🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1379 (Brzeg, Poland). Its accreditation scope covers 28 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Water intended for human consumption, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1379
- Methods in scope: 28
- Types of test objects: 5
- Techniques used: 11
- City: Brzeg, Poland
- Accreditation number
- AB 1379
- Accreditation body
- PCA
- Address
- W BRZEGU Sp. z o.o., ul. Wolności 15, 49-300 Brzeg, LABORATORIUM, Gierszowice
- City
- Brzeg, Poland
What this laboratory tests (5)
- Water, Water intended for human consumption — 10 methods
- Wastewater, Water, Water intended for human consumption — 7 methods
- Wastewater — 6 methods
- Water intended for human consumption — 4 methods
- Water — 1 method
Analytical techniques used (11)
- Spectrophotometric method — 8 methods
- Membrane filtration method — 5 methods
- Gravimetric method — 3 methods
- Plate method (pour plate) — 2 methods
- Titrimetric method — 2 methods
- Colorimetric method — 1 method
- Conductometric method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Optical method — 1 method
- Potentiometric method — 1 method
Laboratory locations
- Laboratorium; Gierszowice, 49-332 Olszanka —
Accreditation scope — test methods (28)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory; Gierszowice, 49-332 Olszanka | |||||
| 1 | Wastewater, Water, Water intended for human consumption | Ammonium nitrogen concentration Range (0,04 – 200) mg/l Ammonium ion concentration Range (0,05 – 256) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 2 | Wastewater, Water, Water intended for human consumption | Nitrate nitrogen concentration Range (0,09 – 18,0) mg/l Nitrate concentration Range (0,4 – 79,6) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 3 | Wastewater, Water, Water intended for human consumption | Chemical oxygen demand COD Range (20,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 4 | Wastewater, Water, Water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 5 | Wastewater, Water, Water intended for human consumption | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 | |
| 6 | Wastewater, Water, Water intended for human consumption | Chloride concentration Range (5,00 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 7 | Wastewater, Water, Water intended for human consumption | Sulfate concentration Range (10 – 250) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 8 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 9 | Wastewater | Total nitrogen concentration Range (5,00 – 150) mg/l |
Spectrophotometric method | PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238 | |
| 10 | Wastewater | Dissolved solids Range (400 – 8000) mg/l |
Gravimetric method | PN-EN 15216:2010 | |
| 11 | Wastewater | Total iron Range (0,05 – 5,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 | |
| 12 | Wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 13 | Wastewater | Total phosphorus concentration Range (0,04 – 30) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 | |
| 14 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 15 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 16 | Water intended for human consumption | Free chlorine Range (0,05 – 2,0) mg/l |
Colorimetric method | PN-EN ISO 7393-2:2018-04 | |
| 17 | Water, Water intended for human consumption | Manganese concentration Range (0,03 – 3,00) mg/l |
Spectrophotometric method | PN-92/C-04590.03 | |
| 18 | Water, Water intended for human consumption | Turbidity Range (0,50 – 50) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 19 | Water, Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (60 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 20 | Water, Water intended for human consumption | Electrical conductivity Range (100 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 21 | Water, Water intended for human consumption | Total iron concentration Range (0,01 – 5,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 | |
| 22 | Water, Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 23 | Water, Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 24 | Water, Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 25 | Water, Water intended for human consumption | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 26 | Water, Water intended for human consumption | Clostridium perfringens count including spores | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 27 | Water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 28 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
Reference standards (30)
PB-08 wyd.2 z 01.06.2017 r.
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 15216:2010
PN-EN 27888:1999
PN-EN 872:2007
PN-EN 872:2007/Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 8
PN-EN ISO 6878:2006/Ap1:2010
PN-EN ISO 6878:2006/Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu Hach Lange LCK 338, LCK 238