{"lab":{"_id":"69ad52a3de79e566650fb704","accr_number":"AB 1365","country":"PL","accr_body":"PCA","address":"A. TOMASZEWSKI, M. TOMASZEWSKI SPÓŁKA JAWNA, ul. L. Rydygiera 8, lokal 20/137, 01-793 Warszawa","categories":["water","environment","materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":72,"name":"LABORATORIUM BADAWCZE INTERLABO","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1365.pdf"],"scope_summary":"","search_text":"laboratorium badawcze interlabo a. tomaszewski, m. tomaszewski spółka jawna, ul. l. rydygiera 8, lokal 20/137, 01-793 warszawa environment other materials water microbiology pharma electronics","status":"active","updated_at":"2026-03-08T14:50:32.435Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:32.435Z","email_confidence":"high","email_mx":true,"email_source":"https://interlabo.pl/o-nas/","parse_date":"2026-07-17T16:19:04.988Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, sediments"},{"codes":"C/32","pl":"Badania chemiczne odpadów","en":"Chemical tests of waste"},{"codes":"C/44/P","pl":"Badania chemiczne i pobieranie próbek środków wspomagających uprawę roślin","en":"Chemical tests and sampling of plant growth substances"},{"codes":"N/28/P; N/29/P; N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"N/32","pl":"Badania właściwości fizycznych odpadów","en":"Tests of physical properties of waste"},{"codes":"N/44/P","pl":"Badania właściwości fizycznych i pobieranie próbek środków wspomagających uprawę roślin","en":"Tests of physical properties and sampling of plant growth substances"},{"codes":"P/28; P/32","pl":"Pobieranie próbek wody, osadów","en":"Sampling of water, sediments"}],"issue":{"no":"17","date":"13.02.2026"},"map_coord":[52.231958,21.006725],"map_geo":"nominatim-city","has_en":true,"category_counts":{"water":55,"environment":18,"materials":8,"other":2,"microbiology":2},"category_scores":{"water":35.59,"environment":3.81,"materials":0.75,"other":0.05,"microbiology":0.05},"has_zh":true},"methods":[{"_id":"6a5a55f99af9f73f382525e0","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 PN-ISO 10381-5:2009","norm_bases":["PN-R-04031:1997 PN-ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 PN-ISO 10381-5:2009","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 PN-ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e1","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 10390:2022-09 Gleba pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 10390:2022-09","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 10390:2022-09","search_zh":"土壤 pH 范围：3,0 – 10,0 电位法 PN-ISO 10390:2022-09","test_object_zh":"土壤","methodology_zh":"pH 范围：3,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f382525e2","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość metali *) Zakres: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal content *) Range: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali *) Zakres: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 11047:2001 pkt 3","norm_bases":["PN-ISO 11047:2001 pkt 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość metali *) Zakres: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 pkt 3 Gleba Zawartosc metali *) Zakres: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 11047:2001 pkt 3","categories":["materials","environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Metal content *) Range: Pb (5,0 – 100) mg/kg Cd (1,0 – 7,0) mg/kg Ni (5,0 – 100) mg/kg Zn (1,0 – 500) mg/kg Cu (5,0 – 150) mg/kg Cr (5,0 – 150) mg/kg Flame atomic absorption spectrometry (FAAS) PN-ISO 11047:2001 pkt 3","search_zh":"土壤 PN-ISO 11047:2001 pkt 3","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e3","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość rtęci Zakres: (0,50 – 5,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury content Range: (0,50 – 5,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,50 – 5,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"ILB3b-01 wydanie 6 z 31.08.2020 r.","norm_bases":["ILB3b-01 wydanie 6 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość rtęci Zakres: (0,50 – 5,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r. Gleba Zawartosc rteci Zakres: (0,50 – 5,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r.","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Mercury content Range: (0,50 – 5,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method ILB3b-01 wydanie 6 z 31.08.2020 r.","search_zh":"土壤 ILB3b-01 wydanie 6 z 31.08.2020 r.","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e4","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość fosforu przyswajalnego Zakres: (1,0 – 50,0) mg/100g Metoda spektrofotometryczna","methodology_en":"Available phosphorus content Range: (1,0 – 50,0) mg/100g Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fosforu przyswajalnego Zakres: (1,0 – 50,0) mg/100g Metoda spektrofotometryczna","reference":"ILB3b-02 wydanie 7 z 26.07.2021 r.","norm_bases":["ILB3b-02 wydanie 7 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość fosforu przyswajalnego Zakres: (1,0 – 50,0) mg/100g Metoda spektrofotometryczna ILB3b-02 wydanie 7 z 26.07.2021 r. Gleba Zawartosc fosforu przyswajalnego Zakres: (1,0 – 50,0) mg/100g Metoda spektrofotometryczna ILB3b-02 wydanie 7 z 26.07.2021 r.","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Available phosphorus content Range: (1,0 – 50,0) mg/100g Spectrophotometric method ILB3b-02 wydanie 7 z 26.07.2021 r.","search_zh":"土壤 ILB3b-02 wydanie 7 z 26.07.2021 r.","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e5","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Sucha masa / zawartość wody Zakres: (70,0 – 99,5) % Metoda wagowa","methodology_en":"Dry matter / water content Range: (70,0 – 99,5) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa / zawartość wody Zakres: (70,0 – 99,5) % Metoda wagowa","reference":"PN-ISO 11465:1999","norm_bases":["PN-ISO 11465:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Sucha masa / zawartość wody Zakres: (70,0 – 99,5) % Metoda wagowa PN-ISO 11465:1999 Gleba Sucha masa / zawartosc wody Zakres: (70,0 – 99,5) % Metoda wagowa PN-ISO 11465:1999","categories":["water","environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Dry matter / water content Range: (70,0 – 99,5) % Gravimetric method PN-ISO 11465:1999","search_zh":"土壤 PN-ISO 11465:1999","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e6","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,10 – 75) % Metoda wagowa","methodology_en":"Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,10 – 75) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,10 – 75) % Metoda wagowa","reference":"ILB3b-23 wydanie 5 z 26.07.2021 r.","norm_bases":["ILB3b-23 wydanie 5 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,10 – 75) % Metoda wagowa ILB3b-23 wydanie 5 z 26.07.2021 r. Gleba Straty przy prazeniu suchej masy (LOI) / Pozostalosc po prazeniu Zakres: (0,10 – 75) % Metoda wagowa ILB3b-23 wydanie 5 z 26.07.2021 r.","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,10 – 75) % Gravimetric method ILB3b-23 wydanie 5 z 26.07.2021 r.","search_zh":"土壤 ILB3b-23 wydanie 5 z 26.07.2021 r.","test_object_zh":"土壤"},{"_id":"6a5a55f99af9f73f382525e7","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-ISO 12176:2004","norm_bases":["PN-ISO 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 12176:2004 Osady sciekowe pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 12176:2004","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 12176:2004","search_zh":"污泥 pH 范围：3,0 – 10,0 电位法 PN-ISO 12176:2004","test_object_zh":"污泥","methodology_zh":"pH 范围：3,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f382525e8","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość metali *) Zakres: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal content *) Range: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali *) Zakres: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 13346:2002 PN-ISO 8288:2002","norm_bases":["PN-EN 13346:2002 PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość metali *) Zakres: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-ISO 8288:2002 Osady sciekowe Zawartosc metali *) Zakres: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-ISO 8288:2002","categories":["water","materials"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Metal content *) Range: Pb (1,0 – 1500) mg/kg Cd (1,0 – 50) mg/kg Ni (5,0 – 500) mg/kg Zn (5,0 – 5000) mg/kg Cu (5,0 – 2000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-ISO 8288:2002","search_zh":"污泥 PN-EN 13346:2002 PN-ISO 8288:2002","test_object_zh":"污泥"},{"_id":"6a5a55f99af9f73f382525e9","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość chromu *) Zakres: (5,0 – 2500) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Chromium content *) Range: (5,0 – 2500) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chromu *) Zakres: (5,0 – 2500) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 13346:2002 PN-EN 1233:2000 pkt 3","norm_bases":["PN-EN 13346:2002 PN-EN 1233:2000 pkt 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość chromu *) Zakres: (5,0 – 2500) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-EN 1233:2000 pkt 3 Osady sciekowe Zawartosc chromu *) Zakres: (5,0 – 2500) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-EN 1233:2000 pkt 3","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Chromium content *) Range: (5,0 – 2500) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-EN 1233:2000 pkt 3","search_zh":"污泥 PN-EN 13346:2002 PN-EN 1233:2000 pkt 3","test_object_zh":"污泥"},{"_id":"6a5a55f99af9f73f382525ea","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość metali *) Zakres: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal content *) Range: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali *) Zakres: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 13346:2002 PN-EN ISO 7980:2002","norm_bases":["PN-EN 13346:2002 PN-EN ISO 7980:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość metali *) Zakres: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-EN ISO 7980:2002 Osady sciekowe Zawartosc metali *) Zakres: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 13346:2002 PN-EN ISO 7980:2002","categories":["water","materials"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Metal content *) Range: Ca (2,0 – 50,0) % Mg (0,20 – 5,0) % Flame atomic absorption spectrometry (FAAS) PN-EN 13346:2002 PN-EN ISO 7980:2002","search_zh":"污泥 PN-EN 13346:2002 PN-EN ISO 7980:2002","test_object_zh":"污泥"},{"_id":"6a5a55f99af9f73f382525eb","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość rtęci Zakres: (0,50 – 25,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury content Range: (0,50 – 25,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,50 – 25,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"ILB3b-01 wydanie 6 z 31.08.2020 r.","norm_bases":["ILB3b-01 wydanie 6 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość rtęci Zakres: (0,50 – 25,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r. Osady sciekowe Zawartosc rteci Zakres: (0,50 – 25,0) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r.","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Mercury content Range: (0,50 – 25,0) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method ILB3b-01 wydanie 6 z 31.08.2020 r.","search_zh":"污泥 ILB3b-01 wydanie 6 z 31.08.2020 r.","test_object_zh":"污泥"},{"_id":"6a5a55f99af9f73f382525ec","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","methodology_en":"Sampling for chemical, physical, microbiological and parasitological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5","norm_bases":["PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych, mikrobiologicznych i parazytologicznych PN-ISO 5667-13:2011 z wylaczeniem pkt 6.3.8.5","categories":["water","microbiology"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Sampling for chemical, physical, microbiological and parasitological testing PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5","search_zh":"污泥 用于化学、物理、微生物与寄生虫学检验的采样 PN-ISO 5667-13:2011 z wyłączeniem pkt 6.3.8.5","test_object_zh":"污泥","methodology_zh":"用于化学、物理、微生物与寄生虫学检验的采样"},{"_id":"6a5a55f99af9f73f382525ed","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego Zakres: (0,50 – 4,0) % Metoda spektrofotometryczna","methodology_en":"Total phosphorus content Range: (0,50 – 4,0) % Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego Zakres: (0,50 – 4,0) % Metoda spektrofotometryczna","reference":"ILB3b-03 wydanie 7 z 26.07.2021 r.","norm_bases":["ILB3b-03 wydanie 7 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego Zakres: (0,50 – 4,0) % Metoda spektrofotometryczna ILB3b-03 wydanie 7 z 26.07.2021 r. Osady sciekowe Zawartosc fosforu ogolnego Zakres: (0,50 – 4,0) % Metoda spektrofotometryczna ILB3b-03 wydanie 7 z 26.07.2021 r.","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Total phosphorus content Range: (0,50 – 4,0) % Spectrophotometric method ILB3b-03 wydanie 7 z 26.07.2021 r.","search_zh":"污泥 ILB3b-03 wydanie 7 z 26.07.2021 r.","test_object_zh":"污泥"},{"_id":"6a5a55f99af9f73f382525ee","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, plant