{"lab":{"_id":"69ad52a3de79e566650fb6f4","accr_number":"AB 1356","country":"PL","accr_body":"PCA","address":"Al. Jana Pawła II 196, 31-982 Kraków","categories":["electronics","water"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":9,"name":"PHILIP MORRIS POLSKA S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1356.pdf"],"scope_summary":"","search_text":"philip morris polska s.a. al. jana pawła ii 196, 31-982 kraków water other electronics pharma automotive","status":"active","updated_at":"2026-03-08T14:50:31.889Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T10:19:54.887Z","email_confidence":"low","email_mx":true,"email_source":"https://www.pmi.com/markets/poland/pl/about-us/overview","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","parse_date":"2026-08-17T10:19:54.887Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/24","pl":"Badania chemiczne wyrobów tytoniowych","en":"Chemical tests of tobacco products"},{"codes":"N/24","pl":"Badania właściwości fizycznych wyrobów tytoniowych","en":"Tests of physical properties of tobacco products"}],"issue":{"no":"21","date":"24.07.2026"},"map_coord":[50.155852,19.951493],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","address":"Al. Jana Pawła II 196, 31-982 Kraków","city":"Kraków","postal":"31-982"},{"name":"LABORATORIUM KONTROLI JAKOŚCI – PRODUKTÓW BEZDYMNYCH (QC-SFP)","address":"Al. Jana Pawła II 196, 31-982 Kraków","city":"Kraków","postal":"31-982"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/5819f3e28d2b9be48656a3d69e9897e4/AB%201356.pdf","has_en":true,"category_counts":{"other":6,"electronics":2,"water":1},"category_scores":{"other":4,"electronics":0.44,"water":0.11},"has_zh":true},"methods":[{"_id":"6a82e04a884ede9a1b2c3757","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość wody w kondensacie dymu na papieros (Water in smoke per cigarette)","parameters":[{"name":"Zakres","range":"(0,100 – 4,000) mg"}],"technique":"Metoda chromatografii gazowej z detekcją cieplno-przewodnościową (GC-TCD)","techniques":["Metoda chromatografii gazowej z detekcją cieplno-przewodnościową (GC-TCD)"],"computed":[],"activity":"Zawartość wody w kondensacie dymu na papieros (Water in smoke per cigarette)\nZakres (0,100 – 4,000) mg\nMetoda chromatografii gazowej z detekcją cieplno-przewodnościową (GC-TCD)","reference":"ISO 10362-1","norm_bases":["ISO 10362-1"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość wody w kondensacie dymu na papieros (Water in smoke per cigarette)\nZakres (0,100 – 4,000) mg\nMetoda chromatografii gazowej z detekcją cieplno-przewodnościową (GC-TCD) ISO 10362-1 Wyroby tytoniowe E / Tobacco products Zawartosc wody w kondensacie dymu na papieros (Water in smoke per cigarette)\nZakres (0,100 – 4,000) mg\nMetoda chromatografii gazowej z detekcja cieplno-przewodnosciowa (GC-TCD) ISO 10362-1","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,100 – 4,000) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range ISO 10362-1","parameters_zh":[{"name":"范围","range":"(0,100 – 4,000) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 ISO 10362-1"},{"_id":"6a82e04a884ede9a1b2c3758","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość nikotyny w kondensacie dymu na papieros (Nicotine in smoke per cigarette)","parameters":[{"name":"Zakres","range":"(0,10 – 1,50) mg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość nikotyny w kondensacie dymu na papieros (Nicotine in smoke per cigarette)\nZakres (0,10 – 1,50) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ISO 10315","norm_bases":["ISO 10315"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość nikotyny w kondensacie dymu na papieros (Nicotine in smoke per cigarette)\nZakres (0,10 – 1,50) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ISO 10315 Wyroby tytoniowe E / Tobacco products Zawartosc nikotyny w kondensacie dymu na papieros (Nicotine in smoke per cigarette)\nZakres (0,10 – 1,50) mg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ISO 10315","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,10 – 1,50) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range ISO 10315","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(0,10 – 1,50) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 ISO 10315","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a82e04a884ede9a1b2c3759","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość tlenku węgla w fazie gazowej dymu papierosowego na papieros (Carbon Monoxide per cigarette)","parameters":[{"name":"Zakres","range":"(1,5 – 16,5) mg"}],"technique":"Metoda spektometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Zawartość tlenku węgla w fazie gazowej dymu papierosowego na papieros (Carbon Monoxide per cigarette)\nZakres (1,5 – 16,5) mg\nMetoda spektometrii w zakresie podczerwieni (IR)","reference":"ISO 8454","norm_bases":["ISO 8454"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość tlenku węgla w fazie gazowej dymu papierosowego na papieros (Carbon Monoxide per cigarette)\nZakres (1,5 – 16,5) mg\nMetoda spektometrii w zakresie podczerwieni (IR) ISO 8454 Wyroby tytoniowe E / Tobacco products Zawartosc tlenku wegla w fazie gazowej dymu papierosowego na