🇵🇱 ECOCENTRUM ELŻBIETA WOLNY PL

PCA AB 1343 • Wrocław, Poland • 19 methods

Water & wastewaterEnvironmentMicrobiology

ECOCENTRUM ELŻBIETA WOLNY is a laboratory accredited by PCA under number AB 1343 (Wrocław, Poland). Its accreditation scope covers 19 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Sewage sludge, Soil, Wastewater, Water intended for human consumption Water.

At a glance

  • Accreditation number: PCA AB 1343
  • Methods in scope: 19
  • Types of test objects: 12
  • City: Wrocław, Poland
Accreditation number
AB 1343
Accreditation body
PCA
Address
ul. Muchoborska 18, 54-424 Wrocław
City
Wrocław, Poland

What this laboratory tests (12)

Accreditation scope — test methods (19)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C PN-ISO 5667-5:2017-10 PB-01-05 z dnia 31.03.2025 r.
2 Water Sampling for chemical and physical testing Temperature of the collected water sample Range: (0,0 – 65,0) C PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2 | PB-01-05
3 Water intended for human consumption Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1
4 Water intended for human consumption Water Total chlorine concentration Range: (0,02 – 8,0) mg/l Free chlorine concentration Range: (0,02 – 8,0) mg/l Colorimetric method Combined chlorine (calculated) PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070
5 Wastewater Sampling for chemical and physical testing Manual method and automatic method Temperature of wastewater / of the wastewater sample taken Range: (0,0 – 65,0) C PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.
6 Wastewater Sampling for microbiological testing PN-EN ISO 19458:2007
7 Water intended for human consumption Water Wastewater pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012
8 Water intended for human consumption Water Wastewater Electrical conductivity Range: (100 – 13000) µS/cm Conductometric method PN-EN 27888:1999
9 Soil Sampling for chemical and physical testing PN-ISO 10381-4:2007
10 Soil Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.
11 Soil pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10390:2022-09
12 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4
13 Sewage sludge Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.
14 Sewage sludge pH – in H O 2 Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10390:2022-09
15 Waste O) code: 02 03 80 Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.
16 Waste O) code: 02 03 01, 02 03 80 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04
17 Waste O) code: 02 03 99, 02 03 81, 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4 | IB-05-04
18 Waste O) code: 19 08 05, 19 08 01, 19 08 02, 19 06 06, 19 06 05, 02 03 05 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4
19 Waste O) code: 19 08 05, 19 06 06, 19 06 05, 02 03 05 Sampling for microbiological testing PB-04-03 z dnia 02.01.2020 r.

Reference standards (14)

IB-05-04
PB-01-05
PB-04-03 z dnia 02.01.2020 r.
PB-06-03 z dnia 02.01.2020 r. na podstawie metod HACH nr 8021, 8167, 10069, 10070
PN-EN 27888:1999
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 19458:2007 z wyłączeniem punktu 4.4.4.1
PN-EN ISO 5667-13:2011 z wyłączeniem punktu 6.3.4
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktu 7.2
PN-ISO 10381-4:2007
PN-ISO 5667-10:2021-11 PB-01-05 z dnia 31.03.2025 r.