cultivation aids: - soil improvers","methodology":"Zawartość suchej masy Zakres: (1,0 – 99,0) % Metoda wagowa","methodology_en":"Dry matter content Range: (1,0 – 99,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość suchej masy Zakres: (1,0 – 99,0) % Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość suchej masy Zakres: (1,0 – 99,0) % Metoda wagowa PN-EN 12880:2004 Osady sciekowe, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc suchej masy Zakres: (1,0 – 99,0) % Metoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, plant cultivation aids: - soil improvers Dry matter content Range: (1,0 – 99,0) % Gravimetric method PN-EN 12880:2004","search_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂 PN-EN 12880:2004","test_object_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5a55f99af9f73f382525ef","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, plant cultivation aids: - soil improvers","methodology":"Straty przy prażeniu Zakres: (5,0 – 90,0) % Metoda wagowa","methodology_en":"Loss on ignition Range: (5,0 – 90,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Straty przy prażeniu Zakres: (5,0 – 90,0) % Metoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Straty przy prażeniu Zakres: (5,0 – 90,0) % Metoda wagowa PN-EN 12879:2004 Osady sciekowe, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Straty przy prazeniu Zakres: (5,0 – 90,0) % Metoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, plant cultivation aids: - soil improvers Loss on ignition Range: (5,0 – 90,0) % Gravimetric method PN-EN 12879:2004","search_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂 PN-EN 12879:2004","test_object_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5a55f99af9f73f382525f0","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, plant cultivation aids: - soil improvers","methodology":"Zawartość azotu Kjeldahla Zakres: (0,50 – 12,0) % Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen content Range: (0,50 – 12,0) % Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla Zakres: (0,50 – 12,0) % Metoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość azotu Kjeldahla Zakres: (0,50 – 12,0) % Metoda miareczkowa PN-EN 13342:2002 Osady sciekowe, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc azotu Kjeldahla Zakres: (0,50 – 12,0) % Metoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, plant cultivation aids: - soil improvers Kjeldahl nitrogen content Range: (0,50 – 12,0) % Titrimetric method PN-EN 13342:2002","search_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂 PN-EN 13342:2002","test_object_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5a55f99af9f73f382525f1","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, plant cultivation aids: - soil improvers","methodology":"Zawartość azotu amonowego Zakres: (0,05 – 5,0) % Metoda miareczkowa","methodology_en":"Ammonium nitrogen content Range: (0,05 – 5,0) % Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego Zakres: (0,05 – 5,0) % Metoda miareczkowa","reference":"PN-ISO 5664:2002 PN-EN 14671:2007","norm_bases":["PN-ISO 5664:2002 PN-EN 14671:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość azotu amonowego Zakres: (0,05 – 5,0) % Metoda miareczkowa PN-ISO 5664:2002 PN-EN 14671:2007 Osady sciekowe, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc azotu amonowego Zakres: (0,05 – 5,0) % Metoda miareczkowa PN-ISO 5664:2002 PN-EN 14671:2007","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, plant cultivation aids: - soil improvers Ammonium nitrogen content Range: (0,05 – 5,0) % Titrimetric method PN-ISO 5664:2002 PN-EN 14671:2007","search_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂 PN-ISO 5664:2002 PN-EN 14671:2007","test_object_zh":"污水污泥、植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5a55f99af9f73f382525f2","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN 12579:2024-09","norm_bases":["PN-EN 12579:2024-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Pobieranie próbek do badań chemicznych i fizycznych PN-EN 12579:2024-09 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Pobieranie probek do badan chemicznych i fizycznych PN-EN 12579:2024-09","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plant cultivation aids: - soil improvers Sampling for chemical and physical testing PN-EN 12579:2024-09","methodology_zh":"化学与物理检测用样品采集","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 化学与物理检测用样品采集 PN-EN 12579:2024-09","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂"},{"_id":"6a5a55f99af9f73f382525f3","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Plant cultivation aids: - soil improvers","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-ISO 10390:2022-09","norm_bases":["PN-ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 10390:2022-09 Srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-ISO 10390:2022-09","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Plant cultivation aids: - soil improvers pH Range: 3,0 – 10,0 Potentiometric method PN-ISO 10390:2022-09","search_zh":"植物栽培辅助制剂：－ 土壤改良剂 pH 范围：3,0 – 10,0 电位法 PN-ISO 10390:2022-09","test_object_zh":"植物栽培辅助制剂：－ 土壤改良剂","methodology_zh":"pH 范围：3,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f382525f4","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Osady ściekowe, gleba, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby","test_object_en":"Sewage sludge, soil, plant cultivation aids: - soil property improving agents","methodology":"Zawartość pierwiastków: Zakres: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Content of elements: Range: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: Zakres: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r.","norm_bases":["PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, gleba, środki wspomagające uprawę roślin: - środki poprawiające właściwości gleby Zawartość pierwiastków: Zakres: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r. Osady sciekowe, gleba, srodki wspomagajace uprawe roslin: - srodki poprawiajace wlasciwosci gleby Zawartosc pierwiastkow: Zakres: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r.","categories":["water","environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge, soil, plant cultivation aids: - soil property improving agents Content of elements: Range: Ca (0,01 – 100000) mg/kg Cd (0,01 – 1000) mg/kg Cr (0,01 – 1000) mg/kg Cu (0,01 – 1000) mg/kg K (0,01 – 100000) mg/kg Mg (0,01 – 100000) mg/kg Ni (0,01 – 1000) mg/kg Pb (0,01 – 1000) mg/kg Zn (0,01 – 10000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN ISO 11885:2009 ILB3b-25 wydanie 5 z 10.01.2024 r."