{"lab":{"_id":"69ad52a3de79e566650fb716","accr_number":"AB 1380","country":"PL","accr_body":"PCA","address":"I KANALIZACJI Sp. z o.o., ul. Wolności 215, 41-800 Zabrze, LABORATORIUM, ul. Pestalozziego 10","categories":["water","microbiology"],"city":"Zabrze","imported_at":"2026-03-08T10:42:43.265Z","methods_count":54,"name":"ZABRZAŃSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1380.pdf"],"scope_summary":"","search_text":"zabrzańskie przedsiębiorstwo wodociągów i kanalizacji sp. z o.o., ul. wolności 215, 41-800 zabrze, laboratorium, ul. pestalozziego 10 water microbiology other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:33.109Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:33.109Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201380,podmiot.html","parse_date":"2026-07-17T16:19:05.335Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"13","date":"10.10.2025"},"map_coord":[50.306024,18.774686],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":54,"microbiology":5},"category_scores":{"water":49.42,"microbiology":0.42},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f382526af","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 20,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 20,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 20,0) °C","reference":"PN-ISO 5667-5:2017-10 PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 20,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5,0 – 20,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 20,0) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10 PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526b0","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3 Woda Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem p. 4.4.3","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3","methodology_zh":"微生物检测用样品采集","search_zh":"水 生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem p. 4.4.3","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55f99af9f73f382526b1","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3 | PB-13","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3","PB-13"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3 | PB-13 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem p. 7.3 | PB-13","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3 | PB-13","search_zh":"水 用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem p. 7.3 | PB-13","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C"},{"_id":"6a5a55f99af9f73f382526b2","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C","reference":"PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r.","norm_bases":["PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r. Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej probki sciekow Zakres: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r.","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r.","search_zh":"污水 用于化学与物理检验的采样 手工法 自动法 所采废水样品的温度 范围：(5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PB-13 wydanie 4 z dnia 19.06.2020 r.","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工法 自动法 所采废水样品的温度 范围：(5,0 – 50,0) °C"},{"_id":"6a5a55f99af9f73f382526b3","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f382526b4","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego Zakres: (0,010 – 2,500) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,010 – 2,500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,010 – 2,500) mg/l Metoda spektrofotometryczna","reference":"PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008","norm_bases":["PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego Zakres: (0,010 – 2,500) mg/l Metoda spektrofotometryczna PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008 Woda Stezenie zelaza ogolnego Zakres: (0,010 – 2,500) mg/l Metoda spektrofotometryczna PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8008","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total iron concentration Range: (0,010 – 2,500) mg/l Spectrophotometric method PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008","search_zh":"水 PB-03 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8008","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526b5","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (0,010 – 0,500) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,010 – 0,500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,010 – 0,500) mg/l Metoda spektrofotometryczna","reference":"PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149","norm_bases":["PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (0,010 – 0,500) mg/l Metoda spektrofotometryczna PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149 Woda Stezenie manganu Zakres: (0,010 – 0,500) mg/l Metoda spektrofotometryczna PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8149","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (0,010 – 0,500) mg/l Spectrophotometric method PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149","search_zh":"水 PB-04 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8149","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526b6","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego Zakres: (0,020 – 2,500) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,020 – 2,500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,020 – 2,500) mg/l Metoda spektrofotometryczna","reference":"PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038","norm_bases":["PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego Zakres: (0,020 – 2,500) mg/l Metoda spektrofotometryczna PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038 Woda Stezenie jonu amonowego Zakres: (0,020 – 2,500) mg/l Metoda spektrofotometryczna PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8038","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium ion concentration Range: (0,020 – 2,500) mg/l Spectrophotometric method PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038","search_zh":"水 PB-05 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8038","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526b7","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa pozorna Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Apparent colour Range: (2 – 100) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa pozorna Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","reference":"PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025","norm_bases":["PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa pozorna Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025 Woda Barwa pozorna Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8025","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Apparent colour Range: (2 – 100) mg/l Pt Spectrophotometric method PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025","search_zh":"水 PB-06 wydanie 8 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8025","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526b8","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (147 – 2500) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (147 – 2500) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (147 – 2500) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (147 – 2500) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (147 – 2500) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Electrical conductivity Range: (147 – 2500) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 PN-EN 27888:1999","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526b9","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,10 – 30) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 30) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 30) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,10 – 30) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,10 – 30) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,10 – 30) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526ba","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 700) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5 – 700) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 700) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 700) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5 – 700) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (5 – 700) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526bb","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków Zakres: (5 – 300) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5 – 300) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5 – 300) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków Zakres: (5 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow Zakres: (5 – 300) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chloride concentration Range: (5 – 300) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 PN-ISO 9297:1994","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526bc","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotanów Zakres: (0,6 – 75) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,6 – 75) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,6 – 75) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotanów Zakres: (0,6 – 75) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Stezenie azotanow Zakres: (0,6 – 75) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrate concentration Range: (0,6 – 75) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 PN-82/C-04576/08","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526bd","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia Zakres: (2 – 150) mg/l Metoda miareczkowa","methodology_en":"Calcium concentration Range: (2 – 150) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wapnia Zakres: (2 – 150) mg/l Metoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia Zakres: (2 – 150) mg/l Metoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia Zakres: (2 – 150) mg/l Metoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Calcium concentration Range: (2 – 150) mg/l Titrimetric method PN-ISO 6058:1999","search_zh":"水 PN-ISO 6058:1999","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526be","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999","norm_bases":["PN-C-04554-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Woda Stezenie magnezu (z obliczen) PN-C-04554-4:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Magnesium concentration (calculated) PN-C-04554-4:1999","search_zh":"水 镁浓度（计算值） PN-C-04554-4:1999","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5a55f99af9f73f382526bf","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 10,0) mg/l Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,50 – 10,0) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 10,0) mg/l Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy Zakres: (0,50 – 10,0) mg/l Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy Zakres: (0,50 – 10,0) mg/l Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,50 – 10,0) mg/l Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526c0","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów Zakres: (5 – 300) mg/l Metoda spektrofotometryczna","methodology_en":"Sulfate concentration Range: (5 – 300) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (5 – 300) mg/l Metoda spektrofotometryczna","reference":"PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051","norm_bases":["PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów Zakres: (5 – 300) mg/l Metoda spektrofotometryczna PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051 Woda Stezenie siarczanow Zakres: (5 – 300) mg/l Metoda spektrofotometryczna PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8051","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sulfate concentration Range: (5 – 300) mg/l Spectrophotometric method PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051","search_zh":"水 PB-22 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8051","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526c1","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru wolnego  Zakres: (0,10 – 0,60) mg/l Metoda kolorymetryczna","methodology_en":"Free chlorine concentration  Range: (0,10 – 0,60) mg/l Colorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego  Zakres: (0,10 – 0,60) mg/l Metoda kolorymetryczna","reference":"PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","norm_bases":["PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego  Zakres: (0,10 – 0,60) mg/l Metoda kolorymetryczna PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021 Woda do spozycia przez ludzi Stezenie chloru wolnego  Zakres: (0,10 – 0,60) mg/l Metoda kolorymetryczna PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8021","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Free chlorine concentration  Range: (0,10 – 0,60) mg/l Colorimetric method PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","search_zh":"生活饮用水 PB-59 wydanie 2 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526c2","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru całkowitego  Zakres: (0,10 – 1,00) mg/l Metoda kolorymetryczna","methodology_en":"Total chlorine concentration  Range: (0,10 – 1,00) mg/l Colorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego  Zakres: (0,10 – 1,00) mg/l Metoda kolorymetryczna","reference":"PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","norm_bases":["PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru całkowitego  Zakres: (0,10 – 1,00) mg/l Metoda kolorymetryczna PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021 Woda do spozycia przez ludzi Stezenie chloru calkowitego  Zakres: (0,10 – 1,00) mg/l Metoda kolorymetryczna PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodyke Hach nr 8167 oraz 8021","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total chlorine concentration  Range: (0,10 – 1,00) mg/l Colorimetric method PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","search_zh":"生活饮用水 PB-60 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526c3","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru związanego  (z obliczeń)","methodology_en":"Combined chlorine concentration  (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego  (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru związanego  (z obliczeń) Woda do spozycia przez ludzi Stezenie chloru zwiazanego  (z obliczen)","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Combined chlorine concentration  (calculated)","search_zh":"生活饮用水","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526c4","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru całkowitego Zakres: (0,10 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Total chlorine concentration Range: (0,10 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego Zakres: (0,10 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","norm_bases":["PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru całkowitego Zakres: (0,10 – 1,00) mg/l Metoda spektrofotometryczna PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021 Woda do spozycia przez ludzi Stezenie chloru calkowitego Zakres: (0,10 – 1,00) mg/l Metoda spektrofotometryczna PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodyke Hach nr 8167 oraz 8021","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total chlorine concentration Range: (0,10 – 1,00) mg/l Spectrophotometric method PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","search_zh":"生活饮用水 