🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1372 (Chrzanów Duży, Poland). Its accreditation scope covers 49 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, wastewater, Water (including swimming pool water), water intended for human con…, Water, water intended for human consumption, Water (including swimming pool water), water intended for human con….
At a glance
- Accreditation number: PCA AB 1372
- Methods in scope: 49
- Types of test objects: 10
- City: Chrzanów Duży, Poland
- Accreditation number
- AB 1372
- Accreditation body
- PCA
- Address
- ul. Cegielniana 4, 05-825 Grodzisk Mazowiecki, LABORATORIUM, Ekologiczna 2, 05-825 Chrzanów Duży
- City
- Chrzanów Duży, Poland
What this laboratory tests (10)
- Water, wastewater — 13 methods
- Water (including swimming pool water), water intended for human consumption — 10 methods
- Water, water intended for human consumption — 9 methods
- Water (including swimming pool water), water intended for human consumption, wastewater — 8 methods
- Water, water intended for human consumption, wastewater — 4 methods
- Swimming pool water — 1 method
- Wastewater — 1 method
- Water — 1 method
- Water (including swimming pool water) — 1 method
- Water intended for human consumption — 1 method
Accreditation scope — test methods (49)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (0,0 – 50,0) ºC + | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 2 | Swimming pool water | Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 50,0) ºC + | RB-01.07 wyd. II z dn. 27.06.2016 r. PN-77/C-04584 | ||
| 3 | Water, water intended for human consumption, wastewater | Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 4 | Water, water intended for human consumption, wastewater | Ammonium ion concentration Range: (0,010 – 250) mg/l NH + 4 (0,010 – 200) mg/l N-NH + 4 Spectrophotometric method | RB-07.13 wyd. IV z dnia 01.03.2018 r. na podstawie testu Nanocolor 91805 | ||
| 5 | Water, water intended for human consumption, wastewater | Nitrite concentration Range: (0,010 – 3,0) mg/l NO - 2 (0,003 – 0,90) mg/l N-NO - 2 Spectrophotometric method | PN-EN 26777:1999 | ||
| 6 | Water, water intended for human consumption, wastewater | Total cyanide concentration Range: (0,005 – 1,0) mg/l Spectrophotometric method | RB-07.08 wyd. III z dn. 30.09.2014 r. na podstawie testu Merck 1.09701 | ||
| 7 | Water (including swimming pool water), water intended for human consumption, wastewater | pH + Range: 2,0 – 10,0 Potentiometric method | EN ISO 10523:2012 | ||
| 8 | Water (including swimming pool water), water intended for human consumption, wastewater | Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl Range: (220 – 800) mV Potentiometric method | RB-07.26 wyd. I z dn. 20.01.2017 r. | ||
| 9 | Water (including swimming pool water), water intended for human consumption, wastewater | Nitrate concentration Range: (1 – 132) mg/l NO - 3 (0,23 – 30) mg/l N-NO - 3 Spectrophotometric method | PN-82/C-04576/08 | ||
| 10 | Water (including swimming pool water), water intended for human consumption, wastewater | Total iron concentration Range: (0,020 – 10,0) mg/l Spectrophotometric method | RB-07.23 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8008 | ||
| 11 | Water (including swimming pool water), water intended for human consumption, wastewater | Aluminium concentration Range: (20 – 1250) µg/l Spectrophotometric method | RB-07.22 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8326 | ||
| 12 | Water (including swimming pool water), water intended for human consumption, wastewater | Electrical conductivity Range: (5 – 15 000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 13 | Water (including swimming pool water), water intended for human consumption, wastewater | Manganese concentration Range: (20 – 1000) µg/l Spectrophotometric method | RB-07.24 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8149 | ||
| 14 | Water (including swimming pool water), water intended for human consumption, wastewater | Colour Range: (2 – 80) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 | ||
| 15 | Water, wastewater | Total suspended solids Range (2,0 – 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 16 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (6 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 17 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Optical method | |||
| 18 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 19 | Water, wastewater | Sulphate concentration Range: (40,0 – 900) mg/l Turbidimetric method | RB-07.01 wyd. III z dn. 02.05.2016 r. na podstawie testu Hach Lange LCK 153; LCK 353 | ||
| 20 | Water, wastewater | Total nitrogen concentration Range: (0,50 – 440) mg/l Spectrophotometric method | RB-07.32 wyd. II z dnia 08.06.2021 r. na podstawie testu Nanocolor 985 083 i 985 088 | ||
| 21 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576-14 | ||
| 22 | Water, wastewater | Total Kjeldahl nitrogen concentration Range: (3,0 – 300) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 23 | Water, wastewater | Total Kjeldahl nitrogen concentration Range: (1,0 – 300) mg/l Spectrophotometric method | RB-07.34 wyd. I z dnia 01.08.2019 na podstawie testu Nanocolor 985 067 | ||
| 24 | Water, wastewater | Ammonium nitrogen concentration Range: (0,50 – 300) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 25 | Water, wastewater | Total phosphorus concentration Range: (0,05 – 80,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010 + Ap2:2010 | ||