},{"_id":"6a5a55f99af9f73f382525f5","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 35) ºC","methodology_en":"Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 35) ºC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 35) ºC","reference":"PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.","norm_bases":["PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 35) ºC PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r. Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej probki sciekow Zakres: (5 – 35) ºC PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 35) ºC PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.","search_zh":"污水 PN-ISO 5667-10:2021-11 ILB3b-24 wydanie 5 z 26.07.2021 r.","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525f6","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: 3,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 pH 范围：3,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"污水","methodology_zh":"pH 范围：3,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f382525f7","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie metali *) Zakres: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal concentrations *) Range: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali *) Zakres: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002","norm_bases":["PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie metali *) Zakres: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Scieki Stezenie metali *) Zakres: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002","categories":["materials","water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Metal concentrations *) Range: Pb (0,20 – 50,0) mg/l Cd (0,10 – 10,0) mg/l Ni (0,20 – 10,0) mg/l Zn (0,10 – 500) mg/l Cu (0,10 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002","search_zh":"污水 PN-ISO 8288:2002","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525f8","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chromu *) Zakres: (0,50 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Chromium concentration *) Range: (0,50 – 100) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu *) Zakres: (0,50 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 pkt 3","norm_bases":["PN-EN 1233:2000 pkt 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chromu *) Zakres: (0,50 – 100) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 pkt 3 Scieki Stezenie chromu *) Zakres: (0,50 – 100) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 pkt 3","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chromium concentration *) Range: (0,50 – 100) mg/l Flame atomic absorption spectrometry method (FAAS) PN-EN 1233:2000 pkt 3","search_zh":"污水 PN-EN 1233:2000 pkt 3","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525f9","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci Zakres: (0,0025 – 5,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury concentration Range: (0,0025 – 5,0) mg/l Cold vapour atomic absorption spectrometry method (CVAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,0025 – 5,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"ILB3b-01 wydanie 6 z 31.08.2020 r.","norm_bases":["ILB3b-01 wydanie 6 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci Zakres: (0,0025 – 5,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r. Scieki Stezenie rteci Zakres: (0,0025 – 5,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r.","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Mercury concentration Range: (0,0025 – 5,0) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) ILB3b-01 wydanie 6 z 31.08.2020 r.","search_zh":"污水 ILB3b-01 wydanie 6 z 31.08.2020 r.","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525fa","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,10 – 40,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,10 – 40,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,10 – 40,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,10 – 40,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,10 – 40,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,10 – 40,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525fb","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 50,0) mg/l N-NO 3 Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 50,0) mg/l N-NO 3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 50,0) mg/l N-NO 3 Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 50,0) mg/l N-NO 3 Metoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego Zakres: (0,10 – 50,0) mg/l N-NO 3 Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate nitrogen concentration Range: (0,10 – 50,0) mg/l N-NO 3 Spectrophotometric method PN-82/C-04576/08","search_zh":"污水 PN-82/C-04576/08","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525fc","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,010 – 10,0) mg/l N-NO 2 Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,010 – 10,0) mg/l N-NO 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,010 – 10,0) mg/l N-NO 2 Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,010 – 10,0) mg/l N-NO 2 Metoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,010 – 10,0) mg/l N-NO 2 Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,010 – 10,0) mg/l N-NO 2 Spectrophotometric method PN-EN 26777:1999","search_zh":"污水 PN-EN 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525fd","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego N-NH 4 Zakres: (0,50 – 320) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration N-NH 4 Range: (0,50 – 320) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego N-NH 4 Zakres: (0,50 – 320) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego N-NH 4 Zakres: (0,50 – 320) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego N-NH 4 Zakres: (0,50 – 320) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration N-NH 4 Range: (0,50 – 320) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525fe","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,0 – 700) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,0 – 700) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,0 – 700) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla Zakres: (1,0 – 700) mg/l Metoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla Zakres: (1,0 – 700) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 700) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"污水 PN-EN 25663:2001","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f382525ff","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"ILB3b-04 wydanie 6 z 26.07.2021 r.","norm_bases":["ILB3b-04 wydanie 6 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) ILB3b-04 wydanie 6 z 26.07.2021 r. Scieki Stezenie azotu ogolnego (z obliczen) ILB3b-04 wydanie 6 z 26.07.2021 r.","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) ILB3b-04 wydanie 6 z 26.07.2021 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） ILB3b-04 wydanie 6 z 26.07.2021 r.","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252600","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie żelaza Zakres: (0,010 – 5,0) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,010 – 5,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,010 – 5,0) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001 pkt. 7.1.1","norm_bases":["PN-ISO 6332:2001 pkt. 7.1.