🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL

PCA AB 1379 • Brzeg, Poland • 28 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1379 (Brzeg, Poland). Its accreditation scope covers 28 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Water intended for human consumption, Wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1379
  • Methods in scope: 28
  • Types of test objects: 5
  • Techniques used: 11
  • City: Brzeg, Poland
Accreditation number
AB 1379
Accreditation body
PCA
Address
W BRZEGU Sp. z o.o., ul. Wolności 15, 49-300 Brzeg, LABORATORIUM, Gierszowice
City
Brzeg, Poland

What this laboratory tests (5)

Analytical techniques used (11)

Laboratory locations

Accreditation scope — test methods (28)

No. Test object Methodology / Parameters Technique Reference document
Laboratory; Gierszowice, 49-332 Olszanka
1 Wastewater, Water, Water intended for human consumption Ammonium nitrogen concentration
Range (0,04 – 200) mg/l Ammonium ion concentration Range (0,05 – 256) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
2 Wastewater, Water, Water intended for human consumption Nitrate nitrogen concentration
Range (0,09 – 18,0) mg/l Nitrate concentration Range (0,4 – 79,6) mg/l
Spectrophotometric method PN-82/C-04576.08
3 Wastewater, Water, Water intended for human consumption Chemical oxygen demand
COD Range (20,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
4 Wastewater, Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
5 Wastewater, Water, Water intended for human consumption Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007
6 Wastewater, Water, Water intended for human consumption Chloride concentration
Range (5,00 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
7 Wastewater, Water, Water intended for human consumption Sulfate concentration
Range (10 – 250) mg/l
Gravimetric method PN-ISO 9280:2002
8 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
9 Wastewater Total nitrogen concentration
Range (5,00 – 150) mg/l
Spectrophotometric method PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238
10 Wastewater Dissolved solids
Range (400 – 8000) mg/l
Gravimetric method PN-EN 15216:2010
11 Wastewater Total iron
Range (0,05 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06
12 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
13 Wastewater Total phosphorus concentration
Range (0,04 – 30) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010
14 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
15 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
16 Water intended for human consumption Free chlorine
Range (0,05 – 2,0) mg/l
Colorimetric method PN-EN ISO 7393-2:2018-04
17 Water, Water intended for human consumption Manganese concentration
Range (0,03 – 3,00) mg/l
Spectrophotometric method PN-92/C-04590.03
18 Water, Water intended for human consumption Turbidity
Range (0,50 – 50) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
19 Water, Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (60 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
20 Water, Water intended for human consumption Electrical conductivity
Range (100 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
21 Water, Water intended for human consumption Total iron concentration
Range (0,01 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06
22 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
23 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
24 Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
25 Water, Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
26 Water, Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
27 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
28 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004

Reference standards (30)

PB-08 wyd.2 z 01.06.2017 r.
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 15216:2010
PN-EN 27888:1999
PN-EN 872:2007
PN-EN 872:2007/Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 8
PN-EN ISO 6878:2006/Ap1:2010
PN-EN ISO 6878:2006/Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu Hach Lange LCK 338, LCK 238