🇵🇱 PHILIP MORRIS POLSKA S.A. PL

PCA AB 1356 • Kraków, Poland • 9 methods

Electronics & EMCWater & wastewater

PHILIP MORRIS POLSKA S.A. is a laboratory accredited by PCA under number AB 1356 (Kraków, Poland). Its accreditation scope covers 9 test methods in the following areas: Electronics & EMC, Water & wastewater. Test objects include: Wyroby tytoniowe E / Tobacco products, Tobacco products E: - tobacco insert for an electronic heating device. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Calculation method, Combustion method in a test chamber.

At a glance

  • Accreditation number: PCA AB 1356
  • Methods in scope: 9
  • Types of test objects: 2
  • Techniques used: 8
  • City: Kraków, Poland
Accreditation number
AB 1356
Accreditation body
PCA
Address
Al. Jana Pawła II 196, 31-982 Kraków
City
Kraków, Poland

What this laboratory tests (2)

Analytical techniques used (8)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (9)

No. Test object Methodology / Parameters Technique Reference document
LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)
1 Wyroby tytoniowe E / Tobacco products Zawartość wody w kondensacie dymu na papieros (Water in smoke per cigarette)
Range (0,100 – 4,000) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Metoda chromatografii gazowej z detekcją cieplno-przewodnościową (GC-TCD) ISO 10362-1
2 Wyroby tytoniowe E / Tobacco products Zawartość nikotyny w kondensacie dymu na papieros (Nicotine in smoke per cigarette)
Range (0,10 – 1,50) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) ISO 10315
3 Wyroby tytoniowe E / Tobacco products Zawartość tlenku węgla w fazie gazowej dymu papierosowego na papieros (Carbon Monoxide per cigarette)
Range (1,5 – 16,5) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Infrared spectrometry method (IR) ISO 8454
4 Wyroby tytoniowe E / Tobacco products Zawartość surowego kondensatu dymu na papieros (Total Particulate Matter per cigarette)
Range (1,0 – 20,0) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gravimetric method ISO 4387
5 Wyroby tytoniowe E / Tobacco products Zawartość substancji smolistych na papieros (TAR per cigarette)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Calculation method ISO 4387
6 Wyroby tytoniowe E / Tobacco products Zawartość mentolu w kondensacie dymu na papieros (Menthol in TPM per cigarette)
Range (0,10 – 2,50) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with flame ionization detection (GC-FID) ISO 13110
7 Wyroby tytoniowe E / Tobacco products Zdolność zapłonu papierosów (RCIP Full Length Burn)
Range (0 – 100) %
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Combustion method in a test chamber PN-EN ISO 12863 | ISO 12863 | ASTM E2187
LABORATORIUM KONTROLI JAKOŚCI – PRODUKTÓW BEZDYMNYCH (QC-SFP)
8 Tobacco products E: - tobacco insert for an electronic heating device Stężenie związków organicznych w areozolu:
Nikotyna (Nicotine) (7,50 – 75,0) µg/ml Mentol (Menthol) (5,00 – 200,0) µg/ml Fenol (Phenol) (0,0100 – 0,190) µg/ml Gliceryna (Glycerin) (35,0 – 350,0) µg/ml Zawartość związków organicznych (z obliczeń)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with mass spectrometry detection (GC-MS) QMS-0030847
9 Tobacco products E: - tobacco insert for an electronic heating device Zawartość tlenku węgla w aerozolu na wkład (Carbon Monoxide per stick)
Range (0,06 – 0,5) mg
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Spectrometry method in the infrared range (IR) QMS-0008987

Reference standards (10)

ASTM E2187
ISO 10315
ISO 10362-1
ISO 12863
ISO 13110
ISO 4387
ISO 8454
PN-EN ISO 12863
QMS-0008987
QMS-0030847