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie żelaza Zakres: (0,010 – 5,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.1.1 Scieki Stezenie zelaza Zakres: (0,010 – 5,0) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 pkt. 7.1.1","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Iron concentration Range: (0,010 – 5,0) mg/l Spectrophotometric method PN-ISO 6332:2001 pkt. 7.1.1","search_zh":"污水 PN-ISO 6332:2001 pkt. 7.1.1","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252601","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"ILB3b-16 wydanie 4 z 31.08.2020 r.","norm_bases":["ILB3b-16 wydanie 4 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r. Scieki Stezenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.","categories":["materials","water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.","search_zh":"污水 ILB3b-16 wydanie 4 z 31.08.2020 r.","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252602","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (5,0 – 10000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD-Cr Range: (5,0 – 10000) mg/l Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252603","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 20000) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD-Cr Range: (30 – 20000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 20000) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 20000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 20000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 20000) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"污水 PN-ISO 6060:2006","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252604","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"污水 PN-EN 1899-2:2002","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252605","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna","reference":"ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","norm_bases":["ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 Scieki Stezenie fluorkow Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","search_zh":"污水 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","test_object_zh":"污水"},{"_id":"6a5a55f99af9f73f38252606","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"污水","methodology_zh":"氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法"},{"_id":"6a5a55f99af9f73f38252607","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"污水 电导率 范围：(10 – 3000) µS/cm 电导法 PN-EN 27888:1999","test_object_zh":"污水","methodology_zh":"电导率 范围：(10 – 3000) µS/cm 电导法"},{"_id":"6a5a55f99af9f73f38252608","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2","norm_bases":["PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2 Woda, woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wylaczeniem pkt 5.2","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2","methodology_zh":"化学与物理检测用样品采集","search_zh":"水、生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 PN-ISO 5667-6:2016-12 PN-ISO 5667-11:2017-10 z wyłączeniem pkt 5.2","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252609","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f3825260a","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotynowego Zakres: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Metoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotu azotynowego Zakres: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrite nitrogen concentration Range: (0,010 – 10) mg/l N-NO 2 (0,033 – 33) mg/l NO 2 Spectrophotometric method PN-EN 26777:1999","search_zh":"水、生活饮用水 PN-EN 26777:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f3825260b","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Metoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotu azotanowego Zakres: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrate nitrogen concentration Range: (0,10 – 50) mg/l N-NO 3 (0,4 – 222) mg/l NO 3 Spectrophotometric method PN-82/C-04576.08","search_zh":"水、生活饮用水 PN-82/C-04576.08","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f3825260c","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 3,00) mg/l N-NH 4 (0,06 – 3,86) mg/l NH 4 Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f3825260d","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 – 70) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Woda, woda do spozycia przez ludzi Barwa Zakres: (5 – 70) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (5 – 70) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012","search_zh":"水、生活饮用水 色度 范围：(5 – 70) mg/l Pt 分光光度法 PN-EN ISO 7887:2012","test_object_zh":"水、生活饮用水","methodology_zh":"色度 范围：(5 – 70) mg/l Pt 分光光度法"},{"_id":"6a5a55f99af9f73f3825260e","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu Zakres: (0,01 – 1) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,01 – 1) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,01 – 1) mg/l Metoda spektrofotometryczna","reference":"ILB3b-12 wydanie 5 z 26.07.2021 r.","norm_bases":["ILB3b-12 wydanie 5 z 26.07.