{"lab":{"_id":"69ad52a3de79e566650fb714","accr_number":"AB 1379","country":"PL","accr_body":"PCA","address":"W BRZEGU Sp. z o.o., ul. Wolności 15, 49-300 Brzeg, LABORATORIUM, Gierszowice","categories":["water","microbiology"],"city":"Brzeg","imported_at":"2026-03-08T10:42:43.265Z","methods_count":28,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1379.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji w brzegu sp. z o.o., ul. wolności 15, 49-300 brzeg, laboratorium, gierszowice water other microbiology pharma electronics automotive","status":"active","updated_at":"2026-03-08T14:50:32.970Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:00:14.499Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201379,podmiot.html","parse_date":"2026-08-13T08:00:14.499Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"}],"issue":{"no":"14","date":"15.07.2026"},"map_coord":[50.858819,17.456824],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium; Gierszowice, 49-332 Olszanka","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/41feb086d9d9003273f23368fd63fafc/AB%201379.pdf","has_en":true,"category_counts":{"water":28,"microbiology":3},"category_scores":{"water":25.29,"microbiology":0.29},"has_zh":true,"lab_locations_zh":[{"name":"实验室；Gierszowice, 49-332 Olszanka","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d798e0636ba417e41ab13","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 – 200) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,05 – 256) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 200) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 256) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres:\nZakres (0,04 – 200) mg/l\nStężenie jonu amonowego\nZakres (0,05 – 256) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, Woda, Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres:\nZakres (0,04 – 200) mg/l\nStezenie jonu amonowego\nZakres (0,05 – 256) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 200) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,05 – 256) mg/l"}],"search_en":"Wastewater, Water, Water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range Ammonium ion concentration Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 200) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,05 – 256) mg/l"}],"search_zh":"废水、水、生活饮用水 氨氮浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 铵离子浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab14","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,09 – 18,0) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,4 – 79,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,09 – 18,0) mg/l\nStężenie azotanów\nZakres (0,4 – 79,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie azotu azotanowego\nZakres:\nZakres (0,09 – 18,0) mg/l\nStężenie azotanów\nZakres (0,4 – 79,6) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki, Woda, Woda do spozycia przez ludzi Stezenie azotu azotanowego\nZakres:\nZakres (0,09 – 18,0) mg/l\nStezenie azotanow\nZakres (0,4 – 79,6) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,09 – 18,0) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,4 – 79,6) mg/l"}],"search_en":"Wastewater, Water, Water intended for human consumption Nitrate nitrogen concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range Nitrate concentration Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,09 – 18,0) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,4 – 79,6) mg/l"}],"search_zh":"废水、水、生活饮用水 硝态氮浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 硝酸盐浓度 范围 PN-82/C-04576.08","technique_zh":"分光光度法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab15","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(20,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda, Woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (20,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD"},{"name":"Range","range":"(20,0 – 10000) mg/l O2"}],"search_en":"Wastewater, Water, Water intended for human consumption Chemical oxygen demand Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka COD Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water, Water intended for human consumption","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(20,0 – 10000) mg/l O2"}],"search_zh":"废水、水、生活饮用水 化学需氧量（COD） 分光光度法 实验室；Gierszowice, 49-332 Olszanka 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab16","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki, Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater, Water, Water intended for human consumption pH Potentiometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"废水、水、生活饮用水 pH 值 电位法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab17","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","norm_bases":["PN-EN 872:2007","PN-EN 872:2007/Ap1:2007"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007 Scieki, Woda, Woda do spozycia przez ludzi Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Wastewater, Water, Water intended for human consumption Total suspended solids (TSS) Gravimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"废水、水、生活饮用水 总悬浮物 重量法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN 872:2007 | PN-EN 872:2007/Ap1:2007","technique_zh":"重量法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab18","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki, Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 – 400) mg/l"}],"search_en":"Wastewater, Water, Water intended for human consumption Chloride concentration Titrimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 400) mg/l"}],"search_zh":"废水、水、生活饮用水 氯化物浓度 滴定法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-ISO 9297:1994","technique_zh":"滴定法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab19","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 250) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 250) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 250) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki, Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 250) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 250) mg/l"}],"search_en":"Wastewater, Water, Water intended for human consumption Sulfate concentration Gravimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 250) mg/l"}],"search_zh":"废水、水、生活饮用水 硫酸盐浓度 重量法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-ISO 9280:2002","technique_zh":"重量法","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","test_object_zh":"废水、水、生活饮用水"},{"_id":"6a7d798e0636ba417e41ab1a","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory; Gierszowice, 49-332 Olszanka PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室；Gierszowice, 49-332 Olszanka PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab1b","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(5,00 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (5,00 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238","norm_bases":["PB-08 wyd.2 z 01.06.2017 r.","na podstawie testu Hach