PB-61 wydanie 2 z dnia 25.09.2024 r. w oparciu o metodykę Hach nr 8167 oraz 8021","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526c5","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru związanego (z obliczeń) Woda do spozycia przez ludzi Stezenie chloru zwiazanego (z obliczen)","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Combined chlorine concentration (calculated)","search_zh":"生活饮用水 化合氯浓度（计算值）","test_object_zh":"生活饮用水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a5a55f99af9f73f382526c6","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru wolnego Zakres: (0,10 – 0,60) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,10 – 0,60) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,10 – 0,60) mg/l Metoda spektrofotometryczna","reference":"PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","norm_bases":["PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego Zakres: (0,10 – 0,60) mg/l Metoda spektrofotometryczna PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021 Woda do spozycia przez ludzi Stezenie chloru wolnego Zakres: (0,10 – 0,60) mg/l Metoda spektrofotometryczna PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8021","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Free chlorine concentration Range: (0,10 – 0,60) mg/l Spectrophotometric method PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","search_zh":"生活饮用水 PB-25 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8021","test_object_zh":"生活饮用水"},{"_id":"6a5a55f99af9f73f382526c7","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie fluorków Zakres: (0,10 – 1,90) mg/l Metoda spektrofotometryczna","methodology_en":"Fluoride concentration Range: (0,10 – 1,90) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,10 – 1,90) mg/l Metoda spektrofotometryczna","reference":"PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029","norm_bases":["PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie fluorków Zakres: (0,10 – 1,90) mg/l Metoda spektrofotometryczna PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029 Woda Stezenie fluorkow Zakres: (0,10 – 1,90) mg/l Metoda spektrofotometryczna PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8029","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Fluoride concentration Range: (0,10 – 1,90) mg/l Spectrophotometric method PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029","search_zh":"水 PB-56 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8029","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526c8","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cyjanków Zakres: (0,010 – 0,200) mg/l Metoda spektrofotometryczna","methodology_en":"Cyanide concentration Range: (0,010 – 0,200) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie cyjanków Zakres: (0,010 – 0,200) mg/l Metoda spektrofotometryczna","reference":"PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027","norm_bases":["PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cyjanków Zakres: (0,010 – 0,200) mg/l Metoda spektrofotometryczna PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027 Woda Stezenie cyjankow Zakres: (0,010 – 0,200) mg/l Metoda spektrofotometryczna PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodyke Hach nr 8027","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Cyanide concentration Range: (0,010 – 0,200) mg/l Spectrophotometric method PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027","search_zh":"水 PB-20 wydanie 5 z dnia 19.06.2020 r. w oparciu o metodykę Hach nr 8027","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526c9","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow Zakres: (0,010 – 0,800) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Nitrite concentration Range: (0,010 – 0,800) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 PN-EN 26777:1999","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526ca","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526cb","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli Metoda filtracji membranowej Woda Liczba bakterii grupy coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Coliform bacteria count Membrane filtration method","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水 大肠菌群计数 膜过滤法","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526cc","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55f99af9f73f382526cd","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","methodology_en":"Clostridium perfringens count (including spores) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens (lacznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢） 膜过滤法"},{"_id":"6a5a55f99af9f73f382526ce","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at a temperature of 36°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w temperaturze 36°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w temperaturze 36°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total count of microorganisms at a temperature of 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水 PN-EN ISO 6222:2004","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526cf","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total count of microorganisms at 22°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22°C Metoda płytkowa (posiew wgłębny)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w temperaturze 22°C Metoda płytkowa (posiew wgłębny) Woda Ogolna liczba mikroorganizmow w temperaturze 22°C Metoda plytkowa (posiew wglebny)","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total count of microorganisms at 22°C Plate method (pour plate)","search_zh":"水","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f382526d0","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"水","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55f99af9f73f382526d1","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL","methodology_en":"Most probable number of Escherichia coli MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL PN-EN ISO 9308-2:2014-06 Woda Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水 大肠埃希氏菌最可能数 MPN 法 PN-EN ISO 9308-2:2014-06","test_object_zh":"水","methodology_zh":"大肠埃希氏菌最可能数 MPN 法"},{"_id":"6a5a55f99af9f73f382526d2","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","methodology_en":"Most probable number of coliform bacteria MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL Woda Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","categories":["water","microbiology"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of coliform bacteria MPN method","search_zh":"水 大肠菌群最可能数 MPN 法","test_object_zh":"水","methodology_zh":"大肠菌群最可能数 MPN 法"},{"_id":"6a5a55f99af9f73f382526d3","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych Metoda NPL","methodology_en":"Most probable number of intestinal enterococci MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych Metoda NPL","reference":"PB-18 wydanie 4 z dnia 19.06.2020 r.","norm_bases":["PB-18 wydanie 4 z dnia 19.