🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1372 • Chrzanów Duży, Poland • 49 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1372 (Chrzanów Duży, Poland). Its accreditation scope covers 49 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, wastewater, Water (including swimming pool water), water intended for human con…, Water, water intended for human consumption, Water (including swimming pool water), water intended for human con….

At a glance

  • Accreditation number: PCA AB 1372
  • Methods in scope: 49
  • Types of test objects: 10
  • City: Chrzanów Duży, Poland
Accreditation number
AB 1372
Accreditation body
PCA
Address
ul. Cegielniana 4, 05-825 Grodzisk Mazowiecki, LABORATORIUM, Ekologiczna 2, 05-825 Chrzanów Duży
City
Chrzanów Duży, Poland

What this laboratory tests (10)

Accreditation scope — test methods (49)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (0,0 – 50,0) ºC + PN-ISO 5667-10:2021-11 PN-77/C-04584
2 Swimming pool water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 50,0) ºC + RB-01.07 wyd. II z dn. 27.06.2016 r. PN-77/C-04584
3 Water, water intended for human consumption, wastewater Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
4 Water, water intended for human consumption, wastewater Ammonium ion concentration Range: (0,010 – 250) mg/l NH + 4 (0,010 – 200) mg/l N-NH + 4 Spectrophotometric method RB-07.13 wyd. IV z dnia 01.03.2018 r. na podstawie testu Nanocolor 91805
5 Water, water intended for human consumption, wastewater Nitrite concentration Range: (0,010 – 3,0) mg/l NO - 2 (0,003 – 0,90) mg/l N-NO - 2 Spectrophotometric method PN-EN 26777:1999
6 Water, water intended for human consumption, wastewater Total cyanide concentration Range: (0,005 – 1,0) mg/l Spectrophotometric method RB-07.08 wyd. III z dn. 30.09.2014 r. na podstawie testu Merck 1.09701
7 Water (including swimming pool water), water intended for human consumption, wastewater pH + Range: 2,0 – 10,0 Potentiometric method EN ISO 10523:2012
8 Water (including swimming pool water), water intended for human consumption, wastewater Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl Range: (220 – 800) mV Potentiometric method RB-07.26 wyd. I z dn. 20.01.2017 r.
9 Water (including swimming pool water), water intended for human consumption, wastewater Nitrate concentration Range: (1 – 132) mg/l NO - 3 (0,23 – 30) mg/l N-NO - 3 Spectrophotometric method PN-82/C-04576/08
10 Water (including swimming pool water), water intended for human consumption, wastewater Total iron concentration Range: (0,020 – 10,0) mg/l Spectrophotometric method RB-07.23 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8008
11 Water (including swimming pool water), water intended for human consumption, wastewater Aluminium concentration Range: (20 – 1250) µg/l Spectrophotometric method RB-07.22 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8326
12 Water (including swimming pool water), water intended for human consumption, wastewater Electrical conductivity Range: (5 – 15 000) µS/cm Conductometric method PN-EN 27888:1999
13 Water (including swimming pool water), water intended for human consumption, wastewater Manganese concentration Range: (20 – 1000) µg/l Spectrophotometric method RB-07.24 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8149
14 Water (including swimming pool water), water intended for human consumption, wastewater Colour Range: (2 – 80) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012
15 Water, wastewater Total suspended solids Range (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
16 Water, wastewater Biochemical oxygen demand - BOD 5 Range: (6 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
17 Water, wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Optical method
18 Water, wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
19 Water, wastewater Sulphate concentration Range: (40,0 – 900) mg/l Turbidimetric method RB-07.01 wyd. III z dn. 02.05.2016 r. na podstawie testu Hach Lange LCK 153; LCK 353
20 Water, wastewater Total nitrogen concentration Range: (0,50 – 440) mg/l Spectrophotometric method RB-07.32 wyd. II z dnia 08.06.2021 r. na podstawie testu Nanocolor 985 083 i 985 088
21 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576-14
22 Water, wastewater Total Kjeldahl nitrogen concentration Range: (3,0 – 300) mg/l Titrimetric method PN-EN 25663:2001
23 Water, wastewater Total Kjeldahl nitrogen concentration Range: (1,0 – 300) mg/l Spectrophotometric method RB-07.34 wyd. I z dnia 01.08.2019 na podstawie testu Nanocolor 985 067
24 Water, wastewater Ammonium nitrogen concentration Range: (0,50 – 300) mg/l Titrimetric method PN-ISO 5664:2002