Lange LCK 338, LCK 238"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (5,00 – 150) mg/l\nMetoda spektrofotometryczna PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238 Scieki Stezenie azotu ogolnego\nZakres (5,00 – 150) mg/l\nMetoda spektrofotometryczna PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,00 – 150) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,00 – 150) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 PB-08 wyd.2 z 01.06.2017 r. | na podstawie testu Hach Lange LCK 338, LCK 238","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab1c","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(400 – 8000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (400 – 8000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2010","norm_bases":["PN-EN 15216:2010"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje rozpuszczone\nZakres (400 – 8000) mg/l\nMetoda wagowa PN-EN 15216:2010 Scieki Substancje rozpuszczone\nZakres (400 – 8000) mg/l\nMetoda wagowa PN-EN 15216:2010","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(400 – 8000) mg/l"}],"search_en":"Wastewater Dissolved solids Gravimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN 15216:2010","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(400 – 8000) mg/l"}],"search_zh":"污水 溶解性固体 重量法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN 15216:2010","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","methodology_zh":"溶解性固体"},{"_id":"6a7d798e0636ba417e41ab1d","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Żelazo ogólne","parameters":[{"name":"Zakres","range":"(0,05 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Żelazo ogólne\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Żelazo ogólne\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 Scieki Zelazo ogolne\nZakres (0,05 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total iron","parameters_en":[{"name":"Range","range":"(0,05 – 5,0) mg/l"}],"search_en":"Wastewater Total iron Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,05 – 5,0) mg/l"}],"search_zh":"污水 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab1e","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Laboratory; Gierszowice, 49-332 Olszanka BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 光学法 实验室；Gierszowice, 49-332 Olszanka BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab1f","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,04 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 8","PN-EN ISO 6878:2006/Ap1:2010","PN-EN ISO 6878:2006/Ap2:2010"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,04 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,04 – 30) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 30) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN ISO 6878:2006 p. 8 | PN-EN ISO 6878:2006/Ap1:2010 | PN-EN ISO 6878:2006/Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab20","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory; Gierszowice, 49-332 Olszanka PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室；Gierszowice, 49-332 Olszanka PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab21","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab22","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Chlor wolny","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04 Woda do spozycia przez ludzi Chlor wolny\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Free chlorine","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water intended for human consumption Free chlorine Colorimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN ISO 7393-2:2018-04","technique_en":"Colorimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"生活饮用水 游离氯 比色法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"比色法","test_object_zh":"生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","methodology_zh":"游离氯"},{"_id":"6a7d798e0636ba417e41ab23","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,03 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,03 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,03 – 3,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,03 – 3,00) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,03 – 3,00) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-92/C-04590.03","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 3,00) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab24","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,50 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,50 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,50 – 50) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,50 – 50) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab25","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(60 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (60 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(60 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(60 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab26","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab27","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,01 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,01 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,01 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,01 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,01 – 5,0) mg/l"}],"search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Laboratory; Gierszowice, 49-332 Olszanka Range PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 实验室；Gierszowice, 49-332 Olszanka 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab28","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab29","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab2a","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total viable count at 22°C","search_en":"Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab2b","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Total viable count at 36°C","search_en":"Water, Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"36°C 微生物总数","search_zh":"水、生活饮用水 36°C 微生物总数 平板法（倾注培养） 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab2c","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Clostridium perfringens count including spores","search_en":"Water, Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a7d798e0636ba417e41ab2d","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka"},{"_id":"6a7d798e0636ba417e41ab2e","lab_id":"69ad52a3de79e566650fb714","country":"PL","accr_number":"AB 1379","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium; Gierszowice, 49-332 Olszanka","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory; Gierszowice, 49-332 Olszanka","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory; Gierszowice, 49-332 Olszanka PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 肠道肠球菌数 膜过滤法 实验室；Gierszowice, 49-332 Olszanka PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"实验室；Gierszowice, 49-332 Olszanka","methodology_zh":"肠道肠球菌数"}],"has_pdf":true}