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu Zakres: (0,01 – 1) mg/l Metoda spektrofotometryczna ILB3b-12 wydanie 5 z 26.07.2021 r. Woda, woda do spozycia przez ludzi Stezenie manganu Zakres: (0,01 – 1) mg/l Metoda spektrofotometryczna ILB3b-12 wydanie 5 z 26.07.2021 r.","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Manganese concentration Range: (0,01 – 1) mg/l Spectrophotometric method ILB3b-12 wydanie 5 z 26.07.2021 r.","search_zh":"水、生活饮用水 ILB3b-12 wydanie 5 z 26.07.2021 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f3825260f","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza Zakres: (0,01 – 5) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,01 – 5) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,01 – 5) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001","norm_bases":["PN-ISO 6332:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza Zakres: (0,01 – 5) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001 Woda, woda do spozycia przez ludzi Stezenie zelaza Zakres: (0,01 – 5) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Iron concentration Range: (0,01 – 5) mg/l Spectrophotometric method PN-ISO 6332:2001","search_zh":"水、生活饮用水 PN-ISO 6332:2001","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252610","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność Zakres: (0,2 – 40) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,2 – 40) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,2 – 40) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność Zakres: (0,2 – 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc Zakres: (0,2 – 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Turbidity Range: (0,2 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水、生活饮用水 PN-EN ISO 7027-1:2016-09","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252611","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 1000) mg/l Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5 – 1000) mg/l Metoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5 – 1000) mg/l Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5 – 1000) mg/l Titrimetric method PN-ISO 6059:1999","search_zh":"水、生活饮用水 PN-ISO 6059:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252612","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、生活饮用水 氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水、生活饮用水","methodology_zh":"氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法"},{"_id":"6a5a55f99af9f73f38252613","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie sodu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Sodium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie sodu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1/Ak:1997","norm_bases":["PN-ISO 9964-1/Ak:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie sodu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1/Ak:1997 Woda, woda do spozycia przez ludzi Stezenie sodu *) Zakres: (1,0 – 300) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1/Ak:1997","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sodium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 9964-1/Ak:1997","search_zh":"水、生活饮用水 PN-ISO 9964-1/Ak:1997","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252614","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie potasu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Potassium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie potasu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994","norm_bases":["PN-ISO 9964-2:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie potasu *) Zakres: (1,0 – 300) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994 Woda, woda do spozycia przez ludzi Stezenie potasu *) Zakres: (1,0 – 300) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Potassium concentration *) Range: (1,0 – 300) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 9964-2:1994","search_zh":"水、生活饮用水 PN-ISO 9964-2:1994","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252615","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水 电导率 范围：(10 – 3000) µS/cm 电导法 PN-EN 27888:1999","test_object_zh":"水、生活饮用水","methodology_zh":"电导率 范围：(10 – 3000) µS/cm 电导法"},{"_id":"6a5a55f99af9f73f38252616","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"ILB3b-16 wydanie 4 z 31.08.2020 r.","norm_bases":["ILB3b-16 wydanie 4 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r. Woda, woda do spozycia przez ludzi Stezenie metali: *) Zakres: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.","categories":["materials","water"],"row_index":54,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Metal concentrations: *) Range: Ba (0,20 – 30,0) mg/l Mo (0,50 – 5,0) mg/l Flame atomic absorption spectrometry method (FAAS) ILB3b-16 wydanie 4 z 31.08.2020 r.","search_zh":"水、生活饮用水 ILB3b-16 wydanie 4 z 31.08.2020 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252617","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Chemiczne zapotrzebowanie tlenu - CHZT Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD Range: (5,0 – 10000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - CHZT Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Chemiczne zapotrzebowanie tlenu - CHZT Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu - CHZT Zakres: (5,0 – 10000) mg/l Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Chemical oxygen demand - COD Range: (5,0 – 10000) mg/l Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 PN-ISO 15705:2005","test_object_zh":"水"},{"_id":"6a5a55f99af9f73f38252618","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna","reference":"ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","norm_bases":["ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 Woda, woda do spozycia przez ludzi Stezenie fluorkow Zakres: (0,1 – 25) mg/l Metoda spektrofotometryczna ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Fluoride concentration Range: (0,1 – 25) mg/l Spectrophotometric method ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","search_zh":"水、生活饮用水 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55f99af9f73f38252619","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption pH Range: 3,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、生活饮用水 pH 范围：3,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水","methodology_zh":"pH 范围：3,0 – 10,0 电位法"},{"_id":"6a5a55f99af9f73f3825261a","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Zawartość pierwiastków: Zakres: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Content of elements: Range: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Inductively coupled plasma atomic emission spectrometry (ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: Zakres: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawartość pierwiastków: Zakres: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi, scieki Zawartosc pierwiastkow: Zakres: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Content of elements: Range: Ag (0,001 – 100) mg/l Al (0,010 – 250) mg/l As (0,003 – 100) mg/l B (0,015 – 500) mg/l Ba (0,010 – 100) mg/l Ca (0,010 – 250000) mg/l Cd (0,001 – 500) mg/l Co (0,010 – 200) mg/l Cr (0,005 – 500) mg/l Cu (0,005 – 1000) mg/l Fe (0,005 – 10000) mg/l K (1,000 – 100000) mg/l Mg (0,010 – 