🇵🇱 LABORATORIUM BADAWCZE INTERLABO PL
Water & wastewaterEnvironmentMaterials & polymers
LABORATORIUM BADAWCZE INTERLABO is a laboratory accredited by PCA under number AB 1365 (Warszawa, Poland). Its accreditation scope covers 72 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Wastewater, Water, water intended for human consumption, Sewage sludge, Soil.
At a glance
- Accreditation number: PCA AB 1365
- Methods in scope: 72
- Types of test objects: 14
- City: Warszawa, Poland
- Accreditation number
- AB 1365
- Accreditation body
- PCA
- Address
- A. TOMASZEWSKI, M. TOMASZEWSKI SPÓŁKA JAWNA, ul. L. Rydygiera 8, lokal 20/137, 01-793 Warszawa
- City
- Warszawa, Poland
What this laboratory tests (14)
- Wastewater — 19 methods
- Water, water intended for human consumption — 17 methods
- Sewage sludge — 7 methods
- Soil — 7 methods
- Sewage sludge, plant cultivation aids: - soil improvers — 4 methods
- Waste O): code 19 08 01, 19 08 02 — 4 methods
- Water, water intended for human consumption, wastewater — 4 methods
- Plant cultivation aids: - soil improvers — 2 methods
- Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 — 2 methods
- Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 — 2 methods
- Sewage sludge, soil, plant cultivation aids: - soil property improving agents — 1 method
- Waste O): code 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 — 1 method
- Waste O): code 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 — 1 method
- Water — 1 method
Accreditation scope — test methods (72)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 PN-ISO 10381-5:2009 | ||
| 2 | Soil | pH Range: 3,0 – 10,0 Potentiometric method | PN-ISO 10390:2022-09 | ||
| 3 | Soil | Metal content *) Range: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-ISO 11047:2001 pkt 3 | ||
| 4 | Soil | Mercury content Range: (0,50 – 5,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method | ILB3b-01 wydanie 6 z 31.08.2020 r. | ||
| 5 | Soil | Available phosphorus content Range: (1,0 – 50,0) mg/100g Spectrophotometric method | ILB3b-02 wydanie 7 z 26.07.2021 r. | ||
| 6 | Soil | Dry matter / water content Range: (70,0 – 99,5) % Gravimetric method | PN-ISO 11465:1999 | ||
| 7 | Soil | Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,10 – 75) % Gravimetric method | ILB3b-23 wydanie 5 z 26.07.2021 r. | ||
| 8 | Sewage sludge | pH Range: 3,0 – 10,0 Potentiometric method | PN-ISO 12176:2004 | ||
| 9 | Sewage sludge | Metal content *) Range: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-EN 13346:2002 PN-ISO 8288:2002 | ||
| 10 | Sewage sludge | Chromium content *) Range: (5,0 – 2500) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-EN 13346:2002 PN-EN 1233:2000 pkt 3 | ||
| 11 | Sewage sludge | Metal content *) Range: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Flame atomic absorption spectrometry (FAAS) | PN-EN 13346:2002 PN-EN ISO 7980:2002 | ||
| 12 | Sewage sludge | Mercury content Range: (0,50 – 25,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method | ILB3b-01 wydanie 6 z 31.08.2020 r. | ||
| 13 | Sewage sludge | Sampling for chemical, physical, microbiological and parasitological testing | PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5 | ||
| 14 | Sewage sludge | Total phosphorus content Range: (0,50 – 4,0) % Spectrophotometric method | ILB3b-03 wydanie 7 z 26.07.2021 r. | ||
| 15 | Sewage sludge, plant cultivation aids: - soil improvers | Dry matter content Range: (1,0 – 99,0) % Gravimetric method | PN-EN 12880:2004 | ||
| 16 | Sewage sludge, plant cultivation aids: - soil improvers | Loss on ignition Range: (5,0 – 90,0) % Gravimetric method | PN-EN 12879:2004 | ||
| 17 | Sewage sludge, plant cultivation aids: - soil improvers | Kjeldahl nitrogen content Range: (0,50 – 12,0) % Titrimetric method | PN-EN 13342:2002 | ||
| 18 | Sewage sludge, plant cultivation aids: - soil improvers | Ammonium nitrogen content Range: (0,05 – 5,0) % Titrimetric method | PN-ISO 5664:2002 PN-EN 14671:2007 | ||
| 19 | Plant cultivation aids: - soil improvers | Sampling for chemical and physical testing | PN-EN 12579:2024-09 | ||
| 20 | Plant cultivation aids: - soil improvers | pH Range: 3,0 – 10,0 Potentiometric method | PN-ISO 10390:2022-09 | ||
| 21 | Sewage sludge, soil, plant cultivation aids: - soil property improving agents | Content of elements: Range: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method | PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r. | ||