| 26 | Water, wastewater | Chemical oxygen demand - COD-Cr Range: (15,0 – 50 000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 27 | Water, wastewater | Anionic surfactant concentration (anionic detergents) Range: (0,05 – 10,0) mg/l Spectrophotometric method | RB-07.09 wyd. III z dn. 09.03.2015 r. na podstawie testu Hach Lange LCK332 | ||
| 28 | Water | Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 50,0) ºC + | PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5 | PN-77/C-04584 | ||
| 29 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,0 – 70,0) ºC + | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 30 | Water, water intended for human consumption | Total hardness Range: (5 – 500) mg/l CaCO 3 (0,28 – 28) dH Titrimetric method | PN-ISO 6059:1999 | ||
| 31 | Water, water intended for human consumption | Calcium concentration Range: (2 – 60) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 32 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 zał. A | ||
| 33 | Water (including swimming pool water), water intended for human consumption | Turbidity Range: (0,10 – 200) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 34 | Water (including swimming pool water), water intended for human consumption | Free chlorine concentration + Range: (0,03 – 2,00) mg/l Colorimetric method | RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021 | ||
| 35 | Water (including swimming pool water), water intended for human consumption | Total chlorine concentration + Range: (0,03 – 2,00) mg/l Colorimetric method | RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8167 | ||
| 36 | Water (including swimming pool water), water intended for human consumption | Combined chlorine concentration (calculated) | RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021 i 8167 | ||
| 37 | Water (including swimming pool water), water intended for human consumption | Permanganate index Range: (0,50 – 30) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 38 | Water, water intended for human consumption | Sampling for microbiological testing Temperature of the water sample taken Range: (0,0 – 70,0) ºC + | PN-EN ISO 19458:2007 PN-77/C-04584 | ||
| 39 | Water, water intended for human consumption | Count of microorganisms at 22oC Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 40 | Water, water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 41 | Water, water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 42 | Water, water intended for human consumption | Most probable number of coliform bacteria MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 43 | Water, water intended for human consumption | Most probable number of intestinal enterococci MPN method | RB-07.33 wyd. I z dnia 01.03.2018 r. Na podstawie testu Idexx Enterolert - E | ||
| 44 | Water (including swimming pool water), water intended for human consumption | Count of bacteria of the genus Legionella Matrix A procedure 5 (BCYE medium) procedure 7 (GVPC medium) Matrix B procedure 7 (GVPC medium) Membrane filtration method | PN-EN ISO 11731:2017-08 + Ap1:2019-12 | ||
| 45 | Water (including swimming pool water), water intended for human consumption | Count of microorganisms at 36oC Range: from 1 CFU/1 ml Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 46 | Water (including swimming pool water), water intended for human consumption | Escherichia coli count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 47 | Water (including swimming pool water), water intended for human consumption | Most probable number of Escherichia coli bacteria MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 48 | Water (including swimming pool water), water intended for human consumption | Pseudomonas aeruginosa count Membrane filtration method | PN-EN ISO 16266:2009 | ||
| 49 | Water (including swimming pool water) | Count of coagulase- positive staphylococci Range: from 1 CFU/100ml Membrane filtration method | PN-Z 11001-3:2000 zał. A | ||
Reference standards (46)
EN ISO 10523:2012
PN-73/C-04576-14
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-4:1999 zał. A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 PN-77/C-04584
PN-EN ISO 5667-6:2016-12 z wył. pkt 7.5
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010 + Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
PN-Z 11001-3:2000 zał. A
RB-01.07 wyd. II z dn. 27.06.2016 r. PN-77/C-04584
RB-07.01 wyd. III z dn. 02.05.2016 r. na podstawie testu Hach Lange LCK 153; LCK 353
RB-07.08 wyd. III z dn. 30.09.2014 r. na podstawie testu Merck 1.09701
RB-07.09 wyd. III z dn. 09.03.2015 r. na podstawie testu Hach Lange LCK332
RB-07.13 wyd. IV z dnia 01.03.2018 r. na podstawie testu Nanocolor 91805
RB-07.22 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8326
RB-07.23 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8008
RB-07.24 wyd. I z dn. 30.09.2014 r. na podstawie testu Hach 8149
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8021 i 8167
RB-07.25 wyd. II z dn. 01.04.2016 r. na podstawie testu Hach 8167
RB-07.26 wyd. I z dn. 20.01.2017 r.
RB-07.32 wyd. II z dnia 08.06.2021 r. na podstawie testu Nanocolor 985 083 i 985 088
RB-07.33 wyd. I z dnia 01.03.2018 r. Na podstawie testu Idexx Enterolert - E
RB-07.34 wyd. I z dnia 01.08.2019 na podstawie testu Nanocolor 985 067