- PCA
- Address
- I KANALIZACJI Sp. z o.o., ul. Wolności 215, 41-800 Zabrze, LABORATORIUM, ul. Pestalozziego 10
- City
- Zabrze, Poland
What this laboratory tests (5)
- Water — 28 methods
- Water Wastewater — 15 methods
- Water intended for human consumption — 7 methods
- Wastewater — 3 methods
- Water Water intended for human consumption — 1 method
Accreditation scope — test methods (54)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 20,0) °C | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 2 | Water Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3 | ||
| 3 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C | PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3 | PB-13 | ||
| 4 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C | PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r. | ||
| 5 | Water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 6 | Water | Total iron concentration Range: (0,010 – 2,500) mg/l Spectrophotometric method | PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008 | ||
| 7 | Water | Manganese concentration Range: (0,010 – 0,500) mg/l Spectrophotometric method | PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149 | ||
| 8 | Water | Ammonium ion concentration Range: (0,020 – 2,500) mg/l Spectrophotometric method | PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038 | ||
| 9 | Water | Apparent colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025 | ||
| 10 | Water | Electrical conductivity Range: (147 – 2500) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 11 | Water | Turbidity Range: (0,10 – 30) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 12 | Water | Total calcium and magnesium content (total hardness) Range: (5 – 700) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 13 | Water | Chloride concentration Range: (5 – 300) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 14 | Water | Nitrate concentration Range: (0,6 – 75) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 15 | Water | Calcium concentration Range: (2 – 150) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 16 | Water | Magnesium concentration (calculated) | PN-C-04554-4:1999 | ||
| 17 | Water | Permanganate index Range: (0,50 – 10,0) mg/l Titrimetric method | PN-EN ISO 8467:2001 | ||
| 18 | Water | Sulfate concentration Range: (5 – 300) mg/l Spectrophotometric method | PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051 | ||
| 19 | Water intended for human consumption | Free chlorine concentration Range: (0,10 – 0,60) mg/l Colorimetric method | PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021 | ||
| 20 | Water intended for human consumption | Total chlorine concentration Range: (0,10 – 1,00) mg/l Colorimetric method | PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021 | ||
| 21 | Water intended for human consumption | Combined chlorine concentration (calculated) | |||
| 22 | Water intended for human consumption | Total chlorine concentration Range: (0,10 – 1,00) mg/l Spectrophotometric method | PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021 | ||
| 23 | Water intended for human consumption | Combined chlorine concentration (calculated) | |||
| 24 | Water intended for human consumption | Free chlorine concentration Range: (0,10 – 0,60) mg/l Spectrophotometric method | PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021 | ||
| 25 | Water | Fluoride concentration Range: (0,10 – 1,90) mg/l Spectrophotometric method | PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029 | ||
| 26 | Water | Cyanide concentration Range: (0,010 – 0,200) mg/l Spectrophotometric method | PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027 | ||
| 27 | Water | Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 28 | Water | Escherichia coli count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 29 | Water | Coliform bacteria count Membrane filtration method | |||
| 30 | Water | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 31 | Water | Clostridium perfringens count (including spores) Membrane filtration method | PN-EN ISO 14189:2016-10 | ||
| 32 | Water | Total count of microorganisms at a temperature of 36°C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 33 | Water | Total count of microorganisms at 22°C Plate method (pour plate) | |||
| 34 | Water | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 35 | Water | Most probable number of Escherichia coli MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 36 | Water | Most probable number of coliform bacteria MPN method | |||
| 37 | Water | Most probable number of intestinal enterococci MPN method | PB-18 wydanie 4 z dnia 19.06.2020 r. | ||
| 38 | Wastewater | Chemical oxygen demand - COD-Cr Range: (30 – 5000) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 39 | Wastewater | Ammonium nitrogen concentration Range: (2,00 – 1100) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 40 | Water Wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 41 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 42 | Water Wastewater | Total suspended solids Range: (2,0 – 1100) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 43 | Water Wastewater | Nitrate nitrogen concentration Range: (0,05 – 25) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 44 | Water Wastewater | Total nitrogen (calculated) | PB-12 wydanie 7 z dnia 19.06.2020 r. | ||
| 45 | Water Wastewater | Chloride concentration Range: (5,0 – 5000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 46 | Water Wastewater | Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 47 | Water Wastewater | Nitrite nitrogen concentration Range: (0,010 – 2,50) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 48 | Water Wastewater | Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 49 | Water Wastewater | Total phosphorus concentration Range: (0,040 – 75,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7 | ||
| 50 | Water Wastewater | Electrical conductivity Range: (200 – 100 000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 51 | Water Wastewater | Ammonium nitrogen concentration Range: (0,05 – 1000) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 52 | Water Wastewater | Phenol index Range: (0,004 – 1,0) mg/l Spectrophotometric method | PN-ISO 6439:1994 | ||
| 53 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (5 – 30000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 54 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
Reference standards (45)
PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008
PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149
PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038
PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025
PB-12 wydanie 7 z dnia 19.06.2020 r.
PB-13
PB-18 wydanie 4 z dnia 19.06.2020 r.
PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027
PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051
PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021
PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029
PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021
PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021
PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021
PN-82/C-04576/08
PN-C-04554-4:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3
PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r.
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994