🇵🇱 LABORATORIUM BADAWCZE INTERLABO PL

PCA AB 1365 • Warszawa, Poland • 72 methods

Water & wastewaterEnvironmentMaterials & polymers

LABORATORIUM BADAWCZE INTERLABO is a laboratory accredited by PCA under number AB 1365 (Warszawa, Poland). Its accreditation scope covers 72 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Wastewater, Water, water intended for human consumption, Sewage sludge, Soil.

At a glance

  • Accreditation number: PCA AB 1365
  • Methods in scope: 72
  • Types of test objects: 14
  • City: Warszawa, Poland
Accreditation number
AB 1365
Accreditation body
PCA
Address
A. TOMASZEWSKI, M. TOMASZEWSKI SPÓŁKA JAWNA, ul. L. Rydygiera 8, lokal 20/137, 01-793 Warszawa
City
Warszawa, Poland

What this laboratory tests (14)

Accreditation scope — test methods (72)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Soil Sampling for chemical and physical testing PN-R-04031:1997 PN-ISO 10381-5:2009
2 Soil pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 10390:2022-09
3 Soil Metal content *) Range: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Flame atomic absorption spectrometry (FAAS) PN-ISO 11047:2001 pkt 3
4 Soil Mercury content Range: (0,50 – 5,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method ILB3b-01 wydanie 6 z 31.08.2020 r.
5 Soil Available phosphorus content Range: (1,0 – 50,0) mg/100g Spectrophotometric method ILB3b-02 wydanie 7 z 26.07.2021 r.
6 Soil Dry matter / water content Range: (70,0 – 99,5) % Gravimetric method PN-ISO 11465:1999
7 Soil Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,10 – 75) % Gravimetric method ILB3b-23 wydanie 5 z 26.07.2021 r.
8 Sewage sludge pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 12176:2004
9 Sewage sludge Metal content *) Range: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-ISO 8288:2002
10 Sewage sludge Chromium content *) Range: (5,0 – 2500) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-EN 1233:2000 pkt 3
11 Sewage sludge Metal content *) Range: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-EN ISO 7980:2002
12 Sewage sludge Mercury content Range: (0,50 – 25,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method ILB3b-01 wydanie 6 z 31.08.2020 r.
13 Sewage sludge Sampling for chemical, physical, microbiological and parasitological testing PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5
14 Sewage sludge Total phosphorus content Range: (0,50 – 4,0) % Spectrophotometric method ILB3b-03 wydanie 7 z 26.07.2021 r.
15 Sewage sludge, plant cultivation aids: - soil improvers Dry matter content Range: (1,0 – 99,0) % Gravimetric method PN-EN 12880:2004
16 Sewage sludge, plant cultivation aids: - soil improvers Loss on ignition Range: (5,0 – 90,0) % Gravimetric method PN-EN 12879:2004
17 Sewage sludge, plant cultivation aids: - soil improvers Kjeldahl nitrogen content Range: (0,50 – 12,0) % Titrimetric method PN-EN 13342:2002
18 Sewage sludge, plant cultivation aids: - soil improvers Ammonium nitrogen content Range: (0,05 – 5,0) % Titrimetric method PN-ISO 5664:2002 PN-EN 14671:2007
19 Plant cultivation aids: - soil improvers Sampling for chemical and physical testing PN-EN 12579:2024-09
20 Plant cultivation aids: - soil improvers pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 10390:2022-09
21 Sewage sludge, soil, plant cultivation aids: - soil property improving agents Content of elements: Range: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r.
22 Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 35) ºC PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.
23 Wastewater pH Range: 3,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
24 Wastewater Metal concentrations *) Range: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002
25 Wastewater Chromium concentration *) Range: (0,50 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) PN-EN 1233:2000 pkt 3
26 Wastewater Mercury concentration Range: (0,0025 – 5,0) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r.
27 Wastewater Total phosphorus concentration Range: (0,10 – 40,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
28 Wastewater Nitrate nitrogen concentration Range: (0,10 – 50,0) mg/l N-NO 3 Spectrophotometric method PN-82/C-04576/08
29 Wastewater Nitrite nitrogen concentration Range: (0,010 – 10,0) mg/l N-NO 2 Spectrophotometric method PN-EN 26777:1999
30 Wastewater Ammonium nitrogen concentration N-NH 4 Range: (0,50 – 320) mg/l Titrimetric method PN-ISO 5664:2002
31 Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 700) mg/l Titrimetric method PN-EN 25663:2001
32 Wastewater Total nitrogen concentration (calculated) ILB3b-04 wydanie 6 z 26.07.2021 r.
33 Wastewater Iron concentration Range: (0,010 – 5,0) mg/l Spectrophotometric method PN-ISO 6332:2001 pkt. 7.1.1
34 Wastewater Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.
35 Wastewater Chemical oxygen demand - COD-Cr Range: (5,0 – 10000) mg/l Spectrophotometric method PN-ISO 15705:2005
36 Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 20000) mg/l O 2 Titrimetric method PN-ISO 6060:2006
37 Wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
38 Wastewater Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
39 Wastewater Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method PN-ISO 9297:1994
40 Wastewater Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method PN-EN 27888:1999
41 Water, water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2
42 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
43 Water, water intended for human consumption Nitrite nitrogen concentration Range: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Spectrophotometric method PN-EN 26777:1999
44 Water, water intended for human consumption Nitrate nitrogen concentration Range: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Spectrophotometric method PN-82/C-04576.08
45 Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Spectrophotometric method PN-ISO 7150-1:2002
46 Water, water intended for human consumption Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012
47 Water, water intended for human consumption Manganese concentration Range: (0,01 – 1) mg/l Spectrophotometric method ILB3b-12 wydanie 5 z 26.07.2021 r.
48 Water, water intended for human consumption Iron concentration Range: (0,01 – 5) mg/l Spectrophotometric method PN-ISO 6332:2001
49 Water, water intended for human consumption Turbidity Range: (0,2 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
50 Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l Titrimetric method PN-ISO 6059:1999
51 Water, water intended for human consumption Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method PN-ISO 9297:1994
52 Water, water intended for human consumption Sodium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 9964-1/Ak:1997
53 Water, water intended for human consumption Potassium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 9964-2:1994
54 Water, water intended for human consumption Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method PN-EN 27888:1999
55 Water, water intended for human consumption Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.
56 Water Chemical oxygen demand - COD Range: (5,0 – 10000) mg/l Spectrophotometric method PN-ISO 15705:2005
57 Water, water intended for human consumption Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
58 Water, water intended for human consumption pH Range: 3,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
59 Water, water intended for human consumption, wastewater Content of elements: Range: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN ISO 11885:2009
60 Water, water intended for human consumption, wastewater Content of elements: Range: Hg (0,0002 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique method ILB3b-5 wydanie 2 z 31.08.2020 r.
61 Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019
62 Water, water intended for human consumption, wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
63 Waste O): code 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,1 – 99,9) % Gravimetric method PN-EN 12879:2004
64 Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Dry matter / water content Range: (0,10 – 99,9) % Gravimetric method PN-EN 12880:2004
65 Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 pH Range: 3,0 – 10,0 Potentiometric method PN-EN 12457-4:2006 PN-EN ISO 10523:2012
66 Waste O): code 19 08 01, 19 08 02 Metal content: *) Range: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 PN-ISO 8288:2002
67 Waste O): code 19 08 01, 19 08 02 Chromium content: *) Range: Cr (5,0 – 5000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3
68 Waste O): code 19 08 01, 19 08 02 Metal content: *) Range: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.
69 Waste O): code 19 08 01, 19 08 02 Mercury content Range: (0,05 – 10) mg/kg Cold mercury vapour atomic absorption spectrometry (CVAAS) method PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.
70 Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 Chloride content Range: (50 – 20000) mg/kg Titrimetric method PN-EN 12457-4:2006 PN-ISO 9297:1994
71 Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 Fluoride content Range: (1,0 – 15,0) mg/kg Spectrophotometric method PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
72 Waste O): code 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Sampling for chemical and physical testing ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006