papieros (Carbon Monoxide per cigarette)\nZakres (1,5 – 16,5) mg\nMetoda spektometrii w zakresie podczerwieni (IR) ISO 8454","categories":["other"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,5 – 16,5) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Infrared spectrometry method (IR) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range ISO 8454","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(1,5 – 16,5) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 ISO 8454"},{"_id":"6a82e04a884ede9a1b2c375a","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość surowego kondensatu dymu na papieros (Total Particulate Matter per cigarette)","parameters":[{"name":"Zakres","range":"(1,0 – 20,0) mg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość surowego kondensatu dymu na papieros (Total Particulate Matter per cigarette)\nZakres (1,0 – 20,0) mg\nMetoda wagowa","reference":"ISO 4387","norm_bases":["ISO 4387"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość surowego kondensatu dymu na papieros (Total Particulate Matter per cigarette)\nZakres (1,0 – 20,0) mg\nMetoda wagowa ISO 4387 Wyroby tytoniowe E / Tobacco products Zawartosc surowego kondensatu dymu na papieros (Total Particulate Matter per cigarette)\nZakres (1,0 – 20,0) mg\nMetoda wagowa ISO 4387","categories":["other"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(1,0 – 20,0) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Gravimetric method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range ISO 4387","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(1,0 – 20,0) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"重量法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 ISO 4387","technique_zh":"重量法"},{"_id":"6a82e04a884ede9a1b2c375b","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość substancji smolistych na papieros (TAR per cigarette)","parameters":[],"technique":"Metoda z obliczeń","techniques":["Metoda z obliczeń"],"computed":[],"activity":"Zawartość substancji smolistych na papieros (TAR per cigarette)\nMetoda z obliczeń","reference":"ISO 4387","norm_bases":["ISO 4387"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość substancji smolistych na papieros (TAR per cigarette)\nMetoda z obliczeń ISO 4387 Wyroby tytoniowe E / Tobacco products Zawartosc substancji smolistych na papieros (TAR per cigarette)\nMetoda z obliczen ISO 4387","categories":["other"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Calculation method E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. ISO 4387","technique_en":"Calculation method","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"计算法 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 ISO 4387","technique_zh":"计算法"},{"_id":"6a82e04a884ede9a1b2c375c","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zawartość mentolu w kondensacie dymu na papieros (Menthol in TPM per cigarette)","parameters":[{"name":"Zakres","range":"(0,10 – 2,50) mg"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość mentolu w kondensacie dymu na papieros (Menthol in TPM per cigarette)\nZakres (0,10 – 2,50) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"ISO 13110","norm_bases":["ISO 13110"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zawartość mentolu w kondensacie dymu na papieros (Menthol in TPM per cigarette)\nZakres (0,10 – 2,50) mg\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) ISO 13110 Wyroby tytoniowe E / Tobacco products Zawartosc mentolu w kondensacie dymu na papieros (Menthol in TPM per cigarette)\nZakres (0,10 – 2,50) mg\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) ISO 13110","categories":["other"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,10 – 2,50) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Gas chromatography with flame ionization detection (GC-FID) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range ISO 13110","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","parameters_zh":[{"name":"范围","range":"(0,10 – 2,50) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 ISO 13110","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）"},{"_id":"6a82e04a884ede9a1b2c375d","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E / Tobacco products","methodology":"Zdolność zapłonu papierosów (RCIP Full Length Burn)","parameters":[{"name":"Zakres","range":"(0 – 100) %"}],"technique":"Metoda spalania w komorze testowej","techniques":["Metoda spalania w komorze testowej"],"computed":[],"activity":"Zdolność zapłonu papierosów (RCIP Full Length Burn)\nZakres (0 – 100) %\nMetoda spalania w komorze testowej","reference":"PN-EN ISO 12863 | ISO 12863 | ASTM E2187","norm_bases":["PN-EN ISO 12863","ISO 12863","ASTM E2187"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – KONWENCJONALNYCH WYROBÓW TYTONIOWYCH (QC-CC)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E / Tobacco products Zdolność zapłonu papierosów (RCIP Full Length Burn)\nZakres (0 – 100) %\nMetoda spalania w komorze testowej PN-EN ISO 12863 | ISO 12863 | ASTM E2187 Wyroby tytoniowe E / Tobacco products Zdolnosc zaplonu papierosow (RCIP Full Length Burn)\nZakres (0 – 100) %\nMetoda spalania w komorze testowej PN-EN ISO 