| 22 | Wastewater | Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 35) ºC | PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r. | ||
| 23 | Wastewater | pH Range: 3,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 24 | Wastewater | Metal concentrations *) Range: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 | ||
| 25 | Wastewater | Chromium concentration *) Range: (0,50 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-EN 1233:2000 pkt 3 | ||
| 26 | Wastewater | Mercury concentration Range: (0,0025 – 5,0) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) | ILB3b-01 wydanie 6 z 31.08.2020 r. | ||
| 27 | Wastewater | Total phosphorus concentration Range: (0,10 – 40,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | ||
| 28 | Wastewater | Nitrate nitrogen concentration Range: (0,10 – 50,0) mg/l N-NO 3 Spectrophotometric method | PN-82/C-04576/08 | ||
| 29 | Wastewater | Nitrite nitrogen concentration Range: (0,010 – 10,0) mg/l N-NO 2 Spectrophotometric method | PN-EN 26777:1999 | ||
| 30 | Wastewater | Ammonium nitrogen concentration N-NH 4 Range: (0,50 – 320) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 31 | Wastewater | Kjeldahl nitrogen concentration Range: (1,0 – 700) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 32 | Wastewater | Total nitrogen concentration (calculated) | ILB3b-04 wydanie 6 z 26.07.2021 r. | ||
| 33 | Wastewater | Iron concentration Range: (0,010 – 5,0) mg/l Spectrophotometric method | PN-ISO 6332:2001 pkt. 7.1.1 | ||
| 34 | Wastewater | Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) | ILB3b-16 wydanie 4 z 31.08.2020 r. | ||
| 35 | Wastewater | Chemical oxygen demand - COD-Cr Range: (5,0 – 10000) mg/l Spectrophotometric method | PN-ISO 15705:2005 | ||
| 36 | Wastewater | Chemical oxygen demand - COD-Cr Range: (30 – 20000) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 37 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 38 | Wastewater | Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method | ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 | ||
| 39 | Wastewater | Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 40 | Wastewater | Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 41 | Water, water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 | ||
| 42 | Water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 43 | Water, water intended for human consumption | Nitrite nitrogen concentration Range: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Spectrophotometric method | PN-EN 26777:1999 | ||
| 44 | Water, water intended for human consumption | Nitrate nitrogen concentration Range: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Spectrophotometric method | PN-82/C-04576.08 | ||
| 45 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 46 | Water, water intended for human consumption | Colour Range: (5 – 70) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 | ||
| 47 | Water, water intended for human consumption | Manganese concentration Range: (0,01 – 1) mg/l Spectrophotometric method | ILB3b-12 wydanie 5 z 26.07.2021 r. | ||
| 48 | Water, water intended for human consumption | Iron concentration Range: (0,01 – 5) mg/l Spectrophotometric method | PN-ISO 6332:2001 | ||
| 49 | Water, water intended for human consumption | Turbidity Range: (0,2 – 40) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 50 | Water, water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l Titrimetric method | PN-ISO 6059:1999 | ||
| 51 | Water, water intended for human consumption | Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 52 | Water, water intended for human consumption | Sodium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 9964-1/Ak:1997 | ||
| 53 | Water, water intended for human consumption | Potassium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 9964-2:1994 | ||
| 54 | Water, water intended for human consumption | Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 55 | Water, water intended for human consumption | Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) | ILB3b-16 wydanie 4 z 31.08.2020 r. | ||
| 56 | Water | Chemical oxygen demand - COD Range: (5,0 – 10000) mg/l Spectrophotometric method | PN-ISO 15705:2005 | ||