Reference standards (60)

ILB3b-01 wydanie 6 z 31.08.2020 r.
ILB3b-02 wydanie 7 z 26.07.2021 r.
ILB3b-03 wydanie 7 z 26.07.2021 r.
ILB3b-04 wydanie 6 z 26.07.2021 r.
ILB3b-12 wydanie 5 z 26.07.2021 r.
ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006
ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
ILB3b-16 wydanie 4 z 31.08.2020 r.
ILB3b-23 wydanie 5 z 26.07.2021 r.
ILB3b-5 wydanie 2 z 31.08.2020 r.
PN-82/C-04576.08
PN-82/C-04576/08
PN-EN 1233:2000 pkt 3
PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.
PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.
PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3
PN-EN 12457-4:2006 PN-EN ISO 10523:2012
PN-EN 12457-4:2006 PN-ISO 8288:2002
PN-EN 12457-4:2006 PN-ISO 9297:1994
PN-EN 12579:2024-09
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 13346:2002 PN-EN 1233:2000 pkt 3
PN-EN 13346:2002 PN-EN ISO 7980:2002
PN-EN 13346:2002 PN-ISO 8288:2002
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r.
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-ISO 10390:2022-09
PN-ISO 11047:2001 pkt 3
PN-ISO 11465:1999
PN-ISO 12176:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5664:2002 PN-EN 14671:2007
PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.
PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5
PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001
PN-ISO 6332:2001 pkt. 7.1.1
PN-ISO 7150-1:2002
PN-ISO 8288:2002
PN-ISO 9297:1994
PN-ISO 9964-1/Ak:1997
PN-ISO 9964-2:1994
PN-R-04031:1997 PN-ISO 10381-5:2009