200000) mg/l Mo (0,010 – 100) mg/l Mn (0,001 – 500) mg/l Na (0,50 – 100000) mg/l Ni (0,004 – 500) mg/l Pb (0,002 – 500) mg/l Sb (0,050 – 100) mg/l Se (0,050 – 100) mg/l Tl (0,010 – 200) mg/l V (0,010 – 200) mg/l Zn (0,005 – 1000) mg/l Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN ISO 11885:2009","search_zh":"水、生活饮用水、污水 PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f99af9f73f3825261b","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Zawartość pierwiastków: Zakres: Hg (0,0002 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","methodology_en":"Content of elements: Range: Hg (0,0002 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków: Zakres: Hg (0,0002 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"ILB3b-5 wydanie 2 z 31.08.2020 r.","norm_bases":["ILB3b-5 wydanie 2 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawartość pierwiastków: Zakres: Hg (0,0002 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji ILB3b-5 wydanie 2 z 31.08.2020 r. Woda, woda do spozycia przez ludzi, scieki Zawartosc pierwiastkow: Zakres: Hg (0,0002 – 0,010) mg/l Metoda absorpcyjnej spektrometrii atomowej z technika amalgamacji ILB3b-5 wydanie 2 z 31.08.2020 r.","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Content of elements: Range: Hg (0,0002 – 0,010) mg/l Atomic absorption spectrometry with amalgamation technique method ILB3b-5 wydanie 2 z 31.08.2020 r.","search_zh":"水、生活饮用水、污水 ILB3b-5 wydanie 2 z 31.08.2020 r.","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f99af9f73f3825261c","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019","norm_bases":["PN-EN ISO 5815-1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019","search_zh":"水、生活饮用水、污水 PN-EN ISO 5815-1:2019","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a5a55f99af9f73f3825261d","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","test_object_en":"Water, water intended for human consumption, wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, woda do spozycia przez ludzi, scieki Zawiesiny ogolne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption, wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、生活饮用水、污水 总悬浮物 范围：(2,0 – 5000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总悬浮物 范围：(2,0 – 5000) mg/l 重量法"},{"_id":"6a5a55f99af9f73f3825261e","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","test_object_en":"Waste O): code 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","methodology":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,1 – 99,9) % Metoda wagowa","methodology_en":"Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,1 – 99,9) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,1 – 99,9) % Metoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12879:2004 Odpady O): kod 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Straty przy prazeniu suchej masy (LOI) / Pozostalosc po prazeniu Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12879:2004","categories":["environment"],"row_index":62,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Loss on ignition of dry matter (LOI) / Residue on ignition Range: (0,1 – 99,9) % Gravimetric method PN-EN 12879:2004"},{"_id":"6a5a55f99af9f73f3825261f","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","test_object_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","methodology":"Sucha masa / zawartość wody Zakres: (0,10 – 99,9) % Metoda wagowa","methodology_en":"Dry matter / water content Range: (0,10 – 99,9) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha masa / zawartość wody Zakres: (0,10 – 99,9) % Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Sucha masa / zawartość wody Zakres: (0,10 – 99,9) % Metoda wagowa PN-EN 12880:2004 Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Sucha masa / zawartosc wody Zakres: (0,10 – 99,9) % Metoda wagowa PN-EN 12880:2004","categories":["environment","water"],"row_index":63,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Dry matter / water content Range: (0,10 – 99,9) % Gravimetric method PN-EN 12880:2004"},{"_id":"6a5a55f99af9f73f38252620","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","test_object_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99","methodology":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN 12457-4:2006 PN-EN ISO 10523:2012","norm_bases":["PN-EN 12457-4:2006 PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012 Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 pH Zakres: 3,0 – 10,0 Metoda potencjometryczna PN-EN 12457-4:2006 PN-EN ISO 10523:2012","categories":["environment"],"row_index":64,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02, 19 08 05, 20 02 03, 20 03 03, 20 03 99 pH Range: 3,0 – 10,0 Potentiometric method PN-EN 12457-4:2006 PN-EN ISO 10523:2012","methodology_zh":"pH 范围：3,0 – 10,0 电位法","search_zh":"pH 范围：3,0 – 10,0 电位法 PN-EN 12457-4:2006 PN-EN ISO 10523:2012"},{"_id":"6a5a55f99af9f73f38252621","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 19 08 01, 19 08 02","test_object_en":"Waste O): code 19 08 01, 19 08 02","methodology":"Zawartość metali: *) Zakres: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal content: *) Range: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali: *) Zakres: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 12457-4:2006 PN-ISO 8288:2002","norm_bases":["PN-EN 12457-4:2006 PN-ISO 8288:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 01, 19 08 02 Zawartość metali: *) Zakres: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 PN-ISO 8288:2002 Odpady O): kod 19 08 01, 19 08 02 Zawartosc metali: *) Zakres: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 PN-ISO 8288:2002","categories":["materials","environment"],"row_index":65,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 19 08 01, 19 08 02 Metal content: *) Range: Cu (5,0 – 10 000) mg/kg Cd (5,0 – 500) mg/kg Ni (5,0 – 10000) mg/kg Pb (10 – 5000) mg/kg Zn (5,0 –10000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 PN-ISO 8288:2002","search_zh":"废物 O)：代码 19 08 01、19 08 02 PN-EN 12457-4:2006 PN-ISO 8288:2002","test_object_zh":"废物 O)：代码 19 08 01、19 08 02"},{"_id":"6a5a55f99af9f73f38252622","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 19 08 01, 19 08 02","test_object_en":"Waste O): code 19 08 01, 19 08 02","methodology":"Zawartość chromu: *) Zakres: Cr (5,0 – 5000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Chromium content: *) Range: Cr (5,0 – 5000) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chromu: *) Zakres: Cr (5,0 – 5000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3","norm_bases":["PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 