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków kałowych Metoda NPL PB-18 wydanie 4 z dnia 19.06.2020 r. Woda Najbardziej prawdopodobna liczba enterokokow kalowych Metoda NPL PB-18 wydanie 4 z dnia 19.06.2020 r.","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of intestinal enterococci MPN method PB-18 wydanie 4 z dnia 19.06.2020 r.","search_zh":"水 粪肠球菌最可能数 MPN 法 PB-18 wydanie 4 z dnia 19.06.2020 r.","test_object_zh":"水","methodology_zh":"粪肠球菌最可能数 MPN 法"},{"_id":"6a5a55f99af9f73f382526d4","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 5000) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD-Cr Range: (30 – 5000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 5000) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 5000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 5000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 5000) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"污水 PN-ISO 6060:2006","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382526d5","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (2,00 – 1100) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (2,00 – 1100) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (2,00 – 1100) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (2,00 – 1100) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego Zakres: (2,00 – 1100) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (2,00 – 1100) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382526d6","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55f99af9f73f382526d7","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 2000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 2000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(3 – 2000) mg/l O2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3 – 2000) mg/l O2 电化学法"},{"_id":"6a5a55f99af9f73f382526d8","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 1100) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 – 1100) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 1100) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (2,0 – 1100) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (2,0 – 1100) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: (2,0 – 1100) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526d9","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,05 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,05 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,05 – 25) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotanowego Zakres: (0,05 – 25) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Scieki Stezenie azotu azotanowego Zakres: (0,05 – 25) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate nitrogen concentration Range: (0,05 – 25) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 废水 PN-82/C-04576/08","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526da","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Azot ogólny (z obliczeń)","methodology_en":"Total nitrogen (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Azot ogólny (z obliczeń)","reference":"PB-12 wydanie 7 z dnia 19.06.2020 r.","norm_bases":["PB-12 wydanie 7 z dnia 19.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Azot ogólny (z obliczeń) PB-12 wydanie 7 z dnia 19.06.2020 r. Woda Scieki Azot ogolny (z obliczen) PB-12 wydanie 7 z dnia 19.06.2020 r.","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen (calculated) PB-12 wydanie 7 z dnia 19.06.2020 r.","search_zh":"水 废水 总氮（由计算得出） PB-12 wydanie 7 z dnia 19.06.2020 r.","test_object_zh":"水 废水","methodology_zh":"总氮（由计算得出）"},{"_id":"6a5a55f99af9f73f382526db","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 5000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 5000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 5000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chlorków Zakres: (5,0 – 5000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Scieki Stezenie chlorkow Zakres: (5,0 – 5000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chloride concentration Range: (5,0 – 5000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 废水 PN-ISO 9297:1994","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526dc","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda Scieki Stezenie siarczanow Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水 废水 硫酸盐浓度 范围：(10 – 1000) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"水 废水","methodology_zh":"硫酸盐浓度 范围：(10 – 1000) mg/l 重量法"},{"_id":"6a5a55f99af9f73f382526dd","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,010 – 2,50) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,010 – 2,50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,010 – 2,50) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu azotynowego Zakres: (0,010 – 2,50) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotu azotynowego Zakres: (0,010 – 2,50) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite nitrogen concentration Range: (0,010 – 2,50) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526de","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水 废水 凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法 PN-EN 25663:2001","test_object_zh":"水 废水","methodology_zh":"凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法"},{"_id":"6a5a55f99af9f73f382526df","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,040 – 75,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,040 – 75,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,040 – 75,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,040 – 75,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,040 – 75,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,040 – 75,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7","search_zh":"水 废水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 p.7","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526e0","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (200 – 100 000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (200 – 100 000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (200 – 100 000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Przewodność elektryczna właściwa Zakres: (200 – 100 000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (200 – 100 000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Electrical conductivity Range: (200 – 100 000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 废水 PN-EN 27888:1999","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526e1","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,05 – 1000) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,05 – 1000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,05 – 1000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,05 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,05 – 1000) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,05 – 1000) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526e2","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Indeks fenolowy Zakres: (0,004 – 1,0) mg/l Metoda spektrofotometryczna","methodology_en":"Phenol index Range: (0,004 – 1,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks fenolowy Zakres: (0,004 – 1,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Indeks fenolowy Zakres: (0,004 – 1,0) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994 Woda Scieki Indeks fenolowy Zakres: (0,004 – 1,0) mg/l Metoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Phenol index Range: (0,004 – 1,0) mg/l Spectrophotometric method PN-ISO 6439:1994","search_zh":"水 废水 PN-ISO 6439:1994","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526e3","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 30000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (5 – 30000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 30000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 30000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5 – 30000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (5 – 30000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a55f99af9f73f382526e4","lab_id":"69ad52a3de79e566650fb716","country":"PL","accr_number":"AB 1380","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,50 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,50 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(0,50 – 6,0) mg/l O 2 电化学法 PN-EN 1899-2:2002","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(0,50 – 6,0) mg/l O 2 电化学法"}],"has_pdf":true}