25 Water, wastewater Total phosphorus concentration Range: (0,05 – 80,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 + Ap2:2010
26 Water, wastewater Chemical oxygen demand - COD-Cr Range: (15,0 – 50 000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
27 Water, wastewater Anionic surfactant concentration (anionic detergents) Range: (0,05 – 10,0) mg/l Spectrophotometric method RB-07.09 wyd. III z dn. 09.03.2015 r. na podstawie testu Hach Lange LCK332
28 Water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 50,0) ºC + PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 | PN-77/C-04584
29 Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,0 – 70,0) ºC + PN-ISO 5667-5:2017-10 PN-77/C-04584
30 Water, water intended for human consumption Total hardness Range: (5 – 500) mg/l CaCO 3 (0,28 – 28) dH Titrimetric method PN-ISO 6059:1999
31 Water, water intended for human consumption Calcium concentration Range: (2 – 60) mg/l Titrimetric method PN-ISO 6058:1999
32 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A
33 Water (including swimming pool water), water intended for human consumption Turbidity Range: (0,10 – 200) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
34 Water (including swimming pool water), water intended for human consumption Free chlorine concentration + Range: (0,03 – 2,00) mg/l Colorimetric method RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021
35 Water (including swimming pool water), water intended for human consumption Total chlorine concentration + Range: (0,03 – 2,00) mg/l Colorimetric method RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8167
36 Water (including swimming pool water), water intended for human consumption Combined chlorine concentration (calculated) RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021 i 8167
37 Water (including swimming pool water), water intended for human consumption Permanganate index Range: (0,50 – 30) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
38 Water, water intended for human consumption Sampling for microbiological testing Temperature of the water sample taken Range: (0,0 – 70,0) ºC + PN-EN ISO 19458:2007 PN-77/C-04584
39 Water, water intended for human consumption Count of microorganisms at 22oC Plate method (pour plate) PN-EN ISO 6222:2004
40 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
41 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
42 Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
43 Water, water intended for human consumption Most probable number of intestinal enterococci MPN method RB-07.33 wyd. I z dnia 01.03.2018 r. Na podstawie testu Idexx Enterolert - E
44 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Matrix A procedure 5 (BCYE medium) procedure 7 (GVPC medium) Matrix B procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
45 Water (including swimming pool water), water intended for human consumption Count of microorganisms at 36oC Range: from 1 CFU/1 ml Plate method (pour plate) PN-EN ISO 6222:2004
46 Water (including swimming pool water), water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
47 Water (including swimming pool water), water intended for human consumption Most probable number of Escherichia coli bacteria MPN method PN-EN ISO 9308-2:2014-06
48 Water (including swimming pool water), water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
49 Water (including swimming pool water) Count of coagulase- positive staphylococci Range: from 1 CFU/100ml Membrane filtration method PN-Z 11001-3:2000 zał. A

Reference standards (46)

EN ISO 10523:2012
PN-73/C-04576-14
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-4:1999 zał. A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 PN-77/C-04584
PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
PN-Z 11001-3:2000 zał. A
RB-01.07 wyd. II z dn. 27.06.2016 r. PN-77/C-04584
RB-07.01 wyd. III z dn. 02.05.2016 r. na podstawie testu Hach Lange LCK 153; LCK 353
RB-07.08 wyd. III z dn. 30.09.2014 r. na podstawie testu Merck 1.09701
RB-07.09 wyd. III z dn. 09.03.2015 r. na podstawie testu Hach Lange LCK332
RB-07.13 wyd. IV z dnia 01.03.2018 r. na podstawie testu Nanocolor 91805
RB-07.22 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8326
RB-07.23 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8008
RB-07.24 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8149
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021 i 8167
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8167
RB-07.26 wyd. I z dn. 20.01.2017 r.
RB-07.32 wyd. II z dnia 08.06.2021 r. na podstawie testu Nanocolor 985 083 i 985 088
RB-07.33 wyd. I z dnia 01.03.2018 r. Na podstawie testu Idexx Enterolert - E
RB-07.34 wyd. I z dnia 01.08.2019 na podstawie testu Nanocolor 985 067