01, 19 08 02 Zawartość chromu: *) Zakres: Cr (5,0 – 5000) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3 Odpady O): kod 19 08 01, 19 08 02 Zawartosc chromu: *) Zakres: Cr (5,0 – 5000) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3","categories":["environment"],"row_index":66,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 19 08 01, 19 08 02 Chromium content: *) Range: Cr (5,0 – 5000) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3","search_zh":"废物 O)：代码 19 08 01、19 08 02 PN-EN 12457-4:2006 PN-EN 1233:2000 pkt 3","test_object_zh":"废物 O)：代码 19 08 01、19 08 02"},{"_id":"6a5a55f99af9f73f38252623","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 19 08 01, 19 08 02","test_object_en":"Waste O): code 19 08 01, 19 08 02","methodology":"Zawartość metali: *) Zakres: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal content: *) Range: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Flame atomic absorption spectrometry (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość metali: *) Zakres: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.","norm_bases":["PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 01, 19 08 02 Zawartość metali: *) Zakres: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r. Odpady O): kod 19 08 01, 19 08 02 Zawartosc metali: *) Zakres: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.","categories":["materials","environment"],"row_index":67,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 19 08 01, 19 08 02 Metal content: *) Range: Ba (10 – 300) mg/kg Mo (5,0 – 50) mg/kg Flame atomic absorption spectrometry (FAAS) PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.","search_zh":"废物 O)：代码 19 08 01、19 08 02 PN-EN 12457-4:2006 ILB3b-16 wydanie 4 z 31.08.2020 r.","test_object_zh":"废物 O)：代码 19 08 01、19 08 02"},{"_id":"6a5a55f99af9f73f38252624","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 19 08 01, 19 08 02","test_object_en":"Waste O): code 19 08 01, 19 08 02","methodology":"Zawartość rtęci Zakres: (0,05 – 10) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","methodology_en":"Mercury content Range: (0,05 – 10) mg/kg Cold mercury vapour atomic absorption spectrometry (CVAAS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,05 – 10) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS)","reference":"PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.","norm_bases":["PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 19 08 01, 19 08 02 Zawartość rtęci Zakres: (0,05 – 10) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rtęci (CVAAS) PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r. Odpady O): kod 19 08 01, 19 08 02 Zawartosc rteci Zakres: (0,05 – 10) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par rteci (CVAAS) PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.","categories":["environment"],"row_index":68,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 19 08 01, 19 08 02 Mercury content Range: (0,05 – 10) mg/kg Cold mercury vapour atomic absorption spectrometry (CVAAS) method PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.","search_zh":"废物 O)：代码 19 08 01、19 08 02 PN-EN 12457-4:2006 ILB3b-01 wydanie 6 z 31.08.2020 r.","test_object_zh":"废物 O)：代码 19 08 01、19 08 02"},{"_id":"6a5a55f99af9f73f38252625","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02","test_object_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02","methodology":"Zawartość chlorków Zakres: (50 – 20000) mg/kg Metoda miareczkowa","methodology_en":"Chloride content Range: (50 – 20000) mg/kg Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość chlorków Zakres: (50 – 20000) mg/kg Metoda miareczkowa","reference":"PN-EN 12457-4:2006 PN-ISO 9297:1994","norm_bases":["PN-EN 12457-4:2006 PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02 Zawartość chlorków Zakres: (50 – 20000) mg/kg Metoda miareczkowa PN-EN 12457-4:2006 PN-ISO 9297:1994 Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02 Zawartosc chlorkow Zakres: (50 – 20000) mg/kg Metoda miareczkowa PN-EN 12457-4:2006 PN-ISO 9297:1994","categories":["environment"],"row_index":69,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 Chloride content Range: (50 – 20000) mg/kg Titrimetric method PN-EN 12457-4:2006 PN-ISO 9297:1994"},{"_id":"6a5a55f99af9f73f38252626","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02","test_object_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02","methodology":"Zawartość fluorków Zakres: (1,0 – 15,0) mg/kg Metoda spektrofotometryczna","methodology_en":"Fluoride content Range: (1,0 – 15,0) mg/kg Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość fluorków Zakres: (1,0 – 15,0) mg/kg Metoda spektrofotometryczna","reference":"PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","norm_bases":["PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02 Zawartość fluorków Zakres: (1,0 – 15,0) mg/kg Metoda spektrofotometryczna PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323 Odpady O): kod 02 03 05, 17 03 80, 19 08 01, 19 08 02 Zawartosc fluorkow Zakres: (1,0 – 15,0) mg/kg Metoda spektrofotometryczna PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323","categories":["environment"],"row_index":70,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 02 03 05, 17 03 80, 19 08 01, 19 08 02 Fluoride content Range: (1,0 – 15,0) mg/kg Spectrophotometric method PN-EN 12457-4:2006 ILB3b-15 wydanie 5 z 26.07.2021 r. na podstawie testu Hach Lange LCK 323"},{"_id":"6a5a55f99af9f73f38252627","lab_id":"69ad52a3de79e566650fb704","country":"PL","accr_number":"AB 1365","accr_body":"PCA","test_object":"Odpady O): kod 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99","test_object_en":"Waste O): code 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006","norm_bases":["ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady O): kod 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Pobieranie próbek do badań chemicznych i fizycznych ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006 Odpady O): kod 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Pobieranie probek do badan chemicznych i fizycznych ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006","categories":["environment"],"row_index":71,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste O): code 02 03 05, 10 01 01, 17 03 80, 19 08 01, 19 0 802, 19 08 05, 20 02 03, 20 03 03, 20 03 99 Sampling for chemical and physical testing ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 ILB3b-13 wydanie 8 z 27.09.2020 r. PN-EN 14899:2006"}],"has_pdf":true}