| 57 | Water, water intended for human consumption | Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method | ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 | ||
| 58 | Water, water intended for human consumption | pH Range: 3,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 59 | Water, water intended for human consumption, wastewater | Content of elements: Range: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Inductively coupled plasma atomic emission spectrometry (ICP-OES) method | PN-EN ISO 11885:2009 | ||
| 60 | Water, water intended for human consumption, wastewater | Content of elements: Range: Hg (0,0002 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique method | ILB3b-5 wydanie 2 z 31.08.2020 r. | ||
| 61 | Water, water intended for human consumption, wastewater | Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019 | ||
| 62 | Water, water intended for human consumption, wastewater | Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 63 | Waste O): code 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 | Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,1 – 99,9) % Gravimetric method | PN-EN 12879:2004 | ||
| 64 | Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 | Dry matter / water content Range: (0,10 – 99,9) % Gravimetric method | PN-EN 12880:2004 | ||
| 65 | Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 | pH Range: 3,0 – 10,0 Potentiometric method | PN-EN 12457-4:2006 PN-EN ISO 10523:2012 | ||
| 66 | Waste O): code 19 08 01, 19 08 02 | Metal content: *) Range: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-EN 12457-4:2006 PN-ISO 8288:2002 | ||
| 67 | Waste O): code 19 08 01, 19 08 02 | Chromium content: *) Range: Cr (5,0 – 5000) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3 | ||
| 68 | Waste O): code 19 08 01, 19 08 02 | Metal content: *) Range: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Flame atomic absorption spectrometry (FAAS) | PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r. | ||
| 69 | Waste O): code 19 08 01, 19 08 02 | Mercury content Range: (0,05 – 10) mg/kg Cold mercury vapour atomic absorption spectrometry (CVAAS) method | PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r. | ||
| 70 | Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 | Chloride content Range: (50 – 20000) mg/kg Titrimetric method | PN-EN 12457-4:2006 PN-ISO 9297:1994 | ||
| 71 | Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 | Fluoride content Range: (1,0 – 15,0) mg/kg Spectrophotometric method | PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 | ||
| 72 | Waste O): code 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 | Sampling for chemical and physical testing | ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006 | ||
Reference standards (60)
ILB3b-01 wydanie 6 z 31.08.2020 r.
ILB3b-02 wydanie 7 z 26.07.2021 r.
ILB3b-03 wydanie 7 z 26.07.2021 r.
ILB3b-04 wydanie 6 z 26.07.2021 r.
ILB3b-12 wydanie 5 z 26.07.2021 r.
ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006
ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
ILB3b-16 wydanie 4 z 31.08.2020 r.
ILB3b-23 wydanie 5 z 26.07.2021 r.
ILB3b-5 wydanie 2 z 31.08.2020 r.
PN-82/C-04576.08
PN-82/C-04576/08
PN-EN 1233:2000 pkt 3
PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.
PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323
PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.
PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3
PN-EN 12457-4:2006 PN-EN ISO 10523:2012
PN-EN 12457-4:2006 PN-ISO 8288:2002
PN-EN 12457-4:2006 PN-ISO 9297:1994
PN-EN 12579:2024-09
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 13346:2002 PN-EN 1233:2000 pkt 3
PN-EN 13346:2002 PN-EN ISO 7980:2002
PN-EN 13346:2002 PN-ISO 8288:2002
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r.
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012
PN-ISO 10390:2022-09
PN-ISO 11047:2001 pkt 3
PN-ISO 11465:1999
PN-ISO 12176:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5664:2002 PN-EN 14671:2007
PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.
PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5
PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001
PN-ISO 6332:2001 pkt. 7.1.1
PN-ISO 7150-1:2002
PN-ISO 8288:2002
PN-ISO 9297:1994
PN-ISO 9964-1/Ak:1997
PN-ISO 9964-2:1994
PN-R-04031:1997 PN-ISO 10381-5:2009