12863 | ISO 12863 | ASTM E2187","categories":["other"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0 – 100) %"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Combustion method in a test chamber E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range PN-EN ISO 12863 | ISO 12863 | ASTM E2187","technique_en":"Combustion method in a test chamber","parameters_zh":[{"name":"范围","range":"(0 – 100) %"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 PN-EN ISO 12863 | ISO 12863 | ASTM E2187"},{"_id":"6a82e04a884ede9a1b2c375e","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E: - wkład tytoniowy do elektronicznego urządzenia podgrzewającego","methodology":"Stężenie związków organicznych w areozolu:","parameters":[{"name":"Nikotyna (Nicotine)","range":"(7,50 – 75,0) µg/ml"},{"name":"Mentol (Menthol)","range":"(5,00 – 200,0) µg/ml"},{"name":"Fenol (Phenol)","range":"(0,0100 – 0,190) µg/ml"},{"name":"Gliceryna (Glycerin)","range":"(35,0 – 350,0) µg/ml"},{"name":"Zawartość związków organicznych (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","techniques":["Metoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)"],"computed":[],"activity":"Stężenie związków organicznych w areozolu:\nZakres:\nNikotyna (Nicotine) (7,50 – 75,0) µg/ml\nMentol (Menthol) (5,00 – 200,0) µg/ml\nFenol (Phenol) (0,0100 – 0,190) µg/ml\nGliceryna (Glycerin) (35,0 – 350,0) µg/ml\nZawartość związków organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS)","reference":"QMS-0030847","norm_bases":["QMS-0030847"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – PRODUKTÓW BEZDYMNYCH (QC-SFP)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E: - wkład tytoniowy do elektronicznego urządzenia podgrzewającego Stężenie związków organicznych w areozolu:\nZakres:\nNikotyna (Nicotine) (7,50 – 75,0) µg/ml\nMentol (Menthol) (5,00 – 200,0) µg/ml\nFenol (Phenol) (0,0100 – 0,190) µg/ml\nGliceryna (Glycerin) (35,0 – 350,0) µg/ml\nZawartość związków organicznych (z obliczeń)\nMetoda chromatografii gazowej z detekcją spektrometrią mas (GC-MS) QMS-0030847 Wyroby tytoniowe E: - wklad tytoniowy do elektronicznego urzadzenia podgrzewajacego Stezenie zwiazkow organicznych w areozolu:\nZakres:\nNikotyna (Nicotine) (7,50 – 75,0) µg/ml\nMentol (Menthol) (5,00 – 200,0) µg/ml\nFenol (Phenol) (0,0100 – 0,190) µg/ml\nGliceryna (Glycerin) (35,0 – 350,0) µg/ml\nZawartosc zwiazkow organicznych (z obliczen)\nMetoda chromatografii gazowej z detekcja spektrometria mas (GC-MS) QMS-0030847","categories":["electronics"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Tobacco products E: - tobacco insert for an electronic heating device Gas chromatography with mass spectrometry detection (GC-MS) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. QMS-0030847","technique_en":"Gas chromatography with mass spectrometry detection (GC-MS)","test_object_en":"Tobacco products E: - tobacco insert for an electronic heating device","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"气相色谱-质谱法（GC-MS） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 QMS-0030847","technique_zh":"气相色谱-质谱法（GC-MS）"},{"_id":"6a82e04a884ede9a1b2c375f","lab_id":"69ad52a3de79e566650fb6f4","country":"PL","accr_number":"AB 1356","accr_body":"PCA","test_object":"Wyroby tytoniowe E: - wkład tytoniowy do elektronicznego urządzenia podgrzewającego","methodology":"Zawartość tlenku węgla w aerozolu na wkład (Carbon Monoxide per stick)","parameters":[{"name":"Zakres","range":"(0,06 – 0,5) mg"}],"technique":"Metoda spektrometrii w zakresie podczerwieni (IR)","techniques":["Metoda spektrometrii w zakresie podczerwieni (IR)"],"computed":[],"activity":"Zawartość tlenku węgla w aerozolu na wkład (Carbon Monoxide per stick)\nZakres (0,06 – 0,5) mg\nMetoda spektrometrii w zakresie podczerwieni (IR)","reference":"QMS-0008987","norm_bases":["QMS-0008987"],"lab_section":"LABORATORIUM KONTROLI JAKOŚCI – PRODUKTÓW BEZDYMNYCH (QC-SFP)","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Wyroby tytoniowe E: - wkład tytoniowy do elektronicznego urządzenia podgrzewającego Zawartość tlenku węgla w aerozolu na wkład (Carbon Monoxide per stick)\nZakres (0,06 – 0,5) mg\nMetoda spektrometrii w zakresie podczerwieni (IR) QMS-0008987 Wyroby tytoniowe E: - wklad tytoniowy do elektronicznego urzadzenia podgrzewajacego Zawartosc tlenku wegla w aerozolu na wklad (Carbon Monoxide per stick)\nZakres (0,06 – 0,5) mg\nMetoda spektrometrii w zakresie podczerwieni (IR) QMS-0008987","categories":["electronics"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,06 – 0,5) mg"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Tobacco products E: - tobacco insert for an electronic heating device Spectrometry method in the infrared range (IR) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Range QMS-0008987","technique_en":"Spectrometry method in the infrared range (IR)","test_object_en":"Tobacco products E: - tobacco insert for an electronic heating device","parameters_zh":[{"name":"范围","range":"(0,06 – 0,5) mg"}],"regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"红外光谱法（IR） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 范围 QMS-0008987","technique_zh":"红外光谱法（IR）"}],"has_pdf":true}